Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PART A - ELECTRICALTaking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power/bell) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge. |
| 2 | M & L for concealed point wiring with 1.5 Sqmm single core, multistranded, PVC insulated and unsheathed copper conductor cable, 1100 volts grade, FRLS, ISI-marked, drawn through and including PVC conduit with all accessories, fixed on wall/ceiling/truss, including PVC non-metallic terminal boxes fixed on wall as required or metallic terminal boxes concealed in wall suitable for modular accessories, with cover plate and frame, and one single core 1.5 Sqmm PVC insulated and unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge.Notes:(a) Colour coding shall be as under: • Phase – Red • Neutral – Black • Earth – Green(b) Electrical wiring above false ceiling shall be drawn through medium-grade PVC conduit or PVC casing capping Note: PVC casing /capping shall be used only where conduit laying is not feasible. |
| 3 | One light point controlled by one switch |
| 4 | One ceiling fan/wall fan/exhaust fan point controlled by one switch |
| 5 | One Bell point control by one 5A bell push switch |
| 6 | One 5 Amps switch socket combination on independent board |
| 7 | One5A flush type switch socket point on same board |
| 8 | M & L for concealed point wiring in repair with FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable of size 2.5 Sqmm, 1100 volts grade, drawn through and including non-metallic rigid PVC conduit not less than 25 mm dia with all accessories, fixed on wall/ceiling, including FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable of size 2.5 Sqmm as earth continuity conductor connected to common earth dolly, and PVC moulded modular box, ISI-marked, suitable for housing switches, sockets, regulators, etc., complete all as specified and directed by Engineer-in-Charge.Note:(a) Colour coding shall be followed as under: • Phase – Red • Neutral – Black • Earth – Green(b) Conduit: ISI-marked medium-grade rigid PVC conduitNote- PVC casing capping shall be used only where conduit laying is not feasible. |
| 9 | One15A flush type switch socket point on independent board |
| 10 | M & L for concealed sub-main wiring in repair with two runs of 4 Sqmm and one run of 4 Sqmm FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, with proper colour coding, drawn through and including non-metallic PVC conduit not less than 25 mm dia, ISI-marked, with all necessary accessories such as PVC elbows, tees, junction boxes, etc., fixed on wall/ceiling and connected up complete all as specified and directed by Engineer-in-Charge. |
| 11 | M & L for concealed sub-main wiring with two runs of 6.0 Sqmm FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, drawn through and including heavy-grade PVC conduit not less than 25 mm dia (internal), with all accessories such as tees, elbows, junction boxes, and reducers as required, including one run of 6.0 Sqmm FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable as earth continuity conductor (main/earth dolly), taking down old unserviceable wiring and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.Note:(a) Colour coding shall be as under: • Phase – Red • Neutral – Black • Earth – Green |
| 12 | S & F in repair LED recess-mounted fitting 36W, 2\"×2\", CRCA LED slim panel type,Minimum efficiency 120Lumen/watt with recessed mounting, powder-coated white CRCA frame, full-glow LED panel including control gear and lamp, complete all as specified and directed by Engineer-in-Charge. |
| 13 | S & F in repair LED street/building security light fitting 60W, Minimum efficiency 120Lumen/watt with high-pressure die-cast aluminium housing, toughened glass cover, individual LEDs with secondary optics, IP66 protection, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fixing in repair walll/surface mounted 20W LED batten,Minimum efficiency 120Lumen/wattfitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. |
| 15 | S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed. |
| 16 | Supply and fix in repairmodular switch 1 way 16 Amps1 module 240 volts flush type |
| 17 | S&F for modular fan regulator fan step regulator, 120W - 2 modular step type Make: Roma/Legrand |
| 18 | Supply and fix in repairmodularsocket 6 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge. |
| 19 | Supply and fix in repairmodularsocket 16 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge. |
| 20 | S & F moduler bell push 6A, 1 module all as specified and directed by Engr-in-Charge. |
| 21 | S&F Ding dong AC 230Voltssingle polebell 50 Hzall as specified and directed by Engr-in-Charge. |
| 22 | M & L for taking down split/window type air-conditioner unit from existing position and refixing it in new position/location, including supply and fixing of necessary additional accessories as required, replacement of existing copper tubing with new copper pipe as required, leak testing, testing and commissioning complete, all as specified and directed by Engineer-in-Charge. |
| 23 | S & F copper tubing of suitable diameter for suction and liquid discharge lines, duly insulated with appropriate insulation material, including making holes in wall for passing pipes and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 24 | S & F in repair 20 Amps single pole and neutral (SPN) enclosure with two-pin and earth plug and socket, complete with one single pole MCB, complete all as specified and directed by Engineer-in-Charge.Make: Legrand (Cat. No. 507814) / Siemens / GE or equivalent. |
| 25 | M & L for disconnecting and taking down ceiling fan of any size and make for overhauling, dismantling parts, cleaning and removing old grease and applying new lubricating oil/grease, varnishing of winding, removing dust and rust, and applying two coats of white enamel paint over one coat of steel primer, assembling and refixing in the same position, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing ceiling fan, 230 Volts, 50 Hz, AC, 1200 mm sweep, energy-efficient model with Brushless Direct Current Motor (BLDC) technology, delivering minimum air delivery of 210 CMM, with service value not less than 6.0, conforming to BEE 5-Star rating as per latest BEE Level, complete with down rod, hanging arrangement, and additional safety steel wire rope, including all necessary electrical connections with 3-core 0.75 Sqmm PVC insulated copper conductor flexible cable and allied accessories, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Disconnecting and taking down the fan and Overhauling of exhaust fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat gray paint over a coat of steel primer,assembling and refixing at same position complete all as specified. |
| 28 | Supply and fixing of heavy duty Exhaust fan, steel body AC single phase, 230volts, 50Hz of size 380mm sweep with blades, frames and louvers with and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 29 | Supply and fixing wall-mounted fan, 400 mm sweep, single-phase, 230 Volts, 50 Hz, AC, energy-efficient model with aerodynamically balanced blades, powder-coated guard, oscillating mechanism, speed control regulator, complete with heavy-duty mounting bracket and all necessary electrical connections and accessories, conforming to IS:374 (latest amendment), complete all as specified and directed by Engineer-in-Charge. |
| 30 | S & F on replacement of hanger clamp assembly with down rod up to 3 feet long for suspension of ceiling fan, complete with nuts, bolts, washers, split pins, and all necessary fittings, complete all as specified and directed by Engineer-in-Charge. |
| 31 | S & F in repair ceiling rose, surface type, made of bakelite, three terminal, size 60 × 50 mm, suitable for 240 volts AC supply, complete all as specified and directed by Engineer-in-Charge. |
| 32 | S & F in replacement of steel sheet enclosure, double door type, IP54 / IK09 protection, DB SPN 8-way, 240 volts AC, factory made, suitable for housing MCB SPN with 200 Amps copper bus bar, complete all as specified and directed by Engineer-in-Charge. |
| 33 | S & F in replacement of steel sheet enclosure, double door type, IP54 / IK09 protection, DB SPN 12-way, 240 volts AC, factory made, suitable for housing MCB SPN with 200 Amps copper bus bar, complete all as specified and directed by Engineer-in-Charge. |
| 34 | S & F in repair distribution board, double door, pre-wired type, made of CRCA mild steel sheet with epoxy powder coating or insulated polyester surface finish, IP54 & IK09 protection, surface mounting, VTPN 6-way, 440 volts, with 200 Amps copper bus bar, dust and vermin proof, suitable for incorporation of MCBs, complete all as specified and directed by Engineer-in-Charge.Make: Legrand / Siemens / GE or equivalent. |
| 35 | S & F in repair MCB SP 6 - 32 Amps, 10 KA Rupturing capacity complete all as specified and directed by Engineer-in-Charge. |
| 36 | S & F in repair MCB SPN 40-63 Amps, 10 KA Rupturing capacity complete all as specified and directed by Engineer-in-Charge. |
| 37 | S & F, testing and commissioning in repair of maintenance-free earthing system (JEF ECO SAFE or equivalent), comprising high-tensile low-carbon steel electrode of 3.0 metres length and 25 mm dia, molecularly bonded with minimum 250 microns of copper coating on the outer surface, conforming to UL–467 requirements, including carbon-based conductive back-fill compound (Powerfill/Loresco or equivalent) having resistivity less than 0.12 Ohm-metre as per Clause 14.5 (D) of IEEE–80 standard.The back-fill compound shall be electronically conductive (metallic in nature), shall not depend on moisture for conduction, shall be environment-friendly, shall solidify after mixing with water to form a concrete-like mass, and shall not leach or diffuse into the soil. One 50-pound (22.7 kg) bag of compound shall be used per earthing set. The set shall include suitable earthing termination clamp, weatherproof earth pit chamber with cover, and complete installation including excavation, placement, backfilling, watering, and testing on completion, all as specified and directed by Engineer-in-Charge.Note:Back-fill compound shall be used without mixing with soil during installation. |
| 38 | M & L for 4 mm dia GI wire as earth continuity conductor or main earthing lead, fixed to wall or buried in ground and connected to panel/transformer, including 20 mm dia GI protection pipe, light grade, complete all as specified and directed by Engineer-in-Charge. |
| 39 | S & F rigid non-metallic PVC conduit 20 mm dia, with all fittings and accessories such as tees, bends, elbows, reducers, mouth ends, GI saddles, full-threaded screws, and nylon rawl plugs, fixed on wall/roof surface, complete all as specified and directed by Engineer-in-Charge. |
| 40 | S & F rigid non-metallic PVC conduit 40 mm dia, with all fittings and accessories such as tees, bends, elbows, reducers, mouth ends, GI saddles, full-threaded screws, and nylon rawl plugs, fixed on wall/roof surface, complete all as specified and directed by Engineer-in-Charge. |
| 41 | S & F in repair MCCB 3 Pole, 100 Amps, 16 kA breaking capacity, thermal magnetic type, 415 Volts, complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & F touch-free infrared hand dryer, minimum capacity 1150 Watts, single-phase, 230 Volts, wall-mounted type, complete all as specified and directed by Engineer-in-Charge. |
| 43 | S & F PVC moulded water storage tank, 2000 litres capacity, multilayered (ISI-marked), cylindrical vertical type, complete with inlet, outlet, overflow and wash-out connections, closed top cover, including hoisting in position, all as specified and directed by Engineer-in-Charge. |
| 44 | S & F ball valve (ISI marked), brass, high pressure, with polythene float and fly nut, 25 mm dia, complete screwed to iron or brass ferrule, complete all as specified and directed by Engineer-in-Charge. |
| 45 | S & F gun-metal gate valve(ISI marked) with iron wheel head, screwed both ends for 25 mm bore GI pipe, including provision of union, nipples, and sockets, complete all as specified and directed by Engineer-in-Charge. |
| 46 | S & F GI tubing, medium grade, 25 mm dia, with all fittings (such as union, tee, bend, elbow, reducer, and socket), fixed on wall and ceiling or laid in floor/trench, complete all as specified and directed by Engineer-in-Charge. |
| 47 | M & L for concealed point wiring in repair with FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable of 4.0 Sqmm size, 1100 volts grade, drawn through and including non-metallic rigid PVC conduit not less than 25 mm dia with all accessories, fixed on wall/ceiling, including one run of 4.0 Sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor connected to common earth dolly, including required number and size of modular box with cover plate and frame for modular accessories, complete necessary electrical connections for each work station point comprising three Nos 5A sockets and one No. 15A switch socket outlet, complete all as specified and directed by Engineer-in-Charge. |
| 48 | M & L for concealed sub-main wiring in repair with two runs of 10 Sqmm and one run of 10 Sqmm FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable with proper colour coding, drawn through and including non-metallic PVC conduit not less than 25 mm dia, ISI-marked, with all accessories such as PVC elbow, tee, junction box, etc., fixed on wall, including connecting up, complete all as specified and directed by Engineer-in-Charge. |
| 49 | S & F in repair wall/surface-mounted 10W (120 lumen/watt) LED batten fitting, Minimum efficiency 120lumen/watt ,2 ft long, engineering plastic body with white acrylic cover, complete with all internal wiring, pre-wired accessories, and including fixing on wall/ceiling with PVC round/square block (2 Nos), connecting up with twin-core copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 50 | S & F in repair MCCB 160 Amps, 4 Pole, 415 Volts, 25 kA breaking capacity, adjustable thermal and magnetic trip setting, complete all as specified and directed by Engineer-in-Charge. |
| 51 | S & F in repair exhaust fan, 300 mm sweep, heavy-duty type, complete with MS louvers, mounted in suitable opening arrangement, suitable for operation on 230 Volts, single phase, 50 Hz AC supply, including connection with two-core, PVC insulated, sheathed, flexible copper conductor cable (23/0.0076) from ceiling rose to fan, complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply laying & testing in repair XLPE insulated, screened, PVC bedded, galvanised steel strip/wire armoured, heavy-duty electric power cable, 1100 volts grade, with stranded copper conductor of size 25 Sqmm, 4-core, laid in trenches, along walls/floor, etc., including fixing accessories and required materials for proper termination and testing, complete all as specified and directed by Engineer-in-Charge. |
| 53 | M & L for concealed sub-main wiring with four runs of 10 Sqmm FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, drawn through and including heavy-grade PVC conduit not less than 25 mm dia, with all fittings such as tees, elbows, junction boxes, and reducers, including one run of 10 Sqmm FRLS PVC insulated, unsheathed copper conductor cable as earth continuity conductor, including taking down old unserviceable sub-main wiring, making good disturbed surfaces, and connecting up, complete all as specified and directed by Engineer-in-Charge.Note:(a) Colour coding shall be followed as – Phase: Red; Neutral: Black; Earth: Green. |
| 54 | S & F in replacement GI cable tray, perforated type, 2 mm thick, 250 × 50 mm size, including pre-fabricated GI clamp for fixing/supporting, with 0.71 mm thick aluminium sheet cover (alloy 31000 H4), complete with necessary fittings for mounting on brick/stone walls vertically or horizontally, including bending, shaping, drilling, welding, cutting, and fixing arrangement, complete all as specified and directed by Engineer-in-Charge. |
| 55 | S & F in repair distribution board, double-door, pre-wired type, made of CRCA mild steel sheet, epoxy powder-coated or polyester insulated surface finish, IP54 & IK09 protection, surface mounting, TPN 12-way, 440 Volts, with 200 Amps copper bus bar, dust and vermin proof, suitable for incorporation of MCBs, complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply & Laying & testing in repairXLPE insulated, screened, PVC bedded, galvanised steel strip/wire armoured electric power cable (heavy duty), 1100 volts grade, with stranded copper conductor of size 50 Sqmm, 4-core, laid in trenches/along wall/floor, including required material for termination and fixing arrangement, complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply & Laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip/wire armoured electric power cable (heavy duty), 1100 volts grade, with stranded aluminium conductor of size 95 Sqmm, 3.5-core, laid in trenches/along wall/floor, including required material for termination and fixing arrangement, complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed |
| 59 | S & F in repair MCCB 4P 100 Amps, 16KA, thermal magnetic,415volts complete all as specified and directed. Make :Legrand cat No 420015/Seimens/GE |
| 60 | S & F in repair MCCB 4P 160 Amps,25 KA, thermal magnetic,415volts complete all as specified and directed. |
| 61 | S & F distribution board, double door, pre-wired type, made out of CRCA mild steel sheet, with epoxy powder coating or polyester insulated finish, IP54 & IK09 protection, surface-mounted, VTPN 4-way, 440 Volts, with 200 Amps copper bus bar, dust and vermin proof, suitable for incorporation of MCBs, complete all as specified and directed by Engineer-in-Charge. |
| 62 | S & F in repair double-door type SPN DB, 12-way, 240 Volts, with 100A copper bus bar per phase, metallic enclosure, IP43 & IK09 protection, suitable for housing MCBs, complete all as specified and directed by Engineer-in-Charge.Note: MCB DBs shall be concealed in wall wherever possible, including making good the surface to match the surroundings. |
| 63 | S & F XLPE insulated, screened, PVC bedded, galvanised steel strip/wire armoured, heavy-duty aluminium conductor power cable, 1100 Volts grade, 25 Sqmm, 4-core, laid in trenches/along wall/floor, with all necessary fixing and termination materials, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, in loose/soft soil, including getting out excavated material, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 67 | M & L for sand cushioning in trenches using fine dry sand — 8 cm below and 15 cm above the laid cable (punned down to 10 cm), including spreading, levelling, and ramming, complete all as specified and directed by Engineer-in-Charge.Note: Only compacted thickness shall be measured and paid. |
| 68 | M & L for unreinforced, precast concrete cable cover of size 250 × 150 × 40 mm, class LV Type–1, for cable protection, laid in trenches as specified and directed by Engineer-in-Charge. |
| 69 | S & F GI tubing, light grade, 40 mm dia, with all fittings, laid in trenches/fixed on wall or ceiling, including dismantling of old pipe, complete all as specified and directed by Engineer-in-Charge. |
| 70 | M & L for cutting road/hard standing for laying of cables and reinstating/remetalling to match the existing surface, including making good the disturbed portion, complete all as specified and directed by Engineer-in-Charge. |
| 71 | S & F and installation of high-wall split type air-conditioner unit, indoor and outdoor, 1.5 TR capacity, complete with cordless remote control unit, in-built air ioniser and plasma filter for improved indoor air quality, minimum 5-star rating (latest label period)with EER not less than 3.2, complete all as specified and directed by Engineer-in-Charge.Note: Rate quoted shall be deemed to include supporting brackets for outdoor unit. |
| 72 | S & F single pole and neutral (SPN) enclosure with two-pin and earth plug and socket, complete with one single pole MCB, 20 Amps, 240 Volts, complete all as specified and directed by Engineer-in-Charge. |
| 73 | M & L for sub-main wiring with two runs of 4 Sqmm single-core, multi-stranded, FRLS PVC insulated and unsheathed copper conductor cable, 1100 Volts grade, ISI-marked, drawn through and including PVC non-metallic casing and capping with all accessories, fixed on wall/ceiling/truss, including one run of 4 Sqmm FRLS PVC insulated unsheathed copper conductor cable as earth continuity conductor connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge. |
| 74 | S & F rigid non-metallic PVC conduit, 32 mm dia, complete with all accessories such as tees, bends, elbows, reducers, mouth ends, GI saddles, full-threaded screws and nylon rawl plugs, fixed on wall or roof surface, complete all as specified and directed by Engineer-in-Charge. |
| 75 | S & F and clamping copper tubing for suction and liquid discharge lines, duly insulated with suitable insulation material, including making holes in wall for passing pipes and making good disturbed surfaces to match existing finish, complete all as specified and directed by Engineer-in-Charge. |
| 76 | PART B B/R WORKSM & L for roughening old concrete surfaces by picking, sweeping, cleaning and washing down with water to remove dust, loose material, etc., including taking down old tarfelt, complete all as specified and directed by Engineer-in-Charge. |
| 77 | M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) as levelling course on roof surfaces and coping, complete all as specified and directed. |
| 78 | M & L for applying 1.5 mm thick modified bitumen waterproofing membrane with cross-laminated HDPE film for wet application on roof, to be applied on saturated surface dry concrete with bonding slurry; membrane to have overlaps of minimum 80 mm, pressed together using roller; tensile strength not less than 25 MPa and elongation ~500% as per ASTM D412; resistance to puncture ~900 N as per ASTM E154; adhesion in peel ~1.8 N/mm as per ASTM D903; and resistant to lateral water migration ~71 m as per ASTM D5385, complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 79 | Taking down cement or cement-lime plaster of any description on brick or stone walls, including raking out joints, hacking for key, scrubbing down with water, and removing rubbish off the premises, complete all as specified and directed. |
| 80 | M & L for rendering 15 mm thick in cement mortar (1:6) on brick surfaces, fair finished, complete all as specified and directed. |
| 81 | M & L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces such as ceiling, finished even and smooth without using extra cement, complete all as specified and directed. |
| 82 | M&L rendering 20mm thick Pre polymer modified ready mixed cement based plastrer in two coats(12mm inner coat 8mm finishing coat).Polymer modified ready mixed cement based plastrer should having min composition of cemne and sand 1:4 using fully treated dry, well graded natural sand confirming to IS 383 suitable for external plastering having low rebound properties, low water demand for curing proprities, mechanical mixing with water in a metalic tray to only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl making grooves of existing size complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply only integral waterproofing compound, complete all as specified and directed. |
| 84 | Breaking out loose or distressed concrete carefully, without damaging sound concrete, by sharp chisel or low-impact hammer; cleaning surface with water jet pressure (4 to 5 kg/cm²) to remove chlorides and loose particles, air drying the surface, and carrying out the work with full safety gear and supervision by qualified personnel, complete all as specified and directed by Engineer-in-Charge. |
| 85 | Material & Labour for Cleaning the existing reinforcement with hammer tapping and wire Brush/ rotary wire brush , fixed to hand drill machine, making the surfaces free form loose corrosion material, dirt scaling etc. complete. Applying two coats of polymer based alkaline rust converting primer confirming to ASTM-B 117 by means of paint brush, liberally all over in two coats of 1 hour between the costs, The product should converts the rust in to stable organo metallic complex molecule layer, this should also act as primer to further treatment of steel etc. complete. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor. (the damage celling/ concrete al be measured) etc. complete all as specified and directed by Engineer-in-Charge.Note : Work shall be done by authorized applicator only |
| 86 | Anticorrosive treatment to Reinforcement application of two coats of IPNETRB (CBRI known how) on expose reinforcement in two coats with time interval) of minimum 4 hours between each coat. The application shall be by brush, Application is allowed to dry for further treatment. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damage ceiling / concrete all be measured) etc. complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 87 | Providing and applying two coats of concrete-penetrating hi-tech corrosion inhibitor compound over prepared concrete surface, ensuring cathodic and anodic protection simultaneously; work to be executed under qualified supervision with all safety gear, complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 88 | Formwork to sides and soffits of floor or roof beams, haunchings, girders, lintels, cantilevers, shelves, and supports, including splays and overhangs, in flat rough-finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 89 | Providing and applying 15 mm thick polymer mortar to load carrying R.C.C member in two layers in proportion of 1:5:15 by weight polymer of approved quality and make, cement and wash quartz sand with required W.C. ratio for desired floating, curing after initial setting time etc. complete all as specified and directed by Engineer-in-Charge. |
| 90 | Providing fabricating & fixing in position Tor steel TMT bar reinforcement conforming to IS 1786 or 1985 (third revision) code specifications including cutting, bending placing as per IS 2502=1963 at any position / level with 0.9mm dia annealed binding wire also including wastages etc. all complete all as specified and directed by Engineer-in-Charge. |
| 91 | Providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C- 882-87 using nylon brushes scaffolding labour etc. complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 92 | Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc.complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 93 | Drilling and fixing Teflon perforated nozzles in RCC member, including drilling 14 mm dia. 50 to 100mm deep holes in structural members at in cle the intervals of 600 mm in staggared manner of as directed by the consultants in RCC structural elements. Clean the holes by air blower prior to fixing nozzles. fixing of nozzels in cleaned holes. external end of nozzles to be machined to receive outlet of grouting gun. nozzel is fixed by means of epoxy by means of epoxy sealent to ensure complete sealing . cure the system for min. 12 hours. the work should be be carried out with all the safety measures like like helmet, safety belt and adequate labour insurance under the supervision of qualifed supervisor. etc complete all as specified and directed by Engineer-in-Charge. Note : work shall be done by authorized applicator only |
| 94 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, unctions of pipes and masonry with polymer mixed slurry complete all as specified and directed by Engineer-in-Charge. Note : Work shall be done by authorized applicator only |
| 95 | Disconnection existing tanks, setting aside (or lowering if required) for cleaning etc and hoisting and reconnecting and re-fixing in the sameposition capacity exc 1000 Ltr and n.exc 2000 Ltrcomplete all as specified and directed by Engineer-in-Charge. |
| 96 | Taking up or down existing GI water tubing, including removal of old steel tubing with fittings, and refixing in new or old position (walls, ceilings, floors, etc.), complete with all fittings of 25 mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 97 | Taking up or down existing GI water tubing, including removal of old steel tubing with fittings, and refixing in new or old position (walls, ceilings, floors, etc.), complete with all fittings of 20 mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 98 | S & F GI water tubing, medium grade, 20 mm bore, with all fittings, fixed complete to walls, ceilings, or laid in floors, complete all as specified and directed by Engineer-in-Charge. |
| 99 | S & F GI water tubing, medium grade, 25 mm bore, with all fittings, fixed complete to walls, ceilings, or laid in floors, complete all as specified and directed by Engineer-in-Charge. |
| 100 | Taking down chowkats or frames not exceeding 1.5 Sqm each, with shutters (without taking off shutters from the frame), complete all as specified and directed by Engineer-in-Charge. |
| 101 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each, with shutters (without taking off shutters from the frame), complete all as specified and directed by Engineer-in-Charge. |
| 102 | Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 103 | S & F flush shutters, 30 mm thick, solid core construction, with particle board core and plywood face panels, commercial type, on both sides, complete all as specified and directed by Engineer-in-Charge. |
| 104 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for frame of doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as specified and directed. Note : Work shall be done by authorized applicator only |
| 105 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as specified and directed. Note : Work shall be done by authorized applicator only |
| 106 | S & F aluminium grill with and including suitable anodised aluminium frame (F/H section), fixed to existing window frame with C.P. brass or stainless steel screws at 200 mm centres, complete all as specified and directed by Engineer-in-Charge. |
| 107 | S & F 4 mm thick selected quality sheet glass for aluminium windows/shutters, fixed with oil putty and rubber gasket, each pane not exceeding 0.5 Sqm, complete all as specified and directed. |
| 108 | S & F aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with aluminium wire staples, complete all as specified and directed. |
| 109 | S & F aluminium alloy sliding door bolt, 300 mm long, with hasp and staple (bolt type), fixing clips of sheet cast or extruded section, and fixing bolts, complete all as specified and directed. |
| 110 | S & F aluminium anodised barrel tower bolt, 200 mm long, of extruded section, complete all as specified and directed. |
| 111 | S & F aluminium anodised barrel tower bolt, 150 mm long, of extruded section, complete all as specified and directed. |
| 112 | S&S & F aluminium alloy handles, 150 mm long, fabricated from extruded section, ISI-marked, complete all as specified and directed. |
| 113 | S & F butt hinges, 125 mm long, heavy weight, cold rolled mild steel, complete all as specified and directed. |
| 114 | S & F floor door stopper, 140 mm long, aluminium alloy body and tongue, anodised, with hard-drawn steel spring, complete all as specified and directed. |
| 115 | Dismantling wall and ceiling boards (of fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets of any thickness, including cover fillets, complete all as specified and directed. |
| 116 | M & L for false ceiling made of 600 × 600 × 4 mm thick non-asbestos fibre cement designer/coloured ceiling tiles/panels, fixed in anodised aluminium framework, complete all as specified and directed by Engineer-in-Charge. |
| 117 | Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store, and disposing of unserviceable material outside MD land, complete all as specified and directed. |
| 118 | M & L for non-skid coloured ceramic tiles, 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick screed bed in cement mortar (1:4), complete all as specified and directed. |
| 119 | M & L for coloured glazed ceramic tiles, 450 × 300 × 7-8 mm thick, fixed on vertical surfaces such as skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10 mm thick rendering in cement mortar (1:3), complete all as specified and directed. |
| 120 | Supply & Fixing in repairs 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 160mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified |
| 121 | S & F PVC (SWR) bends, 160 mm dia bore, any radius, complete all as specified and directed by Engineer-in-Charge. |
| 122 | Supply & Fixing in repairs 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified |
| 123 | S & F PVC (SWR) bends, 110 mm dia bore, any radius, complete all as specified and directed by Engineer-in-Charge. |
| 124 | S & F in repair vitreous china wash-down water closet pan (pedestal pattern), white, excluding fixing bolts, flushing cistern, and flush pipe, including connection to trap and drain (or outgoing pipe), flushing pipe, antisiphonage pipe, etc., complete all as specified and directed by Engineer-in-Charge. |
| 125 | S & F in repair PVC valveless syphonic action low-level flushing cistern, white, 10-litre capacity, with inlet ball valve, float, and handle, including brackets and all necessary fittings, complete all as specified and directed by Engineer-in-Charge. |
| 126 | S & F in repair vitreous china wash-hand basin, flat-back type, size 550 × 400 mm, white, including brackets, 15 mm dia chromium-plated brass waste coupling, 32 mm dia PVC waste pipe 900 mm long, and necessary connections, complete all as specified and directed by Engineer-in-Charge. |
| 127 | S & F vitreous china urinal, half-stall type, white, excluding flushing cistern, flush pipe, and waste pipe, complete all as specified and directed by Engineer-in-Charge. |
| 128 | S & F in repair fancy type CP stop/angle cock, 15 mm dia, screwed for iron pipe, fixed complete as per sample and directed by Engineer-in-Charge. |
| 129 | S & F in repair fancy type CP bib cock, 15 mm dia, screwed for iron pipe, fixed complete all as specified and directed by Engineer-in-Charge. |
| 130 | S & F in repair fancy type CP pillar tap, 15 mm dia, cast copper alloy, with capstan heads, high-pressure type, long screwed shanks, and fly nuts, screwed for iron pipe, fixed complete all as specified and directed by Engineer-in-Charge. |
| 131 | S & F in repair brass chromium-plated shower rose, 125 mm dia, with or without swivel joint, including fixing to steel pipe or union, complete all as specified and directed by Engineer-in-Charge. |
| 132 | S & F in repair health faucet, ABS body, mild steel chromium-plated, suitable for 15 mm dia pipe, complete with 1.25 metre long flexible tube and ABS wall hook, fixed in position with all connections, complete all as specified and directed by Engineer-in-Charge. |
| 133 | S & F PVC connection, 450 mm long, 15 mm dia, with PTMT nuts, complete all as specified and directed by Engineer-in-Charge. |
| 134 | S & F PVC connection, 600 mm long, 15 mm dia, with PTMT nuts, complete all as specified and directed by Engineer-in-Charge. |
| 135 | S & F in repair stainless steel toilet paper holder, flat recessed type, complete all as specified and directed by Engineer-in-Charge. |
| 136 | S & F in repair stainless steel soap dish holder, fixed with suitable screws as per sample, complete all as specified and directed by Engineer-in-Charge. |
| 137 | S&F in repairs coner glass shelf incl bracket fixed with suitable screw as per sample and complete directed by the Engr-in-Charge. |
| 138 | S&F in repairs CP towel rail 600 mm long withround flange complete all as specified and as directed |
| 139 | S&F mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 140 | Dismantling plain or corrugated steel/AC roof sheets any gauge, thickness, including Nainital or similar pattern roof covering all as specified and directed. |
| 141 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 142 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified. |
| 143 | M& L for 75mm thick PCC 1:3:6type C2 using 40mm graded granite stone aggregate as in subbase including necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 144 | M&L for machine pressedcheqered cement coloured tiles of size 300x300x22-25mm thickmix with grey cement laid over 15mm thick screed bed in CM 1:4set and jointed and pointedinneat cement slurry in floorscomplete all as specified and directed by Engineer -in-Charge. |
| 145 | M & L for preparation of newly plastered surfaces of walls and applying two or more coats of 1st quality acrylic distemper (ready mixed), having VOC content less than 50 g/L, of approved manufacture and required shade, over and including one coat of alkali-resistant primer, complete all as specified and directed by Engineer-in-Charge. |
| 146 | M & L for preparation of newly plastered surfaces of ceiling and applying two or more coats of 1st quality acrylic distemper (ready mixed), having VOC content less than 50 g/L, of approved manufacture and required shade, over and including one coat of alkali-resistant primer, complete all as specified and directed by Engineer-in-Charge. |
| 147 | M & L for preparation of newly plastered surfaces of walls and finishing with Premium Acrylic Smooth Exterior Paint with Silicone additives, of required shade; new work (two or more coats applied @ 1.43 Litre per 10 Sqm) over and including a priming coat of exterior primer applied @ 2.20 Kg per 10 Sqm, including necessary scaffolding for high-rise buildings, complete all as specified and directed by Engineer-in-Charge. |
| 148 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth, and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc-chromate primer, complete all as specified and directed by Engineer-in-Charge. |
| 149 | M & L for complete removal of existing treatment from old decorated wall surfaces and applying two or more coats of 1st quality acrylic distemper (ready mixed), having VOC content less than 50 g/L, of approved manufacturer and required shade, over and including one coat of alkali-resistant primer, complete all as specified and directed by Engineer-in-Charge. |
| 150 | M&L for complete removal of existing treatment of old decorated surfaces of ceiling and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, as per manufacturer\"s specification. Two or more coats on new work complete all as specified and directed. |
| 151 | M&L for complete removal of existing treatment of old decorated surfaces of wall and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) includingnecessary scaffolding for high raise bldg complete all as specified and as directed |
| 152 | Removing building materials etc.to a distance of 10Km, including loading, unloading and stacking at the destination |
| 153 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings such as heads, shoes, bends, swan necks, etc., and removing to store, measured overall along the centre line of the pipe over fittings and accessories, complete all as specified and directed by Engineer-in-Charge. |
| 154 | Taking up or down steel tubing, 15 mm bore, including cleaning for refixing or removing to store, complete all as specified and directed by Engineer-in-Charge. |
| 155 | Demolition of brickwork or stone masonry built in cement mortar, including all quoins, arches, and pillars, but excluding ashlar facings, dressed stone work, and precast concrete articles, including coping, complete all as specified and directed by Engineer-in-Charge. |
| 156 | Supply, laying, connection, and testing of GI tubing,15 mm dia, medium grade, with all fittings, fixed complete to walls and ceilings or laid in floors, including all necessary connections, complete all as specified and directed by Engineer-in-Charge, for the following sizes: |
| 157 | S&F in gun metal globe or gate valve(ISI Marked), 20 mm bore, with iron wheel head, screwed both ends for iron pipe, fixed in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 158 | S&F in repairs 20 mm bore ball brass valve(ISI Marked), high pressure type, with polythene float and flynut, screwed for iron pipe or brass ferrule, fixed complete all as specified and directed by Engineer-in-Charge.. |
| 159 | S&F 4.8 mm thick selected quality sheet glass for aluminium windows/shutters, fixed with rubber gasket and glazing clips complete, all as specified and directed by Engineer-in-Charge. |
| 160 | S & F butt hinges, 100 mm size, cast brass, with mild steel hinge pin, bright polished, type B-11, fixed complete all as specified and directed by Engineer-in-Charge. |
| 161 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire, with an average width of aperture 1.40 mm, fixed with stainless steel staples, complete all as specified and directed by Engineer-in-Charge. |
| 162 | S & F in repairs prelaminated particle board, 18/19 mm thick, exterior grade, prelaminated one side with decorative lamination and other side balancing white lamination, fixed with screws to framework for cupboard or similar work, including 6 mm thick teak wood beading all around, complete all as specified and directed by Engineer-in-Charge. |
| 163 | Dismantling stone slab and tiles of of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed. |
| 164 | S&F in repair for seat cover for pedestal pan with plastic water closet seat , black or white, closed pattern with flat bottom and covermild steel chromium plated or aluminised hinging devicecomplete all as specified and directed. |
| 165 | S & F in repair counter-top wash hand basin, vitreous china, white, including chromium-plated brass waste coupling, PVC waste pipe, and bottle trap, complete all as specified and directed by Engineer-in-Charge. |
| 166 | S & F bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood backing, and fixed to wooden plugs or screwed in all corners with chromium-plated brass screws and cup washers, complete all as specified and directed by Engineer-in-Charge. |
| 167 | S&F in repairs 32mm dia PVC waste pipe for WHB and urinals fixed in repairs complete all as specified and directed. |
| 168 | S&F overhead shower of 100 mm round shape single flow (ABS Body chromium plated with gray face plate) with rubit cleaning system complete all as specified and as directed |
| 169 | S & F hand dryer, wall-mounted type, automatic operation, complete all as specified and directed by Engineer-in-Charge. |
| 170 | S & F in repair towel ring, square shape with round flange, complete all as specified and directed by Engineer-in-Charge. |
| 171 | S & F in repair health faucet, ABS body, with 8 mm dia flexible hose 1 metre long and wall hook , complete all as specified and directed by Engineer-in-Charge. |
| 172 | Taking down chowkats or frames with shutters (without taking shutters off from frame), not exceeding 1.5 Sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 173 | M & L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 174 | M & L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for complete all as specified and as directed by EIC. |
| 175 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium ally sheet foundation box, main body with stainless steel cover, governing pivot made of bras, other parts made of mild steel heavy duty and fixed all as specified and directed. |
| 176 | M&L brick work with sub class \"B\" bricks old size, straight or curved on plan exc 6m mean radius in cement mortar 1:6 complete all as specified. |
| 177 | M&L light shade virified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchin floor including15mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.Note : Engr-in-Charge will select sample from latest catalouge. |
| 178 | M&L preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling complete all as specified and directed. |
| 179 | M&L prepration of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper on plastered/decorated wall surfaces complete all as specified and directed. |
| 180 | M&L for preparation of old surafces of ceiling and applying two coat of white wash on ceiling etc complete all as specified |
| 181 | Removing of bldg materials (Debris) exc 5 KM but not exc15.00 KM and depositing where direted. |
| 182 | M&L for applying 2 mm thick wall care putty for making the surface even & smooth complete all as specified and as directed. |
| 183 | M&L for double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes etc complete all as specified and directed. (Note : Colour of tile will be decided by Engg-in-Charge). |
| 184 | M&L for double charged vitrified ceramic tiles 10mm thick(square/rectangular) polished,area of each tile not exceeding 0.36sqm, for work on vertical surfaces such as skirting or dado etc incl 10mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 etc complete all as specified and directed. |
| 185 | S&F 4 mm thick Bakelite sheet, decorative type, laminated on both sides with approved shade and pattern, fixed in position complete all as specified and directed by Engineer-in-Charge. |
| 186 | S&F anodised aluminum grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade Ac15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminum standard section around the opening,all complete as per requirement and direction of Engineer-in-charge. |
| 187 | M&L for Anodised aluminum snap grid framework for false ceiling of grid size 605x605mm with hangers 6mm dia G.I. (iupto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with 4mm Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminum framework wirh screws etc or fixing in 600mmx 600mm etc complete all as specified and directed |
| 188 | S&F 5.5 mm thick sheet glass, exceeding 0.5 sqm in each pane, ground / obscured / frosted on one side, of ordinary quality, glazed with oil putty or fixed with clips in any size of pane, complete all as specified and directed by Engineer-in-Charge. |
| 189 | M&L 12 mm thick prelaminated particle board,interior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminum/timber frame work etc complete all as specified and directed. |
| 190 | S&F 12 mm thick toughened glass, including edge polishing and decorative etching as required, used in hinged doors, partitions, automatic doors, and similar works, complete with all necessary fittings and fixtures such as stainless steel (SS) glass handles, SS studs, pivots, patch fittings, door locks, and all other accessories, complete all as specified and directed by Engineer-in-Charge. |
| 191 | S&F Roller venetian blinds type made out of standard cloth of approved texture with necessary accessories etc complete. |
| 192 | M&L 15 mm thick rendering in cement mortar 1:4 finished even and smooth without using extra cement including mixed with water proofing compound as per manufacturer instructions (WPC shall be measured and paid separately). |
| 193 | M & L Podium waterproofing system W159 SBS IN 1.5, a 1.5mm thick with modified bitumen waterproofing membrane with cross laminated HDPE film for wet application on the surfaces. The membrane shall be applied after making the surfaces dry conditionand applying a bonding slurryW1 IN. The membrane is then unrolledand pressed into the fresh slurry after removel of thereleaseliner. both lng and short edges of the membrance are overlapped by min 80mm and firmly pessed together using a roller with stagged overlaps. The membrance shall have a tensile strength-25 MPs according to ASTM D4-12; elengation 500% according to ASTM D412; resistance to static puncture-900N according to ASTM E154, adhesion in peel-1.N/mm according to ASTM D 903 mod, resistance to lateral water migration-71m according to ASTM D5385 mod. |
| 194 | M & L rendering 10 mm thick in cement mortar (1:3) on concrete surfaces as in ceiling, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 195 | M&L for applying two coats of oil emulsion distemper on newly plastered wall surfaces over and including a coat of primer and proper surface preparation, complete all as specified and directed by Engineer-in-Charge. |
| 196 | M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified and directed by Engineer-in-Charge. |
| 197 | M&L for complete preparation of old decorated wall surfaces and applying one coat of oil emulsion distemper, including minor repairs to surface irregularities, complete all as specified and directed by Engineer-in-Charge. |
| 198 | M&L for complete preparation of old decorated ceiling surfaces and applying one coat of oil emulsion distemper, including surface cleaning and minor repairs, complete all as specified and directed by Engineer-in-Charge. |
| 199 | Supply & fixing in repairs powder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 200 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings. |
| 201 | S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site. complete all as specified |
| 202 | S & F 12 mm thick prelaminated medium-density particle board, interior grade, prelaminated on both sides with decorative lamination of approved shade, fixed with screws to aluminium framework, complete all as specified and directed by Engineer-in-Charge. |
| 203 | Taking up or down existing GI water tubing, 15 mm bore, including all fittings, cleaning for refixing or removing to store, complete all as specified and directed by Engineer-in-Charge. |
| 204 | S & F UPVC pressure pipes, 15 mm bore, pressure rating 10 Kgf/cm², fixed complete to walls, ceilings, or laid in floors, with all necessary fittings, complete all as specified and directed by Engineer-in-Charge. |
| 205 | S & F UPVC pressure pipes, 25 mm bore, pressure rating 10 Kgf/cm², fixed complete to walls, ceilings, or laid in floors, with all necessary fittings, complete all as specified and directed by Engineer-in-Charge. |
| 206 | S & F plastic water closet seat, black or white, closed pattern with flat bottom and cover, complete with mild steel chromium-plated or aluminised hinging device, complete all as specified and directed by Engineer-in-Charge. |
| 207 | S & F in repair water closet, squatting pan (Orissa pattern), size 580 × 440 mm, white, with integral footrests, including connection to trap and flushing pipe with antisiphonage pipe, and making good the floor, excluding flushing cistern and flush pipe, complete all as specified and directed by Engineer-in-Charge. |
| 208 | S & F stainless steel sink with drainage board, fabricated from 1 mm thick stainless steel sheet, for kitchen use, complete with plug, washers, and waste pipe, including bedding in cement mortar to dwarf wall or fixing on cantilever brackets, and connecting union to pipe; overall size 915 × 460 mm and bowl size 410 × 330 × 160 mm, fixed in repair, complete all as specified and directed by Engineer-in-Charge. |
| 209 | S & F stainless steel sink fabricated from 1 mm thick stainless steel sheet for kitchen use, complete with plug, washers, and waste pipe, including bedding in cement mortar to dwarf wall or fixing on cantilever brackets, and connecting union to pipe; overall size 495 × 420 mm and bowl size 410 × 330 × 160 mm, fixed in repair, complete all as specified and directed by Engineer-in-Charge. |
| 210 | S & F in repair fancy type long shank bib cock, 15 mm dia, suitable for sink, screwed for iron pipe, fixed complete all as specified and directed by Engineer-in-Charge. |
| 211 | S & F in repair fancy type two-way bib cock, 15 mm dia, screwed for iron pipe, fixed complete all as specified and directed by Engineer-in-Charge. |
| 212 | S & F in repair fancy type angle valve, chromium-plated cast copper alloy, 15 mm bore, with crutch or butterfly handle, fixed complete all as specified and directed by Engineer-in-Charge. |
| 213 | Disconnecting existing water storage tanks exceeding 500 litres but not exceeding 1000 litres capacity, setting aside (or lowering if required) for cleaning, repairs, and hoisting if required, including reconnecting and refixing in position, cleaning and removing all scale, dirt, etc., from tank and mouths of circulating pipes, complete all as specified and directed by Engineer-in-Charge. |
| 214 | Disconnecting existing water storage tanks exceeding 1000 litres but not exceeding 2000 litres capacity, setting aside (or lowering if required) for cleaning, repairs, and hoisting if required, including reconnecting and refixing in position, cleaning and removing all scale, dirt, etc., from tank and mouths of circulating pipes, complete all as specified and directed by Engineer-in-Charge. |
| 215 | M & L for light-shade, double-charged vitrified ceramic tiles, 10 mm thick (square/rectangular), polished, area of each tile not exceeding 0.36 Sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid on and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), complete all as specified and directed by Engineer-in-Charge. |
| 216 | M & L for light-shade, double-charged vitrified ceramic tiles, 10 mm thick (square/rectangular), polished, area of each tile not exceeding 0.36 Sqm (600 × 600 mm), fixed on vertical surfaces such as skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10 mm thick rendering in cement mortar (1:3), complete all as specified and directed by Engineer-in-Charge. |
| 217 | M & L for 20 mm thick granite (of any type) work, table rubbed and polished, as in steps, jambs, pillars, window cills, cooking platforms, working tables, etc., laid over and including 20 mm thick screed bed in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite, complete all as specified and directed by Engineer-in-Charge. |
| 218 | Rounding to edges of stone slabs on edges, such as steps, cooking platforms, and similar work, including making grooves for lining, complete all as specified and directed by Engineer-in-Charge. |
| 219 | M & L for machine-cut mirror polished Kota stone slab flooring, 18 to 20 mm thick, as in steps, landings, and floors, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, mirror polishing, and 20 mm thick screed bed in cement mortar (1:4), complete all as specified and directed by Engineer-in-Charge. |
| 220 | M & L for machine-cut mirror polishedKota stone slabs, 18 to 20 mm thick, as in skirting/vertical surfaces, jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing, and 15 mm thick backing coat in cement mortar (1:4), complete all as specified and directed by Engineer-in-Charge. |
| 221 | Demolition and breaking up of drain pipes (salt glazed ware or reinforced cement concrete), 100 mm dia, set in cement mortar, including removal from site, complete all as specified and directed by Engineer-in-Charge. |
| 222 | Supply & Fixing in repairs 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 75 mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified |
| 223 | S & F PVC (SWR) bend, 75 mm bore, single socketed, any radius, suitable for PVC (SWR) pipe, fixed to walls or laid in floors, including necessary rubber ring joints and accessories, complete all as specified and directed by Engineer-in-Charge. |
| 224 | S & F PVC (SWR) vent cowl, 110 mm bore, fixed complete all as specified and directed by Engineer-in-Charge. |
| 225 | S & F PVC (SWR) vent cowl, 75 mm bore, fixed complete all as specified and directed by Engineer-in-Charge. |
| 226 | S & F aluminium extruded body door closer, hydraulically regulated, designation No. 1, universal type, suitable for door shutters up to 700 mm in width and of weight not exceeding 35 kg, fixed complete all as specified and directed by Engineer-in-Charge. |
| 227 | S&F 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall vertically with screws to make PVC frame as per specification and drawing |
| 228 | S&F PVC wall /ceiling paneling 7-8mm overall thickness consisting of 2mm thick coloured /designed PVC sheet, provided with grove and interlocking arrangement inclusive of solvent cement and fixing on PVC frame (PVC frame will measured and paid separately) as per specifications and drawing. |
| 229 | S&F decorative floor mat, tiles pattern (as per sample), laid dry in floors including stretching, cutting and fitting all as specified and |
| 230 | Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 Cu.m.getting out, returning. filling in and ramming earth or borekn rubble mixed with earth around, in layers not exceeding 25cm incl rubbish off the premises etc complete all as specified |
| 231 | M&L for cement concrete 1:3:6 type C-2 (40 mm aggregate) as in foundations, filling and mass cocrete etc complete all as specified and directed. |
| 232 | M & L Structural steel work as rolled sections as in posts, main and cross beams, hip and jack rafters. purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats, or other connecting plates, including screw bolts, nuts and MS plates etc all as specified and directed. by Engg-in-charge. |
| 233 | S&F 0.63mm thick Plain, mild steel sheet in hips, valley gutters, drips and straight flashings (length and girth as fixed) etc complete all as specified |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy