| 1 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | M&L Brick work using sub class old bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 4 | M&L Brick workexcept Bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 5 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 6 | M&L for rendering 10mmthick in ceiling on brick work or concrete surfaces in CM (1:3), finished even and smooth without using extra cement all as specified and directed. |
| 7 | M&L for rendering 10mm thick internal surfaces on fair faces of brick work or concrete in cm (1:6) complete all as specified and directed. |
| 8 | M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC 2% by wt of cement.Note:-WPC measured and paid separatly complete all as specified and directed. |
| 9 | Supply only liquid water proofing compound ISI marked. |
| 10 | M&L preparing newly plastered surfaces of wall and applying complete wall and ceiling with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer complete all as specified and directed. |
| 11 | M&L Preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 12 | Demolition of Concrete in ground floors and pavings including floor tiles n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 13 | M & L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM (1:4) .including taking down existing tiles. |
| 14 | M & L for PCC (1:2:4) type B-1, 25 mm thick, using 20mm graded stone aggregate complete all as specified and directed. |
| 15 | M & L for light shed virified ceramictiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with CM (1:4) complete all as specified and directed .Notes : Shade of the tile including colour, design and pattern shall be |
| 16 | M & L for light shed virified ceramictiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skitting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thickrendering bed or bedding layer with CM (1:4) complete all as specified and directed .Notes : Shade of the tile including colour,design and pattern shall be |
| 17 | M & L for coloured glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in cement mortar 1:4as backing for tiles complete all as specified and as directed. (Note : Work will be carried out as in repair of patches in lieu of existing broken flooring/wall tiles) |
| 18 | M & L Machine cut Kota stone slab flooring 18-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) incl dismantling of existing kota stone complete all as specified and directed. |
| 19 | M & L Kota stone slab 18-22 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and incl 10mm thick rendering in cement mortar (1:4) , on fair faces of brick work or concrete surfaces as backing including dismantling of existing kota stone complete.(Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) |
| 20 | S & F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 21 | Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame) complete all as specified and directed. |
| 22 | Taking down chowkhats or frames exc 1.5 Sqm ( without taking shutters from the frame) complete all as specified and directed. |
| 23 | S & F Powder coated three/two track aluminium frame/shutters for doors, windows, ventilators sliding/openable etc with joining cleat for fixing, locking arrangement, rubber beading, screws,etc including taking down and making the surface good complete all as specified.Note : (i) Glazing and wire mesh shall be measured and paid separetely. (ii) Item shall be paid as per weight of aluminium section (iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. complete all as specified and directed. |
| 24 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane(to be fixed upto four storey of bldgs) complete all as specified and directed. |
| 25 | Supply only Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and directed. |
| 26 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 27 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed |
| 28 | S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed. |
| 29 | S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed |
| 30 | PVC (SWR) vent cowl for 110 mm bore pipe |
| 31 | PVC (SWR) multi floor trap with grating 75 mm dia including jointing with solvent cement |
| 32 | S & F of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 33 | Taking down of existing GI Tubing 15 mm dia complete all as specified and directed. |
| 34 | Taking down of existing GI Tubing 20 mm dia complete all as specified and directed . |
| 35 | Supplying and laying as in repair of CPVC pipes 16mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/floors complete all as specified and directed. |
| 36 | Supplying and laying as in repair of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/floors complete all as specified and directed. |
| 37 | S & F of CPVC pipes MBTA/FBTA fittings such as tee, elbow, socket and Tank union etc of 16 mm outer dia complete all as specified and directed. |
| 38 | S & F as in repair of CPVC pipes MBTA/FBTA fittings such as tee, elbow and socket etc of 20mm outer dia complete all as specified and directed. |
| 39 | S&F in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed. |
| 40 | S&F in repair 15 mm dia bore pillar taps cast copper alloy, with capstan head, chromium plated, fancy type, screwed down high pressure, with or without lettered\"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed. complete all as specified and directed. |
| 41 | S&F in repair 15 mm dia stop valves/angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe. complete all as specified and directed. |
| 42 | S&F CP health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etccomplete all as specified and directed. |
| 43 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 44 | S&F in repair 15 mm dia two way angle valves/Bib taps, cast copper alloy,fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 45 | S&F in repair 15 mm dia two way bib taps, cast copper alloy,fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 46 | S &F as in repair chromium plated Shower rose 15 mm size, 125mm long with arms complete all as specified and directed. |
| 47 | S&Fvitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopperincluding brackets or fixed to walls with anchor fastnersall as specified and directed. |
| 48 | S & F in Repair of Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. |
| 49 | S & F as in repair5/10 litre PVC valveless, syphonic action type, Dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 50 | S&F in repair rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltrhoisted and fixed in position complete all as specified and directed. |
| 51 | S&F Tubular towel rail, 20mm dia, D type, 60cm long between flangesallas specified and directed. |
| 52 | S&Ftubulartowel ring 165mm external dia as specified and directed |
| 53 | Dismantling of asbestos cement corrugated sheets as in roof coverings complete all as specified and directed. |
| 54 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (AZ-150) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 55 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (AZ-150)of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete as specified and directed. |
| 56 | Dismantling Framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 57 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 58 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcFe 410 W (Gde E - 250 quality A ) complete all as specified and directed . |
| 59 | All as per item no 58 but febrication only complete all as specified and directed. |
| 60 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of Old steel surfaces complete all as specified and directed. |
| 61 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed. |
| 62 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed . |
| 63 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed . |
| 64 | S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed. |
| 65 | Taking down re-fixing Shutters of any description but exc 1 sq. m and n exc 2 sq. m each in same opening including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc. Renewal of builder\"s hardware articles, if specially ordered, shall be paid for at \"supplied only\" rates. complete all as specified and directed. |
| 66 | M&L for Hard core of gauge n exc 63mm thick of broken bricks spread leveling watering ramming to true surface complete all as specified and directed. |
| 67 | M&L for Cement concrete 1:3:6type C-2 (using 20 mm gradedstone aggregate)75 mm thick as in plinth protections, surface finished even and smooth w/o using extra cement including 3 mm thick glass dividing strip of figured glass , pin headed type, 38 mm wide inserted in position complete all as specified and directed |
| 68 | S & F forSolid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as specified and directed. |
| 69 | S & F in replacement LED lights fitting 1x 20W 220V, LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements,complete all as specified and as directed. |