Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-03-2026 |
| 2 | 17-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-02-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. But including concrete articles, complete all as specified and directed. |
| 2 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed. |
| 4 | Dismantling, floor any type, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises, complete all as specified and directed. |
| 5 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc1.5 but n. exc 4 Sqm each, complete all as specified and directed. |
| 6 | M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 7 | M & L for preparation of old plaster surface of ceiling and applying two coats of oil bound distemper, complete all as specified and directed. |
| 8 | M&L for preparing old decorated surfaces of wall scrapping machine tools /electric hand grinder with wire brushand applying two coat of oil bound distemper white or tinted with paint sprayers, complete all as specified and directed. |
| 9 | M&L for 15 mm thick rendering on fair faces of brick/stone masonary or concrete surfaces in CM(1:6)finished even and smooth without usnig extra cement, complete all as specified and directed. |
| 10 | M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil emulsion distemper over a coat of birla putty, complete all as specified and directed. |
| 11 | M & L for two coats of synthetic enamel paint over a coat red oxider primeron new steel surfaces including preparation of surfaces, complete all as specified and directed. |
| 12 | Providing & fixing false ceiling at all height with GRG (Glass Fibre reinforced Gypsum) false ceiling tile of size 595x595mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987, non combustible as per BS 476(Part4)-1970 and light reflectance of 85% (minimium) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dripped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main T-runner of size 15x32mm of length 1200mm and sectinally intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600mmx600mm, suspended from ceiling using galvanised mild steel items (galvanised @80 grams per Sqm) i.e. 50mm long,8mm outer diameter M-6 dash fastners 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partitionwith the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per direction of the Engineer- in-Charge. |
| 13 | S&F in repair solid PVC wall Lining consisting of 5 mm thick single side prelam PVC sheet includsive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed. |
| 14 | S&F of 5mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed. |
| 15 | M&L for 25 mm thick plain cement concretetype B0 1:2:4 (12.5mm graded aggregate) as in levelling course of floor and other similar works, complete all as specified and directed. |
| 16 | M&L for vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid in floors set and jointed as per manufacturer\"s instructions Over & including screed bed or bedding layer 15mm thick in CM (1:6), complete all as specified and directed. |
| 17 | All as per item No 16.00 here in before but in vertical surfaces as in skirtingincluding10 mm thickrendering in cement mortar 1:4, complete all as specified and directed. |
| 18 | S&F of glazed ceramic tiles in vertical surfaces 350x250x7mm/450x350/7mm thick set and jointed in neat cement slurry and pointed inwhite or colour cement to match rendering 10 mm thick in CM 1:4 on vertical surface as in backing coat, complete all as specified and directed. |
| 19 | M&L for Non- skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each coloured tile exceeding 0.09 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles including laying screed bed or bedding layer of mortar 15mm thick in cm 1:6, complete all as specified and directed. |
| 20 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of graniteincluding laying screed bed or bedding layer of mortar 15mm thick in cm 1:6, complete all as specified and directed. |
| 21 | M&L for factory made single extruded WPC (wood polymer composite)solid door/windows/ceosetory windows and other frames/chowkhat of size 45x70 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade),calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tocxic additives(maximum toxicity index of 12 for 100 gms)fabricated with miterjoints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum,screw withdrawal strength of 2200 N(face) & 1100 N (edge),mim compressive strength of 58 N/mm2,modulus of elasticity 900n/mm2 and resistance to spread of flame of class A category with property of being termite/boer proof,water/moisture proof and fire retardent and fixed in position with MS hold fast/lugs/ss dash fastener of required dia and length complete as per direction of engineer in charge.(MS hold fast/lugs or SS dash fastener shall be included, complete all as specified and directed. |
| 22 | S&F of factory made single extruded WPC (wood polymer composite)solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (suspension grade),calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tocxic additives(maximum toxicity index of 12 for 100 gms)fabricated with miterjoints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 650 kg/cum,screw withdrawal strength of 1800 N(face) & 900 N (edge),mim compressive strength of 50 N/mm2,modulus of elasticity 850n/mm2 and resistance to spread of flame of class A category with property of being termite/boer proof,water/moisture proof and fire retardent .WPC to be laminated with PVC foil of min 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size necessary full body threadeded star headed counter sunk SS screws,all asper directio of engineer in charge complete all as specified and directed. |
| 23 | S&F for 100 mm long stainless steel butt hinges with steel pin, complete all as specified and directed. |
| 24 | S&F for 200mm long anodised aluminiumbarrel tower bolt of extruded section, complete all as specified and directed. |
| 25 | S&F for 150mm long anodised aluminium handles, fabricated type, complete all as specified and directed. |
| 26 | S&F for 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections, complete all as specified and directed. |
| 27 | S & F for Aluminium window/ventilator (Powder coated ) double leaf /three leaf with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads, complete all as specified and directed. |
| 28 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 29 | M & L for PCC type B2, 1:2:4 using 20 mm graded crushed stone aggregate, in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering,slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 30 | M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 31 | Surface dressing n exc 15 cm deep and getting out in soft /loose soil, complete all as specified and directed. |
| 32 | Excavation in trenches not exc 1.50 m wide not exceeding 1.5 m deep and getting out in hard/dense soil, complete all as specified and directed. |
| 33 | M&L for PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in mass concrete, complete all as specified and directed. |
| 34 | M&L for nominal mix of Type B1(1:2:4) 20 mm grade crushed stone aggregates as in foundation, rafts footings, plinth beam, complete all as specified and directed. |
| 35 | Use and waste of form works to sides of concrete foundations, footing bases of columns rafts and raftswith rough finished surfaces flat, complete all as specified and directed. |
| 36 | M&L TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 37 | All as per item No 36.00here-in-before but5mm dia and over upto & incl 8 mm dia as in stirrups, complete all as specified and directed. |
| 38 | M&L for nominal mix of Type B1(1:2:4)using 20 mm graded crushed stone aggregate as in columns, pillars, piers, post and struts etc., complete all as specified and directed. |
| 39 | M&L for formworks to sides of pillar, strut, piers, columns and stancitions rough similar surface to concrete flat, complete all as specified and directed. |
| 40 | Returning filling in including spreading levelling watering and well ramming in layers in not exc.50m (soft/loose soil) |
| 41 | Removing excavated surplus soil to a distance exc. 250 m & n. exc 500 m distance, complete all as specified and directed. |
| 42 | M&L for Treating the bottom & sides of excavated trenches and pitswith foundation @ 5.00 trs. of emulsions per sqm, complete all as specified and directed. |
| 43 | M&L for Treating the top surface of filled earth @ 5 Ltrs of emulsion per sqm for floor & plinth protection, complete all as specified and directed. |
| 44 | M&L for PCC (1:5:10) type E2 using 40 mm graded crushed stone aggregate as in mass concrete, complete all as specified and directed. |
| 45 | M&L for brickwork with sub class \"B\" bricks, straightor curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 46 | M&L for nominal mix of Type B1(1:2:4) 20 mm graded crushed stone aggregate as in beams, cantilever, bressummers, lintels over 1.50 m spanand similar work etc, complete all as specified and directed. |
| 47 | M&L for nominal mix of Type B1(1:2:4) 20mm graded crushed stone aggregate in roof slabs supportedwalls beam and columns in floor roof landing, shelves etc, complete all as specified and directed. |
| 48 | Use and waste of formworks to soffits of roof slab, with rough finished surfaces flat resting on walls and beams, complete all as specified and directed. |
| 49 | M&L for Cement Plaster 10mm thick in cement mortar 1:3 under the roof treatment, water proofing treatment to roof slab with APP modified polymeric membrance and bitumen base aluminium paint over it, complete all as specified and directed. |
| 50 | M&L for PCC 1:2:4 type B0, 25mm thick as in levelling course, complete all as specified and directed. |
| 51 | M&LNon - skid Ceramic tiles 7 to8 mm thick area of eachtileexceeding 0.18 sqm but notexceeding 0.38 sqm, infloors etc. set and jointed inneat cement slurry andpointed in white or colouredcement to match laid in floors set and jointed as per manufacturer\"s instructions over & including screed bed or bedding layer 15mm thick in CM (1:6), complete all as specified and directed. |
| 52 | M&L for 15mm thick rendering on fair faces of brick or concrete surfacein CM 1:4 finished even & smooth, complete all as specified and directed. |
| 53 | M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceiling,complete all as specified and directed. |
| 54 | M&L for Preparation of new plastered surface of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 55 | M&L for Preparation of newaly plaster surface of wall and applying three coats of white wash, complete all as specified and directed. |
| 56 | M&L for Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer including balance area complete removal., complete all as specified and directed. |
| 57 | S&F in repair solid PVC door frame of size 50x47mm made out of 5mm PVC sheet reinforced with MS square tube all as specified and directed including making good to the surfaces, complete all as specified and directed. |
| 58 | S&F of factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specifications & diagram/product drawing shown on sl page NO 146 of SSR Part II with the size of door shutter as required & directed by the Engr-in-Charge. |
| 59 | S&F of 100mm Aluminum hinges, complete type B-21, complete all as specified and directed. |
| 60 | Supplying, fixing, jointing and testing galvanised iron tube, medium grade with all fitting such as bends, elbow, socket, reduce etc fixed to walls and ceiling or laid in, complete all as specified and directed floors of following sizes :- |
| 61 | (a) 15 mm dia |
| 62 | (b) 20 mm dia |
| 63 | M & L forcutting chases for concealed water tubing, pinning in, making good of facings where required and pointing in cement mortar 1:3to ends or edges etc, cutting not exceeding 10 cm width or girth, complete all as specified and directed. |
| 64 | M&L for rotational moulded polythelene water storage tank 1000 ltrs capacity double layer cylenderical vertical with closed top hoisted & fixed in position including, complete all as specified and directed. |
| 65 | S & F of ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 25 mm bore size (Minimum weight 455 gms), complete all as specified and directed. |
| 66 | S&F of 20mm bore gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified and as directed. |
| 67 | S&F in vitreous china, wash hand basin white flat back size 550x400mm white complete waste, chain and plug and procelain stopper including bracket, complete all as specified and directed. |
| 68 | S&F of Chromium plated stainless steel (Grade S-304)(heavy) grating minimum 3 mm thick of size 125mm dia for trap, complete all as specified and directed. |
| 69 | Supply and fixing of vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe)and P or S trap including connection to drain (or outgoing pipe) and to flushing pipe anti-syphonage pipe etc, complete all as specified and directed. |
| 70 | S&F of vitreous china squating pan \"Orrisa\" patern size 580x440mm white with \"P\" or \"S\" trap front or back inlet with integral foot rest (excluding flushing cistern and flush pipe), squating pan including connection to trap and flushing pipe, anit syphonic pipe etc complete incl making good to floor, complete all as specified and directed. |
| 71 | S & F of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm diapipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed. |
| 72 | S&F of PVC low level flushing cistern 10 ltr capacity complete with flush pipe of standard, complete all as specified and directed. |
| 73 | S&F of 15 mm bore bib taps, with wall flange long body, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed downscrewed for iron pipe or for brass furrel, complete all as specified and directed. |
| 74 | S&F of fancy type swan neck Pillar tap 15mm bore, cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe, complete all as specified and directed. |
| 75 | S&F of stop valve, 15 mm dia cast copper alloy, chromium plated with fancy type (angle type) screwed down, high pressure, screwed both ends for iron pipes, complete all as specified and directed. |
| 76 | M&L for PVC floor traps plain with graiting including jointing with solvent cement 75 mm bore, complete all as specified and directed. |
| 77 | S&F of PVC connection 15 mm size with PTMT nut of length 600 mm, complete all as specified and directed. |
| 78 | S&F in repair CP vitreous china soap dish fancy type, complete all as specifed and directed. |
| 79 | S&F of 600mm long fancy type towel rail with brackets etc, complete all as specified and directed. |
| 80 | S&F of vitreous china bowl urinal flat back, size of 465x355x265 mm white (minimum), (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs, fixing of flush pipe, waste pipe, grating and connection to water supply pipe, complete all as specified and directed. |
| 81 | S&F of urinal spreader of PTMT any colour for fixing with 15mm dia pipe(minimum weight 60 gms), complete all as specified and directed. |
| 82 | S&F of Vitreous china urinal partition white of size 310x700 mm.Urinal partitions slabs terminating about40cm above floor line, fixed in repairs, complete all as specified and directed. |
| 83 | S & F of PVC (SWR) pipe single socketed in any length with rubber ring, fixed on wall, complete all as specified and directed for the following sizes :- |
| 84 | (a) 75 mm bore |
| 85 | (b) 110 mm bore |
| 86 | S & F of PVC (SWR) pipe single socketed in any length with rubber ring,joints laid in trenches, complete all as specified and directed for the following sizes :- |
| 87 | (a) 75 mm bore |
| 88 | (b) 110 mm bore |
| 89 | S & F of PVC (SWR) bend, complete all as specified and directed for the following sizes :- |
| 90 | (a) 75 mm bore |
| 91 | (b) 110 mm bore |
| 92 | S & F in PVC (SWR) vent cowl, 75mm dia, including taking down existing unserviceable cowl, complete all as specified and directed. |
| 93 | Supply and fixing of 6mm thick bevelled edge looking mirror mounted on 6mm thick backing comercial plywood fixed with CP plug with chromium plated brass screws and cup washer fioxed on wall, complete all as specified and directed. |
| 94 | M&L for RCC NP3 Pipe dia 150mm bore laid and jointed with collars in cement mortar, complete all as psecified and directed. |
| 95 | M&L for PCC 1:3:6 type C2 using (40mm graded crushed stone aggregates) to drain pipes 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 96 | M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete with using extra cement including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. (inner girth only measured) |
| 97 | S&F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 98 | M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in bed plate for fixing holdfast etc., complete all as specified and directed. |
| 99 | M&L for preparation of new steel surfaces and applying two coat of steel paint including primer on steel surfaces, complete all as specified and directed. |
| 100 | S & F of Powder coated pre galvnised & Hot deep galvanised coating stainless steelperforted cable tray with SS cover chanel type ofthickness 3 mm, ht 25mm to 150mm width 50mm to 600mmincluding necessary fitting and fixture, complete all as specified and directed. |
| 101 | M&L for powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X 44.45 X 1.50mm and style 47.5 x 44.5 x1.5 mm , lock rail 83.50X 44.45 X 1.50mm and bottom rail150.00X 44.50 X 2.50mmincl necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos,aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stoper 01 Nos, 02 Nos floor spring, jointing cleats,glazing cleats,rubber packing , anodised aluminium shape beading, screws etc with panelling in two parts with12mm thick prelaminated partical board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture, complete all as specified and directed. |
| 102 | S&F of 3mm thick aluminium composite panel cladding using aluminium composite panel sheet 3mm thick (Vita 25mm aluminium foil with PVDF coating) works) and filling the gap with silicon, sealant and other materials of approved quality etc, complete all as specified and directed. |
| 103 | Taking down carefully aluminium battenpoint, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings, complete all as specified and directed.Note :- (i)Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii)Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii)Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv)Exhaust fan and ceiling fan shall be taken down in under separate item of this schedule. |
| 104 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI markedand including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:- Note : Wiring colour code i.e. Red for Phase, black for Neutral and green for earth shall be maintained. The rate included for suitable sunken metal flux box cover plate blank plates etc for placin modulat fittings etc |
| 105 | (a)For one light/fan/bell point controlled by one switch single pole one way, complete all as specified and directed. |
| 106 | (b) All as per item No 96.01here-in-before butone3 pin 5/6 amp switch socket out let in independent board, complete all as specified and directed. |
| 107 | (c) All as per item No 96.01here inbefore but one 3 pin 5 amps socket outlet on the same board with other switch, complete all as specified and directed. |
| 108 | All as per item No 96.02here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board, complete all as specified and directed. |
| 109 | All as per item No 96.02 here-in-before but using 02 Nos. 2.5 sq mm size for main cable and 01 No.2.5 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board, complete all as specified and directed. |
| 110 | Supply and fixing of switch modular flush 6/10A single pole one way ISI marked (One module), complete all as specified and directed. |
| 111 | Supply and fixing of switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked, complete all as specified and directed. |
| 112 | Supply and fixing of modular sockets 6 Amp 2 in 1 2/3 pin combined (Two module), complete all as specified and directed. |
| 113 | Supply and fixing of modular sockets 16Amp 2 in 1 3/5pin combined (Two module), complete all as specified and directed. |
| 114 | Supply and fixing of ceiling rose surface bakelite 60x25mm three terminal 240 V grade complete all as specified and directed by Engr- in-Charge. |
| 115 | Supply and fixing of electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type, complete all as specified and directed. |
| 116 | S&F of LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, system lumen efficiency >90 lumen/watt, 6500kandincluding connectingfrom ceiling rose to fitting, completeallas specified and directed. |
| 117 | S&F of LED batten luminaire surface mounted 2 feet system wattage of 10 watts system lumen efficiency >90 lumen/watt, 6500kand including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed, complete all as specified and directed. |
| 118 | Supply and fixing of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 119 | S&F of LED batten extruded surface mountingfitting 2 feet long aluminium housing 10 wattinput voltage 220 volt in built LED and driver, complete all as specified and directed. |
| 120 | Supply and fixing of Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan, complete all as specified and directed. |
| 121 | S & F of LED light fitting 10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 122 | Supply and fixing of connecting and testing LED street light 35 watt 6000k/3000k new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high efficient led as lighting source and PC cover having toP opening seperate driver compartment with IP66 protection and impact resistance of IK07 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting, complete all as specified and directed. |
| 123 | Supply & fixing of MCB DB SPN 8 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, complete all as specified and directed. |
| 124 | Supply and fixing of MCB, single pole and neutral, 230 volts, 32 Amp rating, \"C\" series fixed in DBs catered here-in-before, complete all as specified and directed. |
| 125 | Supply and fixing of MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve, complete all as specified and directed by Engineer-in-Charge. |
| 126 | Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia asearth lead wire by means of brazing of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. complete all as specified and directed. Notes(i)The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I(ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire andGI pipe for protection of earth wire. Any varriation in quantity shall be adjusted. |
| 127 | Material, labour for jointing & testingXLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable, complete all as specified and directed. |
| 128 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning, complete all as specified and dierected. |
| 129 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection, complete all as specified and directed. |
| 130 | Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia, complete all as specified and directed. |
| 131 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy