Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-03-2026 | Date postpone | Date | 17-03-2026 |
| 2 | 18-02-2026 | Postpone | Date | 10-03-2026 |
| 3 | 10-02-2026 | Postponed | Date | 27-02-2026 |
| Sl. No. | Item Description |
| 1 | PART I : BLDG WORK Material and Labour for taking out/pumping out contaminated water fromwater pool of size 25mx10mx3 m and diverting into open drain/areaas directed by Engineer-in-Charge complete all as specified and directed by Engr-in-charge. Notes : (i) Dewatering shall be done by suction pump/any mechanical means and disposedby truck mounted trailors to dispose off contaminated water and cost of the same shall deemed to be included in quoted rates.(ii) HIGH PRESSURE CLEANING AND SCRUBBING : Cleaning of walls, ceiling and floor by high pressure water jet mixed with detergent / cleaning agent appropriate for tank cleaninghaving rotary as well as flat jets for effective cleaning of the nooks, walls and corners and then scrubbing By stain (if required).(iii) VACUUM CLEANING: Wet and dry vacuum cleaning for moping of all dirt particles and residual sludge present in the sumps by industrial vacuum cleaner. (iv) Necessary T & P shall be arranged by the contractor by his own arrangement. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge |
| 3 | Material and Labour for applying chemical compound with dispersing agents Removing (and not damaging the beneath brick or RCC surface) old existing unserviceable concrete, cement plaster, loose / unsound weaken cement of any description and in any position from existing external / internal surfaces of walls, or any surface average depth 5-25mm (Approx height/depth 4.5 m from natural ground level) with concrete removing agent(except for zinc and galvanised metal)and clean the treated surface immediately after removal treatment, and removal up to the approval municipal dumping grounds specified by the local bodies outside the premises including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale/ rust etc from the visible unplastered surface |
| 4 | Material and Labour for cutting \"U\" shaped grove carefully by diamond cutter, breaker etc without damagingthe structure in RCCmembers i.e. internal surface, of size approx 37mm (depth) x 25mm (width) along the constructions joints and other surfaces as directed and filling the \"U\" grove withPatch N plug of or equivalents in make AQUACREAT and PIDILITE over and including application ofcrystalline concrete slurry@ 0.04 kg/RM in the grove by brush application and allow to dry for 10 minutes as per manufacturers instructions complete all as specified and directed.Notes :- (a) Cost of providing scaffolding shall deemed to be included in quoted rates.(b) Structural treatment to be executed through authorised applicator of manufacturer as approved by GE. |
| 5 | Material and Labour for preparation of surface and applying 12.5mm thick fully consolidated rapid setting cementitious material with setting time 10 mins max @ 25kg/1.05 sqmby low pressure spray equipment or with trowel for patching and resurfacing of deteriorated concrete to produce superior bond low shrinkage, chemical durability and high strength mixed with water at site as per manufacture instructions/ specifications, initial setting time 3.25 hrs and final setting time 5.00 hrs with compressive strength 53 MPA in 28 days, as per manufacture instructions complete all as specified and directed by Engr-in-charge. Notes :- (a) Cost of providing scaffolding shall deemed to be included in quoted rates.(b) Structural treatment to be executed through authorised applicator of manufacturer as approved by GE. |
| 6 | Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or micro concrete to bonding old and new cementitious substrates as per manufacturer\"s specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C. Make :- TM bond EP of Thermax or Equivalent as approved by GE |
| 7 | Material and Labour for Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry. |
| 8 | Material and Labour for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours.The application shall be by brush.Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer |
| 9 | Material and Labour for high strength epoxy resin based Injection Grouting, Automatic NRV packers in all surfaces from all access side Distance of injections will be 500 mm c/c in matrix pattern untilis submerged in dampness of chemical. Injection grouting shall be using two component groutingpolymer having low viscosity, high molecular weight, thermosetting to reach very deep pores, voids, cracks and honeycomb in the concrete, specific gravity of which shall be 0.95, pH of 2-4,viscosity of 20-25 sec by B/4 ford cup and having curing time of 30-90 minutesarea by suitable gun/pump at required pressure (100 bar to 150 Bar), including cutting of nipples after curing etc and sealing the nozzles with epoxy putty and preparing the surface to match with the existing surfaces complete all as specified and directed.Make :- Carlisle Syntec/Thermax Ltd,/Kryton Build Mat Pvt Ltd/SNI Infratech Pvt. Ltd or equivalent as approved by GE |
| 10 | Material and Labour forwelded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material complete all as specified and directed |
| 11 | Material and Labour for providing and fixing welded MS wire mesh with anticorrosive primer applied on inner walls of pool weighing not less than 1kg/sqm applying and mixing mechanically PP fibre of 12 mm length with Anti-crack strength with 25-30 mm thickone component chloride free thixotropic fibre reinforced polymer modified repair mortar by shotcreting/guniting only complies with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 at the RCC surface mixed with in the ratio of0.33:1:4with cement and sand mortar and mixed with styrene butadiene polymerized cement mortar modifier or AR for bonding with cementitious mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) @ 2% by weight of cement and as per manufacturer\"s instructions.)and also applying AR Bondingagent on surface before plastering, makeof the Thermax or CIPY Chemicals Ltd/redwop chemicals /IWL Chemicals equivalent of webac chemicals/chemco system .complete all as specified and directed by Engr-in -charge. Notes : (a) Item shall be undertaken by the authorized rep of manufacturer through shotcreting/guniting only. (b) Wire mesh Shall be paid separately under relevant item |
| 12 | Material and Labour for providing fixing welded MS wire mesh weighing not less than 1 kg/sqmand mixing and applying mechanically PP fibre of 24 mm length with Anti-crack strength withRheoplasticnon shrink, corrosion resistant, High strength compound BS66 with integral liquid water proofing admixture1000L of make Thermax Ltd/ CIPY Chemicals Ltd/redwop chemicals /IWL Chemicals or equivalent of webac chemical/chemco system confirms to IS 2645-2003 having specific gravity 1.1 to 1.2 gm/cc chloride content : Nil as per IS 2645-2003 & resistant, High strength compound on internal floor, shallow bottomof pooland inner walls of pool if requiredetc, one component cementitious microconcrete thixotropic non shrinkagemucis having compressive strength as Bs 4551-80thickness of 50mm with 3:1:4 cement mortar and strength (ASTM C 109)-80 Mpa @ 28 days, Tensile strength 2.0N/mm2 @ 28 days (ASTM C 348)- 4 Mpa @ 28 days, Flexural strength 10N/mm2 (ASTM C 348)-11 Mpa @ 28 days, Young\"s modulus -27 KN/sqmm (ASTM D469), Expansion characteristics (ASTM C 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion -Approx. 0.004 N/sqmm., before pouring micro concrete through shotcreting/guniting only. It is recommended to apply granolithic E-Resin based solvent free concrete bonding agent or AR in accurate proportion with complete homogeneityMpa at 7 days, Tensile strength (BS 6319 pt.7)- 15 Mpa at 7 days, Bond strength (ASTM C 881)- 11 N/sqmm at 7 days, having an over lay time of 03 hrs at 30 C. complete including all tools and tackles as directed by Engr-in-Charge. Note: - Rate quoted shall include for necessary scaffolding required in the item. Make—thermax/ IWL India LTD/STP Ltd webac chemicals/chemco system.Note:- (a) Item shall be undertaken by the authorized rep of manufacturer through shotcreting/ guniting only.(b) Wire mesh shall be paid separately under relevant item. |
| 13 | Material and Labour for curing of the surface using wax based concrete curing compound curing efficiency; Make of -MaxCure CC of Thermax/IWL/chemco system/webac chemicals/ CIPY Chemicals Ltd/redwop chemicals /Redwop chemicalsetc compound complies with the internationally recognized ASTM C309-90 standards including all tools and tackles. Complete all as specified and directed by Engr-in-charge.Note :- Item shall be undertaken by the authorized rep of manufacturer.. |
| 14 | Material and Labour for applying a waterproofing agent with holding the quality of negative hydrostatic pressureon new plastered surface also meeting the elasticity modules as follows 28 days 14000-16000 N/mm2 adhesion to substrate 1 day 0.6N/mm2 28 days 1.3 N/mm2 compressive strength 1 day 12N/mm2 28 days 36N/mm2 flexural strength 1 day 3.6N/mm2 28 days 8.2 N/mm2, modified with special additives and ready to use. Make : Thermax/chemco systems/webac chemicals/IWL CHEM/CIPY Chemicals Ltd/redwop chemicals. .Mixed with water ,it cures forming a coating , with limited thickness which resists the penetration of water to achieve compressive strength of 36 N/mm2 in 3 days, adhesion bond strengthof 8.2 N/mm2. Coating to be applied after proper surface preparation to remove loose dust , dirt etc. Cleaning, mixing using slow speed electric drill and application of 2 coats. Complete as per specification. Note :- Item shall be undertaken by the authorized rep of manufacturer. |
| 15 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 16 | Demolition of RCC as in slab beam chajja (other than ground floor) beams staircase and similar all as specified and directed by Engr-in-Charge |
| 17 | Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MoD land, complete all as specified and as directed by Engr-in-charge. Notes :- 1. Taking down earthing strips incl insulators from roof for treatment and re-fixing of same with existing specification in the same position after laid APP membrane including replacement of broken insulators, PVC rawl plus & screws etc are deemed to be inclusive of rate quoted by the contractor.2.Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work.3. APP work shall be carried out on PENT RCC roof at 12 -15 mtr height (non accessible roof). |
| 18 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame)not exceeding 1.5 Square Metre each , removing from the site including cutting holes required fortaking out existing hold fast etc. complete all as specified and as directed. |
| 19 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqmnot exceeding 4.0 Square Metre each , removing from the site including cutting holes required fortaking out existing hold fast etc. complete all as specified and as directed. |
| 20 | Material and Labour Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engr-in-Charge.Note:- Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed. |
| 21 | Material and Labour for Mild SteelTMT bar of 5mm and over upto 10mm dia inor stirrups, spacers and bindersof designed diameter in various structural elements like column ,beams and foundations including drilling ,bending, welding and fixing the bars with epoxy putty etc. (Steel provided on the basis of 1% of volume of concrete). |
| 22 | Material and Labour for 40 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in SUB-FLOORS, SUB-BASES, FLOORS AND PAVINGS, ETC including WPC by weight of 3% of total cement contentcomplete all as specified and directed |
| 23 | Material and labour for cement concrete type D-2 1:4:8using 40mm graded crushed stone aggregateas in foundations, fillings & mass concrete etcall as specified and directed. |
| 24 | Material and Labour RCC (1:2:4) type B-0, using 12.5 mm graded mechanically crushed stone aggregates for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and Chajjascomplete all as specified and directed. |
| 25 | Supply and Fix of Designer Mosaic swimming pool tile of size 247 mm X 122 mm and thickness 8mm Standard on horizontal surface ( floor) and vertical surface in swimming pool of approved manufacturer and specified shade like Neo Pool Azure /Neo pool Deep Blue//Cloud Deep Sky/Pearl royal Blue Orient Blue / Dark Blue /new blue of Johnsonetc. laid in approved patter on 3-6 mm ( 5mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal endura gold star / letecrete / Rock force ) in conjunction with polymer modified liquid Bal endura admix Adlor equivalent product of letercrete / Rock ince mixed in required proportion as specified by manufacturer including filling / scaling of joints 2-3 mm thick between the tiles with epoxy grout of Bal Endura Epoxy grout / Letecrete / Rock force with matching colour pigment to make it water tight and finished neat complete, as approved and directed by Engineer-in-charge. |
| 26 | Supply and Fix vitrified finger grip tile any size and thickness 8mm of rounding of corner, Junction avoiding sharp edges Standard on in swimming pool approved manufacturer and specified shade like Orient Blue / Dark Blue /new blue etc. laid in approved pattern on 3-6 mm ( 5mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal endura gold star / letecrete / Rock force) in conjunction with polymer modified liquid Bal endura admix Adlor equivalent product of letercrete / Rock force mixed in required proportion as specified by manufacturer including filling / scaling of joints 2-3 mm thick between the tiles with epoxy grout of Bal endura epoxy grout / Letecrete / Rock force with matching colour pigment to make it water tight and finished neat complete all as specified and as directed by Engineer-in-Charge |
| 27 | Material and Labour for factory made Heavy Duty Non skid endura tileultra strong in digital pattern of size 300mm x 300mm thickness of tiles 08 to 10 mm, set, jointed and pointed in near cement slurry in floors, with grey cement and pigments and laid over & including 15 mm thick screed bedding in CM 1:6 complete all as specified and as directed by Engineer-in-Charge |
| 28 | Material and Labour Hand cutKota stone slab flooring 20-25mm thick over cement screed base laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & mirror polishingincluding 20mm thick screed bed in Cement Mortar 1:4 complete all as specified and directed by Engr-in-charge. |
| 29 | Material and Labour Hand cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement including rubbing & mirror polishingincluding 10mm thick rendering in Cement Mortar 1:4complete all as specified and directed by Engr-in-charge. |
| 30 | Material and Labour non skid colouredceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floorover 20 mm thickscreed bed in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed. |
| 31 | Material and Labour non skid colouredceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in skirting/dado over 10 mm thickcement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed. |
| 32 | Supply and Fix green marble 16-18 mm thick machine cut, jointing and pointing with white cement slurry including 20mm thick screed bed or bedding layer of mortar in CM 1:4includingdismantling of old stone slab / tiles complete all as specified and directed. |
| 33 | Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand cushion for maintain camber and slope all as per directed by Engr-In Charge.Note:- Sand Cushion will be paid separately under relevant item of this schedule. |
| 34 | Material and Labour for60 mm thicknessMachine pressed precast concrete inter locking paver block glazed coloured upto 6mm on top in any shape and size , strength not less than M-35 Grade all as directed by Engr-in-charge |
| 35 | Material and Labour Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engr-in-Charge. |
| 36 | Supply and Fix rolling shutter without ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple, gear operated type with chain wheel and hand chain and primer erected in positionincluding taking down of old Shutteras directed. |
| 37 | Supply and Fix in repair to stainless steel 304 grade framed work fancy/ornamental type in Gates/stair hosing work andother similar worksincluding all or any type of welding, holdfast, locking arrangement,followed by buffering and polishing for smooth finish including taking down of old SS Railing/pillars complete all as specified and as directed by Engr-in-Charge. |
| 38 | Supply and Fix for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles including connected items, with and including making good to the disturbed portion with its original specifications complete all as specified and directed. |
| 39 | Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutterarea n. exceeding 0.50 Square Metre each panecomplete all as specified and as directed. |
| 40 | Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutterarea . exceeding 0.50 Square Metre each panecomplete all as specified and as directed. |
| 41 | Supply and Fix for concealed star lock powder coated for aluminium window fixed as per manufacturers instructions complete all as specified & asdirected. |
| 42 | Supply and Fix aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 43 | Supply and Fix for rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors etc complete all as specified and as directed. |
| 44 | Supply and Fix of aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed. Make- Deco grill or equivalent |
| 45 | Supply & fixing of framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls including dismantling to existing frameworkas directed. |
| 46 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 47 | Material and Labour for pre-cast cement concreteblock masonry with solid blocks, exc. 10 cm in width in type B1 (1:2:4)(20mm graded stone aggregate )and setting in mortar (1:6)including demolition of old PCC Block complete all as specified and as directed |
| 48 | Material and Labour for ready mix plaster for rendering 15 mm thick in CM 1:4on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coatand 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement. |
| 49 | Material and Labour for ready mix plater for rendering 10 mm thick in CM 1:6 on fair facesof brick work or concrete surfaces finished even and smooth complete all as specified. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) |
| 50 | Material and Labour for ready mix plaster for rendering 5 mm thick on ceilings in cement mortar 1:3 and finishing the surface even and smooth without using extra cement complete all as specified. |
| 51 | Material and Labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed |
| 52 | Material and Labour for preparation of new or previously untreated plastered surfaces of wallsand applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage patternon one coat of primer complete all as specified and as directed |
| 53 | Material and Labour applying3mm thick wall care putty on newly plasteredsurface and prepare the smooth surface with sand paper and applying two coats of oil bound distemper on walls/Ceiling complete all as specified and as directed by Engineer-in-Charge |
| 54 | Material and Labour for new or old external wall surface by wire brushing/grinding in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with mechanical water nozzle with clean water & allow to dry. Fill visible cracks/ joints bycrack seal compound and epoxy base joint filler including resin and hardener in proportion as per manufactures instruction & allow to dry for 24 hours. Apply one coat of water base primer (with mechanically airless paint sprayer machine) and allow to dry for 6 hours appx. Thereafter apply 02 coats of WB high build anti carbonating coating cum waterproofing (with mechanically airless paint sprayer machine) & match with brush at the interval of 08 hours between the coat and allow to dry to match the existing shade in camouflagepattern including or plain paint necessary scaffolding necessary security for the workers for any height, covering etc complete all as per specified and directed. Note:- External water proofing treatment on wall at any height of the building including acrylic paint shall be applied by mechanically Airless paint sprayer machine only. |
| 55 | Material and LabourFormwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular in plan to provide rough finish surface to concrete |
| 56 | Material and Labour Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.with rough finished surface |
| 57 | Material and Labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dustand brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and directed |
| 58 | Material and Labour for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately. |
| 59 | Material and Labour for rendering 10mm thick in cement mortar 1:4 on roof top surface including WPC as per manufacturer instructions complete all as specified and as directed.Note : WPC will be measured separately |
| 60 | Material and Labour for cleaning the new surfaces concretewith wire brushing and applying water proofing treatment as under:-(i)Apply oil bound bitumen primer @ 0.50 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree Celsius on the prepared dry roof surface. (iii)Laying torch applied APP polymer modified membrane3mm thick with non-woven polyester mat as reinforcement weighing not less than 3.50 Kg/Sqm with white gravel/mineral finished by thermo fusion process all as described under particular specification(iv) Applyingtwo coats of bitumen water proofing aluminium heat resistance paint on the roof as per manufactureinstructions completeNotes :- Rates are included for Item No (i) to (iv) |
| 61 | Supplying only Liquid water proofing compound complete all as specified and directed by Engr-in-charge |
| 62 | PART II : WATER SUPPLY WORKSupply and fixing mild steel pressure sand filter for swimming pool with flow rate capacity 30 Mtr cube per hrs and filter unit with the following size. Leg size 27 to 30 inch tank length 69 inch to 70 inch and tank circumference 186 inch to 190 inch with complete material fitted inside the filter unit of tank such as strainer in bottom side and layer of gravels with different size 01 inch to 02 inch and 0.3 inch to 0.4 inch thickness of the both gravels as per suitable size. After that sand filling in filter plant 0.5 to 4 mm size and multiport valve with all necessary required items for control to sand filter.”Note“The testing certificate of water PH value and chemical properties should be provide by contractor through a govt approved lab after installations of sand filter. |
| 63 | Supply and fix Foot Valve conforming to IS 4038, 80 mm (3”) dia, complete all as specified and directed by Engr -in- Charge. |
| 64 | Cutting and dismantling the existing unserviceable rusted 80mm MS line at Chariot swimming pool filtration plant of 18 RM and replacing the MS special such as long bend – 5 Nos equal Tee-2Nos and replacement of u/s diaphragm type valve 1 No by new one. Carrying out cutting/welding/fabrication of new pipe as per site requirement to match with the filtration plant pipe line and valves. All steel portion to be painted with two coat of anti corrosive paint over one coat of anti corrosive primer. Assembling jointing & testing , complete all as specified and directed by Engr -in- Charge.Note:-1.MS Pipe, Valves will be measured and paid separately under relevant items of Schedule. 2.Cost of replacement of rubber gasket, nuts and bolts, Flange, fittingsetc is deemed to be included in quoted rate. |
| 65 | Supply , laying, testing and commissioning of MS ERWpipe class \"B\" in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 100 mm bore, complete all as specified and directed by Engr -in- Charge. |
| 66 | Supply , laying, testing and commissioning of MS ERW pipe class \"B\" in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 80 mm bore, complete all as specified and directed by Engr -in- Charge. |
| 67 | Supply and fixing sluice valve with flanged ends 100 mm bore cast iron body, flanged and drilled end non rising type , bronze spindle with nuts, as per IS 14846, ISI marked including all joints, class PN 1.6, complete all as specified and directed by Engr -in- Charge. |
| 68 | Supply and fixingbutterfly valve with matching flanges, gasket,all as specified and directed of 80 mm dia, complete all as specified and directed by Engr -in- Charge. |
| 69 | Supply and fixing in repair Non return valve (reflux valve) with by pass arrangements complete of size 100 mm dia with matching flanges, gasket, complete all as specified and directed by Engr -in- Charge. |
| 70 | Supply and fixing in repair Non return valve (reflux valve) with by pass arrangements complete of size 80 mm dia with matching flanges, gasket, complete all as specified and directed by Engr -in- Charge. |
| 71 | Supply and fix direct cylinder mounted type Vacuum chlorination chemical dozing system switch comprising dozing pump coupled with electric motor capcity upto 1 HP 1450 RPM assembly with agitator in one motor fitted on mild steel/ FRP tank capcity of tank 150 LTR including all necessary connected item and PVC pipe fitted with water pipe line which supply to swimming pool for pressure feed including all gauges, pump, motor conforming to IS 10553 part - 2 having capacity 1.0 to 1000gm/hr, complete all as specified and directed by Engr -in- Charge.Note “The pump motor and tank for chlorination and wiring of motor pump from electric connection to pump including above quoted rate. |
| 72 | Material and Labour forPVC Piping and Fittings for the ozonator to Filter to Pool inside the pump room with necessary pipings and control valves. Pipings in PVC 10 Kg Pressure, complete all as specified and directed by Engr -in- Charge. |
| 73 | Supply and fixing ofCentrifugal horizontalMonoblock pump set3 phase 440 Volt star delta startercapacity 7.5 HPflow rate 25 GPM at 5.5 Mtr headcomplete withchassis (MS) for mounted the pump set andPCC foundation nut bolt etc . also all consumable connectedfitting required at site including this quoted rate, complete all as specified and directed by Engr -in- Charge. |
| 74 | Supply and fixing CPVC pipe line size 80 mm diain center of swimming poolfor inlet water with complete fitting such as elbow nipple socket nut bolt etc. all as specified and directed by Engr -in- Charge. |
| 75 | Supply & fixingfloor inlet nozzles are installed on the bottom floor of the swimming pool which provides water to the pool, complete all as specified and directed by Engr -in- Charge. These floor inlets allow efficient water flow adjustments to desired level. |
| 76 | Supply and fixing 9\"\" Dia 40 mm Thickness 18 WATT SS White Rim Swimming Pool Light | Under Water Wall Mounted Light (Warm White) including connection with suitable wire, complete all as specified and directed by Engr -in- Charge. |
| 77 | Supply, installation, commissioning and testing of LT Feeder pillar ofsize 1Mx0.6 x0.60M (3.15 mm MS Sheet)factory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement,outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick mild steel CRCAsheet supported and fixed on structural frame of angle iron of size50 x50 x 6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type B1,suitable for 3 phase 4 wire system 415 volts grade consisting of Copper bus bar capacity of 300 Amps with necessary wiring with PVC sheathed stranded copper conductor of 1100 volts of appropriate length size with and including fixing lugs, bolts, screws etc complete including taking out old LT paneland comprising of the following accessories:-INCOMING :-(a) MCCB, 160 Amp, 4 Pole,36 KA - 01 No. (b) Digital Combimeter (7in1) with 4 digit LED Display -01 No (c) Indicating lamp LED type one set in incoming phase. (d) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volt grade IS 694 marked of appropriate gauge including all copper lugs.OUTGOING:-(a) MCCB, 63 Amp, 3 Pole, 36 KA - 03 No.(b) MCB, 32 Amp, 4 Pole, 16 KA - 01 No.(c) Star delta starter complete with single phase preventer cap of starter 7.5 HP (Notes : Make of panel, size and drawing shall be got approved from GE before placing order for procurement) |
| 78 | Material and Labour for earthing complete with galvanised steel earth plate electrodesize 600x600x6.0mm thick buried directly in groundvertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.5 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm dia by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Note : The unit rate includes for protection pipe and lead wire from top of earth plate up to 7.5 meter above ground level. |
| 79 | Supply and fixinggate valves, size 50 mm diawith iron wheel head, screwed both ends for iron pipe and fixed with pipe, complete all as specified and directed by Engr -in- Charge. |
| 80 | PART III : ELECTRIC SUPPLY WORKTaking down carefully copper /aluminium point wiring ( light, fan, socket or power) complete, withwiring accessories such as bend boards Elbows only, ceiling fittings etc and removing material to store for safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engr-in-charge. |
| 81 | Material and Labour for point wiring with 1.5 sqmm (nominal area) FRLSH PVC insulated and sheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium graderigid PVC conduit (ISI marked) concealed on wall surface with all accessories including1.5 sqmm size PVC insulated sheathed copper conductormultistranded cable FRLSHfor continuous earth conductor ( using green colour) to common earth and connecting to earth dolly, complete all as specified and directed by Engr-in-charge for the following :- (a) One light / Buzzer point controlled by one switch5 Amp, SP, one way240 volts.Note :- Necessary cutting and chasing of wall surface including making good surface deemed to be included in quoted rates. |
| 82 | (b) One fan/exhaust fan point controlled by one switch |
| 83 | (c) One 5 pin socket outlet 5 Amps on same board |
| 84 | (d) One 5 pin socket outlet 5 Amps on independent board |
| 85 | All as per item No 81.00 here-in-before but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board, complete all as specified and directed by Engr-in-charge. |
| 86 | Supply and fixswitch6 amp one way ISI markedcomplete all as specified and directed. |
| 87 | Supply and fix switch socket combination15/16 amp one way complete all as specified and directed. |
| 88 | Supply and fixsocket 5/6 amp one way complete all as specified and directed. |
| 89 | Supply and fix step type fan regulator 120 Watt ,220 volt ,50 HzISI marked complete all as specified and directed. |
| 90 | Supply and Fix ceiling rose, 3 phase/PVC/polycarbonate, isolated body, three terminals complete all as specified and directed. |
| 91 | Supply and fixing surface and wall mounted LED batten of20/22 W with polycarbonate housing & integrated electronic driver having THD<20%, complete all as specified and directed by Engr-in-charge. |
| 92 | Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 93 | Supply and Fix in repair/replacement6 to 32 AMP MCB single pole 240 V 10 KA(C-Series) complete all as specified and directed. |
| 94 | Supply and Fix in repair/replacement SPN 32 AMP MCB DP 240 V 10 KA(C-Series) complete all as specified and directed. |
| 95 | Material and Labour for wiring for circuits/sub main wiringwith FRLSH PVC insulate sheathed 2 x 6 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into concealed PVC conduitwith 6 sqmm FRLSH PVC insulated green copper cable for continues earth with suitable dia ofPVC pipewith all accessories complete all as specified and directed by Engr-in-Charge. |
| 96 | Material and Labour for wiring for circuits/sub main wiringwith FRLSH PVC insulate sheathed 2 x 4 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into concealed PVC conduitwith 4 sqmm FRLSHPVC insulated green copper cable for continues earth with suitable dia ofPVC pipewith all accessories complete all as specified and directed by Engr-in-Charge.(for geyser point) |
| 97 | Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, concealed on wallincluding taking out old unserviceable MCB DB any size/type. |
| 98 | Taking down of submain of any size, complete all as specified and directed by Engr-in-charge. |
| 99 | Taking down ceiling fan and keeping in safe custody for reuse and refixing the sameafter duly painted and marking of MESnumber onceiling fan of size 1200mm sweep complete with connected accessories as directed and specified by Engr-in-Charge. |
| 100 | Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protectionLED complete all as specified and directed by Engr-in-charge. |
| 101 | Taking down Exhaust fan and keeping in safe custody for reuse and refixing the sameafter duly painted and marking of MESnumber onceiling fan of size 1200mm sweep complete with connected accessories as directed and specified by Engr-in-Charge. |
| 102 | Supply and fix Cable with copper conductor 10sqmm 2 CORE PVC round sheathed (flexible) industrial cable saddle on wall surface including all accessories complete all as specified and directed by Engr-in-charge. ( for security light) |
| 103 | Supply, Install, Testing and Commissioningcubical type LTPanelfloor mounted OUTDOOR type for 415V, 3 phase 4 wire system 50 Hz AC supply, factory made fabricated from MS sheet totally enclosed, dust weather proof and vermin proof for outer shellhaving TPN aluminium bus bar rating 1.5 times that of controllingMCCB supported onbottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 2.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half and general construction confirming to IS-8623/93 and wall/floor mounted on suitable PCC foundation with following detailed specification & controlcomplete with suitable fixing accessories.OUTER SHELL :- The outer shell shall be made of 2.00 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of glands. INNER SHELL :-Inner shell made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air \"U\" type gasket shall be used to make the inner shell completely vermin proof and to accommodate incomer/outgoing MCCB\"s and TPN aluminium bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB\"s. including taking out old panelINCOMING : (1) MCCB 63 AMP 4 P 16 Kathermal magnetic based with o/c, s/c protection & ROH - 01 No. (2)Digital type Indicating lamps RYB-03 nos. OUT GOING :(1) 40 amp MCB SPN 100 mAwith enclosure - 3 Nos. Note :- Contractor should visit the site and to prepare panel as per size requiredto fit in below stair case complete all as specified and directed by Engr-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail