| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting,any gauge, thickness, includingNainital orsimilarpattern roofcoverings complete all as specified and directed. |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 4 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm eachcomplete all as specified and as directed by Engineer-in-charge. (Note for item No. 4.00 & 5.00- Rate shall be deemed to be include for cuttingholes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces). |
| 6 | Dismantling of timber scantlings 40 sq. cm unframed work and over in section, in any position complete all as specified and directed. |
| 7 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 8 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed. |
| 9 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge. |
| 10 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed. |
| 12 | Demolition of Stone slabs and tiles laid bedded and pointed in cement mortar of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 13 | Dismantling water tanks of capacity exc. 500 and not exc. 1000 litres, complete all as per specified and as directed by Engineer-in-charge. |
| 14 | Taking down eaves gutters and rainwater pipes CI/PVC/AC soil pipe including all fittings, heads, shoes, bends, swan-necks, etc. (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 15 | Taking up or down of 15 mm steel tubing and connections, including cleaning , complete all as per specified and as directed by Engineer-in-charge. |
| 16 | Taking up or down 20 mm steel tubing and connections, including cleaningcomplete all as per specified and as directed by Engineer-in-charge. |
| 17 | Taking up or down 25 mm steel tubing and connections, including cleaningcomplete all as per specified and as directed by Engineer-in-charge. |
| 18 | Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed. |
| 19 | M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 21 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 22 | M&L forPCC (1:3:6) type C-2 (using 40 mm graded crushed stoneaggregate) as in surface channel and drains complete all as specified and directed. |
| 23 | M&L for PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in in copping, bed plates etc of main holes, roof kerbs or mud stops, rounded or chamfered on edges include necessary formwork (straight or curved), complete all as specified and as directed by Engineer-in-charge. |
| 24 | M & L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge. |
| 25 | M&L forcement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamferedon edges including necessary form work finishing the surface even and fair with using extra cementcomplete all as specified and directed. |
| 26 | M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stoneaggregate) as in foundationsincluding rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified anddirected. |
| 27 | M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stoneaggregate)as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 28 | M&L for reinforcement cement concrete (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) as in chajja & challah hoods complete all as specified and directed. |
| 29 | Supply only Liquid water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge. |
| 30 | M&L for brick work with fly ash bricks straight or curved on plan in CM 1:4 as in half brick thick walls, complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L for fly ash brick work with bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. |
| 32 | S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 33 | S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge. |
| 34 | Supply and fixing of factory made partly glazed three panels i.e. upper panel will be wire mesh and further divided in to two panels fitted externally in the clear space & lower panel will be plain coloured PVC sheet 5mm thickand PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cementcomplete all as specified and as directed by Engineer-in-charge. |
| 35 | S & F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge. |
| 36 | S&F of floor door stopper 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge. |
| 37 | S&F 100 mm butt hinges stainless steel, complete all as per specified and as directed by Engineer-in-charge. |
| 38 | S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 39 | S&F of 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as per specified and as directed by Engineer-in-charge. |
| 40 | S&F of 250 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 41 | S&F of MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge. |
| 42 | S & F of Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed. |
| 43 | S&F in repairs of 25mm dia harrison rails /curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge. |
| 44 | Providing form work to sides of concrete foundation, footing, base of column, raft & plinth beam, sides and soffits of foundation and plinth beams and similar work, vertical or to batter for fair finished surfaces for flar surfaces complete all as specified and directed. |
| 45 | Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concretecomplete all as specified and directed. |
| 46 | Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed. |
| 47 | M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 48 | S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 49 | M&L for TMT bars5mmdia and over upto and including 10mm dia instirrups, spacers andbinders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 50 | S&F ofrolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality \"A\"complete all as specified and directed. |
| 51 | S&Ffor rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment ofFe 410-W (Gde E-250) quality -A including painted one shop coat of zinc chrome primer paint including preparation of surface at Contractor\"s workshop complete all as specified and directed. |
| 52 | S&F for mild steel screw bolts (machine made) 16 to 20mm with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolts exceeding 225mm but not exceeding 300mm complete all as specified and directed. |
| 53 | S&F framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 Gde-E-165, complete all as per specified and as directed by Engineer-in-charge. |
| 54 | S&F of Powder coatedaluminium window sliding type three track (2 glazed & one gauzed shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 4mm thick plain/tinted glass and aluminium mosquito proof gaugecomplete all as per specified and as directed by Engineer-in-charge. |
| 55 | S&F of powder coated anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm complete all as specified and as directed. |
| 56 | M&L for 4mm thick non asbestos fibre cement building boards (E-board) fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 57 | S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge. |
| 58 | S&F of pre-painted galvalume aluminium zinc coatingGI basedplain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed. |
| 59 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ footpath laid in panels and finished cement concrete surface even & fair etc including necessary form work complete all as specified and as directed by Engineer-in-charge. (Note:- Joints 12mm wide to full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.) |
| 60 | M&L for 100mm thick PCC 1:4:8, type D2 (using 40mm graded agg) as in sub base, complete all as per specified and as directed by Engineer-in-charge. |
| 61 | M&L for 100mm thick PCC 1:3:6, type C2 (using 40mm graded agg) as in sub base, complete all as per specified and as directed by Engineer-in-charge. |
| 62 | M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth with using extra cementcomplete all as specified and directed. |
| 63 | M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying over and including 50mm thick sand filling complete all as specified and directed. |
| 64 | S&F of coloured non-skid ceramic tiles 8 to 10mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge. |
| 65 | Ditto-all as per Item No.64.00 here-in-before but in skirting/dado, etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match with the shades of tiles over and including 10mm thick rendering in cement mortar 1:4complete all as specified and directed. |
| 66 | M&L for Machine cut Kota stone slab flooring 20mm -25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 67 | M&L for machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge. |
| 68 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigmint to match the shade of granite stone including griding & polishing with 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 69 | M&L for pre-polished coloured and chemically treated chequeredcement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20mm thick cement screed bed in cement mortar (1:4)after complete all as specified and directed. |
| 70 | M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor finished cement concrete surface even & fair etc including necessary form work complete all as specified and as directed by Engineer-in-charge. |
| 71 | M&L for rendering 20 mm thick on fair face of brick worksor concretesurfaces of wallswith cement mortar (1:4) in two layers (10mm thick backing coat + 10mm thick plaster) mixed with WPC @200ml per 50 Kg of cement on 10mm thick plaster, finished the surfaces even and smoothwithout using extra cement complete all as specified anddirected. (Note : WPC will be measured and paid separately) |
| 72 | M&L rendering 15 mm thick on other than fair faces of brick work or concrete block surface in cement mortar 1:6,surface to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge. |
| 73 | M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed. |
| 74 | M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge. |
| 75 | M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge. |
| 76 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 1mm thick wall care putty newly plastered surfaces of wall after and including preparation of surfaces complete all as specified and directed. |
| 77 | M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved grade complete all as specified andas directed. |
| 78 | S&F of rotational moulded polyethylene water storage tanks multi layer, (three layer)ISI Marked (cylindrical, vertical with closed top) of 1000 Litres capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed by Engineer-in-charge. |
| 79 | S&F in repairsof 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 80 | S&F in repairsof 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 81 | M&L for GI water tubing medium grade 15 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors , complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, in trench etc (surface or concealed type)complete all as specified and directed. |
| 83 | S&F of 25mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, in trenches, etc (surface or concealed type)complete all as specified and directed. |
| 84 | S&F in repairs ofsinkswith drainage board made of stainless steel 1mm thick kitchenor laboratory with plugs, washers andwastes;including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowlsize410mmx330mmx 160mm complete all as specified and directed. |
| 85 | S&F in repair of Bib taps long body fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge. |
| 86 | S&F in repair of 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge. |
| 87 | S&Fin repairs of 15mm dia pillar tap, fancy tpype, cast copper alloy with capstan heads, chromium plated,screweddown high pressure, with letter \"HOT\" or \"COLD\" with long screwed shanks & fly nuts, screwed for iron pipes completeall as specified anddirected. |
| 88 | S&F in repairs of 15mm dia, angle/stop valve, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 89 | S&F in repairs of floor trap of 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge. |
| 90 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joint laid in trenches or in floorcomplete all as per specified and as directed by Engineer-in-charge. |
| 91 | S&F of PVC (SWR) 110 mm bore bendscomplete all as per specified and as directed by Engineer-in-charge. |
| 92 | S&F of 110 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 93 | S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring jointslaid in trenches or in floor complete all as per specified and as directed by Engineer-in-charge. |
| 94 | Cutting existing steel tubing for alterations or additionsof 40/50mm dia bore for inserting of reducer Tee (Each cut measured) complete all as specified and directed. |
| 95 | Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power)complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed. |
| 96 | M&Lfor point wiringcomplete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. flush mountingMS box with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing ofmodular top cover , blankingplate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresmodular accessories of suitable modules andincluding 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathedsingle core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surfacecomplete all as specified and directedfor the following:- (Note:- (i) Allnecessary accessories such asmodular box, top cover plate, blank plate, MS box, screws, washers etcare deemed to be included with quoted rate and to be used of same make/brand onlyin relevant items.(ii) Cutting & chasingof wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.) |
| 97 | (a) One light point controlled by one switch . |
| 98 | (b) One fan/exhaust fan point controlled by one switch. |
| 99 | © One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on independent board . |
| 100 | (d) One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on same board . |
| 101 | S&F of modularswitch 10 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed. |
| 102 | S&F of metal box, 1 module, 240V, AC, complete all as specified and directed. |
| 103 | S&F of metal box, 3 module, 240V, AC, complete all as specified and directed. |
| 104 | S&F of metal box, 8 module, 240V, AC, complete all as specified and directed. |
| 105 | S&F of white cover plate with frame, 1module complete all as specified and directed. |
| 106 | S&F of white cover plate with frame, 3module complete all as specified and directed. |
| 107 | S&F of white cover plate with frame, 8module complete all as specified and directed. |
| 108 | M&Lfor point wiringcomplete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. flush mountingMS box with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing ofmodular top cover , blankingplate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresmodular accessories of suitable modules andincluding 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathedsingle core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surfacecomplete all as specified and directedfor the following:- (Note:- (i) Allnecessary accessories such as MS box, screws, washers etcare to be used of same make/brand onlyin relevant items.(ii) Cutting & chasingof wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.) |
| 109 | (a) One light point controlled by one switch. |
| 110 | All as per Item No.108.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmmfor one socket outlet 15/16 amps point on independent board complete all as specified and directed. |
| 111 | All as per Item No.108.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4 sqmmfor one socket outlet 15/16 amps point on independent board complete all as specified and directed. |
| 112 | S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked completeall as specified and directed. |
| 113 | S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed. |
| 114 | S&F ofsocket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI markedcomplete all as specified and directed. |
| 115 | S&F oflamp holder, insulated body with back plate for batten fittingsincluding 9 watts LED lamp complete all asspecified and directed. |
| 116 | S&F of modular fan regulator,electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed. |
| 117 | S&F ofceiling rose , three terminal, PVC/polycarbonate body, ISI marked completeall as specified and directed. |
| 118 | S&F of decorative typesurface mounted 1X20 watts LED light fitting with LED lamps 4 feet, 5700K including fixing arrangements at any heightwith nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of requiredsize with integrated high efficiency el;ectric driver and surge suppressor of 2KV or more lumen efficiency > 120lumens/watt, power factor >0.90, operating range 140 to 270 V, 50Hz complete all as specified and directed. |
| 119 | S&F of recess mounting 2\"x2\" LED 35/36 Watt light fittings with LED lamp and required driver, slimin class LED ceiling panel with best in class aestheticwhite powder coated frame blended seamlessly with ceiling layout modularceiling grid and also can besuspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cablefrom looping box to light fitting and testingcomplete all as specified and directed. |
| 120 | S&F of energy saving new generaation environmental friendly long life 35/36 watt LED street light fittingsIP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cableincluding taking down old unserviceable light fittings complete all as specified and directed . |
| 121 | Supply, fabricatedand fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.5 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for PCC/steel tubular poles/on wall surfaces including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed. |
| 122 | M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn through and including rigid PVC conduit of required sizemedium grade (MMS) with all connected accessories such asBend, Tee, Elbow, Short piecesetc concealed in wall/roofs/floorsand including one run of 6 sqmmsingle core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surfaceas requiredfor concealedwork including taking down old unserviceable submain wiring complete all as specified and directed .(Note : (i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (v) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.) |
| 123 | S&F ofpowder coated sheet metal enclosure 415 volts AC,TPNdistribution board 4 way suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth barand MCB incomer of rating upto 100 Amps,MCB TPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DBs completeall as specified and as directed. |
| 124 | S&F of powder coated sheet metal enclosure 240 volts AC,SPNdistribution board 4 wayfor flush mounting with 200 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 200 Amps, MCB SPN/DPand MCB SP, 10KAas outgoing and complete connecting cable linkswith top and bottom removable gland plates withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DB completeall as specified and as directed. |
| 125 | S&Fof powder coated sheet metal enclosure240 volts AC, SPNdistribution board 8 wayfor flush mounting with 200 Amps copper busbar, neutral bar, earth barand MCB incomer of rating upto 200Amps, MCB SPN/DPand MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable one completeall as specified anddirected. |
| 126 | S&F ofMCB, SP, 6 Amps to 32 Amps , \"C\" series, 240 Volt, 10KA, 50 Hz,completeall as specified anddirected |
| 127 | S&F ofMCB, SPN, 6 Amps to 32 Amps , \"C\" series, 240 Volt, 10KA, 50 Hz,completeall as specified anddirected |
| 128 | S&F of MCB TPN63 Amps, 10 KA, \"C\" series, AC, 240 volts, complete all as specified anddirected. |
| 129 | S&F of ceiling fan (BLDC) complete with fan blades down rod with electric regulator and accessories, 230v, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless directed current motorcomplete all as specified and directed. |
| 130 | S&F for exhaustfans, of sturdy engineering plastic of size 450mm sweep, 1200 RPM exhaust fan AC, single phase 230V/240Vas approved colour and connecting all electrical connections and testing including wall cutting and making hole for fixing of exhaust fan andmaking good the disturbed surfaces complete all as specified and directed. |
| 131 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings, fixtures such as switch, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fitting, regulators etc. anr refixing the same complete all as specified and as directyed. |
| 132 | S&F of CRCAkiosks box/pole junction box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 Amps with one NoMCB 10 Amps, SP having size 155x210x92 mm complete including making fixing arrangement with 9 mtr long swaged pole with flat iron clampincluding removing of old unserviceable item complete all as specified and directed by Engr-in-charge. (Make- Sintex/Star electric Eng Co./Universal switch gear control/Hensel) |
| 133 | M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nutsand washers of galvanisediron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposalof surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing completeall as specified and directed.(Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testingis deemed to be included with quoted rate). |
| 134 | S&F of 70 watt LED street light fittings, 230 V,IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary electric connection with suitable size copper cableafter and including taking down old unserviceable street light fittings complete all as specified and directed. |
| 135 | M&L for supply, erection and commissioning of steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screwes as specified type LT type 410 SP-31, (9m long) including placing at new location completeall as directed by Engineer-in-charge. (Note : Excavation, earth work and concrete work are not included in quoted rate and the same will be measured and paid seperately) |
| 136 | Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable completeall as specified and directed.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required) |
| 137 | Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable completeall as specified and directed.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required) |
| 138 | Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed. |
| 139 | Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed. |
| 140 | Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed. |
| 141 | M&L for brick covering with width equal to length of brick asprotection to cable with well burnt sub class ‘B’ bricks of size 230mm x 115mm x 75mm laid dry flat complete all as specified and directed. |
| 142 | M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured) |
| 143 | M & L for steel tubular LT pole paintingand removing from existing pole painting by using wire brush and using with emary paper and cleaning of steel tubular pole 9.00/9.50m long and GI brackets and cross arms in one coat of red oxide primer and two coat of aluminium oil paint, strip of yellow and black with numbering of pole in Round Shape with black/ yellow colour upto 1.2m height from bottom layer 30cm x 30cm, smooth finishing to satisfactory by Engr-in-Charge and painting work carryout at any height including all safety equipments and tools will be own arrangement and complete all as specified and directed. |
| 144 | Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed. |
| 145 | M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection including taking down old unserviceable pipe complete all as specified and directed. |
| 146 | S & laying or fixing or passing through pipe 1100 volts grade ISI marked, heavy duty cable with PVC insulator aluminium stranded 3 core conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 1.5sqmm nominal cross section in service connections including rigid PVC conduit ISI marked medium grade (MMS) with all connected accessories such as bend, tee, elbow, short peices etc. including making good the disturbed surfaces to match with existing surfaces and colour shade and testing complete all as specified and directed. |