| 1 | Earth work in Excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ),including getting out the excavated soil and disposal of surplus earth upto 50 m including dressing of sides and ramming of bottoms, lift upto 1.5 m as directed by Engineer-in- Charge as per dar-2.8.1FoundationBoundry Wall |
| 2 | Providing and laying in cement concrete 1:4:8 (1 cement:4 coarse sand:8 graded Stone aggrigate 40 mm nominal size ) i/c supply of ALL materials Labour AND T& P and curing complete. Also i/c cost of formwork in foundation &floorsFoundationBoundry Wall |
| 3 | Brick work wthi common burnt clay F.P.S.(non modular) bricks of class degignation 7.5 in foundation and plinth with (1:6) cement and C/ sand mortar i/c all Foundation/ PlinthBoundry Wall2nd Stepupto plinth beam |
| 4 | Brick work wthi common burnt clay F.P.S (non modular) bricks of class degignation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in. (1:4) cement and C/ sand mortar i/c all as per DSR No-6.4.1 Boundry Wall |
| 5 | 12 mm thick cement Plaster of mix 1:6 , sand plaster in 1:6 (1cement & 6 C/sand mortar) as per DSR -13.4.2Cold chain RoomINSIDE Cold chain RoomDeduction Openings D V |
| 6 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shuttersa) 35 mm Thick Single leafB) a) 35 mm Thick Double leaf |
| 7 | Cement Concrete flooring in 1:2:4 (1 cement: 2C/sand :4 greded stone aggregate 12.20 mm gauge stone grit size laid one layer neat cement (25 mm thick floor).Cold chain Room |
| 8 | Providing and applying white cement based putty ofaverage thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface toprepare the surface even and smooth complete. |
| 9 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and includin priming plaster main building area/boundryfloorchain clod room |
| 10 | Providing and fixing fly proof galvanized M.S. wiregauge to windows and clerestory windows usingwire gauge with average width of aperture 1.4 mmin both directions with wire of dia 0.63 mm allcomplete.With 2nd class teak wood beading 62X19 W W W |
| 11 | Providing & fixing glass panes with putty and glazingclips in steel doors, windows, clerestory windows,all complete with : 4.0 mm thick glass panes W W W |
| 12 | Painting two coats on steel or other metal surface over one coat of priming coat incl. material,labour and T&P etc. required for proper completion of work, as per DSR 13.48.3 D V |
| 13 | Wiring point for light point/fan point/ exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated single core copper conductor cable in Surface /recessed medium class PVC condute with 1.5 sq mm FR PVC Complet etc as required DSR-2022 1.10.3 |
| 14 | Supply and fixing of following sizes of medium class pvc conduit along with accessories in surface /recess i/c cutting the wall and making good the same in case of conduit as required AS per DSR - 2022 SI:1.2120 mm pipe |
| 15 | Supply and fixing metel box of 150mm x 75 mm x 60 mm deep (nominal size )on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 3 pin 5/6 A socket outlet and 5/6 Apiano type swich, connections painting, etc .As required As per DSR - 2022 1.29 |
| 16 | S/F of following moduler swich /socket on the exiting moduler plate & swich box i/c connection but excluding moduler plate etc as required AS per DSR 20225/6 A swich |
| 17 | 3pin 5/6 A socket outlet |
| 18 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronicregulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz,single phase AC Supply, earthing etc. complete as required. Ceiling fan |
| 19 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in All respect |
| 20 | Supply of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. |
| 21 | Plumbing workP/F of 110 mm dia wall face unplasticised rigid PVC rain water down pipe Conferming to IS: 13592 Type A i/c jointing With Seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expention . (i) Single socketed pipes. As Per DSR NO-12.41.2 110 mm pipe |
| 22 | Providing and fixing watercloset squatting pan (indian type pan ) with 100 mm send cast iron P or S trap , 10 ltr low lvl white pvc flushing cistern , i/c flush pipe ,with manually controller device (handle lever) conferming to IS:7231, With all fitting and fixtures complete ,i/c cutting and making good the walls and floors wherever required: White viterious china orrissa patturn W.C. pan of size 580X440 MM with integral type foot rest |
| 23 | Providing and fixing White vitreous china flat back half stall urinal of size 580x380x350 mm white pvc automatic flushing cistern , with fitting standerd size c.p. brass flush pipe ,spreaders with with union and clamps (all in c.p. brass ) with waste fitting as per IS : 2556, CI : trap with outlet grating and other coupling in C P brass i/c painting of fitting and cutting and making good the wall and floors wherever required : |
| 24 | Providing and fixing wash besin with C.I. brackets , 15mm C.P. brass PILLER TAPS 32MM C.P. brass waste of standerd pattern , i/c painting of fitting and brackets, cutting and making good the wall wherever requir : |
| 25 | Providing And fixing flexible P.V.C. waste pipe for sink or wash besin i/c PVC waste fitting Complete . Flexible pipe (a) 32 mm dia |
| 26 | Providing and fixing cpvc pipes Having tharmal stability for hot & cold water supply and all cpvc plain &brass thereded fittings , i/c fixing the pipe with clamps at 1 mm specing . this i/c jointing of pipes &fitting with one step cpvc solvent cement testing of joints complete with cpvc fitting &clamps i/c cutting & making good the walls.Enternal work Exposed on wall15 mm dia nominal bore (medium duty) |
| 27 | 20 mm dia nominal bore (medium duty) |
| 28 | Providing And Fixing C.P. brass long body bib cock of approved quality conforming to I S Standerd and weighing not less than 690 gms |
| 29 | Providing and fixing of gun metel gate valve with wheel of aproved quality . 25 mm nominal bore |
| 30 | 32 mm nominal bore |
| 31 | Providing And Fixing C.P. brass short body bib cock of approved quality conforming to I S : 8931 |
| 32 | Providing and placing on terrace (at all floor lvl ) polythelene water storage tank or approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and the base support for tank CIRCULAR TANK |
| 33 | Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. as per SI No. 251 |
| 34 | Providing and Laying ,spreading and compacting stone aggregates of specific sizes to water bound macadum specification i/c spreading in uniform thickness , hand packing ,rolling with |
| 35 | Brick masonary work in cement & coarse sand mortar 1:4 in foundation complete excluding pointing and plastering as per drawing and technical speficiations 305(B) |
| 36 | 12 mm thick plaster with Cement and Coarse Sand morter in 1:3 including supply of all material labour and T&P etc. required for proper complition of work. SI NO.-583 |
| 37 | 2.5 cm (1\") plain cement concrete floor with cement approved coarse sand 2 cm graded aproved stone laid in panels finished with 2 mm flooring coat without base concrete including supply of all materials, labour and tools and plants etc. required for proper completion of the work |
| 38 | RCC work in cement, approved coarse sand and 2cm (3/4inches) gauge approved stone ballast in portion 1:2:4 excluding supply of rainforcement, and also includind supply of material T&P etc. required for proper complition of work strength of the concrete shall not be less than M-150 as per SI No.-283 (Drain Covers) |
| 39 | Mild Steel or Iron in plain work such as reinforced concrete wrought to required shape as nessory including bending for proper complition of work and including supply of steel ,its wastage bend hooks and authorised overlaping as per SI NO.-504 |
| 40 | Laying of 80 mm thick pre moulded inter locking paver tiles over prepared surface including all labour T&P etc. required for proper completion of work. |
| 41 | Supply and fixing of information sign board including letter writing and painting etc for compelition of work Please Enable Macros to View BoQ information |