| 1 | Taking down cement plastering of brick or concrete wall surfaces racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 2 | Demolition of cement concrete (unreinforced ) in ground floors and paving n exc 15 cm thickness (below or above ground level) and removing the demolished material out of MOD land complete all as specified. |
| 3 | Demolition of cement concrete (unreinforced) exc 15 cm thickness in above ground floors and removing the demolished material out of MOD land complete all as specified. |
| 4 | Demolition of brick or stone masonry bilt in cement mortar including all necessary arches quoins etc. |
| 5 | Dismantling floor hearth or wall tiling including cement mortar bedding, removing the rubbish off the premises of MOD land complete all as specified. |
| 6 | M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaceand finished even and smooth without using extra cement complete. |
| 7 | M&L for rendering 5 mm thick cement plaster in CM 1:3 onceiling surfaces including finished even and smooth without using extra cement. |
| 8 | M&L for rendering 10 mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaceand finished even and smooth without using extra cement complete. |
| 9 | M&L for 25mm thick plain cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) in floors complete. |
| 10 | M&L for kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match thick shade of the slab including rubbing and polishing laid over 15mm thick screed bed in cm (1:4) complete all as spd. |
| 11 | All as per Item No 10.00 but on vertical surface of walls/skirting /dado etc complete all as specified and directed. |
| 12 | M&L for Glazed ceramic tiles in vertical surface 300X450X7mm thick set and jointed in neat cement slurry and jointed in neat cement slurry and pointed in white or coloured cement to match completeincluding 10 mm thick screed bed in cm 1:4 all as specified and directed. |
| 13 | M&L for non skid joint free coloured ceramictiles 7 to 8mm this area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and joint in neat cement slurry and point in coloured cement to match the shade of tile complete including 15 mm thick screed bed in cm 1:4 all as specified and directed. |
| 14 | Brick work with sub class \"B\" brick (old size) straight or curved on plan exc 6.0 m mean radius built in CM (1:6) Complete all as specified and directed. |
| 15 | All as per Item No 14.00 above but except brick. |
| 16 | M & L for two coats of oil boud distemper over a one coat of prime on 2mm thick wall care putty overr NEWLY plaster surface of wall includingpreparation of surfaces complete by mechanical means. |
| 17 | M & L for two coats of oil boud distemper on OLD Surface of wallincluding complete removal of existing treatment. |
| 18 | M & L for preparing New Surface of ceiling and applying three coats of white wash all as specified and directed. |
| 19 | M & L for preparingOLD surface of ceiling and applying two coats of white wash including complete removal of existing treatment all as specified and directed. |
| 20 | M & L for PreparingNEW surface of wall and applyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primeron walls (Externally) all as specified and directed. |
| 21 | M & L for preparing OLD surface of wall and applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine (Externally)including complete removal of existing treatment all as specified and directed. |
| 22 | Demolition of stone slabs and tiles of any description or thickness in floors, apron etc. |
| 23 | M & L for pressed precast rubber pressed glorry finished concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 grade laying in floors complete. |
| 24 | M&L for sand filling under floor in foundations inclding watering and consolidation complete. |
| 25 | M & L for 75 mm thick PCC 1:3:6 type C2 using 20mm graded stone aggregate as in sub base, floors and pavings etc. all as specified and directed. |
| 26 | M&LforPCC1:2:4 type B-1, (using12.5mm graded aggregate) as in coping ,including all necessary form work |
| 27 | Demolition ofbrick tiles or terracing tiles, single layer on roofsincluding cement screed complete all as specified and directed. |
| 28 | Demolition of cement concrete of any descriptionand in anypositionnot otherwise specifically provided for padding concrete upto existing RCC roof top complete all as specified and directed. |
| 29 | M&L for providing cement concretetype B-0 (1:2:4) using 12.5mm graded stone aggregate asin roof kerbs, padding or mud stops, rounded or chamfered on edges with water proofing compound @3% by weight of cement even and fair surface complete all as specified and directed.Note:- Liquid water proofing compound shall be measured and paid separately. |
| 30 | M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed. |
| 31 | M&L for rendering 10mm thick on fair faces of concrete surface in CM 1:6 with water proofing compound @3% by weight of cement even and fair surface complete all as specified and directed.Note:- Liquid water proofing compound shall be measured and paid separately. |
| 32 | M&L for water proofing treatment to RCC roof slab incl parapet as under (a) Applying bituminious primer conforming IS 3384 1965 @ 0.50 Kg/Sqm over cleaned and dry roof surface incl parapet.(b) APP based polymeric water proofing membrane minimum weighing 3Kg/ Sqm minimum 3 mm thick reinforced with polyster non-woven fabric (weight not less than 150 gms/Sqm) laid over primed roof surfaces by forced application and vertical surfaces up to grooves and width of overlap 75mm at the sides and 100mm in ends and applying solar reflective bituminous aluminium pain @ 100gm/sqm all as specified and as directed. |
| 33 | Supply only Liquid water proofing compound |
| 34 | S & F in repair Steel rolling shutters with out ball bearing , as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position as indicated complete but gear operated type with chain wheel and hand chain ( including Bracket plate , U- Clamp , Hood cover , Stopper , Guide Channel , Curtain Lath, Locking Arrangment Concealed Suspension Shaft Rotate shutter etc) Complete all as specified and directed. |
| 35 | S & F for Safety lever locks mild steel with 4 levers for rolling shutters |
| 36 | M & L for Ball bearing for rolling shutters |
| 37 | S & F in repair Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing barsdovetailed or welded including friction hinges are provided in lieu of projecting hinges and peg stay and double leaf doors include for concealed bolts. |
| 38 | M & L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with steel bead/ glazing pins in squares n. Exc 0.5 Sqm in each pane all as specifed and directed. |
| 39 | Hacking out old broken glass (any thickness, size, quality or decription) from wooden or steel frames glazed with putty or fixed with beads. |
| 40 | M & L for Preparation of NEW Steel surface of any description over10 CM width or girth by applying sand paper etc for proper preparation and applying Two coat of synthetic enamel paint over red oxide zinc primer to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. |
| 41 | M & L for Preparation of OLD Steel surface of any description over10 CM width or girth by applying sand paper etc for proper preparation and applying Two coat of synthetic enamel paint to given an even and smooth surfacehaving no sign of brush marks all as specified and directed complete all as specified and directed. |
| 42 | Dismantling water storage tanks of any description/ exc 1000 liters capacity andn exc 2000 ltr capacity removing from site complete all as specified. |
| 43 | S&F for Rotational moulded polythylene 2000 liters capacity waterstorage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 25 mm ball valve high pressure of PTMT with epoxy coated alu rod & high density plastic balland tank nipplecomplete all asspecified |
| 44 | Repairing to existing door/ window chajjas, inverted faciaor roof slab or visible concrete reinforcementof any thickness, roof slab bottom upto 3.0m span and width 1.0m, iby demolition/ scrapping of damaged portion and preparing the surfaces by providing50mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregateincluding finishing the surface by rendering 10 mm thick plaster in cement mortar 1:3 and finished even and smooth surface using extra cement over concrete surface and PCC benching including weathering sliglitely rounded or chamfered angles and throating over and including priming newly plastered/concrete surface by applying one coat of primer, 2 mm thick acrylic damp proof wall care putty and applying two coat of Apex paint (Weather coat exterior paint) and complete making good existing disturbed surface all as specified and directed |
| 45 | M & L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base, floors and pavings etc all as specified and directed. |
| 46 | M & L for Cement concrete work pavement / hard- standing offlexural strength 40 kg /per sq cm in field using 400 kg of cement per cum complete all as specified and as directed by Engr-in-Charge. |
| 47 | M & L for providing 75mm thick cement concrete 1:3:6 type C-2 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays ( n exc 2 sqm each) and finishhed even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weightcomplete all as specified.. |
| 48 | Dismantling posts or struts (wood , steel or R.C.C ) any section, including taking outembedded portion and making good disturbed groud all as specified and directed. |
| 49 | Dismantling fencing wire mesh, any type all as specified and directed. |
| 50 | Excavation in Post holeseach , not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm , watering, and removing surplus soil to a dist n. exc 50 m and making good surface.in any type of soil. |
| 51 | Hand rails, half round or other steel section or Hollow section (confirming to IS 2062:2011), drilled and countersunk for balusters running bars, for doors, balusters,nosingtosteps includingembeddinginconcrete and screwing etc. wind ties for roofincluding securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 52 | S&F for mild steel screw bolts (machine made) with hexagonal or square head and one end screwed or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut, exc. 10 cm but not exc. 15 cm long of 11 to 15 mm dia of shank. |
| 53 | S&F for Cement concrete 1:3:6 type C-2 using 20mm graded crushed stone aggregates in foundations, filling and mass concrete. |
| 54 | M & L for prepatation of new steel surfaces and apply two coats of synthetic enamel paint over a coat of red oxide primer n exc 10cm width or girth. |
| 55 | Supply only MS Galvanized chain link fencing of size 75mm 75mm square/any sizemesh of 10 gauge type all as directed by Engr-in-Charge. |
| 56 | Fixing only chain link fencing including line wires,any mesh , size and type of standards, rails straining bolts etc. Complete including provision of binding wire all as directed by the Engr-in-Charge. |
| 57 | M & L galvanized , 2 strand , steel barbed wire,2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanized MS wire staples or steel pins etc as specified (each line wire to be measured). |
| 58 | Taking up or down steel tubing and connections 20mm bore of pipe complete all as specified and directed. |
| 59 | S&F for20mm bore CPVC pipe SDR-11 , plain SDR-11 Fittings complete to wall and celing or laid floors or concealed & joiny only with CPVC solvent cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc Male threaded adaptor, Female threadedadaptor ,End cap, End Plugs ,Unions,Flange etc) , complete all as specified and directed |
| 60 | S&F in repair PVC valveless 10 liter capacity syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed by Engr-in -Charge. |
| 61 | S&F in repair CP Bib taps 15mm bore fancy type CP Bib taps single way/two way cast copper alloy with crutch or butterfly nuts, handle,screwed down for cpvc pipe. |
| 62 | S&FFor 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed but fancy type for CPVCpipe and fixed as specifed and as directed. |
| 63 | S&F in repaired Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc.(excluding flushing cistern & flush pipe) complete in all respect all as specified |
| 64 | S & F in repairs vitreous china wash hand basin, white flat back, size 550x400mm with brackets including cutting for and pinning in ends of brackets or erecting stand and 32mm dia flush pipe complete all as specified and directed. |
| 65 | M & L for PCC 1:4:8 type D2 ( using 40mm graded granite stone aggregate ) in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 150mm bore. |
| 66 | M & L for 150mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified. |
| 67 | M & L for Concrete bed to drain pipes of 150mm including packing under,and aunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2 all as specified and directed. |
| 68 | M & L for Cement concrete 1:2:4 type B-2 using 20mm graded crushed stone aggregates in foundations, filling and mas concrete and providing chequered finish on top for ramp etc. |
| 69 | S & F in repair 110mm PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed on walls/floor (including Elbow,Tee, Socket, Reducer, Bushin, Stepover bends, End cap, End Plug etc) |
| 70 | Taking down Chowkhats or frames exc 1.5 sqm but n.exc 4 sqm with shutters (Without taking off shutters from the frame) |
| 71 | S&F Solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 72 | S&F Factory made solid panel PVC door shutter30 mm thick (style)consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C\"channel having a PVCsheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, andS&F in the frame at site as per specification and drawing. |
| 73 | S&F150mm long aluminium anodised barrel tower bolt of extruded section and fixed to PVC door complete. |
| 74 | S&F250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 75 | S&F150mm long aluminium anodised handles, extruded aluminium alloy fabricated type and fixed to PVC door complete |
| 76 | S&F butt hinges extruded aluminium alloy with galvanised mild steel hing pinanodised and fixed type 100mm size C21 |
| 77 | S&F mild steel flat iron as in hold fast clamps articles conforming to FE 290 Gde 165 |
| 78 | Supply & fix in repair Sign board made out of 3.00 mm thick aluminium composite panel size 900mmx600mm covered with green colour retro reflective sheet on one side of panel in main portion including writing letters and arrow as per direction with white reflective tap all as directed and shown in ground. |
| 79 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 80 | Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete andall as directed by Engr in charge |
| 81 | Material and labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 voltsgrade confirming to IS-694 drawn through and including non metallic rigid PVC heavy duty concled conduit minium 20 mm dia,but shall be increased as per actual site requirement in accordance with clause No.19.125 of SSR Part-I ,with necessary accessories with Flush mounting boxes& white plates with frames housing of switches sockets / fan regulator etc. including 1.5 Sqmm single core solid multitranded copper conductor FRLSH 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge for;-(Note :- The cost of Mudular mounting boxes and modular plates included in the quoted rates)Make :(i)Flush mounting boxes- Legrand/ Havells/SIEMENS.(ii)White Plates : upto 18 module Legrand/ Havells / Siemens / Crabtree |
| 82 | One light point controlled by one, one way switch single pole. |
| 83 | One fan point controlled by one, one way switch single pole. |
| 84 | One exhaust fan point controlled by one, one way switch single pole. |
| 85 | One 3 pin 5 Amps socket outlet on independent board |
| 86 | One 3 pin 5 Amps socket outlet on Same board |
| 87 | All as per srl item No 81.00 but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board. |
| 88 | S&F 6 A one-way SP switch - 1 module of Make Legard Cat No: 6755 01 or equivalent in Simens / Carbtreeall as specified and directed. |
| 89 | S&F modular socket outlet multipurpose 2/3 pin, 6 Amps, 240 volts (with 2 pin 5 Amps outlet also) flush type (shuttered) complete all as specified/directed. |
| 90 | S&F 16 A one-way SP switch - 1 module of Make Legard Cat No: 6755 11 or equivalent in Simens / Carbtreeall as specified and directed. |
| 91 | S&F modular socket 2/3 pin, 16 Amps and (with 2/3 pin 6 Amps outlet also) complete all as specified and directed. |
| 92 | S & F Fan regulator 100 W with 360° rotation 2 moduleof Make Legard Cat No: 6759 64 or equvalent in Simens /Carbtreeall as specified and directed. |
| 93 | S&F ceiling rose surface bakelite three terminal all as specified and directed. |
| 94 | S & F in replacement double doorSheet metal enclosures factory made DBs4 way, 240 volts, protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 95 | S & F in replacement double doorSheet metal enclosures factory made DBs8 way, 240 volts, protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 96 | S & F MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) for the following :- |
| 97 | MCB Single Poleof 240 volts 5-32 Amps,10 KA Capacity, \"B\" series |
| 98 | MCB Single pole + Neutral 240 volts, 32 Amps,10 KA Capacity, \"C\" series |
| 99 | Supply and fix and replacement LED batten luminaire surface mounted ,4 feet system wattage of not less than 18 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixedcompleteallas specified and directed. |
| 100 | M&L in replacementfor sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through PVC Casing Caping /conduit and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note : Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 101 | M&L in replacementfor sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 10 Sqmm single core, copper conductor drawn through PVC Casing Caping /conduit and 10 Sqmm single core multistranded copper conductor FRLSHPVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note : Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 102 | Supply and fix in replacement industrial type switch socket for Geysers with 20 Amps MCB Make:- Iengard Cat No.6078 41 20 A SP complete or Equalliant in L & T /Hager |
| 103 | M & L for Earthing complete with galvanized steel earth plate electrode 60x60cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead wire 4.0 mm dia,by means of nuts,bolts,checknuts and washers of galvanized iron including 15 mm bore GI pipe,medium grade up to 7.5 meters long all as shown in electrical plate No.3 of MES SSR part-I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber,precast RCC slab 50mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric ,( weight not less than 4 Kg/Sqm), with cast iron frame, funnel with wire mesh,GI watering pipi 20 mm dia medium grade,test point and lugs complete.NOTE:-(i) Items includes the cost of 7.5 metre length GI pipe and earth lead for protection of earth lead.Any variation in length shall be adjusted through deviation order.(ii) On testing,if the earth resistance is not obtained,earthing will be regenerated at no extra cost till the desired earth resistance is obtained. |
| 104 | S & F Earth continuity conductor or main earthing lead/stripfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25 x 4mm dia galvanised iron or steel wire |
| 105 | Taking down existing light fitting andS&F LED bldg security light fitting 30 watt, 230v AC outdoor type with high pressure die cast aluminium hosing and heat resistance complete with driver, lamp bracket with impact and corrosion resistant including thermal management in miltiple optics, complete with IP 65/66 protection complete. |
| 106 | Taking down exhaust fan, sealing cable end, dismantling blades and removing materials to MES store yard for keeping in safe custody for further reuse in maint work |
| 107 | Refixing ofexhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers heavy duty complete after nessesary servicing and painting etcall as specified and directed |
| 108 | Refixing ofexhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete after nessesary servicing and painting etc all as specified and directed |