Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge. |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 4 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm eachcomplete all as specified and as directed by Engineer-in-charge. (Note for item No. 4.00 & 5.00- Rate shall be deemed to be include for cuttingholes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces). |
| 6 | Taking down ofshutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed. |
| 7 | Taking down ofshutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm eachand refixing shutters of any description in same opeining after easing etc., complete all as per specified and as directed by Engineer-in-charge. |
| 8 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridge complete all as per specified and as directed by Engineer-in-charge. |
| 9 | Dismantling ballies, hard or soft wood, any position, except in posts and struts; including taking out iron straps, bolts and nuts, etc.,if anycomplete all as per specified and as directed by Engineer-in-charge. |
| 10 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exceeding 500 m and not exc.900 m including roughening of old concrete surface of roofby wire brushing and cleaning the surface to remove all loose dust etc, complete all as specified and as directed by Engineer-in-charge. |
| 11 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge. |
| 14 | Dismantling water tanks of capacity exc. 250 and not exc. 500 litres, complete all as per specified and as directed by Engineer-in-charge. |
| 15 | Taking up or down of 15 mm steel tubing and connections, including cleaning , complete all as per specified and as directed by Engineer-in-charge. |
| 16 | Taking up or down 20 mm steel tubing and connections, including cleaningcomplete all as per specified and as directed by Engineer-in-charge. |
| 17 | Taking up or down 25 mm steel tubing and connections, including cleaning complete all as per specified and as directed by Engineer-in-charge. |
| 18 | M&L for PCC 1:3:6 Type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 19 | M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in in copping, bed plates etc of main holes, roof kerbs or mud stops, rounded or chamfered on edges include necessary formwork (straight or curved), complete all as specified and as directed by Engineer-in-charge. |
| 20 | M & L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge. |
| 21 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed by Engineer-in-charge. |
| 22 | M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves andlike etc complete all as specified and directed. |
| 23 | Supply only Liquid water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge. |
| 24 | M&L for brick work with fly ash bricks straight or curved on plan in CM 1:4 as in half brick thick walls, complete all as specified and as directed by Engineer-in-charge. |
| 25 | M&L for fly ash brick work with bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. |
| 26 | S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 27 | S&F Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 28 | S&F 35mm flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side, one face is covered with decorative face veneer with lipping/frame to matchetc complete all as specified and directed by Engineer-in-charge. . |
| 29 | S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge. |
| 30 | M&L 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered orrounded fitted with cut and mitred beads for securingglass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide)as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed by Engineer-in-charge. |
| 31 | S & F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge. |
| 32 | S&F of floor door stopper 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge. |
| 33 | S&F 100 mm butt hinges stainless steel, complete all as per specified and as directed by Engineer-in-charge. |
| 34 | S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 35 | S&F of 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as per specified and as directed by Engineer-in-charge. |
| 36 | S&F of 250 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 37 | S&F of MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge. |
| 38 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 40 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified and as directed by Engineer-in-charge.Note: (a) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.(b) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 39 | Supply and fixing of factory made solid panel factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face , supplying & fixing in frame at site as per specification & drawing complete all as per specified and as directed by Engineer-in-charge. |
| 40 | S&F in repairs of harrison rails curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge. |
| 41 | M&L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforce with 19mm x 19mm MS square tube of 19 gaugethickness throughout the frame and metre cut at two cornersand jointed with 2 nos of 150mm long brackets of 15mm x 15mm MS square tubes.The door frame shall be fixed to the wall using 100mm long MS screws through the frame by using PVC fasteners. A minimum 4 nos of screws to be provided for each vertical member and minimum 2 nos of screws to be provided to the horizontal member etc., complete all as per specified and as directed by Engineer-in-charge. |
| 42 | M & L for providing & fixing factory made solid PVC cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600kg/cbm outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cbm manufactured byan ISO 9001-2015 certfied company. Door should be water proof, turmite proof, fire retardantand having good screw holding capacity, complete all as per specified and as directed by Engineer-in-charge. |
| 43 | S&F of providing and fixing factory made PVC shelf/ partition of required size consisting of20mm thick Solid PVC Sandwich Panel with 1mm Plain PVC Sheet on both sides suitably fixed in M.S. angle frame work as per specification & drawing, complete all as per specified and as directed by Engineer-in-charge. |
| 44 | S&F of 75 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as per specified and as directed by Engineer-in-charge. |
| 45 | S&F of 75 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 46 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) including edges fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 48 | S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, complete all as per specified and as directed by Engineer-in-charge. |
| 49 | S&F framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 Gde-E-165, complete all as per specified and as directed by Engineer-in-charge. |
| 50 | S&F of Powder coatedaluminium window sliding type three track (2 glazed & one gauzed shutter ) aluminium sections weighing not less than 1.25kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge. |
| 51 | S&F of Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazingcleats, rubber packing , anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangementsincluding taking down of old existing steel ventilator and making good disturbed surfacesof wall complete all as per specified and as directed by Engineer-in-charge. |
| 52 | S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge. |
| 53 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ footpath/ steps finished cement concrete surface even & fair etc including necessary form work complete all as specified and as directed by Engineer-in-charge. |
| 54 | M&L for 75mm thick PCC 1:4:8, type D2 (using 40mm graded agg) as in sub base, complete all as per specified and as directed by Engineer-in-charge. |
| 55 | Providing and laying of 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed by Engineer-in-charge. |
| 56 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as per specified and as directed by Engineer-in-charge. |
| 57 | Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm, complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge. |
| 59 | S&F of coloured non-skid ceramic tiles 8 to 10mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge. |
| 60 | Ditto-all as per Item No.59.00 here-in-before but in skirting/dado, etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match with the shades of tilescomplete all as specified and directed. |
| 61 | M&L for 10mm thick rendering on skirting/ dado or vertical surfacesin cm(1:4) on fair faces of brick work or concrete surfaces, complete all as specified and as directed by Engineer-in-charge. |
| 62 | M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to stepsetc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over, complete all as specified and as directed by Engineer-in-charge. |
| 63 | M&L for Machine cut Kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 64 | M&L for machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge. |
| 65 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigmint to match the shade of granite stone including griding & polishing with 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 66 | All as per serial item No. 65 here-in-before but as in skirting laid over and including 10 mm thick rendering/ back coating in CM (1:3) complete all as specified and as directed by Engineer-in-charge. |
| 67 | Providing holes to cooking platform of size 25 mm dia for inserting cooking gas pipe in suitable place as directed by Engr-in charge |
| 68 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor finished cement concrete surface even & fair etc including necessary form work complete all as specified and as directed by Engineer-in-charge. |
| 69 | M & for water proofing treatment to sunken floor with the following course of treatment/ specification:(i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer\"s instruction laid in slope 1:20 towards spouts including coveting corners(ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturer\"s instruction.(iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs.(iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces(vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation.(vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drainout accumulated water.(viii)Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists(ix) Sunken portion shall be filled with lean concrete 1:4:8 type D2. |
| 70 | M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC @200ml per 50 Kg of cementin order to maintain proper slope over existing roof surfaces for laying water proofing treatment over roof, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.(Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule as \"Supply Only\"). |
| 71 | M&L for water-proofing treatment to RCC roof slab including parapet, comprising the following course of treatment (applied from bottom to top):(a) Applying bituminous primer @ 0.40 litre per Sqm over prepared plastered surfaces of the roof including parapet surfaces.(b) Over the priming coat, laying one layer of APP-based polymeric membrane, 3 mm thick, weighing not less than 3.0 Kg/Sqm, reinforced with non-woven polyester fabric weighing not less than 160 gsm. The membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of the parapet.(c) Applying two coats of bituminous aluminium paint over the polymeric membrane after necessary preparation and cleaning.The laying of APP-based polymeric membrane shall be done by torch-on method or as per manufacturer’s instructions.Notes:(i) A minimum overlap of 100 mm shall be provided at the ends and 75 mm at the sides of the APP-based polymeric membrane and sealed as per manufacturer’s instructions.(ii) APP-based polymeric membrane shall be of approved quality conforming to the required specifications.(iii) Cutting grooves in brick wall 75mm wide and 65mm deep and sloping horizontal face of groove with cement mortar 1:3(iv) The work to be executed through authorised applicator. |
| 72 | M&L for rendering 15 mm thick on fair face of brick worksor concretesurfaces of wallswith cement mortar (1:4) in two coats (10mm thick backing coat + 5mm thick plaster) mixed with WPC @200ml per 50 Kg of cement on 5mm thick plaster, finished the surfaces even and smoothwithout using extra cement complete all as specified anddirected. (Note : WPC will be measured and paid separately) |
| 73 | M&L rendering 15 mm thick on other than fair faces of brick work or concrete block surface in cement mortar 1:6,surface to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge. |
| 74 | M&L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed. |
| 75 | M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge. |
| 76 | M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge. |
| 77 | M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge. |
| 78 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty newly plastered surfaces of wall after and including preparation of surfaces complete all as specified and directed. |
| 79 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decoratedplastered surface of wall after and including complete removal of existing treatment andpreparation of surfaces complete all as specified and directed. |
| 80 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 81 | M&L for preparing old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 82 | M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved grade complete all as specified andas directed. |
| 83 | M&L for complete removal of existing wall surfaces and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved gradeover old surfaces complete all as specified and directed. |
| 84 | S&F of rotational moulded polyethylene water storage tanks multi layer, (three layer)ISI Marked (cylindrical, vertical with closed top) of 500 Litres capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed by Engineer-in-charge. |
| 85 | S&F in repairsof 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 86 | S&F in repairsof 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 87 | Cutting of existing GI pipe for addition or alteration of 40/50mm dia bore for inserting of reducer Tee complete all as per specified and as directed by Engineer-in-charge. |
| 88 | S&F in repair of 20 mm ballvalves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge. |
| 89 | M&L for GI water tubing medium grade 15 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors , complete all as specified and as directed by Engineer-in-Charge. |
| 90 | Taking up or down steel tubing and connections, including cleaning and refixing of oldsurviceable 15 mm GI tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by Engineer-in-charge. |
| 91 | S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type)complete all as specified and directed. |
| 92 | Taking up or down steel tubing and connections, including cleaning and refixing of oldsurviceable 20 mm GI tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by Engineer-in-charge. |
| 93 | S&F of 25mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type)complete all as specified and directed. |
| 94 | Supply and fixed in repairs sinks without drainage board made of stainless steel 1mm thick sheet plugs, washers and waste pipe, including a pair of cantilever brackets embedded in wall with suitable size of PCC (1:3:6) type C-1 blocks and connecting union to pipe of overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all complete as specified and as directed. |
| 95 | S&F in repair of Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size(flat back or angle back type) including cutting for and pinning ends of brackets and including, waste pipe, CP waste coupling, PVC connection 15mm dia with PTMT nuts of length 450mm etc., complete all as per specified and as directed by Engineer-in-charge. |
| 96 | S&F in repair of 32 mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 97 | S&F in repairs of Brass CP mixer of 15mm diafor mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and as directed by Engineer-in-charge. |
| 98 | S&F in repair of bevelled edge mirror 600mm x 450mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-charge. |
| 99 | S&F in repair of PVC valveless, syphonic action type 10 ltr capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge. |
| 100 | S&Fin repairs of vitreous china wash down water closet pan (pedestal pattern) white with \"P\" or \"S\" trap type(excluding flushing cistern & flush pipe)including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipeout inwith and including including making good to floor complete all as specified anddirected. |
| 101 | S&F in repairs of vitreous china squatting pan \"Orissa\" pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floorcompleteall as specified and directed. |
| 102 | S & Fplastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as per specified and as directed by Engineer-in-charge. |
| 103 | S&F in repair of Bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge. |
| 104 | S&Fin repairs of 15 mm borestop valve,fancy type, chromium plated ,with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionscomplete all as specified and directed. |
| 105 | S&F in repair of 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge. |
| 106 | S&Fin repairs of 15mm dia pillar tap, fancy tpype, cast copper alloy with capstan heads, chromium plated,screweddown high pressure, with letter \"HOT\" or \"COLD\" with long screwed shanks & fly nuts, screwed for iron pipes completeall as specified anddirected. |
| 107 | S&F in repair of two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron pipe 15 mm bore and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 108 | S&F in repairs of 15mm dia, angle/stop valve, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 109 | S&F in repair of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as per specified and as directed by Engineer-in-charge. |
| 110 | S&F in repair of brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as per specified and as directed by Engineer-in-charge. |
| 111 | S&F glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chomium plated bracket guard & railing 60 cm long, complete all as per specified and as directed by Engineer-in-charge. |
| 112 | S & F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm, complete all as per specified and as directed by Engineer-in-charge. |
| 113 | S&F in repair of CPtowel Ring of minimum dia 200mm fixed with and including Chromium plated brass screws and wooden/plastic cleatscomplete all as per specified and as directed by Engineer-in-charge. |
| 114 | S&F in repair of 1.00 mm thick stainless steel plate rack of size 787.40 x 762.00 x 254.00 mm, complete all as per specified and as directed by Engineer-in-charge. |
| 115 | S&F in repair of Brass chromium plated shower rose 125mm size, complete all as per specified and as directed by Engineer-in-charge. |
| 116 | S&F in repairs of floor trap of 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge. |
| 117 | S&F of 40 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc, complete all as per specified and as directed by Engineer-in-charge. |
| 118 | M&L for salt-glazed stoneware gully traps, square or round mouthed, type `P\" 150x100mm complete all as directed by Engr-in-Charge |
| 119 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joint fixed on wallcomplete all as per specified and as directed by Engineer-in-charge. |
| 120 | S&F of PVC (SWR) 110 mm bore bends with access door complete all as per specified and as directed by Engineer-in-charge. |
| 121 | S&F of 110mm dia PVC (SWR) branch piece single (single \"Y\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 122 | S&F of 110mm dia PVC SWR vent cowl complete all as per specified and as directed by Engineer-in-charge. |
| 123 | S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 124 | S&F of PVC (SWR) 75 mm bore bends complete all as per specified and as directed by Engineer-in-charge. |
| 125 | S&F of 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 126 | S & F 75 mm bore PVC (SWR) branch piece single (Single `Y\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 127 | Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power)complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed. |
| 128 | M&Lfor point wiringcomplete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. flush mountingMS box with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing ofmodular top cover , blankingplate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresmodular accessories of suitable modules andincluding 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathedsingle core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surfacecomplete all as specified and directedfor the following:- (Note:- (i) Allnecessary accessories such asmodular box, top cover plate, blank plate, MS box, screws, washers etcare deemed to be included with quoted rate and to be used of same make/brand onlyin relevant items.(ii) Cutting & chasingof wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.) |
| 129 | (a) One light point controlled by one switch . |
| 130 | (b) One fan/exhaust fan point controlled by one switch. |
| 131 | © One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on independent board . |
| 132 | (d) One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on same board . |
| 133 | (e) One bell point controlled by one switch 5/6 amps . |
| 134 | (f) One light point controlled by two way switch 5/6 amps. |
| 135 | All as per Item No.128.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmmfor one socket outlet 15/16 amps point on independent board complete all as specified and directed. |
| 136 | S&F of modularswitch 10 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed. |
| 137 | S&F of modularswitch 10 Amps, single pole, 2 way, 1 module, 240V, AC, complete all as specified and directed. |
| 138 | S&F of modularswitch 16 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed. |
| 139 | S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC,complete all as specified and directed. |
| 140 | S&F of modularsocket6/16 Amps, 6 pin combined shutter socket, 2module with light indication, 240 V, AC, complete all as specified and directed. |
| 141 | S&F of modular bell push one way 10 amps, single pole 240 volts, AC, suitable for 1 module completeall as specified and directed. |
| 142 | S&F of call bell multi-music 240 volts, AC,completeall as specified and directed. |
| 143 | S&F oflamp holder, insulated body with back plate for batten fittingsincluding 9 watts LED lamp complete all asspecified and directed. |
| 144 | S&F of modular fan regulator,electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed. |
| 145 | S&F ofceiling rose , three terminal, PVC/polycarbonate body, ISI marked completeall as specified and directed. |
| 146 | S&F of decorative typesurface mounted 1X20 watts LED light fitting with LED lamps 4 feet, 5700K including fixing arrangements at any heightwith nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of requiredsize with integrated high efficiency el;ectric driver and surge suppressor of 2KV or more lumen efficiency > 120lumens/watt, power factor >0.90, operating range 140 to 270 V, 50Hz complete all as specified and directed. |
| 147 | S&F of inverter LED batten 1X20 watts with squre profile and polycarbonate channel lithium lon battery with charging time 8 hours-10 hours and back up time upto 4 hours with driver, holder including LED tube including fixing arrangements at any heightwith nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of requiredsize complete all as specified and directed. |
| 148 | Fixing only LED tube light 12 to 20 watts on wall/ surface mounted with 2 Nos. PVC round/ square blocks, screws complete all as specified and as directed. |
| 149 | S&F of10 watt LED light fitting mirror type with high out put diffuser 2 feet,220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size and other fixing accessories complete all as specified and directed. |
| 150 | Fixing only LED tube light upto 10 watts on wall/ surface mounted with 2 Nos. PVC round/ square blocks, screws complete all as specified and as directed. |
| 151 | S & F LED light fitting 1x10 watts bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size and other fixing accessories complete all as specified and directed. |
| 152 | S&F of decorative type wall light fixture made up of polycarbonate suitable for 15 watts LED retrofit of type B2 base, IP66 grade with and including 15 watts LED lamp including fixing arrangements at any heightwith nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of requiredsize complete all as specified and directed. |
| 153 | S&F of energy saving new generaation environmental friendly long life 35/36 watt LED street light fittingsIP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cableincluding taking down old unserviceable light fittings complete all as specified and directed . |
| 154 | Supply, fabricatedand fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.5 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for PCC/steel tubular poles/on wall surfaces including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed. |
| 155 | Material and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directyed. |
| 156 | M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn through and including rigid PVC conduit of required sizemedium grade (MMS) with all connected accessories such asBend, Tee, Elbow, Short piecesetc concealed in wall/roofs/floorsand including one run of 6 sqmmsingle core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surfaceas requiredfor concealedwork including taking down old unserviceable submain wiring complete all as specified and directed .(Note : (i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (v) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.) |
| 157 | S&F ofpowder coated sheet metal enclosure 415 volts AC,TPNdistribution board 4 way suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth barand MCB incomer of rating upto 100 Amps,MCB TPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DBs completeall as specified and as directed. |
| 158 | S&F of powder coated sheet metal enclosure240 volts AC, SPNdistribution board 8 wayfor flush mounting with 200 Amps copper busbar, neutral bar, earth barand MCB incomer of rating upto 200Amps, MCB SPN/DPand MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable DBs completeall as specified anddirected. |
| 159 | S&F ofMCB, SP, 6 Amps to 32 Amps , \"C\" series, 240 Volt, 10KA, 50 Hz,completeall as specified anddirected |
| 160 | S&F of MCB TPN63 Amps, 10 KA, \"C\" series, AC, 240 volts, complete all as specified anddirected. |
| 161 | S&F of MCB, SPN,40 Amps to 60 Amps, 10 KA, \"C\" series, AC, 240 volts complete all as specified anddirected. |
| 162 | S&F ofsheet metal enclosure fabricated out of 2mm thick CRCA sheet, totally enclosed type, dust & vermin proof with suitable sized supporting MS angles & suitable opening at top & bottom for entry of outgoing/ incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with two coats powder coated paint over a coat of red oxide primer (spray paint) with minimum diamentions 900mm x 750mm 200mm flush to to wall for incorporating 1 No. TPN DB 04 Nos electronic meters, etc.complete all as specified and directed. |
| 163 | S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 32Amps, 10KA \"C\" series, 240 Voltscomplete all as specified and directed. |
| 164 | S&F of Modular TV socket 1 module including 1module sunken box, bacl plate, and top cover fixed and flushed to wallcomplete all as specified and directed. |
| 165 | Taking down carefully ceiling fan from its original position and refixing the same after plaster work complete all as specified and as directyed. |
| 166 | Taking down carefully exhaust fan any size from its original position and refixing the same after plaster work complete all as specified and as directyed. |
| 167 | Taking down carefully electric meter single phase any capacity including disconnecting electric connection from its original position and refixing the samecomplete all as specified and as directyed. |
| 168 | M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nutsand washers of galvanisediron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposalof surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing completeall as specified and directed.(Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testingis deemed to be included with quoted rate). |
| 169 | Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable completeall as specified and directed.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required) |
| 170 | Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed. |
| 171 | Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed. |
| 172 | Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed. |
| 173 | M&L for brick covering with width equal to length of brick asprotection to cable with well burnt sub class ‘B’ bricks of size 230mm x 125mm x 75mm laid dry flat complete all as specified and directed. |
| 174 | M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured) |
| 175 | Layiong only old bricks asprotection to UG cable with laid dry flat complete all as specified and directed. (Note:- Old bricks obtained from Item No.169 here-in-before) |
| 176 | Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed. |
| 177 | M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection including taking down old unserviceable pipe complete all as specified and directed. |
| 178 | S&F of MCCB 4 pole, 415V,200 Amps rupturing capacity 36KAadjustable type including dismantling/taking down old unserviceable MCCB complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy