Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-02-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tilling including cement mortar bedding and rubbish off the premises complete all as specified and directed. |
| 2 | S&F for joint free non skid Ceramic tiles, coloured, 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 3 | S&F for glazed ceramic tiles, coloured 300x450x6 to 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surface including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 4 | S&F for vitrified tiles, light shade8 to 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 5 | S&F for vitrified tiles, light shade, 8 to 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surfaces such as Dado/Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed in CM 1:3 complete all as specified and directed. |
| 6 | S&F for heavy duty exterior finish pavement tiles, coloured, superior quality, 300x300x10mm thick as in floors/ pavement etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 7 | S&F for Machine cut kota stone slab flooring 18-20 mm thick over 15 mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 8 | S&F for Machine cut kota stone slab 12-15 mm thick as in riser of steps, skirting, dado and pillar over 10 mm thick rendering in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 9 | S&F for 15mm bore Steel water tubing \"medium grade\", galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor incl taking up or down old steel tubing and connections and removing to store or removing from site complete all as specified and directed. |
| 10 | S&F for 20mm bore Steel water tubing \"medium grade\", galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor incl taking up or down old steel tubing and connections and removing to store or removing from sitecomplete all as specified and directed. |
| 11 | Cutting chases in brick work, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc., and making good, (cutting not exc 10cm girth) complete allas specified and directed |
| 12 | S&F in repair rotational moulded,multilayer HDPE water storage tank (white colour) of 500 ltrs capacity(Cylindrical vertical with closed top)ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMTfloat valve epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed. |
| 13 | S&F in repair 5 mm thick bevelled edge looking mirror of selected quality glass, mounted on wall with and incl four Nos stainless steel studs of adequate size complete all as specified and directed. |
| 14 | S&F in repair PVC low level syphonic actionflushing cistern of 10 lit capacity including siphon, PVC float with ball valve, rubber cone and flush pipe,Brackets,450 long PVC connection pipe etc complete all as specified and directed. |
| 15 | S&F in repair SS Grating doom 125mm dia with waste hole of steel fixed on floor/nahani trap with cement mortar, complete all as specified and directed. |
| 16 | S&F in repair bib taps long body cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. |
| 17 | S&F in repair pillar taps 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 18 | S&F in repair Stop valves, cast copper alloy, screwed down, high pressure, with capstan head, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15mm bore, complete all as specified and directed. |
| 19 | S&F in repair fancy type Chromium plated brass stop cock/ angle valve for15mm bore pipe, fixed in repairs complete all as specified and directed. |
| 20 | S&F in repair20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 21 | S&F in repairs Tubular towel rail of brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 22 | S&F in repairs stainless steel soap dish (oval) type including ss screws and wooden/plastic cleats complete all as specified and as directed. |
| 23 | S&F in repair PVC connection 15mm dia and 45 cm long with 2 Nos PTMT nuts, complete all as specified and directed. |
| 24 | Supply only 32/40mm bore PTMT waste pipe of best quality,600mm long for wash basin, sink and urinal etc complete all as specified and directed. |
| 25 | S&F in repair SS shower rose 125 mm dia to 150mm dia with 190mm long arm, swivel joints, complete all as specified and directed. |
| 26 | S&F for SS peg set of four, fixed with PVC rowl plug and screws complete all as specified and directed. |
| 27 | Demolition and breaking up (salt glazed ware, AC, PVC) drain pipes of any diaset in cement mortar complete all as specified and directed. |
| 28 | S&F for 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to walls with and including suitable size PVC clamps complete all as specified and directed. |
| 29 | S&F for 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to walls with and including suitable size PVC clamps complete all as specified and directed. |
| 30 | S&F for PVC (SWR) bend any radius suitable for 110mm bore PVC pipe jointed with solvent complete all as specified and directed. |
| 31 | S&F for PVC (SWR) vent cowl, any radius suitable for 110mm bore PVC pipe jointed with solvent complete all as specified and directed. |
| 32 | S&F for PVC (SWR) bend any radius suitable for 75mm bore PVC pipe jointed with solvent complete all as specified and directed. |
| 33 | S&F for PVC (SWR) branch piece, single (single Y or T) equal or unequal suitable for 110mm bore PVC pipe jointed with solvent complete all as specified and directed. |
| 34 | S&F for PVC (SWR) branch piece, single (single Y or T) equal or unequal suitable for 75mm bore PVC pipe jointed with solvent complete all as specified and directed. |
| 35 | S&F in repair vitreous china counter sunk wash basin, white, oval shape of size 560 X 450mm fixed on stone including cutting for and pinning in endsin CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed. |
| 36 | M&L for Granite 15-18 mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ecment (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 37 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified. |
| 38 | S&F inrepair vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) squatting pan including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified anddirected. |
| 39 | S&F in repair vitreous china urinal, half stall type (flat back), of size 635x395x420mm, white, with grating and union for discharge pipe (excluding flushing cistern) including 32mm dia PTMT coupling and waste pipe, providing and fixing plugs, bedding urinal against wall in CM 1:2, with CP spreader etc complete all as specified and directed. |
| 40 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area n.exc 1.50 Sqmeach complete all as specified and directed. |
| 41 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exc 1.50 Sqm but n. exc 4sqm each complete all as specified and directed. |
| 42 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 X 100 mm single rebated comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 43 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 X 125 mm double rebated comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 44 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.(Note: stainless steel butt hinges shall be paid separately) |
| 45 | S&F for 30mm thickFACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as perS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc., manufacturer\"s specification & drawings complete all as specified and directed. |
| 46 | M&L for Forming jambs, etc. to openings in CM 1:6 , including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed. |
| 47 | S&F for factory made steel window with side hung shutter including projecting type hinges with steel handle, steel peg stay, complete with glazing bar, dovetailed or welded complete all as specified and directed. |
| 48 | S&F for factory made steel window with side hung shutter including projecting type hinges with steel handle, steel peg stay, complete without glazing bar, dovetailed or weldedcomplete all as specified and directed. |
| 49 | S&F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 50 | S&F for figured glass 4mm thick pin head type and glazing with oil putty in square n-exc 0.5 sqm in each pane complete all as specified & directed. |
| 51 | M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty in square n-exc 0.5 sqm in each pane complete all as specified & directed. |
| 52 | S&F for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 53 | M&L for mild steel framed work such as grills, grates etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding bolts,expanded metal (work to be executed any height)etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 54 | M&L for Making good under cills or over arches, lintels and bressummers including all pinning when necessary (in CM 1:6) complete all as specified and directed. |
| 55 | S&F for 125 mm long, 12 mm dia SS Dash fasteners for door frames etc incl necessary drilling etc complete all as specified and directed. |
| 56 | S&F for 250mm long SS, sliding door bolt withhasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections suitable for use with pad lock complete all as specified and directed. |
| 57 | S&F for 100 mm size SS butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 58 | S&F for 150mm size SS handle, fabricated type,fixed with screws complete all as specified and directed. |
| 59 | S&F for 200mm size SS tower bolt, fabricated type,fixed with screws complete all as specified and directed. |
| 60 | S&F for Rubber door seal 32mm wide with Aluminium strip of size 19mm wide fixed with machine steel screw with washer, complete all as specified and directed. |
| 61 | S&F for 300mm, Helical door springs including roller and roller plate complete all as specified and directed. |
| 62 | S&F in repair Stainless steel tubing of 25 mm dia for curtain rod fancy typewith brackets including end cap(wall to wall or flush to wall) for securing to curtain rod complete all as specified and directed. |
| 63 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc. complete all as specified and directed. |
| 64 | M&L for brick work with old size sub class-B bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 65 | Demolition of reinforced cement concrete (reinforcement cutas required to facilitate demolition) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 66 | M&L forProviding precast cement concrete Type B-1, 1:2:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed |
| 67 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 68 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 69 | M&L for Cement concrete1:4:8 type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed. |
| 70 | M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof padding,in leveling course, benching, mud stops etc, complete all as specified and directed |
| 71 | Taking down cement or cement lime plaster any description fromwalls/ceiling etc including racking out joints, hacking for key & scrubbing down with water including removing of debries out side of MOD land complete all as specified and directed. |
| 72 | M&L for rendering 15 mm thick in cm 1:4fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement mixed with liquid WPC @ 200 ml per bag of cement or as per manufacturer instruction complete all as specified and as directed. (Note: WPC will be measured and paid separatly.) |
| 73 | Supply only liquid Waterproofing compound complete all as specified and directed. |
| 74 | M&L for rendering 15 mm thick in cm 1:6 on on other than fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 75 | M&L for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surface of ceiling and finished surface even and smooth without using extra cement complete all as specified and directed. |
| 76 | S&F for Mild steel chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction, stretched firmly before plastering complete all as specified and directed. |
| 77 | M&L for preparation of newly plastered surfaces of wall and applying two or more coats of Acrylic Smooth exterior paint of required shadeapplied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed. |
| 78 | M&L for two coats of oil bound distemper over chalk whiting on newly plastered surface of wall and cornices including preparation of surfaces complete all as specified and directed. |
| 79 | M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed. |
| 80 | M&L for preparation of new or previously untreated surfaces of steel or Iron of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red Oxideprimer complete all as specified and directed. |
| 81 | M&L for 1 mm thick wall care putty on external and internal wall over newly plastered or old decorated surfaces complete all as specified and directed. |
| 82 | M&L forpreparing old paintedsurfaces of steelof any description not otherwise described,surfacesexc 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and directed. |
| 83 | M&L for complete removal of existing treatment and applying three coat of white wash on Ceiling incl preparation of surfaces complete all as specified and directed. |
| 84 | M&L for complete removal of existing treatment of wall and applying two coat oil bound distemper over a one coat of chalk whitingprimer complete all as specified and directed. |
| 85 | M&L for complete removal of existing treatment of wall and applying two coats of Acrylic Smooth exterior paint of required shadeapplied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed. |
| 86 | Demolition of mud in roof, any thickness including plastering and leaping ( where full thickness recoved or only a part there of disposal off rubbish upto a distance n.exc 100m, complete all as specified and directed. |
| 87 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof curbing, padding over roof slab complete all as specified and directed. Note - Average thickness shall not exceed 40mm. |
| 88 | M&L for rendering 10 mm thick on concrete surface when concrete is green on roof surface in cement mortar 1:3 mixed with water proofing compound @ 200 ml per bag of cement or as per manufacturer\"s instructions all as specified and directed.(Note : WPC shall be measured & paid separately) |
| 89 | Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, SmartCare PU Magnum membrane with an elongation of 450% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure asper DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare PU Magnum or approved equivalent in two coats with a consumption of 1.5 Kg per SQM on a primed surface withSmartCare Primer and a 40 GSM geo textile cloth sandwiched in between, etc., complete as perManufacturer\"s specifications |
| 90 | Removing of surplus excavated/demolised materilas to a distance exc 50m and n exc1.5 km away complete all as specified and directed by Engineer-in-charge. Note: Demolished material should not be thrown away on the ground from the top of roof, it should be removed from the roof by manually or by any mechanical means |
| 91 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 92 | S&F for 4mm thick E-boards tiles false ceiling with powder coated GI snap grid frame work including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B0/Cement mortar 1:3 complete all as specified and directed including all necessary drilling and necessary arrangement to fix electrical items as under:- (a)25x25x1.6 mm thick GI angle powder coated duly plugged @ 600mm centre to centre along perimeter of wall.(b)25x25x1.5 mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders with adjustable clamps and dash free fasteners plugging in RCC slab placed @ 600mm centre to centre from perimeter of wall. (c)Fixing of 4 mm thick E-boards tiles of size 595 mm x 595 mm of approved texture complete NOTE: The complete ceiling work shall be done as per manufactures instruction and as directed. |
| 93 | M&L for Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed. |
| 94 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 95 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming toFe-290 grade E-165 complete all as specified and directed. |
| 96 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 97 | S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 98 | Dismantling posts or struts (wood, steel or R.C.C.) any section, Posts embedded in Concrete, brick work, masonary etc including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 99 | Excavation in post holes ( or similar holes) in soft / disintegrated rock each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n.exc 50 M complete all as specified and directed. |
| 100 | M&L for Plain cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttrresses, columns, pillars, boundry pillars and posts (including, caps and bases) complete all as specified and directed. |
| 101 | M&L for treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc area n exc 0.1 sq. m each and treated with or coal tar black paint complete all as specified and directed. |
| 102 | S&F for Mild steel work as in swan necks for fencing, posts and struts including cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe- 290-Gde E-165 complete all as specified and directed. |
| 103 | M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified and directed. |
| 104 | M&L for Preparation of new steel surfaces of any description not otherwise described n exc 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified and directed. |
| 105 | Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards , rails , straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 106 | Supply only Chain Link MS galvanised fencing, diamond square type, complete all as specified and directed. |
| 107 | S&F in repair Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standrad rails straining bolts, including, securing or typing at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured). |
| 108 | S&F for stainless steel tubing of 25mm dia for curtain rod fancy type with heavy duty brackets and end caps (wall to wall or flush to wall ) for securing to curtain rod incl SS screws of suitable size etc Complete all as specified and directed. |
| 109 | M&L for preparation of old decorated plastered or unplastered surface of wall and applying one coat of oil bound distemper complete all as specified and directed. |
| 110 | Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket, light fitting etc; for creditand making good disturbed surfaces of walls, ceilings etc complete all as specified and directed. |
| 111 | M&L for point wiring with concealed in wall 1.5 sqmm (nominal area) FRLSH PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade of appropriate size concealed in wall and modular sunken box, cover plate/frame any module as required at site with all accessories as specified including 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dollyfor fan / light / exjaust fan/ bell point controlled by one switch and single conduit shall be used for each circuit complete all as specified and directed.Note:- 1. Cost of PVC conduit, with connected item to be included in the quoted rate.2. M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.3. Modular metal box, cover plate & frame for any module to be included in the quoted rate. |
| 112 | Description same all as per item No. 111here-in- before but for 3 pin 5 Amps switch socketon independent board with 1.5 sq mm copper cable complete all as specified and directed. |
| 113 | Description same all as per item No. 111here-in- before for 3 pin 15 Amps switch socket n on independent board with 2.5 sq mm copper cable including 2.5 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth complete all as specified and directed. |
| 114 | Description same all as per item No. 111here-in- before for 5 Amps socket point on the same board controlled by one switch complete all as specified and directed. |
| 115 | S&F for modular switch 1 way, 6 amps, 230V AC, one waycomplete all as specified & directed. |
| 116 | S&F for modular socket out let 2-in-1, 3 pin, 6 amp flush type 2 module complete all as specified & directed. |
| 117 | S&F for modular switch flush type 16 amps, 230V AC single pole one way complete all as specified & directed. |
| 118 | S&F for modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module complete all as specified & directed. |
| 119 | S&F for ceiling rose surface backelitethree terminals complete all as specified and directed.Make Anchor/havells/legrand |
| 120 | S&F for modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, socket size incl connection completecomplete all as specified & directed. |
| 121 | Supply and fixing in replacement of Decorative ultra slim square profile LED lighting fixture 20W, 120 lumen per watt (inverter type ) 4\" long batten with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with all assoceries intenallt prewired &includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable forand mounting clamps complete all as specified and directed. |
| 122 | Supply and fixing and replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface/recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 123 | Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet (inverter type ) long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. |
| 124 | S&F on wall building security light luminaire for 1x35 w LEDwith deep drawn housing complete with and including cable for connection from ceiling rose with3 core 1.5 Sqmm PVC insulated stranded copper conductor including bracket made out of 32 mm bore GI Light grade 1.20 M long to required shape as in bracket for to shape fixed on wall/pole with two pair of MS flate iron clamp of size50mm X 6 mm thickness of required shape with nuts, bolts and washers including painting complete and taking down unserviceable one complete all as specified and directed. |
| 125 | Taking down carefully ceiling fan/Exhaust fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl bladesand repair, servicing, paiting and after repair to fix same place complete all as specified and as directed. |
| 126 | S&F in replacment offactory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-43),(IK-09) suitable for mountingMCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar, TPN 4 ways 415volts complete all as specified and directed.Note: MCB/ shall be measured and paid seperatly under respective item of this schedule |
| 127 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single polescurrent carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 128 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of Triple poles & Neutral current carrying capacity 63/100 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 129 | S&F in replacment offactory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42), suitable for mountingMCBs confirming to IS-13032, IS-8623, BS-5484 with min 100 Amps rating copper bus bar SPN 8 ways, 220 volts complete all as specified and directed.Note: MCB/ shall be measured and paid seperatly under respective item of this schedule |
| 130 | S&F in replacment offactory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42), suitable for mountingMCBs confirming to IS-13032, IS-8623, BS-5484 with min 100 Amps rating copper bus bar SPN 4 ways, 220volts complete all as specified and directed.Note: MCB/ shall be measured and paid seperatly under respective item of this schedule |
| 131 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 132 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 133 | M&L inreplacment oftwo single core (submain) FRLS PVC insulated cable of6.00 Sqmm nominal dia and one single core green PVC insulated copper conductor earth continuity cable of 6.00 sqmm nomianal dia as mentioned below is drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 /25mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.Note :- (I) The cost for cutting, chases required and suitable lugs shall deemed to be included in the quoted unit rate.(II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM |
| 134 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia asearth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes(i)The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I(ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire andGI pipe for protection of earth wire. Any varriation in quantity shall be adjusted. |
| 135 | Schedule of Credit (MINUS) Rs. 53,479.50 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy