| 1 | SCHEDULE ‘A’ PART-I(BUILDINGS & STRUCTURES)Details of prepriced schedule is given in tender documents. |
| 2 | SCHEDULE \"A\" PART-II ( EXCAVATION, EARTHWORK, SITE CLEARANCE& SITE DEVELOPMENT) Details of prepriced Schedule is given in tender documents. |
| 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 5 | SCHEDULE \"A\" PART-V (ROAD/ PATH/ HARDSTANDING)Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents. |
| 8 | SCHEDULE \"A\" PART-VIII (SECURITY WALL, FANCING AND GATE) Details of prepriced Schedule is given in tender documents. |
| 9 | SCHEDULE \"A\" PART-IX (EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \"A\" PART-X (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \"A\" PART -XI (MISCELLANIOUS ITEMS)Note:- This scheduleis not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" E \" signifies this fact only. |
| 12 | INTERNAL WATERSUPPLY: S&F for 15mm dia bore CP bib cock with CP wall flange (Make : jaquar model no. OPP-CHR-15037PM / Eqvlt in kohler) , cast copper alloy , screwed down high pressure with crutch or butterfly handle screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-Charge |
| 13 | S&F for 15mm dia bore CP two way bib cock with CP wall flange (Make : jaquar model no. OPP-CHR-15041PM / Eqvlt in kohler) , cast copper alloy , screwed down high pressure with crutch or butterfly handle screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-Charge |
| 14 | INTERNAL ELECTRICSUPPLY:S & F LED light fitting10 Watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 15 | S&F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make:Luker or Equivalent |
| 16 | S&F LED Bulp 10 Watts with Pendant ordinary, comprising ceiling rose, brass with insulated body lamp holder, cord grip pattern, and 0.5 sq.mm copper flexible twisted twin cord up to 1.5m length as ordered complete all as specified and directed |
| 17 | S & FVertical triple pole & neutral (VTPN), double door, 6-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. |
| 18 | S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete all as specified and as directed for ACs. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) |
| 19 | Supply and fix Engage light with Green & Red LED complete all as specified and as directed |
| 20 | M&L for TV socket TV socketmodulemetal flushed including flushed Box cover plate Box for 2 way module complete all as specified. |
| 21 | M&L for telephone jack with modulemetal flushed including flushed Box cover plate Box for 2 way module complete all as specified. |
| 22 | Supply, Laying, Terminating, Testing & Commissioning of 2 core 24/0.2 mm ATC twin twisted, FRLS type armored Cable with all mounting accessories etc complete all as specified and as directed |
| 23 | SWAGE DISPOSAL:S&F 150mm bore dia DWC(double wall corrugated) HDPE pipe, laid including all levelling complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F 150mm DWC full coupler complete all a specified and directed by Engineer-in Charge |
| 25 | M&L for 50 user RCC Septic tank of size 4.00M x 1.40Mdesigned to carry sewage and sullage water, excavation in any type of soil, PCC 1:2:4 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter as per TD - 016 Sheet no.1R/3 , 2R/3 and 3/3 . |
| 26 | Soakage wells excavation, in any type of soil, foundation in PCC 1:4:8, walls of honey combed masonry including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M30/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size size-1.8 M dia X 3.0 M effective depth complete all as specified and as directed |
| 27 | ARBORICULTURESupply and fixing the hedging of 300mm wide and 300mm height hedge plants along with necessary excavation for planting of hedging as including preparation of ground, with sweet and cow dung manure mix (3 parts sweet earth 1 part cow dung) @20 CuM/100 Sqm (minimum) and applying plant protection chemicals @60 gms/Sqm and maintaining and transporting of the hedging as per standard gardening practice complete all as specified and directed |
| 28 | Supply and planting Korean/Mexican carpet grass by piece turffing over the prepared base including watering, removing the weeds or any other vegetation, mixing the manure from time to time as required complete all as specified and directed Note Supply only loose soil.cow dung and vermi compost shall be measured and paid separately under respective item of this schedule Including period of 12 month maintenance of Carpet Grass removing of weeds, watering, sparying, adding manure etc all as specified & dsirected |
| 29 | Supply only approved sweet earth/loose soil best quality for plantation all as specified and directed |
| 30 | Supply only approved vermi compost of best quality all as specified and directed |
| 31 | Supply only approved manure (Cow dung) best quality all as specified and directed |
| 32 | Shrubs Digging of pits 60x60cm refiling with good soil and organic manure, supply and planting of healthy and grown plants with good root system of minium height three feet at the time of planting from the ground level maintance for aperiod of two months watering deweeding loosening of soil, manuring with manure neem cake, pruning and spraying of insecticides and when required. Bougainvillea plant 3 feet x 3 feet. |
| 33 | EXTERNAL WATER SUPPLYM&L for Cutting of 50 mm bore cast iron pipes in position for insertion of new tees, branches, etc.Note: Earth work & All type of CI fitting, Jointing etc will be measured & paid separately. |
| 34 | EXTERNAL ELECTRICSUPPLYM & L in for LT panel Board cubical KIOSK Outdoor type compact415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Copperbus bar of 150 Amp capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and out going with comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of shor circuit withstand Test report issued by CPRI in respect of LT Panel(b)Contractor shall submit the drawing for approval prior to place the order.Make of Panel : Hensel/C&S/L&TMake of MCCB/MCB : Legrand/L&T/Schneider/Hager(a) Incoming - MCCB100 Amp FP 25 KA - 01 No (b) Outgoing - MCCB 63 Amp TP 16 KA-01 Nos (c ) MCCB 40 Amp TP 16 KA-02 No(d) MCB 32 Amp TPN, 10 KA \"C\" curve- 02 Nos( e) Street light timer 20A capacity with contactor ML-2(f) Digital panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm |
| 35 | Supply and fix Octagonal hot dip galvanised iron pole, 7m long with base plate, 300 mm long weather proof reinforced door opening with MCB and RYBN terminal arrangement, \"J\"shape, EN8 foundation bolt with nuts template including RCC foundation as per manuacturer\"s design conforming to IS 1786 and hot dip galvanised single arm bracket for fixing of street light with one MCB 6 Amp with 40 Amp RYBN terminal block all as specified and directed. The foundation shall extend above surrounding levels by 200mmall as directed by Engineer-in-charge. Make :Surya/ Bajaj /UtkarshNOTE :(i) The contractor should submit manufacturer\"s foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate.(ii) Applying one coat of Aluminium paint including numbering of pole in the quoted rate. |
| 36 | S&F in one run of PVC insulated 1.5 sqmm copper three core conductor cable between cable loops box to fitting drawn through the pole complete all as specified and as directed. |
| 37 | RO PLANT S&F Domestic type RO water purifier fully automatic operation with auto start and auto off secondary purification by UF after RO ensuring enhanced water quality throughout service cycles and with TDS control system enabling maintaining of essential natural minerals in purified water, spin welded RO membrane housing to prevent tampering built in SMPS to operate with 160-250 V leak proof ABS construction for corrosion free life span suitable for all type of RAW water like borewell, shallow well, overhead storage tanks, water tankers all as specified and directed with following specification:-(i) Prefilter with connected accessories-01 No(ii) Purification capacity -15 ltrs/hour(iii) Max duty cycle -75 ltrs/day(iv) Storage tank capacity - 8 ltrs(v) RO membrane - 1812-75 GPD(vi) UF membrane - 0.01 micron(vii) Min inlet water pressure - 0.3 kg/cm2(viii) Input voltage - 160-250 V DC(ix) Operation voltage -24 V DC(x) Dimension : L-340mm W-265mm H-505mm(xi) Net Weight - 6.5 KgMake:- Kent RO (Elegant Lite) |
| 38 | REFRIGERATION AND AIR CONDITIONINGSupply and installed voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stablized at 230V with accuracy of (+,-) 2.5 % and capacity 1 KVA . |