| 1 | Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed. |
| 2 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 3 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 4 | M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 5 | M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 7 | M&L for preparing newly plastered surfaces and applying applying two coats of distemper oil emulsion by rollerwhite or tinted over and including one coat of 1mm thick wall care putty complete all as specified and directed. Make - Berger / Nerolac / Assian ortechno commercially equivalent makes specified in PS. |
| 8 | M & L for newly plastered surface of wall/ ceiling/ chajja and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat ofprimer applied @ 0.90 litre/ 10 Sqm complete all as specified and directed. Note :- Premium acrylic emulsion paint should be done as per following processer :-(i) Preparation of newly plasterd surface of wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etccomplete and applying 2mm thick wall care putty on scrabed surface. (ii) After that and applying one coats ofAnti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of approved primer as per manufacturers instructions weather proof primer with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer\"s instructions and all coats including primer to be applied with fully automatic airless spray machineof paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI or manual application. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.(iii) MAKE :- dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 10 orTechno commercially equivalent makes specified in PS. |
| 9 | M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 10 | M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 11 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 12 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 13 | S & F mild steel screw bolts (machine made), diameter of neck 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 22.5 cm but not exceeding 30 cm long complete all as specified and as directed. |
| 14 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 15 | M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 17 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 18 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and as directed. |
| 19 | S & F ERW or HFIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade), made of hot-rolled carbon steel strip conforming to IS 10748: 2004 (grade 3, yield steel 240 Mpa) as in tubular trusses including special shaped washer etc. complete all as specified and as directed. |
| 20 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 21 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category C3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self drilling screws and washers including side and end lap, necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 22 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated (profile) steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category C3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall claddingfixed with self drilling screws and washers as specified including end and side lap, necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 23 | S & F 2 mm thick glass fibre reinforced translucent plastics sheeting of any profile, diffusion classification I with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed. |
| 24 | M & L welded steel wire fabric complete to wood or steel members weight not exceeding 4.00 kg /sqm complete all as specified and as directed. |
| 25 | S&F for 600mm dia heavy duty wind driven 600mm throat diameter stainless steel turbo weatherproof roof vebtilator with base plate and stand, equipped with permanently lubricated including twin sealed ballbearings of appropriate size for frictionless, silent rotation even at low wind speeds, base plate matching with roof shhet, leak proof and weatherproof using silicone sealants and SS self drilling screws with washers etc complete all as specified |
| 26 | M & L for powder coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 27 | M & L for powder coated aluminium door shutters, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium snap beading screws etc. complete all as specified and as directed. |
| 28 | Supply & fix toughened (tempered) safety glass as per IS 2553 (Part-1): 2018, flat, tinted 5 mm thick, fixed with steel, aluminium, metal frame work including rubber beading complete all as specified and as directed. |
| 29 | M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 30 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 31 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 32 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and smooth using extra cement complete all as specified and as directed. |
| 33 | M & L for preparation of new or previously treated surface and painting lines, dashes, arrows, letters, etc. on roads, pavements and the like not exceeding 10 cm wide with road marking paint, white or golden yellow complete all as specified and as directed. |
| 34 | S&F for (moveable type) badminton court pole of 50mm pipe MS pipe including height adjustable, adjustable winch, wide stable base and anti-slip design etc of approved size, length and make as approved by accepting officer complete all as specified and directed |
| 35 | M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. |
| 36 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. |
| 37 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. |
| 38 | M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 39 | S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 40 | S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 41 | S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 42 | S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 43 | S & F flood lights nominal 120 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) lessthan 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 44 | M & L for bracket made out of GI pipe 32 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts complete all as specified and as directed. |
| 45 | S & F flood lights nominal 70 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) lessthan 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 46 | S & F LED streetlight/ building security light nominal power 35 Watt, 230 V AC, outdoor type with aluminium pressure die-cast housing, polyester powder coated, IP 65/66 protection complete with in-built integrated electronic LED driver including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 47 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS. |
| 48 | S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 49 | S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 50 | S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers and all fixing accessories including making hole for fixing of exhaust fan of suitable size and making good the disturbed surface as per existing complete all as specified and directed. |
| 51 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 52 | Supply and laying flexible DWC HDPE pipe ISI UV resistant in trenches under floor, wall etc 32 mm inner dia and 40mm outer dia for the protection of XLPE cable from nearest LT panel to DB, incl MS clamp complete all as specified and directed. |