| 1 | Schedule \"A\" Part-I(BUILDING WORK) |
| 2 | Construction of Block of OTES Building (Single Storey) including all fittings & fixtures etc. complete all as shown in drawings and as specified. |
| 3 | Construction of Toilet Block for OTES Building (Single Storey) including all fittings & fixtures etc. complete all as shown in drawings and as specified. |
| 4 | Schedule \"A\" Part-II(EXCAVATION AND EARTH WORK) |
| 5 | Lump sum price worked out by contractor for\"EXCAVATION AND EARTH WORK\" as listed inSchedule \"A\" Part-II. |
| 6 | Schedule \"A\" Part- III(INTERNAL ELECTRIFICATION) |
| 7 | Lump sum price worked out by contractor for\"INTERNAL ELECTRIFICATION\" as listed inSchedule \"A\" Part- III. |
| 8 | Schedule \"A\" Part- III(INTERNAL WATER SUPPLY) |
| 9 | Lump sum price worked out by contractor for\"INTERNAL WATER SUPPLY\" as listed inSchedule \"A\" Part- IV. |
| 10 | Schedule \"A\" Part -V(FALSE CEILING) |
| 11 | Lump sum price worked out by contractor for\"(FALSE CEILING\" as listed inSchedule \"A\" Part- V. |
| 12 | Schedule \"A\" Part -VI(ROAD/PATH/CULVERT)) |
| 13 | Lump sum price worked out by contractor for\"ROAD/ PATH/ CULVERT\" as listed inSchedule \"A\" Part- VI. |
| 14 | Schedule \"A\" Part -VII (EXTERNAL WATER SUPPLY) |
| 15 | Lump sum price worked out by contractor for\"EXTERNAL WATER SUPPLY)\" as listed inSchedule \"A\" Part- VII. |
| 16 | Schedule \"A\" Part -VIII(EXTERNAL ELECTRIC SUPPLY) |
| 17 | Lump sum price worked out by contractor for\"EXTERNAL ELECTRIC SUPPLY)\" as listed inSchedule \"A\" Part- VIII. |
| 18 | Schedule \"A\" Part -IX(SEWAGE DISPOSAL) |
| 19 | Lump sum price worked out by contractor for\"SEWAGE DISPOSAL)\" as listed inSchedule \"A\" Part- IX. |
| 20 | Schedule \"A\" Part -X(MISCELLANEOUS ITEMS) |
| 21 | S&F for Wall mounted fan, PVC body AC single Phase. 230V of size 400mm sweep with, blades, and frame and louvers, complete all as specified and as directed. |
| 22 | S&F of LED bulb 10 watt, complete all as specified and directed. |
| 23 | S&F of sheet metal enclosures with, new 3/4 modular box with plate, single pole MCB and modular socket 16 Amps 3 & 6 Pincombined02 modulecomplete withonesinglepoleMCB20amps,240volts, for AC & Geyser completeallas specified and directed. |
| 24 | Drilling/cutting and tapping up to 100mm dia raising main DI line (In position) for branch connections with & including provision of suitable size ferrule and GI Nipple including necessary excavation & earth work for internal dia of pipe complete all as specified and directed by Engr-in Charge. |
| 25 | Excavation of road cuttiug by manuallyof width 45cm x 60cm depth including making good to disturb surface after the completion of work with PCC 1:2:4 type B2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc. complete all as specefied and as directed. |
| 26 | M&L for commissioning, installation and testing of maintenance free ULapproved copper bonded earth rod (earth electrode) of 10 feet length, 17.2 mm dia. made of high tensile low carbon steel rod , molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound (Bentonite powder) with each earth rod. The earth pit should be 125 mm dia. the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable lid including GI Protection pipe light grade of size 40 mm dia. with Copper strip of size 32X6 mm upto test point strip should be run on PCC block of suitable size for avoid touching to ground complete all as specified and directed by Engr-in-charge. |
| 27 | Dismantling and taking down by removing HT and LT connection of indoor/outdoor type 11/0.433KV transformer of any capacityfrom existing plateform / 4 Pole / 2 Pole structure, lowering the same carefully and shifting to other location within Air Force Station as directed by Engineer-in-Charge with and including reinstallation by any means of arrangementand testing complete all as specified and directed. |
| 28 | Shifiting and Refixing of old serviceable steel tubular swaged poles9.0 Mtr long and erecting in new location (within 2 Kms distance) or asdirected at site including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and painting of 30 cm wide red and white strips upto 1.5 mtr from bottom of the errected pole including marking of pole number complete all as specified and directed by Engineer-in-Charge.Note:(A) Rate Quoted shall be deemed to be inclusive of the following :(i) Any repair/ welding/ fabrication work on the old poles(ii) Any rusted surface on the old pole shall be treated with red oxide primer prior to application of aluminium paint.(B) Necessary excavation, earth work and PCC Work. |
| 29 | Supply and installation LT Electric control panel, cubical type, for out door use,dust & vermin prooffloor mounted made out of CRCAsteel sheet of3.15 mm thickand 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 250 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as ncluding necessary PCC work of height 45 cm from the ground level and equipped with the following items.Note: Drawing and all materials viz. MCB/ MCCB/ instruments etc. for LT panel shall be got approved by GE before fabrication. Rate for MCCBs, MCBs, instruments is included in unit rate of items. |
| 30 | INCOMERI.MCCB, 4 pole, 415 volt, 160 amps, rupturing capacity 36 KA magnetic thermal release- 01 No (Havells Cat No IHLLSEB30320 or equivalent in Siemens, Schneider)II.On load change over switch 4 pole 160 Amps- 01 NoIII. Digital Ammeter 0-300 Amps CT Operated with selector switch - 01 NoIV. Digital Volt Meter 0-500 Volts with selector switch - 01 NoV. LED Indicator lamp in three colour RYB - 03 NosOUT GOINGI. MCCB, 4 pole, 160 Amps , rupturing capacity 25 KA magnetic thermal release-01 Nos. (Havells, Siemens, Schneider)II. MCCB, 4 pole, 63 Amps , rupturing capacity 25 KA magnetic thermal release-01 Nos. |