| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. GROUP-C |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modularm socket outlet and 15/16 amps modular switch, connection etc. as required |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 5 | 2x2.5 sq.mm+1x2.5 sq.mm earth wire |
| 6 | 4x2.5 sq.mm + 2x2.5 sq.mm earth wire |
| 7 | 2x4sq.mm+1x4 sq.mm earth wire |
| 8 | 4x4sq.mm+2x4 sq.mm earth wire |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 10 | 3x2.5 sq.mm |
| 11 | 6x2.5 sq mm |
| 12 | 3x4sq.mm |
| 13 | 6x4sq.mm |
| 14 | 3x6sq.mm |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 amp switch |
| 17 | 3 pin 5/6 amp socket out let |
| 18 | 15/16 amps switch . |
| 19 | 6 pin15/16 amp socket outlet |
| 20 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 21 | 8 way Double door |
| 22 | 12 way Double door |
| 23 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 24 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 25 | 40 amps |
| 26 | 63 amps |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 28 | Providing and fixing following rating and breaking capacityand pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 150 A, 16 KA,TPMCCB |
| 29 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 30 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 31 | 3 Module (100 mmX75 mm) |
| 32 | 6 Module (200 mmX75 mm) |
| 33 | 8 Module (125 mmX125 mm) |
| 34 | 12 Module (200 mmX150 mm) |
| 35 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 36 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 37 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required . |
| 38 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 39 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 40 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm)18- 22 watt |
| 41 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum). |
| 42 | LED FloodLight, powdercoatedpressurediecastaluminum(Systemlumenefficacy>135 lm/Watt)Supplying,installation,Testing&CommissioningofFloodLight, powdercoatedpressuredie cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP-66,IK-10,CRI>80,undervoltageandovervoltageprotection, EMI-EMCasper CISPR-15,lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained tilllife ends as perLM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <5, Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be ofrelevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Wattoutput . LM79 & LM80 Test reportfromNABLlab foralltestingrequired forLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) 100 watt |
| 43 | Supply ofXLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KVgrade Conforming to IS 7098of following Sizes 2 x 6 sq mm |
| 44 | P/f of Hot press sheed moulded compound (SMC) Fireretardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200xl60x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/lsolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with 55 back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd. |
| 45 | Supply of 12\"(300m) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required |
| 46 | supply, installation, testing and commissioning ofSingle/threephase Mono Block P/Set complete with all accessories workable on 240/415 volt. 50 Hz AC supply .(a) 1HP (0.75 KW ) Single Phase Pump Set Head frame 12.5 mt upto 25 mt Suction and delivery 25x25 |
| 47 | Providing and fixing ABC(Aluminium Phosphate) Power type fire extinguisher of 6 kgs capacity complete in all respect with ISI mark i/c fixing arrangement etc as required. |
| 48 | Providing and fixing 4.5 kg Co2 type fire extinguisher sqeeze grip type,trolly wheel as well mounting type complete in all respect with isi mark i/c fixing arrangement etc as required. |
| 49 | SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color |
| 50 | supply and installation at approved location approved make 4 nos. fire buckets of 24 guage galvanised steel, painted white inside and red outside and back on the bottom inscribed with letter \"FIRE in black and gold including stand fabricated out of sheet metal(16 guage) shade platform and associated civil works, painting etc as approved by fire authority. |
| 51 | Supply, Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400 A to 630 A with heat shrinkable colour coded sleeves suitable for accommodating MCCBs/MCBs/lsolators as incoming and outgoing as required (without MCCBs/MCBs/lsolators) complete with digital meter Module, including Voltmeter, Ammeter with selector switch, CTs control fuse andindicating lights including connections etc. as required (conforms to 15:8623). I/c removing the existing panel etc and reconnecting the inputs to existing submain |