Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-03-2026 |
| 2 | 13-02-2026 | Corrigendum No 01 | BOQ | 25-02-2026 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc n exc 10 sqm on plan and getting out in soft/loose soil. complete all as specified and directed. |
| 2 | Same as above item but exc 1.5m and n exc 3.0 m in depthfor foundation, complete all as specified and as directed. |
| 3 | M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete. |
| 4 | Use & waste of Flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work vertical of to batter, rough finished flat surfaces of concrete. |
| 5 | M&L for Reinforced cement concrete (DESIGN MIX M-25, using 20mm graded aggregate) as foundations, including rafts, footings foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete |
| 6 | M&L for Reinforced cement concrete (DESIGN MIX M-25, using 20mm graded aggregate) as Columns, pillars,piers, posts and struts |
| 7 | M&L RCC M-25 design mix (Using 20 mm graded stone aggregate) as in chajja all as specified and directed. |
| 8 | M&L for Reinforced cement concrete (DESIGN MIX M-25, using 20mm graded aggregate) as Beams, cantilivers, bressummers, lintels over 1.5m span |
| 9 | M&L for Reinforced cement concrete (DESIGN MIX M-25, using 20mm graded aggregate) as slabs supported on walls, beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and in shelves and the like |
| 10 | Use & waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) including fair finishof concrete surfaces. Complete all as specified and directed. |
| 11 | Use & waste of flat formwork to sides of pillars, posts, struts, piers, columns and stanchions, with fair finished surfaces all as directed |
| 12 | Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc, rough finished surfaces of concrete. |
| 13 | Use & waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges |
| 14 | S&FTMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less then 0.9 mm dia or securing with clips complete all as specified and directed. |
| 15 | S&F TMT 6mm to 8mm dia and over cut to length bent to shape required including cranking bending spirally and binding with and including mild steel wise (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge |
| 16 | M&L brickworkwith subclass \"B\" old size bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer -in- Charge. |
| 17 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and directed by Engineer -in- Charge. |
| 18 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface broken stone all as specified and directed |
| 19 | M&L sand for bedding layer 75 mm thick as per requirement over the broken stone or boulders layer complete all as directedand specified. |
| 20 | M & L for 150 micron polythene film for flooring all as specified and directed |
| 21 | M&L for 75mm thick cement concrete Type D2 ( 1:4:8) using 40mm graded stone aggregate as in subbase complete all as specified and as directed. |
| 22 | M&L for 30 mm thick Cement concretetype B-1,1:2:4 (20mm graded aggregate)as in sub base complete all as specified and directed. |
| 23 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed. |
| 24 | M&L Rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:4 for skirting/dado etc complete all as spd and directed |
| 25 | M&L for Coloured vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floorsset and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as spd and directed |
| 26 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 27 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match complete all as spd and directed |
| 28 | M&L for Machine cut kota stone slab flooring 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and Screed bed or bedding layer of mortar 15 mm thick (1:4) for laying floor finishes |
| 29 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed and Screed bed or bedding layer of mortar 15 mm thick (1:4) for laying floor finishes . |
| 30 | Material and labour for Plain Cement concrete 1:3:6 type C2 using 40mm aggregate as in foundations,filling and mass concrete complete all as specified and as directed. |
| 31 | Removing (soil) excavated materials n exc 50m and depositing where directed at a level n exc 1.5m above the sarting point |
| 32 | Returning, fillingin, including spreading, leveling, watering and well remming in layets not exc 25cm in soft/loose soil |
| 33 | M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:6 finished surface even and smooth without using extra cement. complete all as spd and directed |
| 34 | Material and labour for rendering 15mm thick cement plaster on in two layers each of 10+5mm thick in Cement Mortar (1:4) with WPC @2% wt of cement on fair faces of brick work completeallas specified and directed.(Note :Integral water proofing compound shall be measured and paid separately.) |
| 35 | Supply only integral water proofing compound confirming to IS 2645 – 2003. MAKE : SIKA/ ACCOPROOF/ CICCO NO-1 |
| 36 | Material and labour for 5 mm thick rendering in CM (1:3) on ceiling or concrete surface finished even and smooth without using extra cement, complete all as specified and directed |
| 37 | M&L for preparing new plastered surface for three coat of white wash all as specified and directed. |
| 38 | Materials and labour for preparing of New surfaces of wallsand applying two coat of oil emulsion paint (interior grade) on the same after complete removing the existing treatment and preparation of internal wall surfaces with minimum1mm thick oil putty and appying one coat of primer, all complete as specified and as directed. |
| 39 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and any pattern with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed ( Note :- Camouflage pattern shall be approved by Engr-in-Charge) |
| 40 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 41 | Supply and fix anodised aluminium window and ventilator shutters, sliding typewithout sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading,locking arrangement screws etc. complete all as specified and as directed. Make: HINDALCO/JINDAL |
| 42 | S&F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified |
| 43 | S&F5.50 mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane |
| 44 | S&F 4.00 mm sheet glass, ordinary quality, ground or obscured or frosted, on one side and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 45 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed and with stainless steel wire staples fixed complete all as specified. |
| 46 | M & L for 12 mm thick Prelaminated particle board, interior grade, prelaminated oneside with decorative choice lamination & other side balancing white lamination, fixed to aluminium framework all as specified and directed |
| 47 | S&F 100 mm sizeButt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified & directed. |
| 48 | S&F 200 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified & directed. |
| 49 | S&F 150 mm in size aluminium handles cast type anodized complete all as specified & directed. |
| 50 | S&F 100 mm in size aluminium handles cast type anodized complete all as specified & directed. |
| 51 | S&F mortice lock, brass, 4 levers type, size 100mm complete all as specified and as directed. |
| 52 | S&FAluminium Die cast body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed |
| 53 | S&F curtain rails,anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 54 | S&F mild steel framed work such as grills,gratings etc with ends of bars shouldered and / or riveted or forged into spiked, framed guard bars, iron doors, ladders, framed blasters, walkways, railings,framework of water tanks and similar work conforming to Fe 290 Grade E-165 |
| 55 | 15 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement complete all as specified and directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item ). |
| 56 | Water proofing treatment to RCC roof slab, includingparapet comprising with the following courses of treatment/specification from bottom to top :-(a) Applying bitumenous primer @ 0.25 ltrs per Sqmover plastered surfaces of roof including parapet surface.(Note :-Bituminuous primer shall be \"TANK MASTIC\" manufactured by \"EMUFALTE\" manufactured by M/s Texsa India Ltd./STP) (b)Over the priming coat laying one layer of APP based polymembric membrane of approved manufacturer, 3 mm thickweightnot less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a heightof 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying APP bassed polymenic membrane shall bedone withtorch application method or as per manufacturer\"s instructions.(ii)A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints with suitable adhesive as per manufacturer\"s instruction.(iii)APP bassed polymeric membrane shall be\"MOPLY FP 3MM\" manufactured by M/S Texsa India Limited/STP. (iv) Applying two coats of Aluminium paint over APP membrane. |
| 57 | M&L for ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 58 | M&L for ATT Treating the soil under plinth protection at the rate of 5 litres of emulsion per squaremetre of surface area |
| 59 | S&F 500 ltrs rotational moulded polyethelene water storage tank (Cylinderical vertical with closed top) incl connecting up pipes securing access coversetc as specified and as directed. (Make - Syntex/Polycon). |
| 60 | S & F 20mm dia brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fi, Complete all as specified and directed. |
| 61 | S & F 20mm gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed. Complete all as specified and directed. |
| 62 | S&F 15mm bore, medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceilings or laid in floors all as specified and directed. |
| 63 | S&F 20mm bore, medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceilings or laid in floors all as specified and directed. |
| 64 | S&F Vitreous China wash down water closet pan (pedestal pattern),whiteincluding trap, connection to drain (or out going pipe) and to flushing pipe, antisiphonage pipe, etc (excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 65 | S&F vitreous chinasquatting pan\"Orissa\" pattern size 580x440mm white with intgeral foot rests(excluding flushing cistern and flush pipe) with \"P\" or \"S\" trap fron or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one |
| 66 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 67 | S&F 10 Ltr capacity PVC Valveless symphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including bracket and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as per specified and directed. |
| 68 | S & F wash hand basin vitreous China, coloured including CI bracket 15mm dia polythene each connection, 32mm dia chromium plated(CP) waste coupling chain and plug waste filling union and 32mm bore LDPE pipe 90cm long of pressure rating 6 Kg/Sqcm fixed for waste pipe in WHB. Complete all as specified and directed. |
| 69 | S&F 15 mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed |
| 70 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed foriron pipe or for brass ferrule and fixed. |
| 71 | S & F for PVC Connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 72 | S&F Vitreous China Urinal, full stall type white with outlet for \"P\" trap, including 32mm bore LDPE pipe 90cm long of pressure rating 6 Kg/ Sqcm fixed for waste pipe in urinal. Complete all as specified and directed. |
| 73 | S & F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 74 | S&F 15 mm bore stop cock,(angle valve) cast copper alloy, fancy type, chromium plated, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 75 | S & F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) |
| 76 | S & FTubular towel rail, 20mm dia, D type, 600mm long between flanges chromium plated complete all as spd and directed |
| 77 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mmthick AC building board or commercial plywood and fixed to wooden plugs withchromium plated brass screws and cup washers |
| 78 | M & L for 75mm PVC (SWR) floor trap with grating including jointing with solvent cement. Complete all as specified and directed. |
| 79 | S&F 75mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 80 | S&F 75 mm PVC(SWR) bend any radius complete all as specified and directed |
| 81 | S&F 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints laidin trenches or in floors complete all as specified and directed. |
| 82 | S&F 110mm PVC(SWR) bend any radius complete all as specified and directed |
| 83 | M & L for point wiring with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi strandedCopper conductor cable of size 1.5 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall for light or Fan point controlled by one, one way switch 6/5 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch complete all as specified and directed |
| 84 | M&L for 3 pin 6 Amp socket outlet point wiring on independent board with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi stranded Copper conductor cable of size 1.5 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall controlled by one switch 6 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch socket complete all as specified and directed |
| 85 | M&L for 16 Amp socket outlet point wiring on independent board with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi stranded Copper conductor cable of size 4 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall controlled by one switch 16 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch socket complete all as specified and directed |
| 86 | Supply and fix modular Switchsingle pole, one way 5 Amp complete all as specified and directed. |
| 87 | Supply and fix modular Switchsingle pole, one way 15 Amp complete all as specified and directed. |
| 88 | M & L for concealed sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including heavy duty PVC conduitsize with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. Note: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. |
| 89 | M&L concealed sub main wiring usingtwo runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and includingPVC casing caping / canduit complete all as specified and directed. (For AC point and extra length for sockets points)Note :Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC casing capping/conduit shall be measured as one unit. |
| 90 | M&L concealed sub main wiring usingtwo runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in andincludingPVC casing caping / canduit complete all as specified and directed. (For TPN DB to SPN DB)Note :Two runs of 6.0 Sqmm copper wire,one run of 6.0 Sqmm wire & one run PVC casing capping/conduit shall be measured as one unit. |
| 91 | M&L concealed sub main wiring using four runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 10 Sqmm and one run of 10 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in andincludingPVC casing caping / canduit complete all as specified and directed. (For Panel to TPN DB)Note :Four runs of 10.0 Sqmm copper wire,one run of 10.0 Sqmm wire & one run PVC casing capping/conduit shall be measured as one unit. |
| 92 | Supply and fix modular Socket 5 Amps, 230 volts, complete all as specified and as directed. |
| 93 | Supply and fix modular socket, 16 amps, complete all as specified and directed. |
| 94 | Supply and fix modular fan regulator complete all as specified and directed. |
| 95 | S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. |
| 96 | S&F modular white cover plate with frame of 2 module complete all as specified and as directed. |
| 97 | S&F modular white cover plate with frame of 3 module complete all as specified and as directed. |
| 98 | S&F modular white cover plate with frame of 6 module complete all as specified and as directed. |
| 99 | S&F modular white cover plate with frame of 8 module complete all as specified and as directed. |
| 100 | S&F Metal flush box of 2 module complete all as specified and as directed. |
| 101 | S&F Metal flush box of 3 module complete all as specified and as directed. |
| 102 | S&F Metal flush box of 6 / 8 module complete all as specified and as directed. |
| 103 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 104 | Supply and fixing LED lights fitting 1x 10 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 105 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 106 | Supply and Fixing ofWaterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 107 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed. |
| 108 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep heavy duty with, blades, and framecompleteall as specified and directed. |
| 109 | Supply and fixing of sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) complete all as specified.Make: Havells / Anchor / Orient |
| 110 | S&F MCB DB CRCA sheet powder coatedTPN 4 way double door factory made suitable for incorporating MCB as out going and MCBs as incomingcomplete all as specified and as directed. |
| 111 | Supply and fix sheet metal enclosure MCB DB 8 waysingle pole with neutral for 240 V, fixed flushed on walls including necessary wall cuttingand making good disturbed surfaces and blanking plate as per requirementcomplete all as specified and directed |
| 112 | S&F MCB TPN, AC, 415 volts IP-43 of 40 to 63 Amps capacityand making connections incl taking down unsv one complete all as specified & directed. |
| 113 | S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 6-32 Amps, \"C\" series,10 KA breaking capacity, complete all as specified and directed |
| 114 | S&F MCB, SP, AC, 240 volts IP-43 of 05 to 32 Amps capacity \"C\" series and making connections incl taking down unsv one complete all as specified & directed. |
| 115 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating with ISEER as per latest Ministery of Power notificationdt 10 Nov 2023 of coolingcapacity 6000 K Cal per hour (2 TR ) including 3 meter coppar tubes duly ensuladed inlet outlet and power cable complete all as specified and directed. |
| 116 | Supply and fix 5.0 KVA wall/floor mounted type Electronic Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input variation between 120 V to 280V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% complete all as specified and as directed.Make: Bluestar / V Guard / Microtech |
| 117 | Copper tube (extra if required) for fixing of split Air conditioning of size 1/2 inch with insulating material all as specified and directed |
| 118 | Copper tube (extra if required) for fixing of split Air conditioning of size 1/4 inch with insulating material all as specified and directed |
| 119 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed. |
| 120 | Supply and spreading dry coarse sand in trenches as in sand cushioning for cable protection spread to uniform 23 cm thick and punch down gently to 18 cm after laying cable in trenches complete all as specified and directed. (Note: Compacted thickness shall be measured and paid) |
| 121 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all specified and directed. |
| 122 | Boring of holes under road, pavement, hard standing by manually and inserting GI pipe medium grade of dia 100 mmfor cable used in trench and inside boring for protection complete all as specified and directed. |
| 123 | S&F of GI pipe medium grade of dia 80 mmfor cable used as protection complete all as specified and directed. |
| 124 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.(Note : From Existing 25 KVA DG Set to Building Panel Change over) |
| 125 | M & L for supply,install testing and commissioning factory made of LT indoor panel cubicle type with bus bar chamber consisting of 4 nos of bus bar of capacity 100 Amps of aluminium bus bar 415 volts including digital multi function meter and Indicatinglamps LED type( R Y B) including wiring with suitable rated PVC insulated copper conductor etc. and panel board shall be made out of 3.15 mm thick CRCA steel sheet factory outlet including locking arrangements and mounted pedestal of 30cm height from ground level with suitable nuts,bolts and washers etc., detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables with glands and painting with two coats of super enamelled paint over a coat of metal primer all as specified and directed and panel shall be suitable to accomodate including the following items.(a) MCCB 4pole 125 Amps,50 Hz of breaking capacity36 KA - 01 No(Main Incoming)(b) Change over 63 Amp 415 V 4 pole (incomming from main and 25 KVA DG Set and outgoing to 63 Amps MCCB)(c) MCCB 4 pole 100 AMps,50Hz of breaking capacity 36 KA -01 No) (For Main outgoing to 4 way TPN DB )(c) MCCB 4 pole 63 AMps,50Hz of breaking capacity 36 KA - 01 Nos) (For DG supply outgoing through change over to 4 way TPN DB )(d) CT operated digital Multi function meter - 02 Nos (e) LED type Indicating lamp (set of 3 ) - 02 set(f) Necessary wiring including material including fixingMake: Havells / Indoasian / L&T |
| 126 | Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.Note: 04 Nos earthing (For DG Set) and 02 Nos for LT panel |
| 127 | Shifting of 25 KVA DG Set from old OTES to New OTES ater making Foundation of DG Set completion all asdirected.Note: Prepration of DG Set foundation as per required size and as per manufacturer specifiedanti vibration pads higring of mobile crane for shifting of DG set are inclusive of qoted rate. |
| 128 | Cutting ofDI mains 80 / 100 mm dia in position for insertion of new tees, tail pieces , sluice valve etc complete . |
| 129 | Supply and fixDI fittingfor spigotsocketed pipe , bends ( any type , radius and angle) tapers any type , (straight , bendincreasing , decreasingor doublesocketetc ) tee pieces single branch , Y junctiondouble branch , cross of size 100 / 80 mm dia |
| 130 | Material and Labour forGalvanized Iron water tubing \" Medium Grade\" of size 40 mm dia bore with all fittings laid in trenches / wall for following sizes. Complete all as specified and directed.Make - Jindal/Tata/Bansal/Utkarsh or equivalent |
| 131 | Material and Labour forGalvanized Iron water tubing \" Medium Grade\" of size 25 mm dia bore with all fittings laid in trenches / wall for following sizes. Complete all as specified and directed.Make - Jindal/Tata/Bansal/Utkarsh or equivalent |
| 132 | Supply and fixGun metal globe or gate valve of size 40 mm dia ISI markedhigh pressure with iron wheel headscrewed both ends for iron pipe line and fixedproperlyfor following sizes. Make - Zoloto/Kartar/Lakshmi/Venus or equivalent |
| 133 | Supply and fix Gun metal globe or gate valve of size 25 mm dia ISI markedhigh pressure with iron wheel headscrewed both ends for iron pipe line and fixedproperlyfor following sizes. Make - Zoloto/Kartar/Lakshmi/Venus or equivalent |
| 134 | M & L for construction of valve chamber of internal size 0.9 mtr x 0.9 mtr x 0.9 mtrwith 100 mm thick PCC(1:4:8 )type D-2for foundation, brickwallsbuilt in cementmortor(1:4 ) , PCC1:2:4 type B1for coping , rendering in cementmortor1:4 , 10 mm thick both internally and externally upto 10 cmbelowGL including provision of MS sheet coverusing angle iron 50 x 50 x 6 mm as a frame embeddedin concrete and 3 mm thick MS sheet as in cover with necessarylockingarrangements duly painted with two coats of syntheticenamel paint over a coat of red oxide primer and two coats of white wash after preparation of surafces including necessary earth workand excavationcomplete |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy