| 1 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 2 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 3 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 4 | Float glass panes |
| 5 | 4 mm thick glass pane (weight not less than 10 kg/sqm). |
| 6 | Providing and fixing ISI marked IS:1341 M.S. pressed butt hinges bright finished with necessary screws etc. complete: |
| 7 | 125x65x2.12 mm |
| 8 | 100x58x1.90 mm |
| 9 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 10 | 300x16 mm |
| 11 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 12 | 300x10 mm |
| 13 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 14 | 125 mm |
| 15 | 100 mm |
| 16 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge. |
| 17 | Providing and fixing factory made PVC door shutter made of solid foam PVC profiles of thikness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top/ bottom/ lock) rails of minimum cross section of 70mmx 28mnn, of shape and design as per manufacturer\"s specificationshavinghomogenous finecellular structureandsmooth integral outer skin, inserted with G.I. \"C\" section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stifeners as per manufacturer\"s specifications Mitred cut joints for styles and rails provided with telescopic polymeric I\" corners are jointed together using solvent adhesive and strenghtened with fully threaded stainless steel screws (of required size) through reinforced stifener with paneling of specified solid foam PVC board/ high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded beadings of required size using PVC solvent adhesive/ cement. The finished door shutter including SS hardware, 1 no. ss sliding bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10 mm and 2 nos. SS handles 125mm, shall be fixed to frame with 3 nos. stainless steel hinges of minimum size 100x58x1.9 mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge. (Cost of above hardware is inclusive in rates) |
| 18 | 5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturer\"s specifications ( to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type. |
| 19 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 20 | 40 mm thick with 20 mm nominal size stone aggregate |
| 21 | Providing andlayingCeramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 22 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 23 | 0.63 mm thick with zinc coating not less than 275 gm/ m2 |
| 24 | Providing and fixing of 40 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement: 3 coarse sand). |
| 25 | 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 26 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 nnm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 27 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 28 | Ridges plain (500- 600mm) |
| 29 | 12 mm cement plaster of mix: |
| 30 | 1:4(1 cement: 4 fine sand) |
| 31 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 32 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 34 | Two or more coats on new work |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 36 | One or more coats on old work |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 38 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 39 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. |
| 40 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 41 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 42 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 43 | Of area 3 sq. metres and below |
| 44 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 45 | Of sectional area below 40 square centimetres |
| 46 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 47 | G.S. Sheet |
| 48 | Asbestos Cement sheet |
| 49 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : |
| 50 | Thickness above 10 mm up to 25 mm |
| 51 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 52 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 53 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 54 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 55 | W.C. pan with ISI marked white solid plastic seat and lid |
| 56 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 57 | Kitchen sink with drain board |
| 58 | 510x1040 mm bowl depth 250 mm |
| 59 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 60 | Semi rigid pipe |
| 61 | 32 mm dia |
| 62 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 63 | 20 mm nominal dia Pipes |
| 64 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 65 | 30 cm length |
| 66 | 15 mm nominal bore |
| 67 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 68 | 15 mm nominal bore |
| 69 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 70 | Standard hard wood cat-II(A) |
| 71 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : |
| 72 | Standard Hardwood Cat-II \"A\" |
| 73 | Providing wood work in post, truss, purlins, rafter, strut etc with superior class hard wood cat-II \"A\" |
| 74 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hingesof required panelling which will be paid for separately all complete as per direction of Engineer-in-charge [Note Butt hinges and necessry screws shall be paid separately |
| 75 | Standard Hardwood Cat-II \"A\" |
| 76 | Providing and fixing 25mm thick wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with |
| 77 | Superior class hard wood cat-ii ‘A’ |
| 78 | Providing and fixing wooden moulded beading to door windows frames with iron screws, plugs and priming coat on unexposed surface etc complete (a) Standard hard wood cat-II(B] 50x12mm |
| 79 | Providing and fixing PVC Nani Trape (110mmx75mm) approved quality. |
| 80 | Providing and fixingC.P. Angular stop cock weighing not less than 85gms of approved make perryware , including fittings,cutting and making good the walls wherever require : |
| 81 | 15mm nominal bore |
| 82 | Providing and fixing C.P. Brass Pillar Cock of approved quality confirming to IS: 8931 |
| 83 | 15mm nominal bore |
| 84 | Providing and fixing 35mm thick panelled glazedor panelled shutters for doors,including stainless steel butt hinges with necessary screws with superrior hardwood Cat-II [A] including panelling with 25mm thick panels all complete |
| 85 | Standard hard wood cat-II\"A\" |
| 86 | Supply and fixing of Bitumastic tarfelt waterproofing shed as per direction of Engineer in charge |
| 87 | Providing and fixing soil and waste vent pipe with uPVC pipeconforming toIS 13592 type B including jointing with solvent cement etc complete as per direction of Engineer-in-charge |
| 88 | 110 mm dia. nominal bore |
| 89 | 75 mm dia. nominal bore |
| 90 | Providing and fixing in position eaves or facia board with 19mm thick Marine Plywood (Green ply or equivalent) conforming to IS-710-1981 and 30cmwide including nailing etc complete as per the direction of Engineer-in-charge. |