| 1 | Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc . In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift |
| 2 | Providing and laying in position cementconcrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 fine aggregate : 10 graded stone aggregate 40mm nominal size) |
| 3 | Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars Fe -500D or more |
| 4 | Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level excluding the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size) |
| 5 | Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs, landings, balconies and access platform |
| 6 | Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 fine aggregate) |
| 7 | Half brick masonry with common burnt clay F.P.S.(non modular) bricks of class designation 3.5 insuperstructure above plinth level upto floor V level -cement mortar 1:4 (1 cement : 4 fine aggregate) |
| 8 | Providing and fixing 18mm thick gang saw cut,mirror polished, premoulded and prepolished,machine cut for kitchen platforms,vanity counters,window sills,facias and similar locations, of required size, approvedshade,colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 fine aggregate), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels - Granite stone slab of colour black, cherry/ ruby red - area of slab over 0.50 sqm |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 fine aggregate) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 10 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type , core of block boardconstruction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters - 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 11 | Extra for providing lipping with teak woodbattens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 12 | Providing and fixing aluminium sliding door bolts , ISI marked , anodised ( anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade , with nuts and screws etc complete - 300 X 16 mm |
| 13 | Providing and fixing aluminium tower bolts , ISI marked ,anodised (anodic coating not less than grade AC 10 as per IS:1868) , transparent or dyed to required colour or shade , with necessary screws etc. complete - 300 x10 mm |
| 14 | Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,with necessary screws etc, complete - 125 mm |
| 15 | Providing and fixing aluminium hanging floor door stopper ,ISI marked , anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc complete - Twin rubber stopper |
| 16 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi - chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 + or - 0.2 mmthick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile ,zinc alloy (white powder coated) touch locks with hook , zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I. fastners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile offrame & sash shyall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality , all complete as per approved drawing.(Single / double glass panes , wire mesh and silicon sealent shall be paid separately) - Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels ) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 + or - 0.2 mm and single glazing bead of appropriatedimension.(Area of window upto 1.75 sqm) - sliding window size 1.20x1.35 m |
| 17 | Providing and fixing M.S.grills of required pattern in frames ofwindows etc with M.S. flats , square or round bars etc.including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc |
| 18 | Supplying and fixing rolling shutters of approved make, made of required size M.S.laths,interlocked together through their entire length and jointed together at the end by end locks , mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to ISS :4454 -part 1 and M.S.top cover of required thickness for rolling shutters - 80 x 1.20mm M.S.laths with 1.20 mm thick top cover |
| 19 | Steel work in built up tubular (round,square or rectanglarhollow tubes etc.) trusses etc., including cutting,hoisting,fixing in position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc. complete - hot finished seamless type tubes |
| 20 | Steel work welded in built up sections / framed work , including cutting,hoisting, fixing inposition and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate |
| 22 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specifed by the manufacturere) wirh water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 (one cement : 4 fine aggregate) jointing with grey cement slurry @3.3 kg per sqm including grouting the joints with white cement and matching the pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge. Clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily - Glazed vitrified tiles Matt / Antiskid finish of size - size of tile 600x600mm |
| 23 | Providing and fixing on wall face unplasticised rigid PVC rainwater pipes conforming to IS: 13592Type A, includingjointing with seal ring conforming to IS : 5382, leaving 10mmgap for thermal expansion, (i) Single socketed pipes - 110 mm diameter |
| 24 | Providing and fixing on wall face unplasticised - PVC mouldedfittings / accessories for unplasticised rigid PVC rain waterpipes conforming to IS:13592Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Coupler - 110mm |
| 25 | Providing and fixing on wall face unplasticised - PVC mouldedfittings / accessories for unplasticised rigid PVC rain waterpipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single teewithout door-110x110x110mm |
| 26 | Providing and fixing on wall face unplasticised - PVC mouldedfittings / accessories for unplasticised rigid PVC rain waterpipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion -shoe (plain) -110mm shoe |
| 27 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 fine aggregate) and making good the wall etc., complete - 110mm |
| 28 | Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine aggregate) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 fine aggregate) and finished neat complete |
| 29 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineerin- Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total Coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 30 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTMC 1549 and ASTMC 1371 respectively), VOC less than 10cc/gm. The coating thickness and the methodology of application shall be stictly as per manufacture\"s specification and as approved by Engineer-in-charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc. washing with water all complete .The contractor shall give guarantee for the performance of SRI and also the durablity of coating, all complete as per direction of Engineer-in-charge. |
| 31 | 20mm cement plaster of mix -1:4 (1 cement : 4 fine aggregate) |
| 32 | Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade - New work (two or more coats applied @1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @0.90 litre / 10sqm) |
| 33 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine aggregate) |
| 34 | Painting with synthetic enamel paint of approved brand andmanufacutre to give an even shade - Two or more coats on new work |
| 35 | Applying priming coat - with ready mixed red oxide zincchromate primer of approved brand and manufacture on steelwork (second coat) |
| 36 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 37 | Wall painting with premium acrylic emulsion paint of interiorgrade, having VOC (Volatile Organic Compound) content lessthan 50 grams / litre of approved brand and manufacture ,including applying additional coats wherever required to achiveeven shade and colour - Two coats |
| 38 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content - with water thinnable cement primer on wall surface having VOC content less than 50 grams / litre |
| 39 | Applying priming coatswith primer of approved brand andmanufacture, having low VOC (VolatileOrganic Compound ) content - with ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50grams / litre |
| 40 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade- One or more coats on old work |
| 42 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story height made with 40 mm dia .M.S.tube 1.5m centre to centre , horizontal & vertical tubes joining with cup & lock system with M.S.tubes, M.S.tube challies, M.S.clamps and M.S.staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safetyfeatures for the workmen etc.complete as approved. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. (Note: This item to be used for maintenance work judicically, necessary deduction for scaffolding in the existing item to be done.) |
| 43 | Raking out joints in lime or cement mortar and preparing the surface for repointing or replastering , including disposal of rubbish to the dumping ground all complete as perdirection of Engineer-in-charge |
| 44 | Flush pointing with cement mortar 1:3 (1 cement : 3 fineaggregate) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska - with F.P.S. brick tiles |
| 45 | Demolishing R.C.C work manually / by mechanical meansincluding stacking of steel bars and disposal of unserviceablematerial within 50 metres lead as per direction of Engineer-in charge |
| 46 | Demolishing brick work manually / by mechanical meansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction ofEngineer-in-charge.- in cement mortar |
| 47 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm |
| 48 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 49 | Providing and fixing white vitreous china laboratory sink with C.I.brackets , C.P.brass chain with rubber plug , 40mm C.P.brass waste and 40mm C.P.brass trap with necessary C.P.brass unions complete , including painting of fittings and brackets, cutting and making good the wall wherever required - size 600x450x200 mm |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings , with one step CPVC solvement cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-incharge- Concealed work , including cutting chases and making good the wall etc - 25 mm nominal dia pipes |
| 51 | Providing and fixing Chlorinated Polyvinnyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings includingfixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-incharge-internal work - exposed on wall - 50mm nominal diapipes |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer-in-charge- external work - 65 mm nominal dia pipes |
| 53 | Providing and fixing gun metal gate valve withC.I.wheel of approved quality (Screwed end) - 50 mm nominal bore |
| 54 | Providing and fixing gun metal gate valve with C.I.wheel ofapproved quality (Screwed end) - 65mm nominal bore |
| 55 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore |
| 56 | Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes - 110mm diametre |
| 57 | Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee with door - 110 x110x110 mm |
| 58 | Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110 mm |
| 59 | Providing and fixing glazing in aluminium door, window , ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the direction.( cost of aluminium snap beading shall be paid in basic item) - with float glass panes of 5 mm thickness |
| 60 | Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by providing weather silicon sealent over backer rod of approved quality as per architectural drawingsand direction complete - Upto 5 mm depth and 5 mm width |
| 61 | Grading roof for water proofing treatment with - Cement concrete 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 20 mm nominal size) |
| 62 | Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction ofEngineer-incharge- 50 mm average thickness |
| 63 | Chipping of unsound / weak concrete material from slabs , beams, columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-incharge - 25 mm average thickness |
| 64 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete as per direction of the Engineer-incharge- Bars upto 12mm diameter |
| 65 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 26.31.1 SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 66 | Providing , mixing and applying SBR polymer (of approved make ) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded fine aggregate with polymer minimum 2% by wt.of cement used) as per specifications anddirection. Note: Measurement and Payment : The Pre-meaurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crusing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers |
| 67 | Laying of non shrink free flow micro concrete renderoc RG or equivalent in the proportion 1:1 (One renderoc Rg: one graded stone aggregate of 12.5mm and below through the drilled holes till the voids and damaged area are completely filled and set to an average thickness of 50mm as directed by the Engineer in Charge. |
| 68 | Providing leak proof centering and shuttering using 25mm thick plywood for damage slab / beam to carring out micro concreting work including ceiling the gaps if any with renderoc plugging compound and removal of form work |
| 69 | Supplying and filling in plinth with M- sand under floors, including watering ,ramming consolidating and dressing complete |