| 1 | Excavating in trenches for foundations etc in any type of soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out complete all as specified and as directed. |
| 2 | PCC M-10 (Nominal mix) using 40 mm graded stone aggregates as in foundation filling and mass concrete complete all as specified and as directed. |
| 3 | M & L Brick work, with sub class \"B\" bricks using old size bricks having crushing strength not less than 75kg/Sqcm, straight or curved on plan,exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed. |
| 4 | M & L RCC M-25 (Design mix)in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.: basement slabs, under-reamed and mass concrete piles complete all as specified and as directed. |
| 5 | M & L RCC M-25 (Design mix) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 6 | M & L RCC M-25 (Design mix) as in roof beams, cantilevers, bressummers, lintels complete all as specified and as directed. |
| 7 | M & L Formwork to sides of concrete foundations, footings, bases of columns, raft anf raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed. |
| 8 | M & L Formwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete complete all as specified and as directed. |
| 9 | M & L Form work to sides of pillars, posts, struts, piers, columns and stanchions, for rough finished surfaces of concrete complete all as specified and as directed. |
| 10 | M & L Mild steel TMT bars 10mm dia and over cut to length, bent to shhape required, including cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips, placed in position, complete all as specified and as directed. |
| 11 | All as per item No 10 here-in-above but 6 to 10 mm dia. Of bar as in stirrups, spacers & binders complete all as specified and as directed. |
| 12 | M & L Mild steel posts and struts in fencing including cutting tops to shape as directed,drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 13 | M & L Galvanised 2 stands, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and as directed. |
| 14 | M & L Framed work such as grills,gratings,etc. with ends of bars shouldered and/or riveted, or forged into spikes;framed guard bars;barred iron doors;ladders;framed balusters;walk ways;railings;framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 15 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface finished even and smooth without using extra cement, complete all as specified and as directed. |
| 16 | Rendering 15mm thick on brick masonry or concrete surfaces other than fair faces of brick work or concrete srfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 17 | Preparation of surfaces of any description, over 10cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide zinc complete all as specified and as directed. |
| 18 | Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 19 | Returning,filling in soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 20 | Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 21 | Providing and fixing concertina coil fencing with punched tape concertina coil 450mm dia, stretched to 6m length,having 50 nos spiral turns per 6m length,spring core wire (2.59 mm thick)of high tensile strength of 1620 N/sqmm with tape (0.52mm thick) hot dip galvanised upto 20 microns,weight of each coil 7.50 to 8.00 kg and fixing the same on exusting Y-shaped angle iron with 6 horizontal R.B.T (Reinforced Barbed Tape) wire, stud lied with G.I staple sand G.I clips to retain horizontal, clips shall be @5 nos per 2 spiral turns approximate 125 clips per coil incl necessary bolts complete all as specified and as directed. |
| 22 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, complete all as specified and as directed. |
| 23 | All as per Srl item no 22 here-in-before but exc 1.5 m and not exc 3.0m deepcomplete all as specified and as directed. |
| 24 | M & L RCC (Design mix) M-25 as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in salves and like.complete all as specified and as directed. |
| 25 | M & L RCC (Design mix) M-25 as in walls, basement wall of any thickness above top of footings incl attached pilasters & buttressescomplete all as specified and as directed. |
| 26 | M & L RCC (Design mix) M-25 as fins, facias, louvers, parapet and railing exc 60 cm ht, newals, balustrade & the like complete all as specified and as directed. |
| 27 | M & L RCC (Design mix) M-25 as in stairways,incl steps, string pieces complete but excluding railing complete all as specified and as directed. |
| 28 | M & L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with fair finished complete all as specified and as directed. |
| 29 | M & L Form work to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work with fair finished complete all as specified and as directed. |
| 30 | M & L Form work to staircase with slopping or stepped soffits incl risers & strings (exc landing) with fair finished complete all as specified and as directed. |
| 31 | All as per Srl item No 30 here-in-before but 6 to 8 mm dia complete all as specified and as directed. |
| 32 | M & L Rendering 10mm thick on other than fair face of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M & L Rendering 5 mm thick onconcrete surface as in ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 34 | M & L Rendering 5 mm thick onconcrete surface as in columns, RCC walls, fins etc in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 35 | M&L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. |
| 36 | M&L for preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc complete all as specified and as directed. |
| 37 | M&L for preparing newly plastered surfaces and applying two coats of cement base paint over a coat of white washcomplete all as specified and as directed. |
| 38 | M&L for sand filling under floors or in foundation incl watering & consolidating complete all as specified and as directed. |
| 39 | M&L for 75 mm thick, PCC M-10 (nominal mix) as in sub-base to floor complete all as specified and as directed. |
| 40 | M&L for 30 mm thick, PCC M-15 (nominal mix) as in sub-base to floorcomplete all as specified and as directed. |
| 41 | M&L for 20 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishescomplete all as specified and as directed. |
| 42 | M&L for 10 mm thick screed bed or bedding layer of mortar in CM 1:3 as on vertical surfaces for laying wall finishescomplete all as specified and as directed. |
| 43 | M&L for brushingneat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed. |
| 44 | M&L for machine cut Kota stone slab flooring, 20-25 mm thick over cement screed bed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishingcomplete all as specified and as directed. |
| 45 | All as per Srl item No 44 here-in-before but on vertical surfaces such as in riser, skirting etc complete all as specified and as directed. |
| 46 | M & L Rendering 10 mm thick on fair face of brick work or concrete surface in CM 1:4 (with water proofing compound, WPC measured & paid seprately) finished even and smooth without using extra cement complete all as specified and as directed. |
| 47 | Supply only liquid water proofing compound/admixture, ISI marked complete all as specified and as directed. |
| 48 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixingcomplete all as specified and as directed. |
| 49 | Material and labour for Steel tubular swaged poles complete withcast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-31 (9.0 metres long) complete all as specified and as directed. |
| 50 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optic , incl wire 3 core 1.5 sqmm length 9 mtr,complete with IP 66 protectioncomplete all as specified and as directed. |
| 51 | Material and labour for earthing complete with galvanized steel plate earth electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 1.5 mtr below normal ground level connected to galvanized earth lead of 4.0 mm dia earth strip by means of bolts nuts and washers made of galvanized iron protected by 40mm bore light grade GI pipeup 7.5 Rm with earth strip and connected for body earthing of feeder pillar box all as specified and including PCC (1:3:6) type C2 pit and precast RCC (1:11/2:3) type A1 pit cover slab of size 300x300x50mmwith handle as shown in drawing funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work and excavation in hard/ dense soil and removal etc,complete all as specified and as directed. |
| 52 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminiumconductor of size 10 sq mm 2 core complete all as specified and as directed. |
| 53 | M&L for PVC Junction Box of size 155 x 210 x 92 mm with locking arrangement suitable for 02 nos cable connectors (single Phase & neutral),01 No MCB SP 6 Amp complete with suitable size of cable glands & MS clamps nuts, bolts & washers etccomplete all as specified and as directed. |
| 54 | M&L for GI tubes 40 mm dia \"light grade\" galvanised, with all fitting and fixed with poles for cable from trench to junction boxcomplete all as specified and as directed. |
| 55 | Excavationintrenchesnotexceeding1.5 M wideandnotexceeding1.5 Mindepthandgettingoutin soft/loosesoilorhard/densesoilfortakingup orlaying ofcable complete all as specified and as directed. |
| 56 | Al as per Srl item No 55 but exceeding 1.5 mtr wide but not exc 3.0 mtr deep complete all as specified and as directed. |
| 57 | Supply and laying dry river sand laid in trenches as cable cushioning and covering all as directed.Sand cushioning to under ground electric cable 8cm before laying and 15cm after laying the cable intrenchescomplete all as specified and as directed. |
| 58 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in pole foundationcomplete all as specified and as directed. |
| 59 | Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as inr coping of pole and stay assemblycomplete all as specified and as directed. |
| 60 | Supply and laying dry bricks over cable Mechanical protection laid flat with width equal to length of bricks with sub class B brickscomplete all as specified and as directed. |
| 61 | S & F Street light bracket made out of GI tubing suitable for 35/45/60 watt LED light light grade upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etccomplete all as specified and as directed. |
| 62 | Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular of size 4 Sqmm 2 corecomplete all as specified and as directed. |