| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 3 | M&Lfor 100mm thick plain cement conc type C-2, 1:3:6using 40 mm graded crushed stoneagg as in sub base complete all as specified and directed. |
| 4 | M&L for Sand filling under interlocking tiles or in foundations including watering and consolidation complete all as specified & directed. |
| 5 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006of 80 mm thickness M-35 Grade with grey cement complete all as specified and directed |
| 6 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified & directed |
| 7 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with hard/dense soils complete all as specified and directed. |
| 9 | Removing Excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 10 | M&L forplain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation filling, mass concrete complete all as specified and directed. |
| 11 | M&L for M-25 (20mm graded aggregates) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc; basement slabs, under-reamed piles and mass concrete complete all as specified & directed. |
| 12 | M & L for M-25 (20mm graded aggregates) for columns, pillars, piers, posts and struts complete all as specified & directed. |
| 13 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete flat complete all as specified & directed. |
| 14 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square or rectangular complete all as specified & directed. |
| 15 | M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | M & L for TMT bars 6mm to 8mm dia and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete al as specified and directed |
| 18 | M&L for rendering 10 mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces finished even and smooth without using extra cementcomplete all as specified and directed. |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 20 | M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle, Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed. |
| 21 | S&F MS plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with fixing attachment,Fe-290(Gde E-165) complete all as specified & directed by Engr-in-charge |
| 22 | S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self taping screws complete all as specified & directed. |
| 23 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to wall , fixed self tapping screwscomplete all as specified and directed. |
| 24 | M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed. |
| 25 | M&L for point wiring with 2.5 Sqmm PVCinsulated (FRLS) copper unsheathed single core multistranded copper conductor cable 1100 V grade drawn through rigid PVC conduit20 mm dia including provn of 2mm thick MS pressed steel terminal box of suitable size of flush to wall with 3 mm thick lmainated hylem top cover incl 2.5 sqmm copper conductor as earth wiring but for one 5 pin 15 Amps socket outlet point independent board. |
| 26 | S&F of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed |
| 27 | S&F switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed |
| 28 | S & F ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed. |
| 29 | S&F LED Flood light 30 W IP-65including MS clamps made out of flat iron and necessary nuts, bolts, washer as required complete all as specified and directed. |
| 30 | M&L for sub main wiring with 1.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated FR-LSH, unsheathed, copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated FR-LSH, unsheathed,copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly etc including making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed. |
| 31 | S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. |
| 32 | S&F MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified & directed. |
| 33 | S&F MCB SPN 32 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB \"C\" series complete all as specified and as directed. |
| 34 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wite 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point complete all as specified & directed. |
| 35 | Supply , Laying and testing cable XLPE insulated screened, PVC bedded, Galvanised steel srip or wire armoured electric power cable (Heavy duty) 1100 V Grade, aluminium conductor of size 25 sqmm 4 core complete all as specified & directed. |
| 36 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil complete all as specified & directed. |
| 37 | M&L for sand cushioning, spreading & levelling, watering and well ramming in layers not exec 25cm in soft/loose soil complete all as specified & directed. |
| 38 | Supplying & laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and directed. |
| 39 | GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified & directed. |