| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ingle core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group \"A\" |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSPVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying & drawing following sizes of FRLS PVC insulatedcopper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd. |
| 6 | 1 x 1.5 Sq.mm.. |
| 7 | 3 x 4 Sq.mm.. |
| 8 | Supply and drawing of telephone wire of 2 pair 0.50 mm dia copper conductor FRLS PVC insulated unsheathed twisted wire jelly filled in existing / surface concealed conduitas reqd.including numbering and connectingthe wires at both the ends. |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 20 mm |
| 11 | 25 mm |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 5/6 amps switch |
| 14 | 15/16 amp switch |
| 15 | 3 pin 5/6 amp socket outlet |
| 16 | 6 pin 15/16 amp socket outlet |
| 17 | Telephone socket outlet |
| 18 | TV antenna socket outlet |
| 19 | Bell push |
| 20 | USB Type A & C Socket outlet(Make Legrand) |
| 21 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 23 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 24 | 1 or 2 Module (75mmX75mm) |
| 25 | 3 Module (100mmX75mm) |
| 26 | 6 Module (200mmX75mm) |
| 27 | 8 Module (125mmX125mm) |
| 28 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 29 | 1 or 2 Module |
| 30 | 3 Module |
| 31 | 6 Module |
| 32 | 8 Module |
| 33 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 34 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 35 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 36 | Single pole 5 A to 32 A |
| 37 | S & F, connecting and commissioningof following contactor in existing enclosure including drilling holes making thread/ nut bolts etc. as required complete. |
| 38 | 4 pole AC 1 rating 32 A (MCX03) |
| 39 | S&F, Copper tube / reducer/ lugterminals suitable for following size of conductor. |
| 40 | 6 /10/16 Sq.mm. |
| 41 | Supply, Installation, testing & commissioning of AC ceiling fan of following sweeps, aluminium die cast body , copper wound, double bearing, less 70 watts220 volts 50 Hz withoutregulator I/c wiring the down rods of standard length up to 30 cm with 1.5 sq.mm. PVC insulated copper conductor single core cable etc as reqd. ( ISI marked.) |
| 42 | 1200 mm Make_Bajaj Kassel/or approved Make. |
| 43 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-incharge.e etc. as reqd |
| 44 | Supply, fixing, testing and commissioning domestic fresh air ventilation fan, 150 mm dia,plastic body,1Ǿ AC power supply,50 Hzcomplete as required. |
| 45 | Supply,Installation,Testing and commissioning of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as requiired. |
| 46 | LED light fitting (Integrated) 20 watt with AL-Batten, =>125Lm/w, Make Crompton(Bright linea) or approved Make. |
| 47 | Wall bracket fitting for B_22 with LED bulb (make cromptonor equivalent approved make) |
| 48 | Wall bracket wooden base with 9 watt LED bulb (Decorative Cat. No.5990/L or equivalent approved make). |
| 49 | LED Ceiling Light 6 watt FR-plastic_housing (round/square shape), Make Crompton-Royal Rimless-R (Cat No. LCRP-06-CDL) or equivalent approved make |
| 50 | LED Ceiling Light 12 watt FR-plastic_housing (round/square shape), Make Crompton-Royal Rimless-R (Cat No. LCRP-10-CDL) or equivalent approved make |
| 51 | Picture light fitting chrome 10W. (Make Philiphs (Cat.No 48043)or equivalent approved make |
| 52 | Supply fixing connecting & commissioning of following rating ISI marked 3 pin Plug top Anchor make as reqd complete. |
| 53 | 15 Amp |
| 54 | Supplying and Fixing Gyser inlet and outlet flexible water pipe 450 mm long. |
| 55 | Supply and Fixing of geyser vertical type of following capacity complete as required (Make_ Racold CDR/ Platinumor its equivalent make). |
| 56 | 25 litrs. Capacity |
| 57 | Fixing of geyser vertical/Horizontal type of capacityupto 50 ltrs including supplying and fixing of flexible pipe and nut/bolts/washers complete as required. |
| 58 | Supply,installation, testing and commissioning 15 A key card switch 2 module 6772 53 with 2 M plate (Make_Legrand_cat no.6772 53) or equivalent approved make. |
| 59 | Supply,installation, testing and commissioning only key fob credit card size for switch 6772 53 (Make_Legrand_cat no.6772 55) or equivalent approved make. |
| 60 | Locating fault in wiring rectifyingremoving &restoring supply the same & making good the damages etc as reqd. |
| 61 | Dismantling of geyser of vertical/Horizontal type upto 50 litre capacity complete as required. |
| 62 | Dismantling the old MS/ PVC conduit pipe of all sizes from surface/recessed & making good the damages I/c filling the holes of the surfaceand depositing the same as reqd. |
| 63 | Dismantling the old wood batten/PVC casing capping of all sizes from surface & making good the damages I/c filling the holes of the surfaceand depositing the same as reqd. |
| 64 | Dismantling of switch board/MS/PVC boxes of any size up to 250x300 mm on surface/ recessedincluding making good andpainting with enamel paint etc as reqd |
| 65 | Dismantling, disconnecting old damaged unserviceable fitting/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. |