Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 5 | M & L moorum filling in floors or paving laid in layers n.exc. 15 cm thick spread leveled and rammed including watering complete all as specified and directed |
| 6 | M & L hard core of gauge etc. 63 mm but n. exc. 100 mm deposited spread and leveled in layers n. exc. 15cmthick water and rammed etc. Complete all as specified and directed. |
| 7 | M/L for providing 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as directed. |
| 8 | M&L for coloured glazed ceramic tiles300x450mm, 7-8 mm thickas approved by GE as in dado / skirting or on vertical surfaces,over and including 10 mm thick backing coat in CM (1:3) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed. |
| 9 | Material and labour for non skid ceramic coloured tiles 7-8mm thick matching to dado tiles area of each tile 300x300mm, as in floor etc laid over and including screed bed 15mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match complete all as specified and as directed. |
| 10 | Material and labour for non skid ceramic coloured tiles 7-8mm thick matching to dado tiles area of each tile 400x400mm, as in floor etc laid over and including screed bed 15mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match complete all as specified and as directed. |
| 11 | M&L for non skid ceramic coloured tiles8-10 mm thickarea of each tile 600x600mm, as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6 ) set and jointed with white or coloured cement to match the shade of tile etc complete all as specified and as directed |
| 12 | All as per item No11 but as in skirting on vertical surfaces over and including 10 mm thick backing coat in CM (1:3) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed. |
| 13 | M&Lfor 20-25mm thick machine cut kota stone slab in flooring, stepsover 20 mm thick screed base in cement and sand (1:6) mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 14 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar including 15 mm thick backing coat in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge |
| 15 | M/L for 15mm thick Granite (of any type)machine cut, single piece jambs and double piece cills overall lenght of window riser of steps, skirting, dado and pillarlaid overcement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing,moulding complete and including rendering/ backing coat coat of 15 mm thick in CM 1:3 etc complete all as specified and as directed |
| 16 | M&L for 18 to 20 mm thick pre-polished granite stone slab of approved shade and color Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills, jambs etc or on vertical surfaces including vertical projection, full round molding the edge including 10 mm thick Screed /backing coat in CM (1:4) jointing& pointingin white cement (1:2 ) using marble dust with admixture of pigment to match the shade of granite rubbing & moulding complete all as specified and directed by Engineer-in-Charge |
| 17 | M&L for Machine cut cudappah stone slab 20-25mm thick over and including 15mm thick cement and sand screed in CM(1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 18 | M&L for 30-40mm thick rough dressed Shahabadstone as in floor/plinth etc over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 19 | Fixing/Laying only 30-40mm thick rough dressed Shahabadstone as in floor/plinth etc over and including 15mm thick screed bed in CM 1:6 including dismantling complete all as specified and directed |
| 20 | M&L for Reinforced cement concrete (design mix) in M-20 (20mm graded aggregate) for floor slab completely all as specified and as directed. |
| 21 | M&L for Mild steel TMT bars Fe 500D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 22 | Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified |
| 23 | M&L for Walling of random rubble,uncoursed well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified |
| 24 | M&L for brickwork with fly ash bricks straight or curved on plan exc6mmean radius,built in CM 1: 6 complete all as specified |
| 25 | M&L for brickwork with fly ash bricks straight or curved on plan exc6mmean radius,built in CM 1: 6 complete all as specified |
| 26 | Raking out cement mortar joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to coursesetc complete all as directed. |
| 27 | M&L for Flush Pointing to random rubble or polygonal rubble uncoursed or brought up to courses in CM1:4etc complete all as directed. |
| 28 | Taking down cement mortar plaster on brick or stone walls,raking out joints, hacking for key complete all as directed |
| 29 | M&L for Dubbing out average 10mm in CM (1:6) thick on irregular face of walls (when specifically ordered in writing) |
| 30 | M&L forrendering, 15 mm thick on Stone Masonry/concrete surfaces in cement mortar 1:6 surfaces finished even and fair complete all as specified. |
| 31 | M&L forrendering, 10 mm thick on brick / concrete surfaces in cement mortar 1:6finished even and faircomplete all as specified and directed. |
| 32 | M&L forrendering, 15mm thick in two layers (10 mm under layer + 5mm finishing layer) on external surfaces of walls, 5mm thick in CM (1:4) with WPC over a coat of 10mm thick in CM (1:4) on brick/ concrete surfaces finished even and fair at any heightincluding scaffolding etccomplete all as specified and directed. |
| 33 | M&L for rendering 20mm thick in two layers (10 mm under layer + 10mm finishing layer) on external surfaces of walls,10mm thick in CM (1:4) with WPC over a coat of 10mm thick in CM (1:4) on Stone masonary/ concrete surfaces finished even and fair at any heightincluding scaffholding etccomplete all as specified and directed. |
| 34 | M&L for rendering 5mm thick on concrete surface of ceiling in CM 1:3 finished even and faircomplete all as specified and directed. |
| 35 | M&L forExtra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc.40mm complete all as specified and as directed |
| 36 | M&L Preparation of new plaster surfaces of walls and applying two coat of oil bound distemper over a coat of primer with 1 mm thick wall care putty to make the surface in plumb line including stopping of nails holes,cracks etc, finished even and smooth, complete all as specified and directed. |
| 37 | Material & Labour for preparation of new wall surface and applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm at any height including scaffolding etc complete all specified and as directed. |
| 38 | M & L for preparation of newly plastered surface of ceiling and apply two coats of white wash with 1 mm thick wall care putty to make the surface in plumb line including stopping of nails holes, cracks etc, finished even and smooth, at any height including scaffholding etc complete all as directed. |
| 39 | Material & Labour for complete removal of existing treatment on old plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm.at any height including scaffolding etc complete all specified and as directed. |
| 40 | M&L for preparation of old plastered or unplastered surfaces of ceilingsurface of ceiling and apply two coats of white wash with 1 mm thick wall care putty to make the surface in plumb lineincluding stopping of nails holes, cracks etc, finished even and smooth,at any height including scaffholding etc complete all as directed. |
| 41 | M & L for complete removal of existing treatment old plastered surfaces of walls and applying two coat of oil bound distemper over a coat of primer.with 1mm thick wall care putty to make the surface in plumb line including stopping of nails holes, cracks etc, finished even and smooth, complete all as specified and directed. |
| 42 | S&F fix in repairs wash hand basin with pedestal vitreous China white, flat back or angle type of size 550 X 400 mm incl waste chain and plug and porcelain stopper, waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge |
| 43 | S&F in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistern etc complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply only 10 ltr capacity PVC valve less, symphonic action type, flushing cistern, low level, all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in repairs, chromium plated shower rose (size 125 mm) with shower armetc complete all as specified and directed by Engineer-in-Charge. |
| 46 | Taking up or down 15 mm bore steel tubing and connections |
| 47 | All as in item No 46 here in before but 20 mm bore tubing |
| 48 | All as in item No 46 here in before but 25 mm bore tubing |
| 49 | Supplying and laying 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete all as specified. |
| 50 | All as in item No 49 here in before butbut 20 mm bore tubing |
| 51 | All as in item No 49 here in before but 25 mm bore tubing |
| 52 | S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified. |
| 53 | S&F in repairs fancy type stop cock/ angle cock/ two way cock cast copper alloy, Chromium plated fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge |
| 54 | Supply and fixing in repairs tubular towel rail, brass chromium plated 20 mm dia `D\"type, 60 cm long between flanges including a pair of bracketsall as directed. |
| 55 | S&F in repairsbib tap 15 mm dia, fancy type CP cast copper alloy with crutch or butterfly handlescrewed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. |
| 56 | S&F in repairs fancy type twin (Two way) bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handlescrewed down for iron pipe or for brass ferrule etc., complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply only 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as directed. |
| 58 | Supply only PVC flexible 32 mm Waste pipe for WHB, Sink etc complete all as specified. |
| 59 | S&F in Repairs Sink coupling PTMT (half or full threated), with rubber washer etc complete all as specified. Minimum weight 32mm-45Gms/40mm-60Gms |
| 60 | S&F in repairPVC (SWR) 110mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/floor etc complete all as specifed and directed. |
| 61 | All as in item No 60 here in before but laid in trenches or in floor |
| 62 | S&F in repairPVC (SWR) 75mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/floor etc complete all as specifed and directed. |
| 63 | All as in item No 62 here in before but laid in trenches or in floor |
| 64 | S&F PVC (SWR) 110 mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 65 | S&F PVC (SWR) 75mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 66 | S&F PVC (SWR) junction single, (Single T) equal or un equal110mm bore complete all as specified and as directed |
| 67 | S&F PVC (SWR) junction single, (Single T) equal or un equal75mm bore complete all as specified and as directed |
| 68 | S&F PVC (SWR) junction single, (double Y) equal or un equal110mm bore complete all as specified and as directed |
| 69 | S&F PVC (SWR) vent cowl110mm bore complete all as specified and as directed |
| 70 | Material and labour for water proofing treatment to sunken floor slab, and peripheral walls,etc, and shall be carried out as specified below and as directed.(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar ( Dr fixit, Pidicrete URP, Thermax CC or eqvt).(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” Thermax CC or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner.(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. |
| 71 | (e) In the remaining area, in dry substrate condition brush apply “Dr Fixit Bath seal Plus” or eqvtfirst coat and further apply second coat when first is dry. Extend the coating upto150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” Thermax CC or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC spout pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2 (including conreting).(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, Thermax CC etc. |
| 72 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nippleand connected complete all as directed. |
| 73 | M&L for cleaning of service tank up to 1000 ltrs by removing all scales, dirt, silt, mud etc from tank and mouth of outgoing pipe including washing of tank internally with bleaching powder after removing scale, dirt, silt, mud etc from tank and removing algae from outside of tank from below bottom of tank anddisinfecting tank by spraying sodium hypo chloride solution in tank etc complete all as specifiedand directed by Engineer-in-Charge. Note:- The quoted rate shall include dismantling and refixing of water tank as etc complete all as specifiedand directed by Engineer-in-Charge |
| 74 | S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and high density plastic ball screwed to iron pipe, tank nippleand connected (Minimum weight 15mm-142Gms/20mm-210Gms) complete all as directed. |
| 75 | Cutting chases in brick/ block wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed |
| 76 | Taking down chowkhats or frames not exc.1.5 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directedby Engineer-in-Charge |
| 77 | Taking down chowkhats or frames exc. 1.5 sq. m and n exc 4.00 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directedby Engineer-in-Charge |
| 78 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each etc complete all as specified and directedby Engineer-in-Charge |
| 79 | Taking down shutters of any description n exc 1 Sqm each etc complete all as specified and directedby Engineer-in-Charge |
| 80 | S & F Pressed steel door frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate, etc, complete all as specified, |
| 81 | S & F pressed steel door frame of size 100 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified, |
| 82 | S&F 35 mm thick IInd C/L H/Wglazed & skeleton shutters open rebated and prepared to receive glass gauge, divided into square or rectangles with plain chamfered or rounded mitered & rebated slash bars including beads mitered for securing glass wire gauge etc all as specified |
| 83 | M&L for 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 84 | S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed |
| 85 | S&F Solid PVC Door frame size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed |
| 86 | S&F factory made solid PVC moulded Door shutter with particle board core, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back space, supplying and fixing in frame at site as per specification & drawing complete all as specified and as directed |
| 87 | M&L 18/19mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work complete all as specified and as directed |
| 88 | S&F powder coated aluminium anodised aluminium frame, shutters fordoor,windows, ventilators with one or more rebates including joining cleat for fixing etc, rubber/neoprene beading and locking arrangement etc complete all as specified and directed by Engr-in-Charge |
| 89 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 90 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed |
| 91 | S&F butt hinges medium weight cold rolled mils steel 100mm long complete all as specified and as directed. |
| 92 | Supply and fixed mild steel butt hinges of 50mm length, cold rolled, medium weight, complete all as specified. |
| 93 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed |
| 94 | S&F aluminium anodised handle of extruded section 150mm long complete all as specified and as directed. |
| 95 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long complete all as specified and as directed. |
| 96 | S&F 300 mm mild steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed. |
| 97 | S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 98 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 99 | S&F, 150mm long hasp & staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete allas specified and directed. |
| 100 | S&F continuous (Piano) hinges mild steel, bright finish or electrogalvanised, width of flap 30mm completed as specified and directed. |
| 101 | S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed |
| 102 | Hacking out old broken glass( any thickness size ,quality or description ) from wooden/Steel frames glazed with putty or fixed with beads complete all as specified and as directed. |
| 103 | M & L for 3 mm thick sheet frosted/pin headed glass ordinary quality and glazing withoilputty orwoodenbeads in squares n.exc 0.50 sqm in each pane complete all as specified and as directed. |
| 104 | M & L for 4 mm thick plain sheet/ frosted/pin headed glass ordinary quality and glazing withoilputty orwoodenbeads, rubber bedding in squares n.exc 0.50 sqm in each pane complete all as specified and as directed. |
| 105 | M & L for preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed. |
| 106 | M & L for preparation of old wooden surface and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 107 | M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 108 | M & L for preparation of old steel surface and applying one coat of synthetic enamel paint complete all as specified and as directed |
| 109 | S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plug, washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915x 420 mm bowl size 410 x 330x 160mm including waste coupling, waste pipe etc complete all as specified and directed by Engineer-in-Charge. |
| 110 | S&F in repairsstainless steel kitchen plate rack made out of 0.63 mm thick stainless steel sheet of size 36\"\"x 36\"\"x 10\"\" with complete accessories including screwsetc complete all as specified and directed by Engineer-in-Charge. |
| 111 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 112 | S&F curtain rod 20mm dia, having corrugated PVC extrusion on eletric resistance welded MS pipe with fancytype with 02 Nos Knobs and 02 Nos brackets per each door/ windowsetc complete all as specified and directed |
| 113 | Full moulding/half moulding of stone slabs one edge, two edge, as in steps cooking platforms jambs and cills and other similar situationscomplete all as specified & directed. |
| 114 | S&F pegs set of 6 Nos, powder coated aluminium body fixed with cadmium plated screws as directed. |
| 115 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent cement complete all as specified and as directed. |
| 116 | S&F Chromium plated steel soap dish complete all as specified and as directed |
| 117 | Dismantling of unframed work fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed |
| 118 | M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doorsladders framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 119 | Dismantling of framed timber scantling 40 Sq, Cm and over in section, in any position |
| 120 | M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners.including dismantling existing sheets etc complete all as directed |
| 121 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners.including dismantling existing sheets etc complete all as directed |
| 122 | S&F of Mild Steel work of Grade ST 240 in Square/Rectangular tubes conforming to IS 4923 2017 or Circular section conforming to IS 1161-2014 as in Post, Trusses, Purlin, Rafter, Bracing etc including welding and providing special shaped washer etc.complete all as specified and as directed by Engineer in Charge |
| 123 | S&F of steel work in post, Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. as perFe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed by Engineer in Charge |
| 124 | S&F,structural rolled mild steel Fe 410-00 (Gde E-250) Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed by Engineer in Charge |
| 125 | M&L for Providing Water proofing treatment to RCC roof slab and shall be carried out as specified below and directed including testing of water tighness after completion of water treatment works to entire satisfaction of GE :-(a)The plastered roof surface shall be thoroughly cleaned with wire brushed, cleaned to eliminate all sharp projection, washed, dried up and cleaned of all foreign matter and dust to receive primer.(b) Bituminous oil base primer shall be applying on cleaned roof surface @ 0.30 Litres/Sq.m and the surface shall be allowed to dry. (c) APP polymer modified approved membrane 3 mm thick, non woven, polyester, weighing not less than 3.5 Kg/Sq.m and laying on roof surface and parapets with laps, overlaps and sealing joints as specified and shall be applied completely by torch application method. Each strip shall overlap the preceding one by at least 10 cm at the longitudinal edges and 15cm at the ends.(d)Finally, a two coat of solar reflective bituminous aluminium paint @ 0.15 litre/Sq.m shall be applied on the top of membrane surfaces.Note;The treatment shall be carried out as per manufacturers instructions and through authorised applicator of manufacturer. |
| 126 | M&L10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. (Note : WPC will be measured and paid separately as supply only). |
| 127 | Supply only Integral waterproofing compound |
| 128 | S&F 18/19mm thick colour PVC Prelaminated board fixed to timber frame work as in cup board shutter/Shelves pelmet box and similar items fixed in repair complete all as specified and directed. |
| 129 | S&F Auto closing hinges 35mm of 0 crank (KH-001) or B crank (KH-002) openable at 110 degree for kitchen cabinet shutters fixed complete all as specified and directed |
| 130 | S&F ball bearing runners telescopic (KTS-20) full extension load capacity 50Kgs (length upto 45 cm ) etc fixed complete all as specified and directed |
| 131 | S&F stainless steel handle 100mm size for kitchen cabinet shutters fixed in repair complete all as specified and directed |
| 132 | S&F Chromium plated stainless steel wire basket (storage basket) pull out type for large utensils size 480X500X300mm of grade 304 with necessary fixing clips etc complete all as specified and directed Make- Godrej |
| 133 | S&F Chromium plated stainless steel wire basket (storage basket) pull out type for large utensils size 480X500X150mm of grade 304 with necessary fixing clips eetc complete all as specified and directed Make- Godrej |
| 134 | S&F Chromium plated stainless steel wire basket ( plate basket) pull out type for large utensils size 380X500X150mm of grade 304 with necessary fixing clips etc complete all as specified and directed Make- Godrej |
| 135 | S&F Chromium plated stainless steel wire basket ( cup and saucer basket) pull out type for large utensils size 380X500X100mm of grade 304 with necessary fixing clips etc complete all as specified and directed Make- Godrej |
| 136 | S&F Chromium plated stainless steel wire basket ( Cutlery basket) pull out type for large utensils size 380X500X100mm of grade 304 with necessary fixing clips etc complete all as specified and directed Make- Godrej |
| 137 | Dismantling / Demolition of existing roof terracing of cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness and in any position on top of roof of building by chiselling or any other suitable method to avoid any damages to existing roof of building, cleaning the surface of roof with brush / mechanical brush and with water thoroughly to remove all loose materials / dust / dirt to expose the bare concrete of roof slab and removal of rubbish / demolished materials outside MD land etc. complete all as specified and directed. |
| 138 | M&L PCC (1:2:4) type B-0, averaging 40mm thick using 12.5mm graded stone aggregate as in levelling / padding course over roof of building and to cover negative slope into proper slope required mixed with WPC as per manufacturers instructions; finished even & fair without using extra cement, complete all as specified and directed. Note; Water proofing compound shall be measured & paid separately. |
| 139 | M&L Providing cement concrete Type B0 1:2:4 12.5mm graded aggregate) in kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer in Charge |
| 140 | Supply only polymer based lilquid water proofing compound. |
| 141 | M&L Chipping, removing, carefully loose concrete work by low impact Hammer/Breaker without damaging the structure / structural member and cleaning and disposal of debris out side the MD premises etc complete as directed. Hard concrete should not be removed by force. |
| 142 | M&L Cleaning existing reinforcement with wire / rotary wire brush, making the steel surfaces free from loose material dirt etc. complete and applying one coat of rust remover on the rebarsincluding cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coat, complete as directed.Note: Mode of measurment shall be superficial area of concrete surface. |
| 143 | M&L Anticorrosive treatment to reinforcement by application of two coats on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be by brush only. |
| 144 | Providing and fixing additional steel bar in various structural elements like column beams and Slab etc. including drilling bending and fixing the bars tying with preleft binding wires etc. complete, Steel shall be provided on the basis of 1% of volume of concrete, anchoring reinforcement bar in existing RCC member shall be in holes of minimum 10 d depth for 8 to 12 mm dia. Note:Anchoring reinforcement bar in existing RCC member will be measured and paid separately. |
| 145 | M&L Anchoring reinforcement bar in existing RCC member in holes of minimum 10d depth for 8 Nos to 12 mm dia. Bars and grouting in position with locfix of fosroc or equivalentincluding drilling of holes. cleaning etc. complete. (Only applicable for complete recasting).Make:Dr Fixit/ Fosroc/ Or Equivalent. |
| 146 | M&L Cleaning all loose laitance on the sub concrete strata & apply one coat of epoxy bonding agent on exposed concrete surface.Make: Dr Fixit Epoxy bonding agent or Equivalent. |
| 147 | M&L 20mm thick (average) polymer modified mortar including keeping the surface moist and curing with water for 5 to 7 days etc complete all as specified and directed.Note: Thickness of single coat to be maintained as per manufacturer instructions.Make: Polymer Mortar HB of Dr Fixit or Equivalent. |
| 148 | M&L 30mm thick (average) polymer modified mortar including keeping the surface moist and curing with water for 5 to 7 days etc complete all as specified and directed.Note: Thickness of single coat to be maintained as per manufacturer instructions.Make: Polymer Mortar HB of Dr Fixit or Equivalent. |
| 149 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage. |
| 150 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 18 module including white plates with frame upto 18 module )for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed.Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 151 | One light point controlled by switch5 Amp single pole one way |
| 152 | One Fan point controlled by switch5 Amp single pole one way |
| 153 | One bell point controlled by switch5 Amp single pole one way |
| 154 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 155 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 156 | One light point controlled by switch5 Amp single pole two way |
| 157 | All as per Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 158 | S&F in replacement bell ding dong elelctric 230V ACsingle pole etc complete all as specified and directedby Engineer-in-Charge |
| 159 | S&F in replacement Modular Switch, 6 Amp, one way, one Module as per existing.etc complete all as specified and directedby Engineer-in-Charge |
| 160 | S&F in replacement Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directedby Engineer-in-Charge |
| 161 | S&F in replacement Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directedby Engineer-in-Charge |
| 162 | S&F in replacement Modular Socket Outlet6 Amp,3 pin, combined two module etc as per existing complete all as specified and directedby Engineer-in-Charge. |
| 163 | S&F in replacement Modular Socket Outlet6 Amp / 16 Amp - 2/3 pin combined two moduleas per existing etc complete all as specified and directedby Engineer-in-Charge |
| 164 | S&F in replacement Modulartelephone Socket Outlet6 Amp combined two moduleas per existing etc complete all as specified and directedby Engineer-in-Charge |
| 165 | S&F in replacement Modular Bell push, 6 Amp, one module etc complete all as specified and directedby Engineer-in-Charge |
| 166 | S&F in replacement ModularFan Regulator step type, 1 module Suitable for 1200 mm sweepetc complete all as specified and directedby Engineer-in-Charge |
| 167 | S&F in replacement lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directedby Engineer-in-Charge |
| 168 | S&F in replacement ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directedby Engineer-in-Charge |
| 169 | S & F in replacement double doorSheet metal enclosures factory made DBs Vertical 4 way TPN, 415 volts, including 63 Amps MCCB 25 KA protection class IP-42, suitable for fixing of MCBs,etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 170 | S & F in replacement double doorSheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42, Concealed in wall suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 171 | S&F in replacement MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, \"B\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 172 | S&F in replacement MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, \"C\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 173 | S&F in replacementLED lighting fixture, environmental friendly, energy efficient ready to use packLED Tube light fitiing 20 Watt with LED light source 6500 K,input voltage 240V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cableof size 0.5 Sqmm withcompletewith all accessories etc complete all as specified and directedby Engineer-in-Charge Make: Philips Smart bright batten (Cat. No. WT150C LED 20S 6500 PSU L120) or equvalent in Make |
| 174 | S&F in replacementLED lighting fixture with extruded environmental friendly, energy efficient ready to use packLED Tube light fitiing 10 Watt with LED light source 6500 K,input voltage 140V-270Vwith uniform light output, with all accessories including its connection with 2 core seathed cableof size 0.5 Sqmm withetc complete all as specified and directed by Engineer-in-Charge.Make:Crompton/Bajaj (Cat. No. 830413 ,IVORA LED Batten 10W CDL)/Havell or Equivalent |
| 175 | S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit 12 W LED ,IP65 ,IK 08 rated product luminaire comprising of high brightness LEDs complete with all accessories prewired and includingconnecting up with & including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified and directedby Engineer-in-ChargeMake:Crompton/Bajaj (Cat. No. 830321 ,IVORA LED BulkHead 10W CDL)/Havell or Equivalent |
| 176 | S & F LED Bulb 9 Watt inverter type suitable for \"B-22 type to fix on batten holder and wall light complete all as specified Make:Crompton/Bajaj (Cat. No. 830328 , LEDZ Inverter Lamp 9W CDL B22)/Havell or Equivalent |
| 177 | S&F in replacement energy saving and environmental friendly long life LED street light 30 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source,surge protection upto 4 kv and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etccomplete all as specified and directed by Engineer-in-ChargeMake: Crompton/Bajaj/Havell (Cat. No.STR-30W, LHEXAMP7PN6K030) or Equivalent |
| 178 | Supply & fix in replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directedby Engineer-in-Charge |
| 179 | S&F sub main wiring6 Sqmm single core,2 Run PVCinsulated, unsheathed, FRLSH stranded copper conductor cablewith 6 Sqmm, one Run PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn throughand including Concealed in wall with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Three run of 6 sq.mm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Conduitshall be measured as one unit |
| 180 | S&F sub main wiring concealedwith two single core PVCinsulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn throughand including PVC Conduit 20 mm diaISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring(For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Conduit shall be measured as one unit |
| 181 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts& washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precostRCC(1:2:4)mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm C/C,both way, lifting arrangement complete including all necessaryearth work etc complete all as specified and directedby Engineer-in-Charge |
| 182 | Taking down electric meter complete and refixing with complete wire, connection nut, screw, wire and painting of metal boxes complete all as specified and as directed. |
| 183 | Taking out/downcarefully and opening of existingwater Geysers of 25 Ltrs capacity,from any position, of any make etc & refixingafter reassembling andafter repair /replacement of spare parts/ material/items, at the desired locationand making necessary water inlet, outlet & electric connectionsto make in functional by using material/parts of minor nature such as screws, insulation tape, nuts, bolts, washers,fastner,flexible geyser pipe one set etc including cleaning and painting with spray painting to required gloss with white synthetic enamel paintto complete body & writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge |
| 184 | Supplyand fix electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including Flexible pipe 2 set, fastner fixed in wall Complete etc.Make:Bajaj (Shield Series Crest 25L)/Racold/Havells or equivalent |
| 185 | Supply and fix of Hot and cold Connection pipe 15 mm size of 300 mm longcomplete all as specified with all fittings and jointsetc complete all as specified and directed by Engineer-in-Charge |
| 186 | Taking down carefully Ceiling fan of 1200/1400 mm complete set and depositing in store yard complete all as specified and directed by Enginner in Charge. |
| 187 | Supply and fixing ceiling fans complete with blades, down rods,and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC),without remote all as specified and directedMake:Bajaj/ Crompton/Orient/Havells (PRO 26,1200DC26W) or Equivalent |
| 188 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm.Make : Make:Crompton/Bajaj/Havell or equivalent |
| 189 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m Sweep with, blades, and frame and louvers complete all as directed and specified by Egineer-in-Charge.Make:Crompton/Bajaj Cat. No. 70069, Supreme Plus 300mm1400 RPM IND EX Fan)/Havell or Equivalent |
| 190 | Excavation in trenches n\" exc 1.5 m wide and n\" exc 1.5 m in depth and n\" exc 10 Sq m on plan and getting out in Soft / loose soilall asdirected. |
| 191 | Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cmall as directed. |
| 192 | Cutting and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 80 mmall as directed. |
| 193 | Taking out old Aluminium Service of any size in trenches/wall/floor complete all as specified and directed. |
| 194 | M&L Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried vertically in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal groundlevel surrounded from all sides with mixture of charcoal and common salt in alternate layers, electrode connected to and including galvanised iron earth lead strip of size32mm x 6mm upto 7.5 m from earthing by means of bolts, nuts and washers of galvanised ironor steel including neccessary excavation and earth work in any type of soil, removal of surplus soil to a distance n. exc 50 m, PCC 1:3:6 type C-1 earth chamber of outer dimentions 60 cm x 60 cm x 60 cm and internal dimentions 30 cm x 30 cm x 45 cm with RCC 1:2:4 type B1 cover reinforced with 6mm dia mild steel round bars @ 15 cm c/c both way, mild steel angle iron frame made of MS angle iron of size 40mm x 40mm x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, GI pipe 40 mm dia light grade with required fittings for protection of GI earth strip from earth plate to test point / plant / machineries buried in ground, laid under floors/ plinths or fixes on walls or concealed in walls etc; both to be provided to the extent as required at site, 20 mm dia GI pipe medium grade for watering arrangements with funnel internally secured with wire mesh all as shown in electricalplate No.3 of SSR Part I, complete all as specified and directed, including testing on completion. (Note : GI earth strip and GI protection pipe upto 7.5 metre length shall be included in this item.) |
| 195 | M & L for LT factory made panel outdoor type dust and vermin proof made up of CRCA sheet of size 3.15 mmdouble door duly mounted on MS angle iron of size 50 x 50 x 6mmgrouted on foundation as specified by manufacturer alongwithfour pole copper busbar of capacity200 Amp duly mounted on insulators complete with copper conductor control wiring of size not less than 1.5 sq mm complete with provision of the following including PCC foundation & earthwork etc:-(i) Incoming- 4 Pole MCCB 125 Amps, 50 Hz, 415 V with rupturing capacity 16/25 KA- 01 No (ii) Outgoing-4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA -04 Nos (iii) Outgoing- MCB TPN 32 Amp -01 Nos (spare) (iv) LED RYB indication lamp-01 set |
| 196 | M & L for LT factory made panel outdoor type dust and vermin proof made up of CRCA sheet of size 3.15 mmdouble door duly mounted on MS angle iron of size 50 x 50 x 5mmgrouted on foundation as specified by manufacturer alongwithfour pole copper busbar of capacity100 Amp duly mounted on insulators complete with copper conductor control wiring of size not less than 6 sq mm complete with provision of the following including PCC foundation & earthwork etc:-(i) Incoming- 4 Pole MCCB 63 Amps, 50 Hz, 415 V with rupturing capacity 16/25 KA- 01 No (ii) Outgoing-4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 10 KA -03 Nos (iii) Outgoing- MCB TPN 32 Amp -01 Nos (spare) (iv) LED RYB indication lamp-01 set |
| 197 | M & L for GI pipe medium gradeof size 80 mm dia passing under the road / wall for protection of cable complete all as specified and as directed. |
| 198 | M & L for GI pipe medium gradeof size 50 mm dia passing under theroad / wall / on street light pole ,ceiling fan hanging for protection of cable complete all as specified and as directed. |
| 199 | Supply, laying,testing and commissionnig ofLT UG cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cableincluding material and labour for all jointing/connecting material as requiredsize, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of size 35 sq mm x 3.5 core complete all as specified and as directed. |
| 200 | Supply, laying,testing and commissionnig of LT UG cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cableincluding material and labour for all jointing/connecting material as requiredsize, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of size 16 sq mm x 4 core complete all as specified and as directed. |
| 201 | Supply & laying of DWC HDPE pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge |
| 202 | Supply and fix GI pipes, medium gradeincluding necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etclaid intrenches / walls / floors etc for followingpipe of diacomplete all a s specified and as directed. |
| 203 | (a)50mm bore |
| 204 | (b)20mm bore |
| 205 | Taking out GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etclaid intrenches / walls / floors etc and refix or laid as per direcion including all necessary accessories for followingpipe of diacomplete all a s specified and as directed. (Note: Excavation ,returning,removing is included in the above rate) |
| 206 | (a)50mm bore |
| 207 | (b)20mm bore |
| 208 | Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for followingGI pipe of dia complete all asspecified and as directed. |
| 209 | (a)50mm |
| 210 | (b)20mm |
| 211 | S& F in repairs high pressure polythelenefloat valve with PVC ball suitale for fixing to GI pipe of 20 mm dia all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy