| 1 | Material & Labour for 100mm thick broken stone or boulder,Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 2 | Supply only Intergral waterproofing compound complete all as specified and directed. |
| 3 | Material & Labour for Precast cement concrete block masonrywith solid blocksexc 10 cm in width in Plain Cement Concrete 1:2:4 type B-1 and setting in cement mortar 1:4 complete all as specified and directed. |
| 4 | Material & Labour for Providing precast cement concrete louvres and jallies, 45mm thick(measured solid), including all mould- ingsbut excluding frame set in Cement Mortor 1:4 type B0 1:2:4 (12.5 mm graded aggregate) complete all as specified and directed |
| 5 | Cutting chases, pinning in, making good to facings where required and pointing in cement motor 1:3 to ends or edge of landings, steps, cillls sunset sleeves lintels, etc and cutting changes for concrete water tubing or concealed conduit wiring etc and making goods cutting not exceed 10 cm girth complete all as specified and directed |
| 6 | Taking down chowkhats or frames without taking off the shutters from the framesexceeding 1.50 sqm and not exceeding 4.00 sqm each and stacking for issuing under credit complete all as specified and directed. |
| 7 | S & F Second class hard wood plain solid chowkhats and frames wroughtframed rebated on the solid, rounded or chamferred, put together with glue pinned at joints, complete all as specified and directed. |
| 8 | S&F 40mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and directed |
| 9 | Material & Labour forSecond class hard wood Glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, guaze etc. (without sash bars) edges of framing plain chamferred or rounded fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 10 | Supply and fix in repairs for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 11 | Supply & Fixing for Floor Door Stopper of Aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floors 140 mm complete all as specified and directed. |
| 12 | Supply & Fixing for Butt hinges medium weight cold rolled mild steel, and fixed 100 mm size complete all as specified and directed. |
| 13 | Supply & Fixing for Aluminium anodised barrel tower bolts extruded section 200 mm size complete all as specified and directed. |
| 14 | Supply & FixingExtruded aluminium alloy handles fabricated type anodised size 150 mm complete all as specified and directed. |
| 15 | Supply & Fixing for Aluminium alloy anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed 300mm long complete all as specified and directed. |
| 16 | Supply & Fixing in repair 100mm extruded brass handles, fabricated type polished complete all as specified and directed |
| 17 | Supply & Fixingin repair 100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 18 | Supply & Fixing for Ball catches with8 mm dia steel ball and brass body and striking plate including letting complete all as specified and directed. |
| 19 | Supply & Fixing for 25 mm dia SS drapery rod , including brackets, decorative knobs at both ends & curtain rings 8 Nos (minimum) completeall as speccified and directed. |
| 20 | Material & Labour for Anodised aluminium snap grid frame work for false ceilingsize of grid 605 x 605 mm complete all as specified and directed. |
| 21 | Material & Labour for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 22 | Material & Labour for Perforated particle board/ tiles 16mm thick for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed |
| 23 | Material & Labour for Cement concretetype B0,1:2:4 using 12.5mm graded stoneaggregate,25mm thick for sub base of floors completeall as specified and directed. |
| 24 | Material & Labour for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade complete all as specified and directed. |
| 25 | Material & Labour for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade complete all as specified and directed. |
| 26 | Material & Labour for Granite (of any type) tiles 18-20mm thick machine cut, bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 27 | Material & Labour for plain cement concrete 75 mm thick of 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in levelling course of sub floors, sub-base, floors and paving etc., complete all as specified and directed. |
| 28 | Taking down cement plaster on brick or stone walls, ceilings, etc including racking out Joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 29 | Material & Labour for Rendering with Water Proofing Compound in Cement Mortor 1:4, 15mm thick on other thanfair faces of brick work or concrete surfaces complete all as specified and directed.Note : WPC shall be measured and paid separately |
| 30 | Material & Labour for Rendering in Cement Mortor 1:6, 10mm thick on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 31 | Material & Labourfor Screed bed or bedding layer of mortor 15 mmthick in Cement Mortor 1:4 for laying floor finishes complete all as specified and directed. |
| 32 | Material & Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces with Cement Mortor 1:4as in backing coat of skirting /dado complete all as specified and directed. |
| 33 | Material & Labourfor Screed bed or bedding layer of mortor 20 mmthick in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 34 | Material & Labour for applying two coats of cement base paint over primer on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed. |
| 35 | Material & Labour for prepation of newly plastered wall surfaces and applying two coats of distemper oil-emulsion over a coat of primer over 3mm thick wall care putty on wall on wall complete all as specified and directed . |
| 36 | Material and labour for complete removal of existing treatment from old wall surfaces and finishing walls with Acrylic Smooth exterior paint of required shade over priming coat of exterior primer complete all as specified and directed. Note : (Height of bldg is upto 15 mtrs andContractor has toQuote therate accordingly and nothing extrawill be allowed later. ) |
| 37 | Material and labour for complete removal of existing treatment from oldwall surfaces, applying plaster of paris putty of 2 mm thickness andapplyingtwo coats of acrylic emulsion distemper over acoat of chalk whiting primer completeall as specified and as directed. |
| 38 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames of stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 39 | Supply & Fixing ofSheet glass,4.00 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqmin each pane complete all as specified and directed . |
| 40 | Material & Labour for painting old painted surfaces of any description, not other wise described over 10cm width or girth with two coats of synthetic enamel paint complete all as specified and directed. |
| 41 | Demolition of Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 42 | Dismantling ceiling boards any description any thickness including cover fillets/grid system etc complete all as specified and directed. |
| 43 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 44 | Material & Labour in repair for 18/19mm Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed. |
| 45 | Removalof debris/building material out side the campus including loading and unloading, etc to a distance exc 5Km but n exc 10 km out side the MD land complete all as specified and directed. Note:- Location and permission of depositing the building materials/debris disposal outside the MD land shall rest with contractor at his own arrangement, Rate quoted by the Contractor shall be inclusive of these charges and nothingetc will beadmissable. |
| 46 | Taking down old copper/aluminium point wiring (light, fan, socket or power) complete, including fitting and fixtures such as switches, sockets, ceiling roses, pendants, regulators, sockets, light fittings, DB, MCBs etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed |
| 47 | Taking down old submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces complete all as specified and directed. |
| 48 | Taking down Ceiling Fan of any type any sweep from the ceiling and refixing the same after painting in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after clening all dustincluding electrical connection complete all as specified and directed. |
| 49 | Taking down exhaust fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed. |
| 50 | Refixing only exhaust fan (In Repair) and connecting up including provision of cable from celling rose/connector to fan complete all as specified and directed. |
| 51 | Material & Labour for painting of exhaust fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed. |
| 52 | Supply & Fixing for 1.5 sq mm Copper Wire for a length of 90m (Red), Class 2 Conductor (100% Copper), Heat Resistant & Flame Retardant- Ideal for Domestic & industrial use (WHFFDNRA11X5) complete all as specified and directed. Note- (a) The 90 mtr copper conductor used as phase, neutral and earth conductor measured as three length drawn throughexisting conduit. |
| 53 | Supply and fixing LED retrofit tube battern fitting 1 x 18/ 20W, powder coated white finish 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 54 | Material & Labour for concealed Point wiring one light point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 55 | Material & Labour for concealed Point wiring one exhaust fan point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 56 | Material & Labour for concealed Point wiring one switch socket outlet point controlled by 5 Amps switch on independent board complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 57 | Material & Labour for concealed Point wiring one switch socket outlet point controlled by 5 Amps switch on same board complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 58 | Material & Labour for concealed Point wiring one bell/buzzer point controlled by on bell push complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 59 | Material & Labour for concealed Point wiring for one 3 pin socket outlet, 15 Amps and on independent board complete with 4 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases will be Measured and paid seperately. |
| 60 | Supply & Fixing modular fan regulator step type 120 W,2 model complete all as specified and as directed. |
| 61 | Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FR cable 1100 volts grade multistranded copper conductor cable with two run of 2.5 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories in concealed conduit all as specified and as directed. |
| 62 | Supply & Fixing for Switch Modular 6A single pole, one way, 1 module complete all as specified and directed. |
| 63 | Supply & Fixing for Switch Modular 16A single pole, one way, 1 module complete all as specified and directed. |
| 64 | Supply & Fixing for Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 65 | Supply & Fixing for Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 66 | Supply & Fixing for Bell push1 module 6 Ampscomplete all as specified and directed. |
| 67 | Supply & Fixing for Buzzer ding dong AC 230 volts single pole complete all as specified and directed. |
| 68 | Supply & Fixing for Modular White cover plate with frame,2 module complete all as specified and directed. |
| 69 | Supply & Fixing for Modular White cover plate with frame3 module complete all as specified and directed. |
| 70 | Supply & Fixing for Modular White cover plate with frame,6/8 module complete all as specified and directed. |
| 71 | Supply & Fixing for Modular metel flush box ,2 module complete all as specified and directed. |
| 72 | Supply & Fixing for Modular metel flush box 3 module complete all as specified and directed. |
| 73 | Supply & Fixing for Modular metel flush box 6/8 module complete all as specified and directed. |
| 74 | Supply & Fixing for Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 75 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and20mm bore medium grade GI pipewith funnel and wire mesh for watering including necessaryexcavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & Reinforced Cement Concrete cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR( Part-I) of 2009.Note : The unit rate includes earthing wire, and protection pipe upto 7.5 metre. |