| Sl. No. | Item Description |
| 1 | Taking down cement plaster including racking out joints hacking for key and scrubbing down with water etc. complete all as specified and directed. |
| 2 | M&L for rendering 15mm thick in cement plaster 1:6 on surfaces other than fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and fair without using extra cement complete all as specified and directed. |
| 4 | M&L for rendering 10mm thick in cement plaster 1:4 on concrete surfaces of ceilling and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for two coats of external emulsion paintincl preparation of newsurface of wall complete all as specified and directed. |
| 6 | M&L for two coats of external emulsion paintincl preparation of old decorated surface of wall complete all as specified and directed. |
| 7 | M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 8 | M&L for preparation of old treated surface of wall and applying two coats of oil bound distemper complete all as specified and directed. |
| 9 | M&L for preparation of new plastered surface and applying three coats of white wash on ceilling complete all as specified and directed. |
| 10 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specfied and direcetd. |
| 11 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed. |
| 12 | S&F solid PVC door frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 13 | S&F factory made solid panel PVC door shutter 30 mm thick (Style) consisiting of frame made out of MS tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain coloured PVC \"C\" channel having a PVC sheet strip of 20 mm which stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rails & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 14 | S&F 200 mm long stainless steel grade 302 barrelbarrel tower bolts and fixed complete all as specified and directed. |
| 15 | S&F 75 mm long butt hinges, 2.00 mm thick (minimum) stainless steel grade 304 with SS hinge pinand fixed complete all as specified and directed. |
| 16 | S&F 150 mmstainless steel grade 302 handles 3.00 mm thick (minimum) complete all as specified and directed. |
| 17 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames)exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed. |
| 18 | S&F Mild steel work as in chowkats/frame of door or gates of angle or other section with gusset plate , rail braces etc complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and inclu either hooks and hinges or steel hanging door fittings ( exclusive of steel , sheetingor other covering , running rails and guisides ) and hanging also fastening and fixing complete all as specified Frade Fe 410 (Gde E-320) |
| 19 | S&F pressed steel frames 105X60 mm for doors with one or more rebates including necessary fixing lugs,hinges,lock strike plate,etc complete all as specified and directed. |
| 20 | S&F pressed steel frames 125X60 mm for doors with one or more rebates including necessary fixing lugs, hinges ,lock strike plate etc complete all as specified and directed. |
| 21 | M&L for providing cement concrete type C1, 1:3:6 (20 mm graded aggregate) as in chowkhats or frames complete all as specified and directed. |
| 22 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. |
| 23 | S&F 300mm long stainless steel grade 304 sliding door bolts, bolt or clip type,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 24 | M&L for 2nd class hard wood glazed and skeleton shutters 35mm thick open rebated and prepared to receive glass , gauze etc (without sash bars) , edges of framing plain , chamfered or rounded , fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) , supplied and fitted to chowkats complete all as specified and directed. |
| 25 | Dismantling boarding any size and description fixed in any position withnails complete all as specified and directed. |
| 26 | S&F 20mm thick PVC boarding with nails as in cub board shelves in any situation planed one side with butt joints complete all as specified and directed. |
| 27 | S&F for built in steel cup board with pressed steel frame of size 75 mm x 45 mm x 1.25mm thick with preseed steel shutter 1 mm thick Godreg pattern fixed to masonry wall by hold fast made out of 25x3 mm flat iron including ms hanging rod of 10 mm dia with bracket fixed on inner side of one leaf of shutter and on other leaf provision of ms peg set of 3 pegs including spray including locking arrangement painting with two coats of synthetic enamel paint over one coat of ref oxide primer with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame and shutter and making god disturbed portion in cm 1:3 or PCC 1:2:4 complete all as specified and directed. |
| 28 | S&F 100 mm long butt hinges, 2.00 mm thick (minimum) stainless steel grade 304 with SS hinge pinand fixedcomplete all as specified and directed. |
| 29 | S&F 150 mmstainless steel grade 302 handles 3.00 mm thick (minimum) complete all as specified and directed. |
| 30 | S&F of 200 mm long stainless steel grade 302 barrelbarrel tower bolts and fixed complete all as specified and directed. |
| 31 | M&L for preparation of wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coat of synthetic enamelpaint over a coat of pink primer complete all as specified and directed. |
| 32 | Taking down steel/wooden window/ventilator of any size and description complete all as specified and directed. |
| 33 | S&F steel window with pressed steel frame (size 95x45x1.25mm) side hung shutter including box type hinges with steel handle and steel peg stay complete with glazed openable shutter with glazing bar (open out side) and wire gauzed openable shutter without glazing bar (open inside), devetailed or welded complete all as specified and directed and as per Drg no TD/088 Dated 07 Jan 2002. (i) Two shutter i.e. wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit. (ii) rate for filling of PCC frame deemed to be included in quoted rate. (iii)MS grill,wire gauge and glassshall be measured and paid seperately. |
| 34 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.Note: S&F rates, include for anodised aluminium hard ware as indicated, pvc roller, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames. |
| 35 | S&F steel ventilators, bottom portion fixed type glazing and top portion with top hung wire gauze shutter dovetailed or welded complete all as specified and directed. |
| 36 | S&F framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. Railings, frame work of of water tanks and ssimilar work conforming to Fe410 complete all as specified and directed. |
| 37 | S&F 3 mm thick sheet glass, Ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 38 | S&F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm complete all as specified and directed. |
| 39 | M&L for applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation over 10 cm width and girth complete all as specified and directed. |
| 40 | Demolition of cement concrete (un reinforced) of any descriptionand in any position not other specifically provided for complete all as specified and directed. |
| 41 | M&L for cement concrete (1:5:10) type E-2 as in foundation filling and mass concrete complete all as specified and directed. |
| 42 | M&L for preparation of sunken floor and applying a coat of hot bituminous primer @ .30 kg/sqm and applying a coat of industrial bitumen 85/25 @ 1.20 kg/sqm over primer and laying modified polymeric water proofing membrane(weight not less than 3 kg/sqm 2 mm thick consisting 100 mmmicron HMHDE FILM ) and applying one coat of industrial btumen grade 85/25 @ 1.2 kg/sqm on top of membrane with 100 mm overlap at side end lap where requiredover 10 mm thick rendering in CM 1:4 includingintegral waterproofing compound 3% and taking down existing plasteringas per manufacturer instruction and complete all as specified and directed |
| 43 | Removing existing water proofing treatment and preparing surfaces to the entire satisfaction of Engineer-in-Charge / GE including taking down existing plaster, cleaning of all foreign material such as grass, roots, dust etc and roughening the concrete surfaces by wire brushing and washing down to remove dust etc. flushing at junction of parapets complete and removing the same to the places where directed by Engineer-in-Charge |
| 44 | M&L for rendering 15mm thick on roof surfaces in CM 1:4 complete all as specified and direcetd. |
| 45 | M&L for preparation of roof surfaces, applying a coat of primer@ 0.40Kgs/sqm applying a coat of bitumen grade 85/25 @1.2kg/sqmsupplying and laying water proofing treatment with using polymeric water proofing membrane (weight not less then 3kg/Sqm) consisting of 100 micron HMHDPE film centre core including applying a coat of bitumen 85/25 grade @ 1.2kg per sqm on top surface of membrane and torch application of membrane with 10cm overlap where required and finally finished with and including a coat of aluminium paint @0.20Ltr/Sqm as per manufacture instruction complete all as specified and directed. |
| 46 | Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 47 | M&L for Glazed ceramic coloured tilesin vertical surface 350 mm x 250 mm x 7mm/450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white cementor colour cement including 10 mm thick in CM 1:4 complete all as specified and directed. |
| 48 | M&L for providing non- skid glazed ceramic tiles coloured7-8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but n xc 0.11 sqm, in floor etc set and joited with neat cement slurry and pointed in coloured cement to matchcoloured tiles including 15 mm thick cement screed bed in CM 1:6 complete all as specified and directed. |
| 49 | M&L for vitrified light shade coloured ceramic tiles 10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 50 | M&L for Vitrified light shade coloured ceramic tiles 10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sqm in skirting/dado etcset and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 51 | S&Fin repair vitreous china squatting pan \"Orissa\" pattern size 580mmx440mm white with integral foot rests excluding flushing cictern and flush pipe complete all as specified and directed. |
| 52 | S&F in repair 10 ltrs capasityPVC valveless syphonic action typeflushing cistern low level white , with inlet ball valve, float and handle including bracket and flush pipe of polyethylene of low or high densityor PVC 32 mm dia for low level cistern complete all as specified and directed. |
| 53 | Taking down old 110/75mm borePVC(SWR) pipes in any position complete all as specified and directed. |
| 54 | S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement complete all as specified and directed. |
| 55 | S&F 75 mm bore PVC (SWR) pipes ofsingle socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 56 | S&F 75 mm bore PVC (SWR) pipes ofsingle socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 57 | S&F 75 mm bore. PVC (SWR) bends complete all as specified and directed. |
| 58 | S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door complete all as specified and directed. |
| 59 | S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 60 | S&F 110 mm PVC (SWR) bend any radius complete all as specified and directed. |
| 61 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 62 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. |
| 63 | Taking up or down existing GI Tubing 15 mm dia & connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 64 | Taking up or down existing GI Tubing 20 mm dia & connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 65 | S&F 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 66 | S&F reducing Tee/ Elbow/ Socket 20 x 16 mm dia with Female Brass Threaded Adaptor (FTA/FBTA) complete all as specified and directed. |
| 67 | S&F 20 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 68 | Refixing only GI tube 20mm dia medium grade will new fittings and fixed to wall, ceiling or laid in floor and ceilingand wall all as specified and dircted |
| 69 | S&F Shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and directed. |
| 70 | S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs , washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed. |
| 71 | M&L for 10mm dia and over mild steel TMT bars, cut to length , bent to shape required including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips , quality of steel conforming to demormed or twisted bars Fe-410-W (Gde E-250) complete all as specified and directed. |
| 72 | S&F in repair 15 mm bore dia of Bib taps cast copper alloychromium plated handle screw down ,screwed for iron pipe or or brass ferrule complete all as specified and directed. |
| 73 | S&F in repair 15 mm bore dia pipe angle cock cast copper alloy chromium plated handle screw down ,screwed both end for iron pipe or or brass ferrulecomplete all as specified and directed. |
| 74 | S&F in repair 15 mm bore dia of pipe stop cock (Concealed) cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed both end for iron pipe or or brass ferrule with long shank and cup complete all as specified and directed. |
| 75 | S&Fin repair swivel shower rose of brass Chromium plated for fixing with 15mm pipe fixed complete all as specified and directed. |
| 76 | Dismantling ofexisting water tanks capacityexc 500 ltr n exc 1000Ltsand removing to store complete all as specified and directed. |
| 77 | S&F rotational moulded polethylene water tank of 500 ltrs capacity triple layered (cylindrical vertical with closed top) hoistedand fixed in position all as pacific SSR Part- I complete all as specified and directed. |
| 78 | S&F 20 mm bore CPVC ball valve or gate valves, with CPVC/PTMT wheel head complete all as specified and directed. |
| 79 | S&F 20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe complete all as specified and directed. |
| 80 | S&F in repair vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe complete all as specified and directed. |
| 81 | S&F in repair 15mm bore pillar tap cast copper allloy with capstan headChromium plated scwed down with or without letter Hot or Cold with long shank and fly nuts scrwed for iron pipe and fixed complete all as specified and directed. |
| 82 | S&F in repair floor door stopper of aluminium alloy body and tongue , anodised with hard drawn steel spring fixed in floor , overall length of cover plate 150mm complete all as specified and directed. |
| 83 | Supply only 32mm dia wast fittings brass chromium plated for basin with long screwed shank and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 84 | S&F in repair PVC connection 15mm bore length not less than 300 mm long with both ends PTMT nuts complete all as specified and directed. |
| 85 | S&F in repair 300mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 86 | S&F in repair CP towel rail20mm dia, 600 mm long between flanges complete all as specified and directed. |
| 87 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil for roads to required slope gradient, camber etc complete all as specified and directed. |
| 88 | Removing excavated material exc.1.5KM n. exc. 5.0KM and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 89 | M&L for hardcore of broken stone or boulders of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watere and rammed to a true surface complete all as specified and directed. |
| 90 | M&L for sand filling under floors or in foundations including watering and consolidation of 75 mm thickness complete all as specified and directed. |
| 91 | M&L for 60mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment,any shape and size confirming to IS 15658-2006, M-35 Grade complete all as specified and directed. |
| 92 | Providing precast cement concrete 1:2:4 Type B 1 (using 20 mm graded stone aggregate) in windows or door cills, lintels, bressumers, steps, quoins blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates etc. (of any section indicated) with plain fair faces,including chamfers, weatherings, throating etc. and setting in cement mortar 1:6 complete all as specified and directed. |
| 93 | Demolition of stone slab and tiles of any description or thickness in floor, aprons etc. complete all as specified and directed. |
| 94 | M&L for machine cut mirror polish kota stone slab flooring20-25mm thich over 15mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigmen to match the shad of the slab including round nosing at corners rubbing and polishing complete all as specified and directed. |
| 95 | M&L for machine cut mirror polish kota stone slab 20-25mm thich in riser of step, skirting, dado and pillers over and including 15mm thick rendering in CM 1:4 including rubbing and polishing complete all as specified and directed. |
| 96 | M&L for granite (of any type) tiles 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing types over 20mm thick screed bed in CM 1:6 complete complete all as specified and directed. |
| 97 | M&L for 18-20 mm thick granite (of any type) tiles machine cut in skirting/ dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick rendering in CM 1:4 complete all as specified and directed. |
| 98 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 99 | M&L for RCC type B0 1:2:4(12.5 mm graded aggregate) in slabs supported on walls,beams and columns in floors,roofs,landings,balconies,canopies,deck slabs and in shelves complete all as specified and directed. |
| 100 | M&L for 10mm dia and over mild steel TMT bars, cut to length , bent to shape required including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips , quality of steel conforming to demormed or twisted bars Fe-410-W (Gde E-250) complete all as specified and directed. |
| 101 | Demolition of brick work in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 102 | S&F in repair stainless Steel plate rack of size 90x80x25cm made with 1.00 mm thick sheet including taking out existing wooden plat rack complete all as specified and directed. |
| 103 | M&L for brick work with sub class B old size bricks burnt straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 104 | Demolition of cement concrete (un reinforced) in ground floor for pavings n.exc 15cm thickness (below are above ground level) complete all as specified and directed. |
| 105 | M&L for 75 mm thick PCC 1:3:6 type C2 using( 40mm graded stone aggregate) as in plinth protection/foot path finishing cement concrete even and smooth with out using extra cement complete all as specified and directed. |
| 106 | S&F fancy type curtain rails 25mm dia harisson rails, mild steel, chormium plated with fixing bracket, stops,rollers etc for hangging curtain rod complete all as specified and directed. |
| 107 | S&F in repair 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer complete all as specified and directed. |
| 108 | Dismantling corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 109 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 110 | Taking down carefully of point wiring (light , fan, socket or power)complete (fittings such as switches, ceiling roses, pendants, regulator, sockets etc to be measured separately) removing from site of work and making good to the disturbed surfaces of walls/ floors etc complete all as specified and directed. |
| 111 | Taking down carefully old unserviceable fittings & Fixers of any type and any size complete all as specified and directed. |
| 112 | Taking down carefully old unserviceableby unscrewing from DB box, MCB SP/ SPN/ TPN of any size & any capacity complete all as specified and directed. |
| 113 | Taking down carefully old unserviceable sub main wiring of any size complete all as specified and directed. |
| 114 | M&L for concealed point wiring using approved colour coding as per IS ,with stranded copper conductor 1.5 sq mm(nominal area),single core,FRLSH,PVC insulated and unsheated cable 1100 volts grade,ISI 694, marked in and including heavy duty PVC concealed conduit medium grade ISI marked 20 mm dia with all fittings PVC junction boxes, etc. modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 2 to 18 modules with inner and outer modular cover plates, including FRLSH, rigid PVC insulated unsheated stranded copper conductor 1.5 sq mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified, for the following Note:(i)Cutting/chasing of wall etc. deemed to be included in quoted rate of this item.(ii) Modular GI metl flush/sunken box along with modular base/front cover plate are inclusive in the item rate quoted(iii)Only switches sockets and fan regulators shall be measured and paid separately(a).One light point controlled by one switch |
| 115 | (b).One fan point controlled by one switch |
| 116 | (c).One exhaust fan point controlled by one switch |
| 117 | (d).One 3-pin socket outlet 5 Amp on independent board. |
| 118 | (e).One 3 pin socket outlet 5 Amp on same board |
| 119 | (d).One light point controlled by two way switches |
| 120 | (f).One bell point controlled by one switch |
| 121 | All per Srl item No. 114 here-in-before, but with 2.5 Sqmm copper conductor cable complete all as specified for One 3 pin socket outlet 15 Amp on independent board. |
| 122 | M&L for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 6sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 6 sqmm as an earth continuity conductor complete all as specified and directed.Note : Two run of 6.00 sqmm copper cable, one run of 6.00 sqmm copper cable and one run of conduit shall be measured as one unit. |
| 123 | M&L for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified and directed.Note : Two run of 6.00 sqmm copper cable, one run of 6.00 sqmm copper cable and one run of conduit shall be measured as one unit. |
| 124 | S&F modular switchpolycarbonate SP one way 6 Amps complete all as specified and directed |
| 125 | S&F in replacement two way modular switch 6 amps, 230 volts complete all as specified and directed. |
| 126 | S&F modular switch polycarbonate SP one way 16 Amps complete all as specified and directed. |
| 127 | S&F modular bell push6 amp single pole one way complete all as specified and directed. |
| 128 | S&F modular socket out let 3 pin 6 amp multipurpose flash type complete all as specified and directed. |
| 129 | S&F modular socket out let 5 pin 6/16 Amp multipurpose, flush type 240 volt complete all as specified and directed. |
| 130 | S&F ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified and directed. |
| 131 | S&F bell ding dong type AC 230 volt single pole complete all as specified and directed. |
| 132 | S&F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and directed. |
| 133 | S&F LED bulb 9 watt rechargable include connection complete all as specified and directed. |
| 134 | M&L for replacement of Step regulator electronic modular fan socket type regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed. |
| 135 | Taking down Exhaust fan of any size and deposited to E/M storeyard for refixing complete all as specified and directed. |
| 136 | M&L exhaust of cupper binding with capacitor complete all as specified and directed. |
| 137 | Taking down fan of any size, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed. |
| 138 | S&F 1200mm Glaze BLDC ceiling fan (white) complete with remote control and electronic type regulator and accessories 230 V,1200 mm sweep. 5 star rated complete all as specified and directed. |
| 139 | S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. |
| 140 | S&F 240V, 10 KA \"B\" curve miniaturecircuit breaker (MCB) of single poles and currentcarryingcapacity5to32AMP,intheMCBDB Completewithconnectiontestingand commissioning complete all as specified and directed. |
| 141 | S&F 240V, 10 KA \"B\" curve miniaturecircuit breaker (MCB) of single poles and currentcarryingcapacitySPN 40 AMP,intheMCBDB Completewithconnectiontestingand commissioning complete all as specified and directed. |
| 142 | S&F in replacementMCB DB Single pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar withIP 43 protection 240 V nautral link, earth bar and Din rail double door complete all as specified and direcrted. |
| 143 | S&F box type LED light fitting suitable for 4 ft20 watt complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 144 | Taking down old unsrviceable bldg security light fitting, Supply and fixingnew LED bldg security light fitting 45 watts with senser to be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified. |
| 145 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanizediron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatein lieu of CI cover and frame etc allas specified and shown in electrical plate No. 5 of SSR-2009 (Part-I including testing after completion. |
| 146 | S&F decorative light fitting 1x9watt ceiling/ wall mounted LED BULKHEAD luminaire with engineering plastic housingand top frame with opal PMMA diffuser complete all as specified and directed. |
| 147 | S&F in replacement mirror LED light fitting 2 feet 10 watt with accessories complete all as specified and directed. |
| 148 | S&F PVC conduit with accessories 25 mm dia for drawing telephone/ TV/ internet wires complete all as specified and directed. |
| 149 | S&F TV socketand including sunk cast iron 1.6 mm thick pressed steel terminal box andmounting of hylem sheet its necessary fittings and accessories complete all as specified and directed. |
| 150 | Taking down existing energy meter by disconnecting clectric connection of any type ,any make ,any capacity in poly carbinate or sheet steel body, ISI marked ,50 Hz 240 volts AC single phase rating etc. complete all as specified and directed. |
| 151 | Refixing existing energy meter by disconnecting clectric connection of any type ,any make ,any capacity in poly carbinate sheet steel body with door ISI marked ,50 Hz 240 volts AC single phase/ three phase rating etc. complete all as specified and directed. |
| 152 | S&F Sheet metal enclosure TPNdistribution board vertical type double door with insulated bus bar arrangement IP 43 protection4 way 415V complete all as specified and directed. |
| 153 | S&F MCCB TPN 100 Amps 16 KA complete all as specified and directed. |
| 154 | Taking down faulty damaged unserviceable LT under ground cable of any size complete all as specified and directed. |
| 155 | Supply and laying XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100V grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed. |
| 156 | Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying underground LT XLPE cable and getting soft/loose soil complete all as specified and directed. |
| 157 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ loose soil complete all as specified and directed. |
| 158 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 159 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 160 | Supply andlayingun-reinforced pre-cast concretecablecover, butClass LV, Type I,flat,size 250mm x 150mm x 40mm complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail