Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-02-2026 |
| 2 | 06-02-2026 | BOQ revised | BOQ | 17-02-2026 |
| Sl. No. | Item Description |
| 1 | M&L fornon-skid ceremic colouredtiles7 to 8 mm thick(Square/rectangular) areaof each tile exceeding0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match of tiles including dismantling of tiles and screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 2 | All as per serial item No 2 as above but as in vertical surfaces of tiles and rendering 10 mm thick in cement mortar 1:4, as in backing layer complete all as specified and directed. |
| 3 | M&L for non- skid ceremic colouredtiles7 to 8 mm thick(Square / rectangular) areaof each tile exceeding0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match incl dismantling of tilesand screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 4 | M&L for Glazed (plain /coloured) ceramic tiles wall 600x450x7mm thick on vertical faces of walls including 10mm thick rendeingin CM 1:4 set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting complete all as specified and directed. |
| 5 | M&L for20mm thick Granite (Z- black colour only) machine cut and machine, polished,and moulding,door cills, window cills, riser of steps and urinal partition wash basin platforms, cooking platfoams and flooring, skirting/ dados like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of marble laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing ding and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screed and dismantling of wall tile including cement mortar bedding complete all as specified and directed. |
| 6 | Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all as specified and directed. |
| 7 | Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all as specified and directed. |
| 8 | S&F Solid Prelam PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 9 | S&F 30 mm thick factory made one side Prelam PVC sheet other side decorative (door shutter) used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving aPanelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 10 | S&F 125x60mmx2mm thick pressed steel, frames for door with one or more rebates including filingand inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface complete all as specified and directed. |
| 11 | S&F 105x60mmx2mm thick pressed steel, frames for door with one or more rebates including filing andinner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS flat at bottom of the frameetc, including wooden texture finished paint on the frame surface complete all as specified and directed. |
| 12 | S&F 35 mm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side complete all as specified and directed. |
| 13 | M&L for 35mm thick plain framed glazed and skeleton shutter open rebated& prepared to receive glass, gauge etc, with sash bar edges of framingplain chamfered or rounded fitted with cut and mitered beads for securing glass including campsule mesh tightly fixed with the glazed and skelton door shutter etc, of 2nd class hard wood, members of shutters as specified in SSR Part - ISection 8 clause 8.24 (a) fitted to chowkats complete all as specified and directed. Note:- Campsule Mess will be measured and paid separately. |
| 14 | S&F in repairs Second class hardwood in scantlings as in cupboard frames complete all as specified and directed. |
| 15 | M&L in fixed in repairs 18/19mm thick Prelaminated ply board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 16 | S&F 100mm long stainless steel butt hinges complete all as specified and directed. |
| 17 | S&F 150mm long aluminum anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 18 | S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 19 | S&F 200 mm long aluminum anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 20 | S&F 200 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 21 | S&F 300mm long mild steel sliding door bolts plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. |
| 22 | S&F galvanised Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. |
| 23 | M&L for preparation of oldwooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 24 | M&L for painting to wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface complete all as specified and directed. |
| 25 | M&L for preparation of old steel surfaces of any description over 10 cm inwidth or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 26 | M&L forpainting to steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface complete all as specified and directed. |
| 27 | M&L for plain cement concrete 1:3:6type C-1(using 20 mm graded aggregate) as in bed blocks for hold fast/concrete filling in chowkhats and similar work etc complete all as specified and directed. |
| 28 | M&L for 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC@ 3% per 50 kg of cement including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed.Note :- WPC shall not be paid separately for this item. |
| 29 | M&L for 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4)using WPC@ 3% per 50 kg of cement newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed.Note :- WPC shall not be paid separately for this item. |
| 30 | M&L for 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. |
| 31 | M&L for 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6)newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. |
| 32 | M&L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished including taking down plaster the surface even and smooth withoutusing extra cement and necessary scaffolding complete all as specified and directed. |
| 33 | M&L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. |
| 34 | M&L for white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding complete all as specified and directed. |
| 35 | M&L for preparation of old decorated surfaces and applying three coat of white wash on ceilings surfaces and rubbing down with sand paper to have even and smooth surfaces complete all as specified and directed. |
| 36 | M&L for applying two coat of distemper oil emulsion white or tinted on old decorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed. |
| 37 | M&L for applying two coat of distemper oil emulsion white or tinted on newly decorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed. |
| 38 | M&L for applying one coat of cement based paint on old decorated or undecorated wall, roof surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed. |
| 39 | M&L for two coats of cement base paint on new plastered wall surfaces over a coat of primer of any description including preparation of surfaces complete all as specified and directed. |
| 40 | M&L for brick work with fly ash old size bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) and demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 41 | M&L brick work with fly ash old size bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) and demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 42 | M&L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofsunshades, shelves, lintels, Chajja ( up to IIrd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and directed. |
| 43 | Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and stair case similar work carefully and matching to adjoining disturbed complete all as specified and directed. |
| 44 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 45 | M&L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed. |
| 46 | M&L for rorm work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. |
| 47 | M&L for formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified and directed. |
| 48 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified and directed. |
| 49 | M&L for formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed. |
| 50 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 51 | S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 52 | M&L for RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves and stair case etc complete all as specified and directed. |
| 53 | M&L for RCC type B 1, 1:2:4 (20mm graded agg) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed. |
| 54 | M&L for RCC type B 1, 1:2:4 (20mm graded agg) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 55 | M&L for RCC 1:2:4 type B1 using 20 mm graded aggregate as in chajjas and like complete all as specified and directed. |
| 56 | Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and applying two coat of ezee at interval of 8 hours cure for thesurfaces complete all as specified and directed. |
| 57 | Demolition of cement concrete(un-reinforced), in any position and paving n.exc. 15 cm thickness (below or above ground level) including tile/ terrazzo floor complete all as specified and directed. |
| 58 | M&L for plain cement concrete 1:3:6typeC-1(using 20mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thickness and shall be filled with bitumen mastic i.e. bitumen and sand in proportion 1:2 complete all as specified and directed. |
| 59 | M&L 75 mm thick cement concrete type C1, 1:3:6 using 20mm graded stone aggregate in floor finishes / sub bases pavingetc finished even and rough to receive floor tiles complete all as specified and directed |
| 60 | Dismantling of roof terracing cement / brickconcrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified and directed. |
| 61 | M&L 40 mm thick cement concrete type B1 1:2:4 using 20mm graded stone aggregate in floor finishes even and fair to receive floor tiles / as in levelling course over roof complete all as specified and directed |
| 62 | M&L for 15 mm thick rendering on fair faces of concrete surfaces in CM 1:4 with water proofing compound concrete surface complete all as specified and directed.(NOTE:- WPC shall be measured and paid separatly) |
| 63 | Supply only liquid waterproofing compound complete all as specified and directed. |
| 64 | Supply and providing water proofing treatment with polyster based water waterproofing membrane standard water proofing membrane 3 mm thick, wt not less than 3.5 kg/ sqm having 10 years guarantee for water tightness all as specified and directed and described as under : (a) Prepartionof RCCroof surface and applying one coat of polymer modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymer primer @ 0.30 Kg/Sqm including cleaningsurface, all as per manufacture\"s specification complete all as specifiedand directed.(b) Supply & Providing APP based polyster based water waterproofing membraneminimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced/ torch application of membrane with 10 cm overlaps as required thereof, complete all as specifiedor as directed. |
| 65 | M&L for applying one coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified and directed. |
| 66 | Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed |
| 67 | S&F in repair vitreous china squatting pan of orrissa pattern long pan size580 x 440 mm white with \"P\"or \"S\" trap size100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of lime concrete bedding (1:2:5), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed. |
| 68 | S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed. |
| 69 | S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed. |
| 70 | S&F in repair 15 mm dia bib tap fancy type chromium plated with flange quarter turn incl all necessary fittings complete all as specified and directed. |
| 71 | S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts. complete all as specified and directed. |
| 72 | S&F 20 mm bore CPVC water tubingpipes, SDR 11 & Plain CPVC SDR 11 fittings and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any description and cutting chases for concealed water tubing and making good, cutting exceeding 20 cm girthwhere requiired completecomplete complete all as specified and directed. |
| 73 | S&F25 mm bore CPVC water tubing, SDR 11 & Plain CPVC SDR 11 fittings and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any description and cutting chases for concealed water tubing and making good, cutting exceeding 30 cm girthwhere requiired completecomplete complete all as specified and directed. |
| 74 | S&F in repairs 100mmx100mm stainless steel grating fixed complete all as specified and directed. |
| 75 | S&F in repair fancy type stainless steel towel rack size 600mm long including a pair of brass bracket complete all as specified and directed. |
| 76 | S&F in repairs vitreous chinaware coloured wash hand basinof size 55X40X82cm complete including CP Waste coupling ,waste pipe ,complete fixing arrangementand cutting for and pinning in walls & making good complete all as specifed and directed. |
| 77 | S&F in repair fancy type 150mm size square brass CP shower rose with or without swivel joints complete all as specified and directed. |
| 78 | S&F in repairs 75 mm x 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of approvedquality complete all as specified and directed. |
| 79 | S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed. |
| 80 | S&F designed looking mirror of size 0.75m x 1.20 m of selected quality 6 mm thick glass, mounted on fixed to wall with CPplugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 81 | S&F in repair fancy type 15 mm bore brass chromium plated pillar tap screwed down for iron pipe and fixed to WHB including taking out existing mixer from old WHB complete all as specified and directed. |
| 82 | S/F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls complete all as specified and directed. |
| 83 | S&F in repairs stainles steel Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod complete all as specified and directed. |
| 84 | S&F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position and dismantling of existing waater storage tank of any capacity complete all as specified in SSR Part I complete all as specified and directed. |
| 85 | S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all as specified and directed. |
| 86 | S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 87 | S&F Mild steel OHT cage, bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-290 Gde - E-165 complete all as specified and directed. |
| 88 | Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. all as specified or as directed. |
| 89 | S&F PVC (SWR) 110 mm diasoil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall complete all as specified and directed. |
| 90 | S&FPVC (SWR) 110 mmbore bends complete all as specified and directed. |
| 91 | S&F in repairPVC (SWR) multi floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain including jointing to waste pipe fixed in cement concrete (1:2:4), type B-1 complete all as specified and directed. |
| 92 | S&FPVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting complete all as specified and directed. |
| 93 | S&F PVC 100mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed. |
| 94 | S&F PVC 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed. |
| 95 | S&F 100mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed. |
| 96 | S&F 80mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed. |
| 97 | S&F in repairs 80 mm bore PVC cowl complete all as specified and directed. |
| 98 | S&F powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality) for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and including 5.50 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below-(i) Window frame of minimum size : 92 x38 mm X 1.15 mm thick for three tracks.63 x38 mm X 1.15 mm thick for two tracks. Note :- Rate for glass & wiremesh shall not be paid separately for this item. |
| 99 | S&Fforstainlesssteel glossy finish hat peg set of five tier with necessary fitting complete all as specified and directed. |
| 100 | S&F in repairPVC (SWR) floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed. |
| 101 | S&F mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed. |
| 102 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 103 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 100mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 104 | S&F computerised reflective letter / bldg number on ACP sheet (size 45 cm x 45 cm) and fixing with 04 nos of screw, rawal plug etc on wall in front of building complete all as specified and directed. |
| 105 | Dismantling of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. |
| 106 | M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone agg in sub base flooring complete all as specified and directed. |
| 107 | M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and no pigment, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed. |
| 108 | M&L for Machine pressed precast conctete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Gradeover 25mm thick sand cushioning including watering and consolidation complete all as specified and directed. |
| 109 | M&Lfor PCC kerb stone outer coloured surface machine pressed factory made of size 300 mm long , 300mm wide, 150mm thick and 350 mm in deepusing as in pcc (1:2:4) type B1 (using 20 mm graded stone agg) incl form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 110 | M&L providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in benching, coping,bed blocks including necessary form work, weatheringslightly rounded or chamfered angles andthroating complete all as specified and directed. |
| 111 | Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in sof/loose soilcomplete all as specified and directed. |
| 112 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 113 | Removing excavated Soil material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed. |
| 114 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in bed of drain pipe 150 mm bore including packing under and completely surrounding the pipes after they are laid and tested complete all as specified and directed. |
| 115 | M&L for 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laidin trenches and jointsincl dismantling of existing sewage pipe complete all as specified and directed. |
| 116 | M&L for cement concrete type D2 (1:4:8) (using 40 mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and directed. |
| 117 | M&L for brick work in burnt brick with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) and demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 118 | Providing and fixing SFRC (Steel Fibre Reinforced Concrete) cover and frame(heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS-12592, total weight of cover and frame to each be not less than 182 Kg, fixed in cement concrete 1: 2:4 complete all as specified and directed. |
| 119 | M&L for 15mm thick cement plaster mortar in cement and sand mortar (1:4) on faces of brick work or concrete surface mixed with water proofing compound as per manufacturer\"s instructions, surface finished even and smooth without using extra cement (WPC shalll be measured and paid for separately) complete all as specified and directed. |
| 120 | 15mm thick cement plaster mortar in cement and sand mortar (1:3) on faces of brick work or concrete surface mixed with water proofing compound as per manufacturer\"s instructions, surface finished even and smooth without using extra cement (WPC shalll be measured and paid for separately) complete all as specified. |
| 121 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 122 | Cutting into existing manholes for connecting new drains internal dai of 150 mm bore NP-2 pipes, making good to pipe and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished complete all as specified and directed. |
| 123 | M&L for Reinfoced Cement Concrete in nominal mixType B0 1:2:4 (12.5mm graded aggregate) as in cover slabs supported to wallsfor Manhole to fixing of SFRC cover Haevy duty HD-20 grade designation) etc complete all as specified and directed. |
| 124 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 125 | Add or deduct for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete complete all as specified and directed. |
| 126 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 127 | M&L for brick work in burnt brick with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius in half brick thick walls built in, built in CM (1:4) complete all as specified and directed. |
| 128 | M&L for brick work in burnt brick with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 129 | M&L for 15mm thick cement plaster on brick surfaces or concrete surfaces in cm (1:4) including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. |
| 130 | Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 131 | Taking down carefully unserviceable main switch DBs of any description of an size in any position complete all as specified and directed. |
| 132 | Material and labour for point wiring with single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered withmodular plateand cover of suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:-(a) One light / fan/ exhaust fan point controlled by one switch. |
| 133 | (b) One 5 pin 5 Amp switch socket out let point on an independent board. |
| 134 | (c) One 5 pin 5 Amp socket out let point controlled by one switch on same board. |
| 135 | All as per item 132 here in before but for one 15 Amp 6 Pin switch socket out let independent with2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistrandedincl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified. |
| 136 | S&F modular switch one way 6 A, 1 Module complete all as specified and directed. |
| 137 | S&F modular switch one way 16 A, 1 Module complete all as specified and directed. |
| 138 | S&F modular Socket 6 Amp, 2/3 Pin combined 2 Module complete all as specified and directed. |
| 139 | S&F modular Socket 6/16 Amp, 2/3 Pin combined 2 Module complete all as specified and directed. |
| 140 | S&F modular fan regulator Step up type, 120 Watt, 2 Module complete all as specified and directed. |
| 141 | S&F ceiling rose PVC/ Poly carbonate,Isolated body, threeterminal AC 230 volts complete all as specified and directed. |
| 142 | M&L for replacement oflamp holder, PVC / Poly carbonate, insulated bodymodular type with back plate batten/angle type for batten fittings complete all as specified and directed. |
| 143 | S&F in replacement LED mirror light fitting of 1 x 10 wattLED batten with aluminium housing with all accessories prewired suitable for wall /surface mounting complete with connection complete all as specified and directed. |
| 144 | S&F in replacement LED mirror light fitting of 1 x 20 wattLED batten with aluminium housing with all accessories prewired suitable for wall /surface mounting complete with connection complete all as specified and directed. |
| 145 | S&F LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed. |
| 146 | S&F security light fitting, LED type, 25 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source withintegrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with andincluding nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. |
| 147 | Taking down carefully ceiling fan from existing site and deposit in MES Yard complete all as specified and directed. |
| 148 | S&F ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 149 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed. |
| 150 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 151 | S&F MCB SPN 40 Amp 240 volt complete all as specified and directed. |
| 152 | S&F MCB single pole 6 to 32 Amp 240 Volt \"B\" curve 10 KA complete all as specified and directed. |
| 153 | S&F flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral linkscomplete including taking down old unserviceable complete all as specified and directed. |
| 154 | M&L for earthing complete including taking out old unsv and replacewith galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased inand including 15 mm dia GI \"light grade\" pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe \"light grade\" as water pipe from earth chamber andincluding excavation and earth work, PCC 1:3:6 typeC1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced complete all as specified and directed. |
| 155 | Taking down carefully serviceconnections of any description from pole, wallor service brackets etc including making good disturbed surface to match with the existing surface complete all as specified. |
| 156 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 2 core complete all as specified and directed. |
| 157 | M&L for sand cushioning laid in trenches for laying of LT UG cables complete all as specified and directed. |
| 158 | M&L for modular bricks common burnt clay building bricks, sub-class ‘B’ old size brick designation-75 for LT UG cable protection complete all as specified and directed. |
| 159 | S&F GI tubes light grade of dia 80 mm with all fitting and fixed complete for protection of LT UG Cables laidto walls or in floors or along with poles etc complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail