| 1 | Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc(not exceeding 1.5 mt width) for shafts, wells, cesspits and the like not exceeding 10sqm on plan depth upto 1.5 mt including disposal of excavated earth upto 1 mt from cutting edge disposed earth to be levelled and neatly dressed in. All kind of soil. |
| 2 | P/L in position cement concrete of specified grade including curing but excluding the cost of centerring and shuttering. All works upto plinth level with (1:4:8) mix 40mm aggregate |
| 3 | P/L in position cement concrete of specified grade including curing but excluding the cost of centerring and shuttering. All works upto plinth level with (1:3:6) mix 20 mm stone aggregate. |
| 4 | P/L in position specified grade of rienforced cement concrete excluding the cost of centering and shuttering, finishing and rienforcement. All works upto plinth level with (1:1.5:3) mix 20mm size aggregate |
| 5 | Centerring and shuterring including placing, strutting etc. And removal of form |
| 6 | Centering and shuttering including placing, strutting, etc. And removal of form for suspended floors, roofs,landings etc |
| 7 | Centerring and shuterring including placing, proping and removal of form for lintels, beams etc. |
| 8 | Centering and shuttering for Coloumns, Pillars, Piers, Abutments etc. |
| 9 | Centerring and shuterring for edges of slab |
| 10 | P/L in position Reinforced cement concrete in suspended floors, balconies, landings with (1:1.5:3) 20mm size aggregate. But excluding the cost of centering and shuterring. |
| 11 | P/L in position Reinforced cement concrete in Lintels, beams ete with (1:1.5:3) 20 mm size aggregate but excluding the cost of centerring and shuterring. |
| 12 | Reinforcementfor RCC work including cutting, hoisting and placing in position and binding all complete with TMT Bars |
| 13 | Providing and fixing M S Grill of required pattern in frames of windows etc with MS Flats, square and round bars etc. Including priming coat with approoved steel primer all complete. Fixed to windows by welding. |
| 14 | Providing and fixing pressed steel door frames confirmingto IS : 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50X25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together mechanical means, including MS Pressed butt hinges 2.5mm thick with mortar gaurds, lock strike plate and shock absorbers as spesified and applling a coat of approoved steel primer after pre -treatment of surface as directed by Engineer-in-charge. |
| 15 | Brickwork with common burnt clay FPS bricks of class designation 75 in foundation and plinth including curing in cement mortar (1:6) mix |
| 16 | Extra for Brickwork with common burnt clay bricks or cement concrete bricks in superstructure above plinth level upto floor five |
| 17 | 6 mm cement plaster in (1:6) mix. |
| 18 | 12 mm cement plaster (1:6) mix |
| 19 | 15mm cement plaster (1:6) mix |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clestory windows including ISI marked pressed butt hinges bright finished of required size with necessary screws excluding panelling which will be paid separately, all completye as per directions of Engineer in charge 30mm thick second class Deodar wood |
| 21 | P/F pannelling or pannelling and glazed inpannelled or panneled and glazed shutters for doors windows and clestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Pannelling for panneled or panneled and glazed shutters 25mm to 40mm thick particle Board 12mm thick plain particle board flat pressed, 3 layer or Graded wood particle Board medium density grade I , IS 3087 marked |
| 22 | P/F glazed shutters for doors, windows and clestory windows using 10Kg/Sqm (4mm thick) float glass panes including ISI marked Mspressed butt hinges bright finished of required size with necessary screws. 30mm thick second class Kail wood |
| 23 | P/F wire gauze shutters using galvanised MS wire gauze ofaverage width for aperture 1.4mm in both directionswith wire of dia 0.63 mm dia for doors, windowsand clestory windows with ISI marked MS pressedbutt, hinges bright finished of required size with necessary screws as per direction of Engineer in charge 30mm second class kail wood |
| 24 | P/F ISI marked MS sliding door bolt with nuts and screws etc. Complete 250 x 16 mm |
| 25 | P/F ISI marked oxidised MS tower bolt black finish with necessary screws etc 150x10mm |
| 26 | P/F ISI marked oxidised MS tower bolt black finish with necessary screws etc complete 100x10 mm |
| 27 | P/F ISI marked oxidised Ms Handles confirming to IS:4992 with necessary screws complete 100 mm |
| 28 | P/F ISI marked oxidised Ms Handles confirming to IS:4992 with necessary screws etc complete 125 mm |
| 29 | Providing and Laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering, with (1:2:4) mix 20mm stone aggregate |
| 30 | Painting with synthetic enamal paint of approoved brand and manufacturer to give an even shade. Two or more coats on new work |
| 31 | Distemering with dry distemper of approoved brand and manufacturer (one or more coat) and of required shade on new work to give an even shade |
| 32 | Finishing walls with water proofing cement paint of required shade new work (two more coats) applied @ 3.84 kg/10sqm |
| 33 | Making plinth protection 50mm thich of cement concrete 1:3:6 over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 34 | Providing and fixing Electric points complete in all respects as per necessity of site |
| 35 | P/F on wall face un plasticized rigid PVC rain water pipes in the confirming to IS : 13592 type A including jointing with seal ring confirming to IS : 5382 leaving 100 mm gap for thermal expansion 110 mm diameter |
| 36 | P/F vitrified floor tile in different sizes (thickness to be specified by the manufacturer) with water absorptionless than 0.08% and confirming to IS:15622 of approoved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 including grouting the joints with white cementand matching pigments complete (500mmX500mm) |
| 37 | P/F 1st quality ceramic glazed wall tiles confirming to Is:15622 (thickness to be specified by the manufacturer) of approoved make, in allcolours, shades except burgundy, bottle green, blackof any size as aprooved by Engineer-in-charge, in skirting, risers of steps and dados over12mm thick bed of cement mortar 1:3 and jointing with grey cement [email protected] per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 38 | Filling available earth (excluding rock) in trenches, plinth, sides offoundations etc. In layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto50 mt and lift upto 1.5 mtr |
| 39 | Decorative painting which includes beautification of walls by way of asphalts, writing, pictures, slogans etc. |
| 40 | Carriage of material by mechanical transport (sand) 5 Km |
| 41 | Carriage of material by mechanical transport (Bajri) 5 Km |
| 42 | Carriage of material by mechanical transport (Bricks) 5 Km Please Enable Macros to View BoQ information |