| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 4 | Cold twisted bars |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 6 | Foundations, footings, bases for columns. |
| 7 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 8 | Of area 3 sq. metres and below |
| 9 | Deduct for not providing hinges in doors, windows or clerestory window shutters with : |
| 10 | Stainless steel butt hinges with stainless steel screws : |
| 11 | For 2nd class teak wood and other class of wood shutters. |
| 12 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 13 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 14 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. |
| 15 | Overall width 35 mm. |
| 16 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : |
| 17 | 300x16 mm |
| 18 | 250x16 mm |
| 19 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 20 | 200x10 mm |
| 21 | 150x10 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 23 | 125 mm |
| 24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 25 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 26 | 300x16 mm |
| 27 | 250x16 mm |
| 28 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 29 | 300x10 mm |
| 30 | 250x10 mm |
| 31 | 200x10 mm |
| 32 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 33 | 125 mm |
| 34 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 35 | Twin rubber stopper |
| 36 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 37 | 100 mm diameter |
| 38 | 150 mm diameter |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 40 | Single socketed pipes. |
| 41 | 75 mm diameter |
| 42 | 110 mm diameter |
| 43 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 44 | Bend 87.5° |
| 45 | 75 mm bend |
| 46 | 110 mm bend |
| 47 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 48 | 75 mm |
| 49 | 110 mm |
| 50 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 51 | 12 mm cement plaster of mix : |
| 52 | 1:6 (1 cement: 6 fine sand) |
| 53 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 54 | 1:6 (1 cement: 6 fine sand) |
| 55 | 6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 56 | Neat cement punning |
| 57 | Pointing on tile brick work with cement mortar 1:3 (1 cement: 3 fine sand) : |
| 58 | Flush / Ruled/ Struck or weathered pointing. |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 60 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 61 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 62 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 63 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 64 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 65 | Refixing old glass panes with putty and nails . |
| 66 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 67 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 68 | Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 69 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 70 | Long pattern W.C. pan of size 580 mm |
| 71 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 72 | 10 litre capacity - White |
| 73 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 74 | White solid plastic seat with lid |
| 75 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 76 | Flat back wash basin of size 550x400 mm. |
| 77 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 79 | 20 mm nominal outer dia. Pipes. |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 81 | 40 mm nominal outer dia. Pipes. |
| 82 | 50 mm nominal outer dia. Pipes. |
| 83 | Providing and fixing brass stop cock of approved quality : |
| 84 | 15 mm nominal bore |
| 85 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 86 | 45 cm length |
| 87 | 15 mm nominal bore |
| 88 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 89 | 15 mm nominal bore. |
| 90 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 91 | 15mm nominal bore |
| 92 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 93 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 94 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 95 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 96 | Providing and fixing fly proof S.S. wire gauze to windows and clerestory windows using S.S. wire gauze with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete as per direction in charge. |
| 97 | Removal of leakage & Chockage from G.I / S.C.I pipe line including thecost of M-seal , cement etc all complete as per direction of engineer in charge. |
| 98 | Cleaning of all manhole / chambers of all sizes in the compound complete including cleaning of adjacent sewer line, removal of earth, silt, slush, brickbats, garbages and other refuses, disposing the same off to dumping site in township complete as per direction of Engineer-in-charge. Cleaning of manholes / chamber shall be done as & when required manually or mechanically. Note :- Rates includes the cost of cleaning of manhole /chamber , de-watering, if required including cleaning of adjacent sewer line , removing of manhole / chamber cover and keeping the same back in position after cleaning etc. complete. Payment will be made for each cleaning. |
| 99 | Providing manual assistance for plumbing, sewer, masonary & carpentry work which are not covered above and are not susceptible to measurement. Note : For this item, the contractor will provide one skilled labour for required job i/c minor fittings like nails,screws,fevicol spun-yarn, safeda etc. Minimum time shall be reckoned as 1/2 day if the time required for doing various jobs assigned is less than even the 1/2 day. 1/2 day working shall be treated as one job. |
| 100 | Arranging beldar or similar unskilled labour for working as and when required, as per direction of engineer in charge for items which are not responsive for measurement. 1/2 day working shall be treated as one job. |
| 101 | Repairing of the following i/c other fittings of C.P. brass etc. as per direction of Engineer-in-charge. |
| 102 | Low level cistern |
| 103 | By replacing complete internal fittings/ fixtures and ball cock, complete as required. |
| 104 | By Replacing P.V.C. handles /lever , washer etc.in PVC Cistern complete as required . |
| 105 | Repairing of leakage and chockage in main and branch water pipe lines of 15 mm to 25 mm as and when required i/c the cost of jointing material such as Teflon tape, jute,tee,elbow,socket etc. required for sealing of leakage joints. Pipe & union, if required to be replaced, shall be paid separately. |
| 106 | Arranging electric welding machine at site for repairing works etc. with necessary cables and other T&P including the cost of operator and electrodes but excluding the cost of necessary steel sections complete as per direction of Engineer-in-charge. (Note: One day work at one site shall be taken as one job.) |
| 107 | P/F C.P.brass waste coupling for wash basin / sink of approved quality |
| 108 | (A) 32 MM Nominal size |
| 109 | Making Steel Windows / Door shutters/ Ventilators/ Garrage doors etc. serviceable by Oiling & greasing for efficient and smooth working as per direction of Engineer in charge. |
| 110 | Taking out Pipal plant and other plant from walls and terrace including dismantaling brick work /Terrace treatment,uprooting and repairing the same including necessary scaffolding arrangement etc. Complete as per direction of engineer in charge.(If two or more sapling of Pipal trees and other plant are at same place that should be treated as one up to plan area of 0.5 sqm.) |
| 111 | Providing and fixing PVC cover of approved make having proper locking arrangement over PVC water storage tank of capacity 250 to 500 ltr. capacity. |
| 112 | Providing and fixing C.I. brackets for wash basin /kitchen sink of single/pair as required at site of approved quality all complete i/c dismentling of old unserveceable bracketsas & fixing same as per direction of Engineer in charge. |
| 113 | Repairing of aluminium door floor spring and pivot complete as per direction of engineer in charge. |
| 114 | Repairing of aluminium door shutters including replacing of hinges screws ets by tacking out the existing aluminium door and refixing in same position all complete as per direction of engineer in charge. |
| 115 | Removal of old damaged W.C.Pan by dismantling floor and repair of floor as required including disposal of rubbish beyond municipal limit etc. complete. |
| 116 | Attending complaint at other station with semi skilled & unskilled manual assistance for plunmbing,carpentry or masonetc complete as per the direction of the Engineer in Charge. |