| Sl. No. | Item Description |
| 1 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed. |
| 4 | Demolition of brick workbuilt in cement mortor including all quoins,arches,pillars etccomplete all as specified and directed. |
| 5 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 6 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 7 | Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed. |
| 8 | Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed |
| 9 | Removing mortar from bricks and cleaning bricks including stacking for measurement and removing rubbish from site complete all as specified and directed.(Note:- Only serviceable old size bricks to be reused in the work shall be accounted for.) |
| 10 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed. |
| 11 | Taking down cement plaster of any descriptionon brick walls or concrete or stone and ceilingsincludingracking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 12 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 13 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqmeach including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 14 | M&L forLean Cement Concrete (1:5:10) type E-2 using 40mm gradedcrushed stone aggregate as in foundations, filling andmass concrete and filling in Sunken portioncomplete all as specified and directed. |
| 15 | M&L forLean Cement Concrete (1:3:6) type C-0 using 10mm gradedcrushed stone aggregate as infilling back sides of pressed steel framescomplete all as specified and directed. |
| 16 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) kitchen platform complete all as specified and as directed. |
| 17 | Formwork to rough finished surfaces of edges of concrete floor and roofs and similar work exceeding 5cm but not exceeding 10cm wide complete all as specified and directed. |
| 18 | M&L for brick work built in cement mortar (1:6) with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 19 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work. |
| 20 | M&L for Reinforced Cement Concrete Nominal Mix M-20 Grade using of 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors , roofs, landings, balconies, canopies, deck slabs and in shelvesand the like complete all as specified and directed. |
| 21 | M&L for Cast-in-SituPlain Cement Concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate in Cover fillet minimum radius of 75mm as in roof and parapet wall junction,roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, slopingon roofincluding form work complete all as specified and directed. |
| 22 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified and directed. |
| 23 | S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etcincluding making good jambs portion by providing plaster in CM 1:4 and finishes as per existingcomplete all as specified. |
| 24 | S&F 35mm thickfactory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etcfor doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed. |
| 25 | S&F factory made35mm thick Plain framed, panelled wooden shutter (any number of panels) of second class hard wood (except Mango)with lock rail and panel 12mm exterior grade wood veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 26 | S&F in replacement Factory Made Box Type Steel Windows with glazing bars made of ERW tube hollow \"P\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung skelton & glazed shutters, frame of ERW tube \"P\" section size50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gaugeto frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No.1/3 to 3/3 including taking down of old existing window complete all as specified and directed :-(i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window(ii)Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii)MS Tower bolt 150mm long-02 Nos per leaf(iv)Z section 20mmX25mm,100mm long stopper -01 Nos per leaf(v)Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi)MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window).(viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Glass panes and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 27 | S&F in replacement Factory Made Box Type Steel Windows without glazing bars made of ERW tube hollow \"P\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung i.e. guagedshutters, frame of ERW tube \"P\" section size50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gaugeto frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No.1/3 to 3/3 including taking down of old existing window complete all as specified and directed :-(i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window(ii)Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii)MS Tower bolt 150mm long-02 Nos per leaf(iv)Z section 20mmX25mm,100mm long stopper -01 Nos per leaf(v)Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi)MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window).(viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Wire cloth and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 28 | S&F in replacement Factory Made Box Type Steel Ventilators side /top hung with glazing bars or dovetailed or welded made of ERW tube \"P\"-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No.1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site.4. Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 29 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 30 | S&F 50mmx47mm size solid PVC door framemade out of 5mm plain colour PVC sheetreinforced with MS square tube, complete all as specified shown on drawing and specified and directed. |
| 31 | S&Ffactory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed. |
| 32 | S&F 100mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed. |
| 33 | S&F 200mm long aluminium anodised barreltower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 34 | S&F 150mm size aluminium door handle, cast type, anodised complete all as specified and directed. |
| 35 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 36 | S&FFloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover platefixed in floor complete all as specified and directed, |
| 37 | S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed, |
| 38 | S&F in repairs 25mm dia mild steel curtain draperyrods, fancy type, epoxy powder coatedwith and including finials, bubs and brackets, stops and rollers etc. complete all as specified and directed |
| 39 | S&F Stainless Steel WireCloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 40 | S&F 4.0mm thick, plainsheet glass, ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 41 | S&F 4.0mm thick, frosted glass, ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 42 | S&F Structural SteelFe-290 Gde E-165 Rolled sections framed work as in doors or gates or cooler stands of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing completeand similar workcomplete all as specified and directed. |
| 43 | S&F 10mm dia and over mild steel TMT bars , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diacomplete all as specified and as directed. |
| 44 | M&L for 50mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 45 | M&L forPlain Cement Concrete (1:2:4) type B-1 using 20mm gradedcrushed stone aggregate as in roof padding surfaces finished even and fair complete all as specified and directed. |
| 46 | M&L for25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm gradedcrushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 47 | M&Lfor 18 to 20mm thick Granite Salb (table rubbed and mirror polished) as in steps ,jambs,pillars,cooking platform and like includingpointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade other than white and blacktypes over a15mm thickcement screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 48 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in floors including rubbing and polishing complete over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 49 | M&L for Machine cut kota stone slab 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in vertical surfaces such as skirtings, dados, risers and steps etcincluding rubbing and polishing complete over and including 10mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 50 | M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finishcomplete. complete all as specified and directed. |
| 51 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality,Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 52 | M&L for 7mm thick(Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm)Glazed Ceramic Coloured Tiles,in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etcset and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 53 | M&L for 12mm thick rendering cement plaster in cement mortar (1:6) on other than fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 54 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) onany facesof brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 55 | M&L for 10mm thick rendering cement plaster in cement mortar (1:3) in screed bed or bedding layer for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer\"s instructionsfinished even and fairwithout using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 56 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer or cement plater to the sunken portion, mixed with water proofing complound as per manufacturer\"s instructions finished even and fairwithout using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 57 | M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 58 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 59 | M&L for applying evenly a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion complete all as specified and directed. |
| 60 | M&L for applying evenly a bitumen tack coat of industrial bitumen 85/25 @ 1.2 kgs/Sqm incl cleaning surfaces complete all as specified and directed. |
| 61 | M&L forOne layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise ofpolymeric membranes respectively and sealed all overlaps and joints as manufacturer\"s instructions. |
| 62 | M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cementcomplete all as specified and directed. |
| 63 | M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cementcomplete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace. |
| 64 | M&L forpreparing new plastered surfaces of walls anddistempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 03mm thick plaster of paris wall care putty to prepare surface even and smooth complete all as directed. |
| 65 | M&L for complete removal of existing treatmenton walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed. |
| 66 | M&L for complete removal of existing treatmenton walls and distempering with two coats of distemper oil emulsion white or tinted over 3mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 67 | M&L forpreparing new plastered surfaces of walls andapplying three coats of lime white wash complete all as specified and directed. |
| 68 | M&L forpreparing new plastered surfaces of ceiling andapplying three coats of lime white wash complete all as specified and directed. |
| 69 | M&L forpreparing old surfacesdecorated plastered or unplasteredsurfaces ofwalls and applying one coat of lime white wash complete all as specified and directed. |
| 70 | M&L forpreparing old plastered surfaces of ceiling andapplying one coat of lime white wash complete all as specified and directed. |
| 71 | M&L for preparation of new wood or wood basedsurfaces of any description, not otherwise described,over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primercomplete all as specified and directed. |
| 72 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed. |
| 73 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floorscompleteall as specified and directed. Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 74 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 75 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 76 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 77 | S&F 75mm dia PVC (SWR) bends any radiuscomplete all as specified and directed. |
| 78 | S&F 110mm dia PVC (SWR) bends any radiuscomplete all as specified and directed. |
| 79 | S&F 75mm dia PVC (SWR) vent cowlcomplete all as specified and directed. |
| 80 | S&F 110mm dia PVC (SWR) vent cowlcomplete all as specified and directed. |
| 81 | S&F 110mm dia PVC (SWR) \"P\" traps for Water Closetscomplete all as specified and directed. |
| 82 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 83 | S&F 3-layer PP-R Polypropylene random copolymer concealed pipes size 63 mm SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings, floors, roads and laid in trenches etc including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing with all fittings complete all as specified and directed. |
| 84 | S&F 3-layer PP-R Polypropylene random copolymer concealed pipes size 32mm SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings, floors, roads and laid in trenches etc including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing with all fittings complete all as specified and directed. |
| 85 | S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections as Hot water pipe duly insulated with 50mm thick rock wool/mineral wool all around pipe, chicken meshand 25 SWG aluminium cladding andfixed complete to walls and celling or laid in floor, laid in trenches as required complete all as specified and directed. |
| 86 | S&F 25mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connectionsfixed complete to walls and celling or laid in floor, complete all as specified and directed. |
| 87 | S&F 15mm bore Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2with all fittings and connections laid in trenches complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 88 | S&F 20mm bore Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 with all fittings and connections laid in trenches complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 89 | Fixing only old retrieved serviceable 15mm bore Galvanised Medium Grade Steel Water Tubingand fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed. |
| 90 | Fixing only old retrieved serviceable 20mm bore Galvanised Medium Grade Steel Water Tubingand fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed. |
| 91 | S&F 15mm bore Bib Taps,fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 92 | S&F in repairs 15mm bore Bib Taps,fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 93 | S&F in repairs 15mm borefancy type, chromium plated, Angle Valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionscomplete all as specified and directed. |
| 94 | S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy,with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipecomplete all as specified and directed. |
| 95 | S&F 15mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipescomplete all as specified and directed. |
| 96 | S&F 20mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipescomplete all as specified and directed. |
| 97 | S&F 25mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipescomplete all as specified and directed. |
| 98 | S&F in replacement PP-R Gate valves (brass insert)50mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified and directed. |
| 99 | S&Fin replacement PP-R Gate valves (brass insert)20mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified and directed. |
| 100 | M&L for Making connection of PP-R distribution branch with PP-R main of sizes 20 to 50mm outer dia of pipes by providing and fixing tee including cutting and making fusion joint etc with all fittings complete all as specified and directed. |
| 101 | S&F in repair pressure Jet spray of chromium plated steel for EWC seats with and includingincluding PVC connection and CP fittings complete all as specified and directed. |
| 102 | S&F 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered \"HOT\" or \"COLD\" with long screwed shanks and fly nuts, screwed foriron pipe complete all as specified and directed. |
| 103 | S&F 15mmPVC connections 450mm long heavy duty with brass nuts adaptors andwashers and rubber gaskets at both ends complete all as specified and directed. |
| 104 | S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc.screwed for iron pipe or brass ferrule hoisted and fixed including dismentling andtaking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 105 | S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc., screwed for iron pipe or brass ferrule hoisted and fixed including dismentling andtaking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 106 | S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipecomplete all as specified and directed. |
| 107 | S&F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipecomplete all as specified and directed. |
| 108 | S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting standincluding waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed. |
| 109 | S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed. |
| 110 | S&F in repairs Vitreous China urinals, flat back complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed. |
| 111 | S&F Vitreous China Urinal Partition white of size 310 x 700 complete all as specified and directed. |
| 112 | S&F in repairs 10 litres capacity low level PVC valveless syphonic action typeflushing cistern with inlet ball valve, float and handle including brackets complete all as specified and directed. |
| 113 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed. |
| 114 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)complete all as specified and directed. |
| 115 | S&F in repairs 100 mm dia Chromium plated shower rosewith 125mm long CP arms, with or without swivel joints, including fixing complete to steel pipe or union complete all as specified and directed. |
| 116 | S&F in repairs tubular Towel Rail 20mm dia brass chromium plated 600mm long between flangestype \"D\",with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 117 | S&F in repairs Soap dish of chromium plated steel fixed to wall with chromium plated steel screws and PVC gutties complete all as specified and directed. |
| 118 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out completeall as specified and as direcetd. |
| 119 | Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 120 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 121 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 122 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for One light/fan/Bell Pointcontrolled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 123 | ditto all as per item No 122 but for one socket outlet on the sameboard controlled by one single pole one way switch |
| 124 | ditto all as per item No 122 but for one 5 amps socket outlet independentcontrolled by one single pole 5 Amp switch. |
| 125 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed forone 3/5 pin 15 Amps switch socket out let on the independentboard controlled by one single pole one way switch.Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 126 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 4.0 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 4.0 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed forone 3/5 pin 15 Amps switch socket out let on the independentboard controlled by one single pole one way switch.Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 127 | S&F5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 128 | S&F15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 129 | S&F5/6 AmpSocket outlet 2 in1, 3 pin flush typeISI marked complete all as specified and directed. |
| 130 | S&F15/16 AmpSocket outlet 2 in 1, 3 pin flush typeISI marked complete all as specified and directed. |
| 131 | S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated bodyomplete all as specified and directed. |
| 132 | Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and directed. |
| 133 | S&F 350mm sweep Exhaust Fan, steel body AC single Phase. 230V,900 RPM with blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts (12mm dia and 15cm long) , fixing with nuts and washers, making connection wih copper onductor PVC flexible twin wire of size 23/0.0076and including citting holes and making good in cement mortar (1:4) and finshing surfcae to match with existing surfacescomplete all as specified and directed. |
| 134 | S&F 300mm sweep Exhaust Fan, sturdy Engineering plastic body with louvers AC single Phase. 230Vwith blades and frame and louvers with Copper windingcomplete all as specified and directed. |
| 135 | S&F Evaporative Air Cooler (Desert Cooler) of capacity 4000Cum/Hourdischarge in steel body made of 18 SWG galvanised steel sheet for main body and covers duly painted with two coats of hammer bone paint first quality over a coat of red oxide primer complete with inner and outer sides with front grill made out of steel ofheavy duty sheet, propeller cooler fan with aluminum blades 500mm sweep dia with induction motor, 220 Volts, AC single phase copper wound with tullu pump 1 HP water proof, filter media with PVC drain pipes and coonector, selector switch including cable with plug top etc complete all as specified and directed. |
| 136 | S&F Structural SteelFe-290 Gde E-165 Rolled sections framed work as in cooler stands, Solar Water Heater stand, Stagging and protection of PVC Water tank etc madeof angle, flat ironor other section welded joints, fixed on floor or in walls or moving on rollers, or stand , painted with two coats of syntehic enamel paint black colour over a coat of rex oxide zinc chrome primer complete and similar workcomplete all as specified and directed. |
| 137 | Supply, Install, Testing and Commissioning of ‘SOLAR WATER SYSTEM\" (Evacuated Tube Collector) based on direct transferring of heat of capacity 500 LPD including electriccal back up of 3.0KW complete all as specified and directed. |
| 138 | S&F 1x10WLED tube light fitting mirror type with high out put diffuser 2 feet, 10Watt,220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 139 | S&F 1x20WLED tube light fitting, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete all as specified and directed. |
| 140 | S&F in repairs 1X18 WLED tube light fitting with LED 18WSurface type down light withPDC aluminium housnig downlights corona series warm white color including taking down existing light fittings with sensor based on/off technologyetccomplete all as specified and directed. |
| 141 | S&F in repairs 1X18 WLED tube light fitting with LED 18WSenso downlightersurface type down light PDC aluminium housing downlights corona series warm white color including taking down existing light fittings with sensor based on/off technologyetccomplete all as specified and directed. |
| 142 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket made of 40mm dia GI light grade pipe 1.5m long bend to shape including fixing on pole with suitable size of flat iron clamps, nust, bolts & washers etc complete all as specified and directed. |
| 143 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs (Verticle type)fitted wit ABS frame, 240 Volts 200Amps rated bus bar,Neutral link,Earth bar andDin rail,2 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 144 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs (Verticle type)fitted wit ABS frame, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar andDin rail,4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 145 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar andDin rail,8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 146 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type\"B\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 147 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral(SPN) current carrying capacity 40 Amp, 240V, breaking capacity 10 KA, type\"C\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 148 | S&F Miniature Circuit Breaker (MCB) Tripple Pole and Neutral(TPN) current carrying capacity 63Amp, 240V, breaking capacity 10 KA, type\"C\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 149 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cablesingle core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 150 | S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cablesingle core for continuous earthing including taking down existing submain wiring and conduits etccomplete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 151 | Supply, lay, test, joint and commission LTXLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of sizecross sectional area 50Sqmm x 3 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, fixed on polecomplete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 152 | M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid. |
| 153 | Supply and lay cable protection cover withBricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed. |
| 154 | Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables. complete all as specified and directed. |
| 155 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm diagalvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light gradeconnected to main switch board or main control board and20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4)type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-Icomplete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wirefrom top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail