Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Earthwork in hard soil in filling road site drain & flank cutting with all leads and lifts including breaking the clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30 mtrs in depth leveling dressing the bed and removing all foreign materials including roots, brushes and depositing the soil in layers and rolling, with PRR for ordinary compaction as directed by the Engineer-In-Charge. |
| 3 | Filling in foundation trenches and plinth with sand well watered and rammed in layers not exceeding 23cm. in depth with all leads and lifts including cost, conveyance, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 4 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm. size hard black hand broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete, watering and curing etc. complete to required levels laid in layers not exceeding 15cm (6 Inch) thick including cost, conveyance, royalties and taxes of all materials and cost of all labours, watering and curing, sundries and T&P required for the work etc. complete as directed by Engineer-in-charge. |
| 5 | Reinforced cement concrete of M-20 grade having a minimum compressive strength of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 20 mm. size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 4 (Four) weeks, centring, shuttering and finishing the exposed surface smooth, providing grooves and beeds where necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, required for the work etc. complete but excluding cost and conveyance of M.S. rods or Tor steel and binding wires of 18 to 20 gauge and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel tying the grills and placing in in proper position in all floors as directed by the Engineer in charge. |
| 6 | Column Footing |
| 7 | Column Superstructure |
| 8 | Plinth Bend |
| 9 | Lintel |
| 10 | Roof Beam |
| 11 | Chajja |
| 12 | Shelves |
| 13 | Roof Slab |
| 14 | Supplying, Cutting, Straightening coiled or bent up M.S. rods or Tor steel of JINDAL / SAIL welding or jointing if necessary, bending, binding, tying the grills and laying in position as required for R.C.C. works and hoisting, lowering and placing in position in all floors according to approved designs and drawings including cost, conveyance, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, etc. complete in all respect as directed by the Engineer-in-charge. |
| 15 | Fly Ash Brick masonry in cement mortar (1:6) in foundation & plinth using Flay Ash bricks of 23cm x11cm x 8cm size having a crushing strength not less than 75Kg per Sq.Cm, including splays cutting, circular moulding, chamfering, corbelling, watering and curing including cost, conveyance, royalties, taxes of all materials and labour with T & P required for the work etc. complete in all respect in all floors. |
| 16 | Fly ash Brick masonry in cement mortar (1:6) in superstructure using fly ash bricks of 23cm x11cm x 8cm size having a crushing strength not less than 75kg per Sq.Cm, including splays cutting, circular moulding, chamfering, corbelling & similar such type of works with all necessary projections. watering and curing for 7 days immersing the brick in water for six hours before use etc. complete including cost, conveyance, royalties, taxes of all materials and labour with T & P required for the work etc. complete in all respect in all floors. |
| 17 | Fly Ash brick masonry in cement mortar (1:4) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge |
| 18 | 12mm.(1/2 Inch) thick cement plaster (1:6) finished smooth to brick work after racking out joints including watering and curing , cost, conveyance, royalties and taxes of all materials, labour with T & P required for the work etc . complete in all respect in all floors. |
| 19 | 16mm.(5/8 Inch) thick cement plaster (1:6) finished smooth to brick work after racking out joints including watering and curing, cost, conveyance, royalties and taxes of all materials, labour with T & P required for the work etc. complete in all respect in all floors. |
| 20 | Providing 6mm thick cement plaster (1:4) to ply ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts including roughening, scraping, cleaning, finishing the plastered surface, watering and curing , cost, conveyance, royalties and taxes of all materials, labour with T & P required for the work etc. complete in all respect in all floors. |
| 21 | Supplying, fitting and fixing of vetrified tiles of premium grade having thickness 8mm to 10mm of 60Cm x 60Cm plain size (Homogenous) in floors, treads or steps and landing on 25mm thick bed of cement mortar, cement and sand (1:1) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including cost, conveyance, royalties and taxes of all materials with labour, T&P required for the work etc. complete in all respect in all floors as directed by the Engineer-In-Charge |
| 22 | Supplying, fitting and fixing of ceramic tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of 30Cm x 20Cm / 20Cm x 20 Cm size special plain in dados, skirting and rises of steps on 12mm thick cement plaster 1:3 (1 Cement : 3 Sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including cost, conveyance, royalties and taxes of all materials with labour, T&P required for the work etc. complete in all respect in all floors as directed by the Engineer-In-Charge |
| 23 | Providing & laying granite stone flooring using 20mm thick granite stone slab of approved quality, colour and size between 0.4 Sqm. to 1.0 Sqm. & above in staircase treads and risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, taxes, royalties, loading and unloading etc. complete as per direction of the Engineer-In-Charge. |
| 24 | Priming one coat to wall surface using water bound cement primer including cost, conveyance, taxes of all materials paint labour T&P etc complete in all respect. |
| 25 | Finishing wall surfaces with acrylic wall putty (water based) of approved make and finished smooth to receive painting including cost of scaffolding, staging charges with cost & conveyance of all materials taxes labour T & P etc complete as directed by Engineer-In-Charges. |
| 26 | Wall painting two coats with plastic emulsion paint of approved shade on new work to give and even shade including cost, conveyance, taxes of all materials paint labour T&P etc complete in all respect. |
| 27 | Painting two coats with weather seal coat after cleaning the surface including cost, conveyance, taxes of all materials, cost of all labour with T & P etc required for the work etc complete in all respect. |
| 28 | Supplying, fitting and fixing of M.S. Grills for window and gate M.S.Door with angle iron frame of approved design in proper position and making good to the damages to wall or R.C.C. Structure including mending or cutting to sizes or grooves in walls and fixing with C.C (1:2:4) with cost, conveyance, royalities and taxes of all materials with all labour, T&P required etc complete in all floors. |
| 29 | M.S. Grill |
| 30 | M.S. Pipe |
| 31 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. Center to Center and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials labour, T & P etc required for the work complete in all respect as directed by the Engineer in charge. |
| 32 | Supplying, fitting and fixing of flush door & shutter (3 Feet-7 Inch x 6 Feet-7 Inch size) of 32mm thick both side fitted with 4mm thick decorative veneers with brass fittings like hinges, motish lock, automatic door closer, door stopper etc complete including all cost, conveyance and taxes of all materials, labour with T & P etc required for the work complete as directed by the Engineer-In-Charge. |
| 33 | Factory made FRP (Alternately called GRP) Door with frame of size 75mmx100mm fabricated using E-Glass chopped standard Mat (CSM) U.V. Stabilised Inopthalic Gel Coat at impregnated with Inopthalic resin. The thickness of the GRP Skins shall not be less than 2.00mm. The door frame consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. Etc. complete excluding GST as directed by the Engineer-In-Charge. |
| 34 | Supplying, fitting and fixing in position dressed and well seasoned salwood work framed and fixed (Wrought and put up) in choukaths (0 Feet 3 Inch x 0 Feet 4 Inch) size for doors, windows and ventilators including cost of iron work and coal tarring 2 Coats, to wall side faces of choukaths including cost of coal tar, cutting grooves and mending to size where necessary with cost, conveyance, royalities, taxes of all materials and labour with T&P reauired for the work etc. complete in all respect in all floors as directed by the E.I.C. |
| 35 | Supply and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Casement Window with top fixed - 60- Series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement of Window Sash Profile and 74mm x 60mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site with 10 years manufactures warranty for discoloration, wraping, mechanical failures, shrinkages, rotting, corrosion etc. with a quality certificate from relevant department of Govt. of India, including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site with templates for casement sizing complete for finished item of work (structural requirements profiles are to be got approved by the Engineer-in-Charge of the work before fabrication of the shutter) as per specification and direction of the Engineer-in-Charge. Confirming to ASTM D 638-14, EN-477-95 and other applicable standards. |
| 36 | Supply and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Three Track - Three Panel Sliding Window - 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and Window Sash of 39mm x 58mm x 2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site with 10 years manufactures warranty for discoloration, wraping, mechanical failures, shrinkages, rotting, corrosion etc. with a quality certificate from relevant department of Govt. of India, including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site with templates for casement sizing complete for finished item of work (structural requirements profiles are to be got approved by the Engineer-in-Charge of the work before fabrication of the shutter) as per specification and direction of the Engineer-in-Charge. Confirming to ASTM D 638-14, EN-477-95 and other applicable standards. |
| 37 | Supply and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Ventilator / top hung-60- series duly manufactured using UPVC Reinforced profiles 60x55x2.5mm for outer frames, 75x60x2.58mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanized upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash fixed with EPDM weathering seal resistant accessories like clipping locking sstem made of aluminium 1 No. per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards. |
| 38 | Providing enamel painting two coat over a coat of primer to wood or iron work including cost, conveyance, taxes of all materials, cost of all labour with T & P etc required for the work etc complete in all respect as directed by the Engineer in charge. |
| 39 | 2.5Cm.(1Inch) thick grading concrete with cement (1:2:2) using 6mm & downgraded size over roof slab to proper slope finished smooth, watering and curing including cost, conveyance, taxes and royalties of all materials and labour with T&P required for the work etc. complete in all respect in all floors. |
| 40 | Back filling of Surplus excavated earth at work site by initial lead of 50.00 mtr and initial lift of 1.50 mtr including cost of all labour T&P required for the work etc. complete as directed by the Engineer-In-Charge. |
| 41 | Providing, supplying, diluting & injecting chemical emulsion for existing building anti termite treatment to both side below masonry walls existing floor points of contact of wood work by chlorpyriphos specification including drilling and plugging holes at 300mm centre to walls with making good to the holes with C.M. (1:4) after treatment including cost of all materials, labour T&P Required for the work as IS 6313 (Part-3)-2001 (Second Revision) Complete. |
| 42 | E.I. Works |
| 43 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. |
| 44 | Group A |
| 45 | Group B |
| 46 | Group C |
| 47 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 48 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 49 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 50 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 51 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 01 no of 2 nos 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 52 | 1x1.5mm2 for inverter wiring |
| 53 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit(2X1.5+1X1.5) |
| 54 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 55 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit . (2X4+1X1.5) |
| 56 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 1.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X4+2X1.5)(UPS BDB) |
| 57 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 58 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6) |
| 59 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 60 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 61 | Sub-Head II (Light fitting Fixture & Fan) |
| 62 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 63 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery Greater or Equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 64 | Supplying an fixing of recess/surface mounted 2\"x2\" 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 65 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 66 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 67 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 68 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 69 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 70 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,UPS DB,PDB) |
| 71 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR ups Outgoing DB)Warranty on DB is 3 years |
| 72 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 73 | Supplying and fixing 40Amps 4P 415 volts, MCB,C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 74 | Supplying and fixing 40 Amps rating,4P 440V, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 75 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 76 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 77 | Supplying and fixing 16Amps 4P 415 volts, MCB,C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 78 | Supplying and fixing 16 Amps rating,4P 440V, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 79 | (Earthing) INSTALLATION |
| 80 | Supplying,installation,testing & commissioning of materials and installation ofcopper earth plate 600mmx600mmx3.18mm thick ISI marked with copper nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 81 | Providing and fixing 25mm x 5 mm Copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 82 | Supply and making brick massonary pedastal with extra super structure including cement plastering with EARTH PIT Written on1.5x1.5 flat GI Plate chanel attached with rod as required as per direction of Engineer-in-charge. |
| 83 | CABLING AND END TERMINATION MAIN AREA |
| 84 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 85 | 3.5core x 70 sq mm (1 run from Pole to Main LT Panel 1 RUN FOR Back up) |
| 86 | LAYING OF CABLE |
| 87 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 88 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 89 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 90 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 91 | 3.5 core x70 sq mm |
| 92 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 93 | 200 mm dia |
| 94 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor and earthing as required.Make-Bajaj/philips /wipro/JAQUAR /halonix/k lite/ Eq. |
| 95 | Supply & fixing of LED 70w High bay Light similar to jaquar cat no-LHBLD1S070XC / Equivalent. etc as required .The luminaire to be installed in 6 mtr long GI hot dip galvanized pole as per direction of engineer in charge. |
| 96 | PANEL |
| 97 | MAIN PANEL with 100 A 4P Change over Switch ,160 A 4P MCCB 36 KA -01 No as incomer,63A 4P MCCB 25 KA -02 Nos, 63 A DP MCB 10KA-2 Nos,32A DP MCB 10KA-1 No,20A DP MCB 10KA-2 Nos,10 A SP MCB 10 KA-2 Nos with E.C Busbars etc as direction of engineer-in-charge. (Make -L&T,Legrand/Simens) |
| 98 | Supply ,Installation ,Testing and Commission of Inverter, Cruze UPS 2KVA-24V( make - luminous/ Exide/Microtec) |
| 99 | Supply,Installation,Testing and Commission of Inverter Battery 12V 150AH ( make -Exide/ Luminous) |
| 100 | Supply of Inverter stand (make-Microtech /Luminous) |
| 101 | P.H. Works |
| 102 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
| 103 | 20mm dia PVC pipe(sch-80) |
| 104 | 25mm dia PVC pip((sch-80) |
| 105 | 32mm dia PVC pipe(sch-80) |
| 106 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.((Plaza/Hindware/Cera) make. |
| 107 | 15mm dia CP angle stop cock |
| 108 | 15mm dia CP Two way bib cock |
| 109 | 15mm dia CP SB bib cock |
| 110 | 15mm dia CP long Body bib cock |
| 111 | 15mm dia CP Pillar cock |
| 112 | 25mm dia brass full way valve (Shakti make) |
| 113 | 32mm dia brass full way valve (Shakti make) |
| 114 | 15mm dia CP Health Faucet |
| 115 | 15mm CP Extension piece |
| 116 | 125mm CP grating |
| 117 | 15mm size C.P. flange |
| 118 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge |
| 119 | 2000 liters capacity PVC water storage tank in 1st floor |
| 120 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 121 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 122 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer\"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. (Ori Plast/Finolex/Supreme/Ashirvad Make) |
| 123 | 110mm U-PVC SWR Pipe Type-B |
| 124 | 75 mm U-PVC SWR Pipe Type-B |
| 125 | 110mm U-PVC P Trap |
| 126 | 110mm U-PVC door bend |
| 127 | 110mm U-PVC offset without ear |
| 128 | 110mm U-PVC Plain bend |
| 129 | 110mm U-PVC Cowl |
| 130 | 110mm U-PVC S/Jn door |
| 131 | 110mm U-PVC Plain tee |
| 132 | 110mm U-PVC Door tee |
| 133 | 110mm U-PVC Socket |
| 134 | 75mm U-PVC plain bend |
| 135 | 75mm U-PVC door bend |
| 136 | 75x75x75mm U-PVC double equal door Tee |
| 137 | 75mm U-PVC vent cowl |
| 138 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI \"p\" or \"s\" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 139 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 140 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral \"p\" or \"s\" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 141 | European water closet with \"S\" trap plain(Hindware/Parryware/Neycer make) |
| 142 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 143 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 144 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered \"Hot\" and \"Cold\" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
| 145 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with 22 Inch x 16 Inch pedestal |
| 146 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 147 | 25mm x 600mm long CP towel rail |
| 148 | CP towel Ring |
| 149 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. |
| 150 | 600mmx125mm plate glass shelf with CP/NP guard rails. |
| 151 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. |
| 152 | 600mmx450mm size Frammed mirror |
| 153 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 154 | CP soap holder |
| 155 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24 Inch x 18 Inch x 10 Inch sink |
| 156 | 600mmx450mmx250mm size porcelain Sink (Cera / Nyser/ Hindware) |
| 157 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 158 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 159 | Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) |
| 160 | Kajaria/Somany/Johnson tile 30cmx30cm |
| 161 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 162 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) |
| 163 | Kajaria/Somany/Johnson tile 45cmx30cm |
| 164 | Providing fitting, fixing of Aluminium door with anodized AL. door section of 9202 as vertical member,9201 as top and 9200 as middle bottom member with frame section No. 9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1855 Including all Cost of Labour. T&P hire charges of drilling machine. labour charges etc. complete. Ref : OBI10 |
| 165 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture\"s specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge |
| 166 | 100mm dia P.V.C. pipe |
| 167 | 160mm dia P.V.C. pipe |
| 168 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge |
| 169 | Inside size 76cmx76cmx46cm with 18 Inch dia RCC MH cover |
| 170 | Supplying all materials labour T&P and constructing 1.20m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 171 | 1 nos 20 Users septic tank (Size-2.30m X 1.20m X 2.10m) |
| 172 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 173 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 174 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 175 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete |
| 176 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 177 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 178 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 179 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 180 | RCC floor, roof slab chhaja up to 4.430 m height |
| 181 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with 23cm x11cm x 8cm size Fly Ash bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:6 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 182 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 183 | Supplying all materials,labour,T&P and providing 16mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 184 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 185 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 186 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories |
| 187 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 188 | Drilling of 200mm dia bore |
| 189 | 00 mtr to 30mtr |
| 190 | 31 mtr to 45mtr |
| 191 | Drilling of 150mm dia bore |
| 192 | 46 mtr to above |
| 193 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 194 | Lowering of 200mm dia P.V.C casing pipes |
| 195 | 00 mtr to 45 mtrs |
| 196 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber \"O\" ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 197 | 200mm dia PVC (sch-80) pipe |
| 198 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 199 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 200 | By DTH Rig |
| 201 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 202 | Rocky terrain with boulder formation for 300m depth |
| 203 | Supplying all materials, labour, T&P and providing fittings and fixing submersible pump with squarrel cage induction type submersible electric motor to run on 3 phase / single phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specification with suitable control panel, jointing with GI / PVC / HDPE pipes, electrification, testing commissioning, trial running, conveyance of all materials to worksite, payment to taxes etc all complete as per the specification and direction of the Engineer in charge. (Texmo / Crompton Greaves / Kirloskar make) |
| 204 | 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 205 | DOL Control panel |
| 206 | 40mm dia steel short piece |
| 207 | Well cap |
| 208 | 50mm size CI bracket |
| 209 | 2.50sqmm flat cable |
| 210 | 20mm dia rigid UPVC pipes |
| 211 | Steel rope with cover |
| 212 | Labour charges for lowering including transportation |
| 213 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge |
| 214 | 32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy