| 1 | Rough excavation not exceeding 1.50m deep and getting out in any type of soil, complete all as specified & dircted. |
| 2 | M&L for removing excavated material (soil) not exceeding 50M and deposting where directed at a level not exceeding 1.5m above the starting point Complete, all as specified and directed.. |
| 3 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed . |
| 4 | M&L for plain cement concrete 1:2:4 type B-0 (Using 12.5mm graded aggregate)as in roof padding and similar works mixed with Polymer based intergral water proofing liquid admixture as per manufacturer\"s instruction, complete all as specified and as directed. (Note :- Polymer based water proofing compund shall be measured and paid seperately) |
| 5 | M&L for bonding agent suitable for bonding new to old concrete surface, applyingas per manufacturer\"s instructions complete all as specified and as directed . |
| 6 | Supply only Polymer Based Integral waterproofing liquid admixture mixed in concrete, plaster and mortar applyingas per manufacturer\"s instructions complete all as specified and as directed. |
| 7 | M&L for rendering 10 mm thick on fair faces of brick or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound as per manufacturer\"s instruction in cement, rendering is to be finished even and smooth (without using extra cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane, complete all as specified and as directed . Note: Cost of WPC in cement shall be included in quoted rates. |
| 8 | S&F in repair 12 Mesh size wire netting of galvanised steel wire, 1.23 mm dia complete all as specified and as directed. |
| 9 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 10 | M&L for hand packing broken stone or boulders (any thickness) at back of walls over arches ete and raising (or lowering) to the required level complete all as specified and directed. |
| 11 | S&F in repair 4mm dia galvanised steel wire, 150x 100mm mesh, made up into mettresses or cages, laped, wired and laid in position, including closing after filling complete all as specified and directed. |
| 12 | S&F in repair UPVC pipes (SCH-40) in roof perapet wall dia 100mm for rain water drain complete including bend and clamps, complete all as specified and directed |
| 13 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed. |
| 14 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., exc. 1.5 m high but n exc 3.0 mtr from base complete all as specified and directed. |
| 15 | M&L for forming embankments including raising (or lowering) earth by using good earth free from debris, brought from outside MoD land, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed. Note : For srl item no. 13 to 15 ,cost of good earth brought from outside MoD land shall deemed to be included in quoted rates |
| 16 | Demolition of brickwork or stone / boulder masory built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified. |
| 17 | M&L for brick work with sub class \"B\" old size bricks straight or curved on plan exe 6 metre mean radius built in cement mortar 1:6 all as specified & directed by Engr-in-charge |
| 18 | M&L for brick work with sub class \"B\" old size bricks, but except bricks, straight or curved on plan exe 6 metre mean radius built in cement mortar 1:6 , complete all as specified & directed by Engr-in-charge. |
| 19 | M&L for preparation of old concrete or brick surface by complete removal of existing treatment, removing all loose particles, applying 1st coat of Dr. fixit Pidifin 2K or equivalent, after 6 to 8 hrs of completion of 1st coat apply 2nd Coat in a direction perpendicular to 1st coat, coverage area as per manufacturer\"s instruction ,complete all as specified and as directed by Engineer-in-Charge |
| 20 | Taking down cement or cement lime plaster on brick or stone walls, etc including raking out joints, hacking for key, scurbbing down with water, etc complete all as specified |
| 21 | M&L for rendering 15mm thick on fair faces or concrete surface in cement mortar 1:4 is to be finished even and smooth (With out using extra cement) complete all as specified. |
| 22 | M&L for rendering 10mm thick on fair faces or concrete surface in cement mortar 1:4 is to be finished even and smooth (With out using extra cement) complete all as specified. |
| 23 | M&L for rendering 5 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces,and ceilingfinished even & smooth without using extra cement. |
| 24 | M&L for extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work not exceeding 15 cm in width or girth; including cutting to edges, all mitres and stopped ends,etc. complete all as specified and directed. |
| 25 | Demolition of unreinforced cement concerte of any description and any position not otherwise specifically provided for complete all as specified and directed. |
| 26 | M&L for providing cement concrete type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for, water throughs and the like including weathering, slightly rounded or chamfered angles and thoating complete all as specified and directed. |
| 27 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of alkali resistant primer, complete all as specified and as directed . |
| 28 | M&L for preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls including complete removal of existing treatment and applying two coats of distemper oil emulsion over one coat of alkali resistant primer over, complete all as specified and as directed. |
| 29 | M&L for preparing newly plastered or unplastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed. |
| 30 | M &L for preparation of new surfaces of walls plastered surface, priming with alkali resistant primer and applying two coats of exterior emulsion paint in camouflage pattern complete all as specified and as directed . |
| 31 | M &L for complete removal existing treatment from old surface of walls and applying two coats of exterior emulsion paint (Apex Ultima or equivalent) in camouflage pattern, over one coat of alkali resistant primer including preparation of old surfaces, complete all as specified and as directed. |
| 32 | M&L for preparing old plaster surface of celling and applying one coat of white wash, complete all as specified and as directed. |
| 33 | M&L for preparation of old painted steel and iron surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 34 | M&L for grassing with pusa selecton No-1 type grass including watering and maintenance of berm lawn till completion weeds and fit for moving including fine dressing of ground in required level and flooding with water and the component mentioned should includeChemical fertilizers and vermi compost etccomplete all as specified and directed. |
| 35 | Supply and fixing in repair test point terminal block made of gun metal or phosphours bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8mm dia and 25mm long hexagonal head screw, complete all as specified and directed. |
| 36 | Supply and fixing in repair of aluminimum strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors, complete all as specified and directed. |
| 37 | Supply and fixing in repair Air termination ,single pointed aluminimum rod 12mm dia and 300 mm long, complete all as specified and as directed . |
| 38 | S&F in repair tubes, \"medium grade\" galvanised, 40mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed.Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates. |
| 39 | S&F in repair tubes, \"light grade\" galvanised, 40mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed.Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates. |