| Sl. No. | Item Description |
| 1 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 2 | Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 3 | Excavating over areas exceeding 1.5 m but not exceeding 3 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 4 | Excavating over areas exceeding 3 m but not exceeding 4.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 5 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed. |
| 6 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 8 | M&L brick work sub class B, class designation 75 old size bricks, laid flat in floors, walls or of similar types,bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3. including dismantling of existing surface complete all as specified and directed. |
| 9 | M&L except bricks for brick work with sub class \"B\" bricks, laid flat in floors, old size, laid dry and pointed in cement mortar (1:3) complete all as specified and as directed. |
| 10 | M&L for brick work with sub class \"B\" bricks, laid on edges in floors, old size, bedded and jointed in cement mortar 1:6 and pointed in cement mortar (1:3) including dismantling of existing surface complete all as specified and directed. |
| 11 | M&L except bricks for brick work with sub class \"B\" bricks, laid flat, in floors, modular size, bedded and jointed in cement mortar 1:6 and pointed in cement mortar (1:6) complete all as specified and as directed. |
| 12 | M&L for PCC 1:3:6 type C1 (using 20mm nominal size crushed and graded stone aggregate) as in surface channels & drainsincluding dismantling of existing surface complete all as specified and directed. |
| 13 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 14 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 including dismantling of existing surface complete all as specified and directed. |
| 15 | M&L 15 mm thick plastering on brick/ stone/ concrete surfaces of wall in cement mortar (1:4), finished even & smooth without using extra cement, including taking down existing surface complete all as specified and directed. |
| 16 | M&L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including dismantling of existing surface complete all as specified and directed. |
| 17 | M&L for providing reinforced cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100 sqcm but not exceeding 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed including dismantling of existing surface complete all as specified and directed. |
| 18 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 19 | M&L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 20 | S&F in repair for rolled MS in joist, angle, channel sections fixed independently without connecting plates etc of grade Fe 410W (Gde E-250) quality B complete all as specified and directed. |
| 21 | M&L in repair for Mild steel round bars 10mm dia & over,cut to length, bent to shape required, for strengthening of chain link fencing including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to GD-I. IS-432 (Part I) complete all as specified and directed. |
| 22 | S&F in repair galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type if standard rail s straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staple or steel pins etc. complete in all respect as specified and directed. |
| 23 | S&F in repair for chain link fencing MS galvanized 3.14 mm dia of wire and 50mm square size including line wire, rails, straining bolts etc including, binding wire and taking down old fencing wire complete all as directed by Engr-in-charge complete all as specified and as directed |
| 24 | S&F in repair for mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed. |
| 25 | M&L in repair for mild steel works in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittingsand hanging; also fastening and fixing (Fe 290 (Gde E-165) ) complete in all respect as specified and directed. |
| 26 | S&F in repair for framed work such as grills, gratings,etc with ends of bars shouldered and /or riveted, or forged into spikes framed guard bars barred iron doors , laddersand similar work conforming to Fe 410-0 or FE310-0 complete all as specified and directed. |
| 27 | M&L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks including dismantling of existing surface complete all as specified and directed. |
| 28 | M&L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and smooth without using extra cement including dismantling of existing surface complete all as specified and directed. |
| 29 | M&L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. including dismantling of existing surface complete all as specified and directed. |
| 30 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 31 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. including dismantling of existing surface complete all as specified and directed. |
| 32 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 33 | Preparation of old or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M&L for precast RCC (1:2:4) type B1 (using 20 mm graded stone aggregates) for cover slab of manhole/ soak pit etc set in cement mortar 1:6 including formwork complete all as specified and as directed. |
| 35 | Supplying and laying reinforced concrete pipes with collars, 450 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) including dismantling of existing surface complete all as specified and directed. |
| 36 | M&L for plain cement concrete chequered tiles, general purpose, double layer of size 30 cm X 30 cm X 20-25 mm thick with grey cement and no pigments in wearing layer as per IS 1237: 2012, set, jointed and pointed in neat cement slurry in floor including laying over 15 mm thick bedding of cement mortar(1:4) all as specified and as directed. |
| 37 | Preparaing old decorated plastered or unplastered surface of wall and apply two coats of white wash including scrapping down of old white washcompletely complete in all respect as specified and directed. |
| 38 | Preparation of newly plastered surfaces on walls and applying two coats of white wash complete all as specified and as directed. |
| 39 | M&L for preparation of new plastered or undecorated surfaces of wall/ceiling using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 40 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 41 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 42 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 43 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 44 | M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 45 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 46 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed |
| 47 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 48 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor including taking down existing sheet complete all as specified and directed. |
| 49 | S&F coloured 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet having tensile strenght of 550 Mpa as in ridge, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, including taking down existing sheet complete all as specified and directed. |
| 50 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor including taking down existing sheet complete all as specified and directed. |
| 51 | Supply and Fix exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping , of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with 4mm dia GI wire as suspender and including 4mm thick decorative pre -painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/wooden truss of any type complete all as specified and directed. |
| 52 | S&F in repair for mild steel sections (Beam, tee, angle, channel or flat sections) in rooftrusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing, independent fixing with welding etc.including distance pieces, cleats etc. using Fe 410-W (Gde E-250) quality Acomplete in all respect as specifified and directed. |
| 53 | M&L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 13 sqcm but not exceeding 25 sqcm including taking down complete all as specified and as directed. |
| 54 | M&L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including formwork including dismantling of existing surface complete all as specified and directed. |
| 55 | S&F 2nd class Hard wood scanttlings, wrought in any position for framed work jointing wirh nails, screws, nut bolt etc. including necessary supports to existing truss including Dismantling of timber scanttlings 40 Sqcm & over in section, in any position for framed workcomplete all as specified and directed. |
| 56 | M&L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 57 | M&L for preparation of old decorated wooden surfaceswith pre mixed wood filler used as putty of grith exc 10cmand applying two coats of synthetic enamel paint complete all as specified and directed. |
| 58 | M&L for preparation of old undecorated steel surfaces with pre mixed steel filler used as putty and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 59 | M&L for preparation of old decorated surfaces of wall after complete scrapping down and using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 60 | M&Lfor preparation ofnew surface of plastered wall using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller overincluding one coat of alkali resistant priming paint before distempering complete all as specified and directed. |
| 61 | M&L for preparation of old decorated surfaces including washing, rubbing down and stopping of white wash surfaces of walls (Plastered or un-plastered) including cormices pilasters etc and using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller including one coat of alkali resistant priming paint before distempering complete all as specified and directed. |
| 62 | S&F 18-19mm block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work including necessary leaping/edge margin of 3mm thick with decorative face veneer on both faces complete in all respect as specified and directed. |
| 63 | S&F powder coated aluminium window and ventilator shutters, side hung type with/without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, EPDM rubber packing (of 50 No) grade), powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 64 | M&L for anodised aluminium frame poder coating ( Minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 65 | S&F Anodised aluminium ventilator with half portion louvered (adjustable)with 4mm thick glass in louver and balanced portion fixed 4mm thick frosted glass glazing including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete in all respect as specified and directed. |
| 66 | M&L for anodised aluminium grill for doors, windows, ventilators including joining cleat for fixing etc. complete in all respect as specified and directed. |
| 67 | S&F 30mm thick second class HW glazed andskeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars),edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc,sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a) complete allas specified and directed. |
| 68 | Supplied and fixed 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete in all respect as specified and directed. |
| 69 | S&F in repair for stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 70 | S&F in repair for butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 125B21 as per IS 205: 1992 complete all as specified and as directed. |
| 71 | S&F in repair for aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 72 | S&F in repair for cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 73 | S&F in repair for aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 74 | M&L for rendering15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfacesusing water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement including taking down existing surface complete all as specified and directed. |
| 75 | M&L 15 mm thick plastering on brick/ stone/ concrete surfaces of of wall in cement mortar (1:6), finished even and smooth without using extra cement, including taking down existing surface complete all as specified and directed. |
| 76 | Supply & fix in repair for sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 77 | Material and labour for brick work with sub-class \"B\" old size bricks of class designation 75, straight or curved on plan exceeding 6m mean radiusbuilt in cement mortar (1:6) including dismantling of existing brick work built in cement mortar complete in all respect as specified and directed. |
| 78 | M&L for half brick work with subclass ‘B’ old size bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:4) including dismantalling of brick work built in cement mortar in any position, complete in all respect as specified and directed. |
| 79 | S&F in repair for mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed. |
| 80 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.36 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, including dismantling of existing surface complete all as specified and directed. |
| 81 | Providing and laying coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.08 sqm but not exceeding 0.15 sqm, in skrting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick rendering in cement mortar (CM) 1:4, including dismantling of existing surface complete all as specified and directed. |
| 82 | S&F in repair for 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 83 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 84 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 85 | S&F in repair for 4 mm thick of size 600 mm x 450 mm bevelled edge mirror of selected quality decorative type mounted on 6 mm commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete in all respect as specified and directed. |
| 86 | S&F in repair for rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 87 | S&F in repair for PTMT ball valve high pressure 20mm bore with epoxy coated aluminium rod & high density plastic ball screwedfor iron/CPVC pipe/fittings complete all as specified and directed. |
| 88 | S&F in repair 15mm bore concealed long neck , CP finished stop valves, cast copper alloy, screwed down, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete in all respect as specified and directed. |
| 89 | Taking down existing damaged EWC alongwith complete PCC and cement concrete from sunken floor and providing new EWC and seat cover and water proofing treatment to sunken floor as per following stages:-(a) 15 mm thick plastering in CM (1:3) with WPC at all around wall and base of sunken floor with proper slope.(b) Applying a coat of 85/25 gde hot bitumen @ 1.2Kg/ Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 50 micron, natural colour with cold cut back adhessive. (c) Fixing of 25mm dia GI pipe (mediumgrade) spout of length 45 cm. (d) Supply & fixing of vitreous china wash down water closet pan (pedestal pattern), white, seat cover and P or S type bend etc complete includingproviding cement concrete and cement filling (1:5:10) and 25 mm thick PCC 1:2:4 at top surface.. |
| 90 | S&F in repair PVC valveless, syphonic action type, low level dual flush cistern 10 ltr capacity, white, wtih inlet, ball valve, float and handle including bracketS&Flush pipe of polyethylene for low or high level cistern of required height of high density PVC, 32 mm dia pipe, complete in all respect as specified and directed. |
| 91 | S&F in repair for 15mm size PVC connection pipe with PTMT nut of length 450mm complete all as specified and directed. |
| 92 | S&F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 93 | S&F in repairs long body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete in all respect as specified and directed. |
| 94 | Supply and fixed in repair 15mm bore, cast ABS body, CP finish, shower rose of size 125 mm dia and shower arm of cast copper alloy CP finished, fixed to iron pipe/fiitingscomplete in all respect as specified and directed. |
| 95 | S&F in repair for brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 96 | S&F in repair Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with brass chromium plated bracket guard and railing 60 cm long complete in all respect as specified and directed. |
| 97 | S&F in repair wash hand basins (WHB), vitreous china of size 550x400 mm (flat back or angle back type), including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32 mm dia bore waste fittings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15 mm bore dia fancy type CP finish Pillar tap, cast copper alloy with capstand heads, screw down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screw for iron pipes complete in all respect as specified and directed. |
| 98 | S&F in repair Health faucet ABS SS braided hose 1 mtr with V hook including fixing arrangement, complete in all respect as specified and directed. Make:- Hindware, Cat Part No. F160068IV), or equivalent make of Cera, Perryware. |
| 99 | S&F in repair for 75 mm dia of outlet, PVC (SWR) nahani trap, plain with SS grating of size 150mmX150mm, 0.75mm thick openable at center including jointing with solvent cement, complete in all respect as specified and directed. |
| 100 | S&F in repair for PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed. |
| 101 | S&F in repair for PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed. |
| 102 | S&F in repair for PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed. |
| 103 | S&F in repair for PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed. |
| 104 | S&Fin repair for PVC (SWR) Tee(87.5⁰) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. |
| 105 | S&Fin repair for PVC (SWR) Tee(87.5⁰) single, 75 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. |
| 106 | S&F in repair for PVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 107 | S&F in repair for PVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 108 | S&F in repair for PVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed. |
| 109 | S&F in repair for PVC (SWR) vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 110 | Supply and fixed unplasticised in repair for PVC (SWR) Gully trap125/110 mm, setting and jointing with solvent cement complete in all respect as specified and directed. |
| 111 | M&L for precast RCC, type B-1, 1:2:4 (using 20 mm crushed and graded stone aggregate) as in manhole covers/ cover slabs or of similar type slab works, etc. incl necessary formwork and loading/ unloading of the same and fixed in position, complete in all respcet as specified and directed. |
| 112 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 113 | Material and labour in replacement of point wiring with 1.5 Sqmm PVC insulated FRLSH unsheathed multi stranded copper conductor cable 1100 Volts grade single core conforming to IS-694-1990 and one run of continous earth wire with 1.50 Sqmm stranded core PVC insulated unsheathed copper conductor cable draw in & including PVC conduit not less than 20mm dia rawal plugs & screws including necessary fittingS&Fixtures and including PVC modular terminal box and modular PVC cover plate making good disturbed surface with CM (1:4) to match with the existing surface for the following:- One light/fan/exhaust fan point controlled by one, one way switch, with cable 1.5 sqmm |
| 114 | All as per item 113 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed. |
| 115 | All as per item 113 here-in-before for 3 pin 15 amps switch socket combination on indpendent board with 4.0 sqmm capper cable complete all as specified and as directed. |
| 116 | All as per item 113 above but for 3 pin 5 Amps switch socket on same board with 1.5 sq mm copper cable complete all as specified and directed. |
| 117 | S&F in replacement of modular switch, 1 way, 6/10 Amp SP, 1 module complete all as specified and as directed. |
| 118 | S&F in replacement of Modular fan step regulator, 120 W, 2 modules complete all as specified and as directed. |
| 119 | S&F in replacement of for ceiling rose surface bakelite3 phases polycarbonate isolated body complete in all respect as specified and directed. |
| 120 | S&F in replacement of (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 121 | S&F in replacement of Modular Socket 6 A /16 A-2/3 pincombined 2 module complete all as specified and directed. |
| 122 | S&F in replacement of modular switch, 1 way, 16 Amp SP, 1 module complete all as specified and as directed. |
| 123 | S&F in replacement LED batten luminaires, 20 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of size 23/0.0076, from connector and ceiling rose, complete all as specified and directed. Make Havells/Bajaj/CG |
| 124 | Supply & fix recess/suface mounting 2\" x 2\",LED flat light 34/36W, luminaire with comfortable glare free soft illumination 5700K including taking out old U/s complete all as specified and as directed. |
| 125 | Supply & Fixin replacement LEDwall security lightsof 35 W with necessary brackets (made out of 25mm bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc to be fixed on walls including taking out old u/s complete all as specified and directed. |
| 126 | S&Fin replacement of MCB single pole (SP) 6 to 32 Amps,240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed. |
| 127 | M&L in replacement of MCB SPN 32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed. |
| 128 | M&L in replacement of sheet metal enclosure MCB DBs SPN , 12 way 240 V, with 100 A rated bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. |
| 129 | S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed. |
| 130 | Supply and fix in replacement of sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Cost of cutting chase and making good shall be included in the quoted rate. |
| 131 | M&L in replacement of submain wiring with two run of6 sq mm FRLSH PVC insulated stranded copper conductor cable 1100 volts grade drawn through and includingPVC casing and capping(ISI marked and medium mechanical strength) of suitable size with all fittings and accessories with one run of 6 sq mm FRLSH PVC insulated solid copper cable for earth continuity and connected to common earth dolly including taking out old u/scomplete all as specified and directed.Note:- cost of PVC casing capping, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:3) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 132 | M&L in replacement of for sheet metal enclosure for TPN DB-VTPN 4 way 415 V, double door, 100 A copper bus bar, IP 43, including 160 Amp MCCB 4 pole microprocessor released based as incomer as flush mounted complete all as specified and as directed. |
| 133 | M&L for reparing/rewinding of u/s ceiling fan/exhaust of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible chord of copper of suitable size, testing commissioning after completion of the work.[Note:- (1) Rewinding of fans included in this quoted rate.(2) U/s fan(ceiling or exhaust) will be issued by department /user]. |
| 134 | M&L for earthing complete with galvanised perforated steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge of the pipe not less than 1.25 metres below ground level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanisediron or steel all as shown in electrical plate No 2 of SSR Part Iconnected to earth test point all as specified or indicated and connected earth work, in soft/loose soil, removing soil upto 50m, refilling agricultural soil if sandy soil, PCC1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI light grade earth lead protection pipe,50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 20mm dia bars,funnel, strainer, alternate layer of charcoal dust and common salt at 2.5Mtr depth and testing on completion , complete all as specified and directed. |
| 135 | Supply, laying, jointing, testing and commissioning in replacement of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items). |
| 136 | Supplying & fixing to walls and ceilings or laid in floors 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 137 | Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed |
| 138 | M&L laying well burnt old size bricks, sub calss \"B\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail