| 1 | NOTE: Schedule ‘A’ Part I to XIII under Ser No. 1.00to 13.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. |
| 2 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch \"A\" Part I. |
| 3 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch \"A\" Part II |
| 4 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch \"A\" Part III |
| 5 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch \"A\" Part IV |
| 6 | Lump sum price worked out for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Sch \"A\" Part V |
| 7 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch \"A\" Part VI |
| 8 | Lump sum price worked out for AREA DRAINAGE as listed in Sch \"A\" Part VII |
| 9 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch \"A\" Part VIII |
| 10 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch \"A\" Part IX |
| 11 | Lump sum price worked out for RETAINING WALL as listed in Sch \"A\" Part X |
| 12 | Lump sum price worked out for DEMOLITION AND DISMANTLING as listed in Sch \"A\" Part XI |
| 13 | Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch \"A\" Part XII |
| 14 | Lump sum price worked out for AIR CONDITIONING AND REFRIGERATION as listed in Sch \"A\" Part XIII |
| 15 | SCHEDULE \"A\" PART - XIV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 16 | INTERNAL ELECTRIFICATION |
| 17 | Supply and fix wall mounted LED box type tube light fitting 4\" x 20Watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregrated electronic driver connector block etc. with warranty option of 5 years from date of installation complete with all accossories internally prewired and necessary mounting arrangments and provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 18 | Supply and fix LED tube light fitting mirror type with aluminium housing, high output diffuser 2 feet, 10 watt 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting with warranty option of 5 years from date of installation complete all as specified and directed. |
| 19 | Supply and fix highly efficient LED bulbs, 10 Watt, used as ready replacement for existing GLS/ CFL direct fit lamp in B22 cap complete all as specified and directed. |
| 20 | Supply and Installation of Smart Single Phase Meter of different makes (not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence and LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port provision on meter box. (b) Meter should support the following data: 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data and antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.(c) Meter should have connect/ disconnect functionality operable from prepaid billing software and shall show balance on display.(d) The meter should support open communication protocol DLMS with the software.Notes:- (i) It should run the meter in both prepaid and postpaid mode(ii) The meters should carry 5 year warranty.(iii) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(iv) The meter cost should include DCU/ Gateway and repeater cost for RF communication meters |
| 21 | Supply and Installation of Smart Three Phase Meter of different makes (not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 3 x 240 V, 50 Hz, 10A-100A, with 1600 impulses per KWh & KVArh, LED for relay status, conforming to IS-16444 standard with inbuilt cellular or inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port provision on meter box. (b) Meter should support the following data: 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data and antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.(c) Meter should have connect/ disconnect functionality operable from prepaid billing software and shall show balance on display.(d) The meter should support open communication protocol DLMS with the software.Notes:- (i) It should run the meter in both prepaid and postpaid mode(ii) The meters should carry 5 year warranty.(iii) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(iv) The meter cost should include DCU/ Gateway and repeater cost for RF communication meters |
| 22 | Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software with following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy, Power, Current, Voltage, Power factor and Frequency.(b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system should support meter data repository. The system should support meter replacement process.(iv) Excel Export: The system should support export of metering and billing data in excel formatNotes:- (i) Software shall be compatible with all makes of smart meter and shall be CERT-IN certified from CERT approved vendors for any cyber security related threat and complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc. and shall be included in quoted rate for 2 years defect liability period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software should be hosted on MEITY GCC approved server. 2 years hosting costs should be included. |
| 23 | Material and labour for maintenance free chemical earthing technology with copper bonded steel rod 3 metre long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified one. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.Notes:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii) Test Results of earthing to be submitted by the contractor for all earthings.(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall deposit 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv) Failing to maintain resistance of earthing less than 1.0 ohm, new earthing is to be provided by the contractor without any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surrounding area complete. |
| 24 | SEWAGE DISPOSAL |
| 25 | Supply, laying and testing of double wall corrugated (DWC) high density polythylene pipes (HDPE) of 150mm dia and stiffness class-8 (SN-8) as specified in IS 16098-2013 part-2, ISI marked with and including all fittings and jointing material including elastomeric sealing \"O\" rings as per manufacturer\"s instructions complete to make the sewer line functionalcomplete all as specified and directed.Note: (i) Construction method shall be strictly complied as per clause no A-4 of Annex lA of IS 16098 Part II.(ii) The quoted rate shall be deemed to include for laying of pipes level or to falls in trenches etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.(iii) The quoted rate shall be deemed to include for all necessary extra joints, waste and cutting etc. |
| 26 | EXTERNAL ELECTRIFICATION |
| 27 | Supply and laying double wall corrugated (DWC) high density polythylene pipes (HDPE) of nominal outer dia 90 mm and nominal inner dia 76 mm, having corrugation on the outer wall and plain surface on the inner wall confirming to IS:14930 (Part I and II) for protection of underground cables with all fittings laid in trenches/ under roads/ nallah or fixed along walls for cable protection,complete all as specified and directed. |
| 28 | Supply and laying double wall corrugated (DWC) high density polythylene pipes (HDPE) of nominal outer dia 63 mm and nominal inner dia 50 mm, having corrugation on the outer wall and plain surface on the inner wall confirming to IS:14930 (Part I and II) for protection of underground cables with all fittings laid in trenches/ under roads/ nallah or fixed along walls for cable protection,complete all as specified and directed. |
| 29 | Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof IP 65 protection, made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:-Note: All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves. |
| 30 | INCOMING:- (a) Copper strip busbar of 320 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bolts and washers for cable connections including hydrographic insulators with nuts and bolts at both ends - 04 Nos.(b) 4 Pole MCCB ,160 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No.(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC - 01 set (set of three)(d) Digital ammeter of range 0-250 Amps, flush mounting type with CTs of ratio 250/5 and selector switch - 01 set.(e) Digital voltmeter of range 0-500 Volts, flush mounting type with selector switch - 01 No.OUTGOING:- (a) 4 Pole MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 18 KA breaking capacity including all fixing accessories with both ends spreader links - 02 Nos.(b) MCB, Triple Pole and Neutral, 63 Amps, 415 Volts, \"C\" curve, 10 KA - 01 No. |
| 31 | DEMOLITION AND DISMANTLING |
| 32 | Taking down carefully copper/ aluminium submain wiring of any size from surface/ concealed or existing conduit of any height and removing materials to MES store for taking credit complete all as specified and directed. |
| 33 | Taking down old/ unservicable distribution board by disconnection of electric connection carefully, SPN DBs/ TPN DBs/ Main Switch including old servcable MCCBs/ MCBs, isolators etc. and carrying to MES store for taking credit complete all as specified and directed. |
| 34 | Dismantling and taking down electric energy meter of any type and size and carrying to MES store complete all as specified and directed. |
| 35 | Taking out/down unservicable LT UG cable of size 2 core x 10 sqmm from trenches/ pipes/ ducts/ polecomplete all as specified and directed. |
| 36 | Taking out/down unservicable LT UG cable of size 3.5 core x 50 sqmm from trenches/ pipes/ ducts/ polecomplete all as specified and directed. |
| 37 | FIRE FIGHTING SYSTEM |
| 38 | Supply and fix 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend and horn, wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directed. |
| 39 | Supply and fix 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683:2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. |
| 40 | Supply and fix 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directed. (In parking area) |
| 41 | Supply and fix 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683:2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. (1 No. at entry/ exit) |
| 42 | Supply and fix galvanised mild steel fire bucket (filled with dry sand) conforming to IS 2546: 1974 round bottom type enamel painted, white inside and red outside and letters \"FIRE\" in black outside and handle with mounting bracket complete as specified and directed. |
| 43 | Supply and fix signage made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board with mirror fasteners complete of size 300 mm X 150 mm reading \"EXIT\" in 12.5 mm block letters in green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and directed. |
| 44 | Supply and fix signage made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board with mirror fasteners complete of size 450 mm X 150 mm reading \"FIRE EXTINGUISHER\" in 12.5 mm block letters in white and red background, properly spaced to provide good legibility located directly in corridor near to each Manual call point/ Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and directed. |
| 45 | Supply and fix CL#150 rated three-piece design 25 mm NB cast steel (CS) straight pattern ball valve, conforming to IS 9890: 1981 and tested as per BS 6755-1, having cast iron body, stainless steel AISI 304 ball, renewable PTFE seat and gland packing, CS fastners and lever having screwed/ socket weld end connection with accessories complete all as specified and directed. |
| 46 | Supply, installation, testing and comminsioning of fully automatic Star/ Delta starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/ manual selector switch, overload protection, current sensing type single phase preventer complete with all accesories and wiring etc. complete all as specified and directed. |
| 47 | Material and labour for 1100 Volts grade 3 core, 6 mm² copper conductor, XLPE armoured cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per CI. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/ wire and PVC Type ST-2 outer sheath conforming to IS 5831-1984, icluding necessary clamping/ dressing with cable ties and termination complete all as specified and directed. |
| 48 | Supply and fix PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly and cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 ˚C installed on all high points in the water piping system to automatically remove the trapped air with necessary accesories complete all as specified and directed. |
| 49 | Supply and fix orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. |
| 50 | AIR CONDITIONING AND REFRIGERATION |
| 51 | Supply and fix ductable central air cooling unit, of air flow capacity 34000 CMH/ 20000 CFM, 3 phase single speed - AMCA certified DIDW forward curve centrifugal fan with motor, IE3/ IE2, 4 Pole, IP 55, high efficiency honey comb cooling pads, three/ four side, box type HDPE non-woven mesh filter, efficiency 90% down to 10 micron, auto control float valve for continuous water supply, water recirculation pump 50 Watt, cabinet with powder coated GP sheet with extruded aluminium profile framing, cooling pads with large capacity water tank and with following specifications complete all as specified and directed.(i) Discharge type - side(ii) Air flow - 34000 CMH, 20000 CFM(iii) Static pressure - 40 mmwg(iv) Motor power - 9.30 KW(v) Main power - 415 Volts, frequency - 50 Hz(vi) Fan type/ fan speed - Centrifugal blower, 3 Phase, single speed(vii) Noice level - less than 70 dBA(viii) Water tank capacity - 700 Litres(ix) Controller type - Manual Knob Controller(x) Evaporation efficiency - 80% |
| 52 | Supply and fix electric controller with 2 meter 4 core copper wire with 415 Volts, 50 Hz, starter equipped with MCCB/ MPCB, contactor, start and stop push button, protection with electronic overload relay, single phase preventer and short circuit protection complete all as specified and directed. |
| 53 | Supply and fix aluminium powder coated air grills without damper complete all as specified and directed. |
| 54 | Supply and fix flexible canvas connection complete all as specified and directed. |
| 55 | NOTE: Amount of credit of Rs. 5,24,547.70 for retrieved materials is mentioned in schedule of credit of tender documents in pdf form which will be deducted offline while acceptance of tender. |