Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Work (PART \"A\") Construction of Proposed Observation Home at Vatsalya Sadan Budgam |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soils |
| 3 | P/L dry Stone Soling duly hand packed & consolidated with hand rammers incl.all carriage leads and lifts complete Job. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 mm nominal size) PCC below Foundation& rooms-Mudmat including carriage. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, including curing but excluding the cost of centering, shuttering, finishing and reinforcement.- All work upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level, upto floor five level including curing but excluding cost of centering, shuttering, finishing and reinforcement. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade M-15 excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Centring and shuttering including strutting, propping etc and removal of form work: |
| 10 | foundation,footings etc |
| 11 | Suspended floors, roofs, landings, balconies and access platform. |
| 12 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Stairs (excluding landings) except spiral staircases. |
| 14 | Edges of slabs and breaks in floors and walls |
| 15 | Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. TMT reinforcement of grade Fe-500D steel bars at all levels. |
| 16 | Supplying filling of watering compacting and dressing nallah muck under floors including all carriage lead lifts complete. |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 18 | Brick work with FPS bricks of class designation 75 in upto floor V-level in cement mortar 1:6 (1 cement : 6 coarse sand) etc complete job. |
| 19 | Half brickworkwith common burnt clay in superstructure, above floor V level for every four floors or part thereof by mechanical means in Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Kiln seasoned and chemically treated hollock wood incl. all carriages leads and lift complete job |
| 21 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, kiln dried imported/seasoned timber.35mm incl. all carriages leads and lift complete job |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Kiln seasoned & chemically treated imported wood incl. all carriages leads and lift complete job |
| 23 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 3.5 mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws 35 mm Kiln seasoned and chemically treated imported wood incl. all carriages leads and lift complete job |
| 24 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge of 35 mm kiln dried timber incl. all carriages leads and lift complete job |
| 25 | Providing and fixing with 3.5mm float glass including beading incl. all carriages leads and lift complete job |
| 26 | 12 mm cement plaster on rough side of brick wall in1:4(1 cement : 4 fine sand mortar) |
| 27 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 28 | 12 mm EXTERNAL cement plaster on rough side of single or half brick wall in1:4(1 cement : 4 fine sand mortar) of required design as per specifications provided by the consultant including necessary scaffolding arrangements |
| 29 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick incl. all carriages leads and lift complete job |
| 30 | Distempering with oil bound distemper of app brand and manufacture incl. all carriages leads and lift complete job |
| 31 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)etc incl. all carriages leads and lift complete job |
| 32 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works complete job (two coats) incl. all carriages leads and lift complete job |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on wood / steel works. |
| 34 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm) |
| 35 | Cement concrete Flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) with 20mm nominal size stone aggregate etc.complete job |
| 36 | Providing and fixing 1st quality ceramic glazed wall tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade incl. all carriages leads and lift complete job |
| 37 | VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm incl. all carriages leads and lift complete job |
| 38 | Providing and laying Marble stone flooring laid in required pattern in linear portion of the building all complete with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge incl. all carriages leads and lift of marbles complete job |
| 39 | Providing edge Double moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble Work |
| 40 | Structural steel work welded in built up section for trusses and framed work including cutting hoisting, fixing in position anchor bolts and applying a primer coat of approved steel primer.including carriage |
| 41 | Providing / Fixing pre coated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer incharge)0.50mm (+0.05%) total coated thickness with zinc coating 120 garms per sqm as per IS:277, in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet etc. incl ridges and valleys |
| 42 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position :in Budloo incl. all carriages leads and lift complete job |
| 43 | Providing and fixing 12 mm thick plywood board in partitions and ceilings excluding frame work but including all necessary hardware and fittings incl. all carriages leads and lift complete job |
| 44 | Providing and fixing plained eaves boarding.2nd class kail wood 250x32 mm (nominal size ) incl. all carriages leads and lift complete job |
| 45 | Providing and fixing M.S. railing of required pattern with M.S. square or round tubes,flats, built up or single sections as per the specifications provided by the consultantetc including priming coat with approved steel primer all complete including all carriage leads and lifts. |
| 46 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation, leveling and dressing and finishing the top smooth and curing complete |
| 47 | Providing dash fasteners/ iron hold fast 40x5mm flat 40cm long including fixing to frame with 10mm diameter bolts,nuts and wooden plugs and embedding in cement concrete blocl 30x10x15cm in 1:3:6 mix. incl. all carriages leads and lift complete job |
| 48 | Providing and fixing of Hardware fittings (Alloy) as per approved samples incl. all carriages leads and lift complete job |
| 49 | 100mm Handle |
| 50 | 150 mm Handle |
| 51 | 100mm Tower bolt |
| 52 | 150mm Tower bolts |
| 53 | Stay hooks |
| 54 | L drop 10\" |
| 55 | Sanitary |
| 56 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soils |
| 57 | P/L dry Stone Soling duly hand packed & consolidated with hand rammers incl.all carriage leads and lifts complete Job. |
| 58 | Providing and laying in position specified grades of reinforced cement concrete 1:1.5:3 in beams, slabs, walls(any thickness) including attached pillasters, buttresses, plinth and string courses, filets, columns, , stairs,pillars, piers, abutments, posts and struts etc. using 20mm thick crushed stone agg. Excluding the cost of centring, shuttering, finishing and reinforcement. All works upto the plinth level |
| 59 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) including carriage. |
| 60 | Centring and shuttering including strutting, propping etc and removal of form work: |
| 61 | Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. TMT reinforcement of grade Fe-500D steel bars at all levels.incl carriage |
| 62 | P/L of dry rubble masonry with hard stone in foundation and plinth incl. all carriages involved |
| 63 | 15 mm cement plaster on rough side of single or half brick wall in1:4(1 cement : 4 fine sand mortar) |
| 64 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete 25 mm thick with 20mm nominal size stone aggregate etc.complete job |
| 65 | Brick with FPS bricks of class designation 75 in in cement mortar 1:6 (1 cement : 6 coarse sand) etc complete job. |
| 66 | Providing and fixing 3 layer PP-R (Poly propylene Random co polymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 67 | 25 mm OD Pn20 |
| 68 | 40 mm OD Pn20 |
| 69 | 50 mm OD Pn20 |
| 70 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes Pn20, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. External work including trenching, refilling etc |
| 71 | pipe 25mm |
| 72 | PPR Union 25mm |
| 73 | PPR Union 40mm |
| 74 | PPR Union 50mm |
| 75 | PPR Adapter 25mm |
| 76 | PPR Adapter 40mm |
| 77 | PPR Adapter 50mm |
| 78 | a) 25mm dia OD |
| 79 | BALL VALVE TANK 25MM |
| 80 | b) 40 mm dia OD |
| 81 | BALL VALVE TANK 40MM |
| 82 | b) 50 mm dia OD |
| 83 | BALL VALVE TANK 50MM |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 85 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 86 | Providing and fixing 15 mm nominal bore C.P. brass angle valve approved quality conforming to IS : 8931 |
| 87 | P/F CP long brass wall mixer of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 88 | P/F CP brass Double lever wall mixer with concealed shower of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 89 | Providing and fixing CP Brass shower rose including arm and Flange with 15 or 20 mm inlet 100mm Shower |
| 90 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 91 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of two urinal basins with 5 literwhite P.V.C automatic flushing cistern. |
| 92 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 93 | P/F white vitreous china pedestal for wash basin complete rested at back for the reception of pipe and fittings |
| 94 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510mm bowl depth 200mm |
| 95 | P/F Cp waste 32mm including waste pipe and all fixtures. |
| 96 | P/F 8mm dia C.P/S.S jet with flexible tube up to 1mter long with S.S triangular plate to European type W.C of approved quality and make. |
| 97 | P/F of bevelled edge mirror of superior glass of approved quality complete fixed to PVC rawl plug with C P Brass screws complete job |
| 98 | P/F of 600 x 120x5 mm glass shelf with edges round of supported on anodised aluminium angle frame with C P Brass bracket and guard rail fixed with 40 mm long screws complete job |
| 99 | P/F in position PVC floor traps |
| 100 | 100mm |
| 101 | P/F soil, waste and vent pipes of medium Class |
| 102 | a)PVC S&S pipe (150mm dia) |
| 103 | a)PVC S&S pipe (100mm dia) |
| 104 | c)PVC S&S pipe (75mm dia) |
| 105 | d)PVC S&S pipe (50mm dia) |
| 106 | PVC Cowell 50/75 mm dia |
| 107 | P/F PVC stay and clamps for PVC pipes |
| 108 | a) 100mm |
| 109 | b) 75mm |
| 110 | P/F bend of required degree with door, inspection rubber washer 3mm thick, bolts and nuts complete PVC S&S pipes appropriate class |
| 111 | a) 100mm |
| 112 | b) 75mm |
| 113 | P/F plain bend of standard make |
| 114 | a) 100mm |
| 115 | b) 75mm |
| 116 | c)50mm |
| 117 | P/F T Junction of standard make |
| 118 | a) 100mm |
| 119 | b) 75mm |
| 120 | P/F Door T junction of standard make |
| 121 | a)100mm |
| 122 | a)75mm |
| 123 | P/F PVC Reducer 100-50mm dia |
| 124 | P/F PVC Reducer 100-75mm dia |
| 125 | PVC Collar 100mm |
| 126 | PVC Collar 75mm |
| 127 | Providing and fixing CP soap case of approved quality |
| 128 | Providing and fixing C.P / Stainless steel anti cockroach trap (grating) on floortraps and floor drains with cement mortar, complete in all respects. |
| 129 | Providing & fixing of 15mm dia PVC connection 600mm long including endunion and washers complete. |
| 130 | Constructing brick masonry chamber for underground PIPES inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :.Inside dimensions as per requirement mm for singlepipe line with one or two inlets |
| 131 | P/F master trap |
| 132 | 2 HP Motor of standard make including fixing |
| 133 | Hot water geyser of standard make 50 Liter |
| 134 | Carriage of Stone Soling For an average lead of 35kms |
| 135 | Carriage of Bricks For an average lead of 7kms |
| 136 | Carriage of Sand For an average lead of 40kms |
| 137 | Carriage of Aggregate for an average lead of 7km |
| 138 | Carriage of Stones for an average lead of 10km |
| 139 | Electrification |
| 140 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /RR Kabels /Anchor /Salzer make to be approved by EIC before installation. in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and allied accessories like bends .lighting conceal deeps and fan deeps etc ) , with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Simens make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+E for Normal and invertor points per room is to be provided seperately).The Job further includes providing and fixing of heavy duty Metallic conceled deeps and Fan junction deeps of standard make dully isi marked (to be approved by EIC before installation) actual numbers to be provided as per site requirement and as per instructions of EIC complete job |
| 141 | Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLs PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires of Polycab/Finolex /Anchor/ RR Cabels /Salzer make to be approved by EIC before installation. , to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ).The Job further Includes supply and fixing modular grid plate mounted flush mounted 2 no 240 volts 6-16 Amp 5 pin socket out let along with 2 No\"s of 6-16 Amp control Switch to be housed in 6-Way heavy duty GI Modular Box with modular cover plate of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make , complete as per specification and as required . The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and wires |
| 142 | Point wiring for 16 Amp Socket out lets with 3x4 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/RR Cabels /Salzer make to be approved by EIC before installation. , to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ) .The job further includes the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make to be housed in heavy duty 4-Modular GI Box of same make as of switches /sockets with p/f of modular cover plate , complete as per specification and as required with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and wires |
| 143 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits for housing of upto 4 Sq.mm wires and 32 mm dia for housing of above 4 Sq.mm wires including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) as required. of Polycab / Finolex /Anchor / RR Kabels /Salzer make to be approved by EIC before installation. . |
| 144 | 2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire |
| 145 | 2 X4 sq. mm + 1 X4 sq. mm earth wire |
| 146 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 147 | 2 X 10 sq. mm +1 X 6 sq. mm earth wire |
| 148 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 149 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 150 | Supply and fixing of Indicators (Modular type) fitted on modular grid plate and GI Boxes complete job |
| 151 | Supply and laying of 19-25 mm dia medium class PVC medium grade Conduit to be laid on surface with screws fixed in rowel plugs complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area\"s.Anchor/Polycab/Finolex/TMT Plus make. |
| 152 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required.of Usha / Crompton Greaves / Orient /Helonix to be approved by EIC before installation. |
| 153 | Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Orient /Helonix to be approved by EIC before installation. incl making of necessary connections and making of necessary space in walls / Windows as per site. |
| 154 | Supply, Installation, Testing and commissioning of 12 watt LED surface/recessed Down lighters having CRCA /Aluminium Body ,minimum lumens 100 lm/w (commercial type) ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of make incl making of necessary Connections. ). The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. of Wipro/ Helonix /Jaguar /Trulux / Crompton make to be approved by EIC before installation. |
| 155 | Supply ,installation ,Testing and Commissioning of 10-12 Watts ,2 ft long LED tube light fitting having PVC Body (Commercial type) of Wipro/ Helonix /Jaguar /Trulux / Crompton make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job. |
| 156 | Supply, Installation, Testing and commissioning of 50 Watts LED flood lighting luminaries having CRCA /Aluminium Body ,minimum lumens 100 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of Wipro/ Helonix /Jaguar /Trulux / Crompton make make incl making of necessary Connections. The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of one years reckoned from date of successful commissioning /handing over of site to intending department. |
| 157 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections. |
| 158 | 6 way (4 + 18), Double door |
| 159 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make |
| 160 | Supplying and fixing of 32 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections. |
| 161 | Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 162 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections |
| 163 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 250 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based of Legrend /Schinder /Simens / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 400 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 40 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 400 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer 100 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no200 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (3) Generator Incommer 125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 1 No 200 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (4) Outgoing .100 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No 63 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 4 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear\"s and Drawing\"s of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 164 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 165 | 3 1/2 X 185 sq.mm(57 mm) for Normal Supply Cable |
| 166 | 3 1/2 X 70 sq.mm(38 mm) for Generator Supply Cable |
| 167 | Supply,Laying,Testing & Commissioning of 95 sq.mm 3.5- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 168 | Supply,Laying,Testing & Commissioning of 70 sq.mm 3.5- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 169 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 170 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 171 | PART \"B\" (Civil Work) Construction of Proposed Special Home at Vatsalya Sadan Budgam |
| 172 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soils |
| 173 | P/L dry Stone Soling duly hand packed & consolidated with hand rammers incl.all carriage leads and lifts complete Job. |
| 174 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 mm nominal size) PCC below Foundation& rooms-Mudmat including carriage. |
| 175 | Providing and laying in position specified grade of reinforced cement concrete, including curing but excluding the cost of centering, shuttering, finishing and reinforcement.- All work upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 176 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level, upto floor five level including curing but excluding cost of centering, shuttering, finishing and reinforcement. |
| 177 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 178 | Providing and laying in position cement concrete of specified grade M-15 excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 179 | Centring and shuttering including strutting, propping etc and removal of form work: |
| 180 | Footings foundations, bases of column |
| 181 | Suspended floors, roofs, landings, balconies and access platform. |
| 182 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 183 | Stairs (excluding landings) except spiral staircases. |
| 184 | Edges of slabs and breaks in floors and walls |
| 185 | Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. TMT reinforcement of grade Fe-500D steel bars at all levels. |
| 186 | Supplying filling of watering compacting and dressing nallah muck under floors including all carriage lead lifts complete. |
| 187 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 188 | Brick work with FPS bricks of class designation 75 in upto floor V-level in cement mortar 1:6 (1 cement : 6 coarse sand) etc complete job. |
| 189 | Half brickworkwith common burnt clay in superstructure, above floor V level for every four floors or part thereof by mechanical means in Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 190 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Kiln seasoned and chemically treated hollock wood incl. all carriages leads and lift complete job |
| 191 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, kiln dried imported/seasoned timber.35mm incl. all carriages leads and lift complete job |
| 192 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Kiln seasoned & chemically treated imported wood incl. all carriages leads and lift complete job |
| 193 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 3.5 mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws 35 mm Kiln seasoned and chemically treated imported wood incl. all carriages leads and lift complete job |
| 194 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge of 35 mm kiln dried timber incl. all carriages leads and lift complete job |
| 195 | Providing and fixing with 3.5mm float glass including beading incl. all carriages leads and lift complete job |
| 196 | 12 mm cement plaster on rough side of brick wall in1:4(1 cement : 4 fine sand mortar) |
| 197 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 198 | 12 mm EXTERNAL cement plaster on rough side of single or half brick wall in1:4(1 cement : 4 fine sand mortar) of required design as per specifications provided by the consultant including necessary scaffolding arrangements |
| 199 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick incl. all carriages leads and lift complete job |
| 200 | Distempering with oil bound distemper of app brand and manufacture incl. all carriages leads and lift complete job |
| 201 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)etc incl. all carriages leads and lift complete job |
| 202 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works complete job (two coats) incl. all carriages leads and lift complete job |
| 203 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on wood / steel works. |
| 204 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm) |
| 205 | Cement concrete Flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) with 20mm nominal size stone aggregate etc.complete job |
| 206 | Providing and fixing 1st quality ceramic glazed wall tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade incl. all carriages leads and lift complete job |
| 207 | VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm incl. all carriages leads and lift complete job |
| 208 | Providing and laying Marble stone flooring laid in required pattern in linear portion of the building all complete with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge incl. all carriages leads and lift of marbles complete job |
| 209 | Providing edge Double moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble Work |
| 210 | Structural steel work welded in built up section for trusses and framed work including cutting hoisting, fixing in position anchor bolts and applying a primer coat of approved steel primer.including carriage |
| 211 | Providing / Fixing pre coated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer incharge)0.50mm (+0.05%) total coated thickness with zinc coating 120 garms per sqm as per IS:277, in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet etc. incl ridges and valleys |
| 212 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position :in Budloo incl. all carriages leads and lift complete job |
| 213 | Providing and fixing 12 mm thick plywood board in partitions and ceilings excluding frame work but including all necessary hardware and fittings incl. all carriages leads and lift complete job |
| 214 | Providing and fixing plained eaves boarding.2nd class kail wood 250x32 mm (nominal size ) incl. all carriages leads and lift complete job |
| 215 | Providing and fixing M.S. railing of required pattern with M.S. square or round tubes,flats, built up or single sections as per the specifications provided by the consultantetc including priming coat with approved steel primer all complete including all carriage leads and lifts. |
| 216 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation, leveling and dressing and finishing the top smooth and curing complete |
| 217 | Providing dash fasteners/ iron hold fast 40x5mm flat 40cm long including fixing to frame with 10mm diameter bolts,nuts and wooden plugs and embedding in cement concrete blocl 30x10x15cm in 1:3:6 mix. incl. all carriages leads and lift complete job |
| 218 | Providing and fixing of Hardware fittings (Alloy) as per approved samples incl. all carriages leads and lift complete job |
| 219 | 100mm Handle |
| 220 | 150 mm Handle |
| 221 | 100mm Tower bolt |
| 222 | 150mm Tower bolts |
| 223 | Stay hooks |
| 224 | L drop 10\" |
| 225 | Sanitary |
| 226 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soils |
| 227 | P/L dry Stone Soling duly hand packed & consolidated with hand rammers incl.all carriage leads and lifts complete Job. |
| 228 | Providing and laying in position specified grades of reinforced cement concrete 1:1.5:3 in beams, slabs, walls(any thickness) including attached pillasters, buttresses, plinth and string courses, filets, columns, , stairs,pillars, piers, abutments, posts and struts etc. using 20mm thick crushed stone agg. Excluding the cost of centring, shuttering, finishing and reinforcement. All works upto the plinth level |
| 229 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) including carriage. |
| 230 | Centring and shuttering including strutting, propping etc and removal of form work: |
| 231 | Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. TMT reinforcement of grade Fe-500D steel bars at all levels.incl carriage |
| 232 | P/L of dry rubble masonry with hard stone in foundation and plinth incl. all carriages involved |
| 233 | 15 mm cement plaster on rough side of single or half brick wall in1:4(1 cement : 4 fine sand mortar) |
| 234 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete 25 mm thick with 20mm nominal size stone aggregate etc.complete job |
| 235 | Brick with FPS bricks of class designation 75 in in cement mortar 1:6 (1 cement : 6 coarse sand) etc complete job. |
| 236 | Providing and fixing 3 layer PP-R (Poly propylene Random co polymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 237 | 25 mm OD Pn20 |
| 238 | 40 mm OD Pn20 |
| 239 | 50 mm OD Pn20 |
| 240 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes Pn20, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. External work including trenching, refilling etc |
| 241 | pipe 25mm |
| 242 | PPR Union 25mm |
| 243 | PPR Union 40mm |
| 244 | PPR Union 50mm |
| 245 | PPR Adapter 25mm |
| 246 | PPR Adapter 40mm |
| 247 | PPR Adapter 50mm |
| 248 | a) 25mm dia OD |
| 249 | BALL VALVE TANK 25MM |
| 250 | b) 40 mm dia OD |
| 251 | BALL VALVE TANK 40MM |
| 252 | b) 50 mm dia OD |
| 253 | BALL VALVE TANK 50MM |
| 254 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 255 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 256 | Providing and fixing 15 mm nominal bore C.P. brass angle valve approved quality conforming to IS : 8931 |
| 257 | P/F CP long brass wall mixer of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 258 | P/F CP brass Double lever wall mixer with concealed shower of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 259 | Providing and fixing CP Brass shower rose including arm and Flange with 15 or 20 mm inlet 100mm Shower |
| 260 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 261 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of two urinal basins with 5 literwhite P.V.C automatic flushing cistern. |
| 262 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 263 | P/F white vitreous china pedestal for wash basin complete rested at back for the reception of pipe and fittings |
| 264 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510mm bowl depth 200mm |
| 265 | P/F Cp waste 32mm including waste pipe and all fixtures. |
| 266 | P/F 8mm dia C.P/S.S jet with flexible tube up to 1mter long with S.S triangular plate to European type W.C of approved quality and make. |
| 267 | P/F of bevelled edge mirror of superior glass of approved quality complete fixed to PVC rawl plug with C P Brass screws complete job |
| 268 | P/F of 600 x 120x5 mm glass shelf with edges round of supported on anodised aluminium angle frame with C P Brass bracket and guard rail fixed with 40 mm long screws complete job |
| 269 | P/F in position PVC floor traps |
| 270 | 100mm |
| 271 | P/F soil, waste and vent pipes of medium Class |
| 272 | a)PVC S&S pipe (150mm dia) |
| 273 | a)PVC S&S pipe (100mm dia) |
| 274 | c)PVC S&S pipe (75mm dia) |
| 275 | d)PVC S&S pipe (50mm dia) |
| 276 | PVC Cowell 50/75 mm dia |
| 277 | P/F PVC stay and clamps for PVC pipes |
| 278 | a) 100mm |
| 279 | b) 75mm |
| 280 | P/F bend of required degree with door, inspection rubber washer 3mm thick, bolts and nuts complete PVC S&S pipes appropriate class |
| 281 | a) 100mm |
| 282 | b) 75mm |
| 283 | P/F plain bend of standard make |
| 284 | a) 100mm |
| 285 | b) 75mm |
| 286 | c)50mm |
| 287 | P/F T Junction of standard make |
| 288 | a) 100mm |
| 289 | b) 75mm |
| 290 | P/F Door T junction of standard make |
| 291 | a)100mm |
| 292 | a)75mm |
| 293 | P/F PVC Reducer 100-50mm dia |
| 294 | P/F PVC Reducer 100-75mm dia |
| 295 | PVC Collar 100mm |
| 296 | PVC Collar 75mm |
| 297 | Providing and fixing CP soap case of approved quality |
| 298 | Providing and fixing C.P / Stainless steel anti cockroach trap (grating) on floortraps and floor drains with cement mortar, complete in all respects. |
| 299 | Providing & fixing of 15mm dia PVC connection 600mm long including endunion and washers complete. |
| 300 | Constructing brick masonry chamber for underground PIPES inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :.Inside dimensions as per requirement mm for single pipe line with one or two inlets |
| 301 | P/F master trap |
| 302 | 2 HP Motor of standard make including fixing |
| 303 | Hot water geyser of standard make 50 liters |
| 304 | Carriage of soling For an average lead of 35 kms |
| 305 | Carriage of Bricks For an average lead of 7kms |
| 306 | Carriage of Sand For an average lead of 40kms |
| 307 | Carriage of 40mm Aggregate for an average lead of 7km |
| 308 | Carriage of Stones for an average lead of 10km |
| 309 | Electrification |
| 310 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /RR Kabels /Anchor /Salzer make to be approved by EIC before installation. in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and allied accessories like bends .lighting conceal deeps and fan deeps etc ) , with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Simens make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+E for Normal and invertor points per room is to be provided seperately).The Job further includes providing and fixing of heavy duty Metallic conceled deeps and Fan junction deeps of standard make dully isi marked (to be approved by EIC before installation) actual numbers to be provided as per site requirement and as per instructions of EIC complete job |
| 311 | Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLs PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires of Polycab/Finolex /Anchor/ RR Cabels /Salzer make to be approved by EIC before installation. , to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ).The Job further Includes supply and fixing modular grid plate mounted flush mounted 2 no 240 volts 6-16 Amp 5 pin socket out let along with 2 No\"s of 6-16 Amp control Switch to be housed in 6-Way heavy duty GI Modular Box with modular cover plate of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make , complete as per specification and as required . The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and wires |
| 312 | Point wiring for 16 Amp Socket out lets with 3x4 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/RR Cabels /Salzer make to be approved by EIC before installation. , to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ) .The job further includes the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make to be housed in heavy duty 4-Modular GI Box of same make as of switches /sockets with p/f of modular cover plate , complete as per specification and as required with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and wires |
| 313 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits for housing of upto 4 Sq.mm wires and 32 mm dia for housing of above 4 Sq.mm wires including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) as required. of Polycab / Finolex /Anchor / RR Kabels /Salzer make to be approved by EIC before installation. . |
| 314 | 2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire |
| 315 | 2 X4 sq. mm + 1 X4 sq. mm earth wire |
| 316 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 317 | 2 X 10 sq. mm +1 X 6 sq. mm earth wire |
| 318 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 319 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 320 | Supply and fixing of Indicators (Modular type) fitted on modular grid plate and GI Boxes complete job |
| 321 | Supply and laying of 19-25 mm dia medium class PVC medium grade Conduit to be laid on surface with screws fixed in rowel plugs complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area\"s.Anchor/Polycab/Finolex/TMT Plus make. |
| 322 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required.of Usha / Crompton Greaves / Orient /Helonix to be approved by EIC before installation. |
| 323 | Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Orient /Helonix to be approved by EIC before installation. incl making of necessary connections and making of necessary space in walls / Windows as per site. |
| 324 | Supply, Installation, Testing and commissioning of 12 watt LED surface/recessed Down lighters having CRCA /Aluminium Body ,minimum lumens 100 lm/w (commercial type) ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of make incl making of necessary Connections. ). The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. of Wipro/ Helonix /Jaguar /Trulux / Crompton make to be approved by EIC before installation. |
| 325 | Supply ,installation ,Testing and Commissioning of 10-12 Watts ,2 ft long LED tube light fitting having PVC Body (Commercial type) of Wipro/ Helonix /Jaguar /Trulux / Crompton make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job. |
| 326 | Supply, Installation, Testing and commissioning of 50 Watts LED flood lighting luminaries having CRCA /Aluminium Body ,minimum lumens 100 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of Wipro/ Helonix /Jaguar /Trulux / Crompton make make incl making of necessary Connections. The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of one years reckoned from date of successful commissioning /handing over of site to intending department. |
| 327 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections. |
| 328 | 6 way (4 + 18), Double door |
| 329 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make |
| 330 | Supplying and fixing of 32 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections. |
| 331 | Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 332 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections |
| 333 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 250 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based of Legrend /Schinder /Simens / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 400 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 40 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 400 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer 100 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no200 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (3) Generator Incommer 125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 1 No 200 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (4) Outgoing .100 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No 63 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 4 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear\"s and Drawing\"s of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 334 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 160 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based of Legrend /Schinder /Simens / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 200 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 400 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer 63 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no200 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (3) Generator Incommer 100 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 1 No 200 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT\"s of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No\"s (3 No\"s) phase indication lamps and 3 No.\"s status indication lamp for ON / OFF /TRIP with Control SP MCB (4) Outgoing .63Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No 40 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No32 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 4 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear\"s and Drawing\"s of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. for Special Home |
| 335 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 336 | 3 1/2 X 185 sq.mm(57 mm) for Normal Supply Cable |
| 337 | 3 1/2 X 70 sq.mm(38 mm) for Generator Supply Cable |
| 338 | Supply,Laying,Testing & Commissioning of 95 sq.mm 3.5- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 339 | Supply,Laying,Testing & Commissioning of 70 sq.mm 3.5- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 340 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 341 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail