| 1 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by for king repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts |
| 2 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil |
| 3 | P/L of dry stone soling duly hand packed with ramming, dressing, watering and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 5 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) Light shade using white cement all complete. |
| 6 | Engagement of Labour for Carriage of Debris |
| 7 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: (In cement mortar). |
| 8 | 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) in all complete. |
| 9 | Dismantling/Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : |
| 10 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) all complete.all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved from approved source to site of work complete. |
| 11 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) all complete. |
| 12 | Providing and fixing 5 mm thick toughened glass of approved brand and manufacture, all complete as per direction of Engineer-in-charge |
| 13 | Carriage of Sand/Stone.ag.. For an avg. lead of 10 Km by MT |
| 14 | Carriage of Material by Mannual Means for 100 Mtrs.:- Sand/Stone agg. |
| 15 | Dismantling roofing including ridges, hips valleys andgutters etc., and stacking the material within 50 meters lead. |
| 16 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 17 | Dismantling Devri Stone tiles flooring/lining laid in cement mortar,including chiselling out mortar joints,carefully removing tiles without breakage ( as far as possible), cleaning the tile of mortar, stacking the surviceable material at site as directed, and disposing of unserviceable material within a lead of 50 metres, complete as per directions of EIC. |
| 18 | Dismantling of Devri Stone cornice fixed in cement motar, including removal of backing mortar, lowering down and disposal of dismantled material within 50 metres lead, complete as directed by EIC. |
| 19 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 20 | Refixing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Fine chisel dressed all complete. |
| 21 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. NOTE:- To be used for maintenance work judicially necessary deduction for scaffolding in the existing item to be done |
| 22 | Refixing and moulded Devri Stone cornice, hand dressed or machine cut of approved design and section fixed in cement mortar (1:4), including scaffolding,anchoring,making joints,curing and finishing complete as directed by EIC. |
| 23 | Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3kg/sqm including pointing in white cement with curing complete. 18 mm thick Doongri Adanaga marble |
| 24 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) incl. Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level all complete. |
| 25 | P/L in position cement concrete in 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. |
| 26 | P/L in position reinforced cement concrete in 1 : 1.5 : 3 (1 cement:1.5 course sand: 3 Crushed graded stone aggregate 20mm nominal size) excluding the cost of centering, shuttering, finishing and reinforcement but including carriage of all materials upto site of work complete. ( all works upto floor V level ) |
| 27 | Reinforcement for RCC work including straightening cutting, bending, placing in position and binding all complete (Thermo mechanically treated bars) including all carriages complete. FE-500 D or more complete. |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc complete. |
| 29 | Structural steel work welded in built up sections, trusses. Framed work. Including cutting, hoisting, fixing in position welded and applying a priming coat of approved steel primer all complete.(Welded) |
| 30 | Providing/Fixing of CGI Colour coated (Hi-Rib) profile sheets for roofing including vertical/curved surface fixed with Polymer coated J or l hooks, bolts and nuts 8mm diameter with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead, including overlapping of sheets complete (upto any pitch in horizantal/ vertical or curved surface) excluding the cost of purlins, rafters (0.50mm thick) etc incl ridges hips/ valleys 60cm vide of colour GI sheets sheets including cost of screws/ washers all complete and cost and carraiges of materials complete. |
| 31 | Dismantling of existing wooden panelling,skirting and framing from wall, partitions or ceilings-including removal of nails screws adhesives beading and fixtures; stacking of servicible material as directed and disposal of unserviceable material within a lead of 50 metres , complete as per directions of EIC. |
| 32 | P/f of 12mm thick imported wooden panelling over 40mmx40mm size beading including cost of approved quality ,applying memamine/MDF polish of approved quality (as per directions of EIC. |
| 33 | Providing and Fixing of decorative eaves boarding of first class deodar wood in size of 300mmX300mmX40mm (Shafaq type) including fixed with nuts and bolts all complete. |
| 34 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-In-Charge 18 mm thick. |
| 35 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) all complete. |
| 36 | Carriage of Material by M.T:-Sand/Stone agg. for an avg lead of 10 Kms |
| 37 | Carriage of Material by M.T : Bricks for an avg. lead of 48 Kms |
| 38 | Supply, installation, testing and commissioning (SITC) of a circular fountain system. Includes hydraulic, electrical, control and basic civil integration works. Fountain to operate in recirculation mode with filtration. A. Hydraulic System SS Fountain Nozzles (SS-304/316, medium jet).Main Fountain Pump (5 HP, non-clog, bronze/SS).Standby / Circulation Pump (3 HP with Head as per requirement).Sand Filter with MPV (600 mm dia).Balancing Tank / Strainer Assembly.GI/UPVC Piping, fittings & valves. B. Electrical & Control System Control Panel (Pump starter, MCB, contactor, timer asPer pump specifications).3-Phase Armoured Power Cable (4C x 10 sqmm Cu) incl. laying and fitting.Power & control cabling (internal), trays & conduits.Earthing( copper) & electrical safety accessories & Servo Stabilizer 7.5KVA air cooled(180-460 Volts p2p ) . C. Mechanical Installation, Testing & Commissioning Pump, nozzle & piping installation.Pressure testing & hydraulic balancing. Electrical testing, alignment & trial run D. Civil & Miscellaneous Works Minor civil works, grouting, supports & sleeves Transportation, loading & unloading. E. Lights etc . Underwater LED Lights (18W RGB, SS body).DMX / Music Synchronization System. • All items should be of superior Quality and as per IS codes. and complete in all respects with a minimum of 1 year O&M included complete Job |
| 39 | Supply/Installation/Testing and Commissioning of Rectangular shaped RGBW architectural DMX Controlled LED flood light with integral driver & housing made of extruded Aluminum with Die-cast aluminum end caps. Product dimension of luminaire:210mm x 140mm x 149mm (with bracket). The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The nominal weight of the luminaire shall not be more than 2.7kg. The luminaire shall be equipped with high-power Cree, Osram, Lumiled or equivalent. The fixture shall have 15° beam angle , the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤3. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 40W 2040 lumens & should comply with cone diagram. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg.The product should have discreet LED and not 4 in 1 LED & should be with intergral DMX Decorder. The luminaire shall have class I insulation Philips/Wipro/Ecolink/LT/Equivalent Make. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.The job further includes replacement warranty of item (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 40 | Supply/Installation/Testing and Commissioning of 500mm long RGBW LED Rigid LinearGrazer with System wattage of 40W, min lumen output of 2100lm, 16x35° beam angle complete with power supply, suitable IP66 connectors maximum led power supply, suitable IP66 connectors, luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 1000mm x 55mm x 45mm (without bracket) and minimum weight of 2kg. The Luminaire shall have tilting adjustability +15° to - 90°. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35deg C.The product should have discreet LED and not 4 in 1 LED & should be with intergral DMX Decorder & DC driver.The luminaire should be IP66 & IK-06. The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. The bidder should also submit the BIS for proposed family of product.The job further includes replacement warranty of item (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 41 | Supply/Installation/Testing and Commissioning of IP65 cylindrical surface mounted, 10W System Wattage, housing made up of Pressure Die Cast Aluminum. luminaire 1000 lm , system efficacy 100 Lm/W, CRI 80,SDCM<5, IK rating: IK08, Class- I Electrical Insulation, Surface- Wall Mounting, Input Voltage (V), 220-240Vac,50 Hz, Operating Voltage(V), 140 - 280 Vac, Power factor(Typ. Load), >0.95, THD <5%, Operating Temp. 0⁰C - 45⁰C, Inbuitlt Surge Protection 4KV(CM/DM), HV Cut off @320V/440V Protection for 8 Hrs. with LV Cut off and Open & short circuit Protection (output side) of Philips/Wipro/Ecolink/LT/Equivalent Make. |
| 42 | Supply/Installation/Testing and Commissioning of Content Program Controller with features of Single DMX ports control minimum 300 light addresses, Works as a stand-alone or computer-driven controller, Secure Digital (SD) card drive for flexible show storage, USB 2.0 interface for downloading shows and configuring from attached PC,Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100-240VAC,Minimum Five pre configurable effects :Using light authoring software to select from five pre-defined effects, adjust effect settings such as color, speed, and brightness. Soft Copy of Catalogues with Link of the official web page of Luminaries, Test Certificates - relevant BIS R Number, UL Certificates, Third Party IEC 60598 test certificates submission is mandatory of Philips/Wipro/Ecolink/LT/Equivalent Make.The job further includes replacement warranty of item (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 43 | Supply/Installation/Testing and Commissioning of RDM-6Wall Splitter,should be able to provide 6-output DMX/RDM splitter with DMX/RDM pass-through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable,Isolated DMX/RDM Input/Outputs,Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications,Finish/Color-Polycarbonate, Certification: CE Certified of Philips/Wipro/Ecolink/LT/Equivalent Make.The job further includes replacement warranty of item (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 44 | Supply/Installation/Testing and Commissioning of Addressing Kit shall automatically write address to a whole group of interconnecting luminaires within minutes. It shall be Miniature industrial design, compact size and touch screen. It can be powered by a power bank with a Micro-B type USB port for on-site programming and testing after installation. The housing shall be extruded Aluminum with black finish weighing approx. 0.2Kg with temperature range -10°C to 40°C, input voltage of 6-24V DC and humidity range of 10 to 90% (no condensation). The product shall be compact in size, compatible with multiple types DMX512 chips, with Built-in test animation effects, SD card slot to store animation and scenes. The addressing kit shall support standard RDM protocol, searching for RDM luminaires and static detection, Color-pick functions, and can be powered by Micro-B type USB power supply of Philips/Wipro/Ecolink/LT/Equivalent Make.The job further includes replacement warranty of item (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 45 | Supply and laying of 2.5 Sq mm 3 core PVC insulated unarmoured multistrand copper flat cable as per site requirement (Salzer/Polycab/Paraflix/RR-Kabel/Equivalent Make) |
| 46 | Supply and laying of 6 Sq mm 5 core PVC insulated unarmoured copper flat cable as per site requirement (Salzer/Polycab/Paraflix/RR-Kabel/Equivalent Make) |
| 47 | Supply and laying of Armoured CAT 6 cable as per site requirement(D-Link/Polycab/Paraflix/RR-Kabel/Equivalent Make) |
| 48 | Supply and Laying of PVC Prince Pipe/HDPE Pipe of 25/32 MM as per site requirement of Standard Make. |
| 49 | Design,Fabrication,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control outdoor slopped Roof,Double Door panel Floor Mounted fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter,Phase-indicators etc with baby insulators/thimbles suitable for use at 230 Volts 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming63 Amp DP MCCB of Legrand/Siemens/ ABB//LK make = 1No. 100 Amp PN Bus bar Al Strips = 1 SetDigital VoltMeter =1 no, Digital Ammeter = 1 no , CT coils for Ammeter 300 /5A = 1 set ,phase indicators =1setOutgoing(1)16 Amps MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 08 No.(2) Suitable Timer as per site requirement(3) Suitable Surge Protection Device as per site requirementThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 50 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value. Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 51 | Supply and fixing IP 67 boxes with all accessories as per site requirement |
| 52 | Customised Al Profiles as Per site Conditions |
| 53 | Design,Fabrication,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control outdoor slopped Roof,Double Door panel Floor Mounted fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete (If Required) of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, Phase-indicators etc with baby insulators/thimbles suitable for use at 230 Volts, 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming125-160 Amp DP MCCB with extended thimbles of Legrand/Siemens/ABB//LK make = 1 no 200 Amp P-N Bus bar Al Strips = 1 Set, Voltmeter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicator =1No.(2) Generator Incomer63 Amp Four Pole Change over switch of Legrand/Siemens/ABB//LK make = 1 no., 100 Amp P-N Bus bar Al Strips = 1 Set,Voltmeter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicator =1No.(3) Bypass Switch: Single/Three Phase, Double/Four Pole 63-100 Amp,415V Ac,50Hz Bypass Switch Seimens/LK/ABB Make for bypassing 10 KVA AVR.Outgoing .(1) 1 no 200 Amp P-N Bus bar Al Strips = 1 Set(2) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No.The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 54 | Supply/Installation/Testing & Commissioning of 1-phase 10 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of AE/Chinar/Cosco/AlBA Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection Complete job. |
| 55 | P/F of sheet steel Kiosk/Canopy suitable outdoor type to house 10KVA servo stabilizer of capacities fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated. |
| 56 | Supply/Laying/Testing and Commissioning of 2-Core 50 mm sq. Al armored XLPE Insulated,PVC cable Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. |
| 57 | Supply/Excavation & Laying of GI Pipe (A-Class) of 02 inches dia with ISI Marked for Road cut and refilling of same with cement concrete. Please Enable Macros to View BoQ information |