| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, wooden window shutter , Mild steel window and Mild steelventilators(without taking off shutters from the frames)areanot exceeding 1.50 sqm eachcomplete all as specified and asdirected by Engineer-in- charge. |
| 2 | Supply & fixingFactory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame /cupboard frame/ Chowkhat of Size 45mm x 70 mmcomprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximumtoxcity index of 12 for 100 gms )fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmmmodulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A categorywith property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fastlugs / SS Dash Fastner of required dia and lengthwith and including Supply & fixing(03 Nos Per Frame ) 100 mm long SS Butt Hinges withand making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4complete all as specified and asdirected by Engineer-in- charge. |
| 3 | Supply & fixingFactory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and includingSupply & Fixingof 02 Nos (per Leaf) SS 150mm long Tower Bolt withStainlessd steel screwsand including Supply & fixing of 02 NosSS 150mm long handle with Stainlessd steel screws and 300 mm SS sliding door bolt with Stainlessd steel screwscomplete all specified and directed by Engineer -in-charge. Note:- The rate of 02 Nos.SS 150mm long Tower Bolt . 02 Nos.SS 150mm long handle and 300 mm SS sliding door bolt is included in this item and nothing shall be paid extra on this account. |
| 4 | Taking down chowkhats or frames with shuttersof PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steelventilators(without taking off shutters from the frames) areaexceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and asdirected by Engineer-in- charge. |
| 5 | Supply and fixingPressed steel frames for doors with one or more rebates with and includinglock strike plate, fixing lugs, etc., size of frame 125mm x 60mm,with and including one shop coat of zinc chromate primercomplete all as specified and as directed by Engineer-in-charge. (thickness of steel sheet shall be 1.25mm) Note:- 1.The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6 and matching the colour of new plaster with existing surface. Nothing extra shall be paid on this account.2. The rate of one shop coat of zinc chromate primer is included in this item and nothing shall be paid extra on this account. |
| 6 | Supply and fixingPressed steel frames for doors with one or more rebates with and includinglock strike plate, fixing lugs, etc., size of frame 105mm x 60mm,with and including one shop coat of zinc chromate primercomplete all as specified and as directed by Engineer-in-charge. (thickness of steel sheet shall be 1.25mm) Note:- 1.The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6 and matching the colour of new plaster with existing surface. Nothing extra shall be paid on this account.2. The rate of one shop coat of zinc chromate primer is included in this item and nothing shall be paid extra on this account. |
| 7 | Material and Labour PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for filling in bed block of hold fast etc complete all as specified and as directed by Engineer-in-charge. |
| 8 | Supply & fixing factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and as directed by Engineer-in-charge. |
| 9 | Supply and Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (Bonsum/ Hollock) edges of frming plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge.Note:- Wire gauze/ glass shall be measured and paid separately.Note : -(i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ. |
| 10 | Supply & fixingStainless steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm all as specified and as directed by Engineer-in- charge. |
| 11 | Supply & fixing 300mmmild steel ordinary rat tail rodsprings (helical spring) CONFORMING TO is 452-1973 , including roller & roller plate, fixed with screws/welding to steel frames/chowkats, complete all as specified and as directed by Engineer-in- charge. |
| 12 | Supply and fixing stainlesssteel barrel tower bolts, 200 mm long conforming to IS 15833-2009, with bright bolts and fixed complete all as specified and as directed by Engineer-in-charge. |
| 13 | Supply & fixing 300mm longstainless steel sliding door bolts confoming to IS 15834-2008 , plate type,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed length of bolt complete all as specified and as directed by Engineer-in- charge. |
| 14 | Supply and Fixing type 3 stainless steel door handle of size 150 mm conforming to IS 208-2020, fixed with countersunk conforming to IS 208-2020 complete all as specified and as directed by Engineer-in-charge. |
| 15 | Supply & fixing floor door stopper 150mm size of aluminium alloy body and tounge, anodised, with hard drawn steel spring complete all as specified and as directed by Engineer-in- charge. |
| 16 | Material and labourfor Providing and fixing aluminium work with Polyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micronfor doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conformikng to IS:733 and IS :1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions i.e at top , bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth , rust free, straight, mitred and jointed mechanically wherever required including aluminiumcleat angle, aluminium snap beading for glazing/ paneling , C.P. brass/ stainless steel screws, all complete all as specified and directed by Engineer-in-charge .Note :- (i) Weight of aluminium sections , aluminiumcleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminiumpeg stays &aluminium snap beading shall be physically ascertained through a board of officers convened by GEand payment shall be made only after ascertaining the actual weightof aluminium at site.(ii) The rate of material and labour for providing theEPDM rubber, neoprene gasket , C.P. brass / stainless steel screws are included in this item and nothing shall be paid extra on this account.(iii) During considering the weight of aluminium sections , aluminiumcleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminiumpeg stays &aluminium snap beading, the weight of EPDM rubber, neoprene gasket , C.P. brass/ stainless steel screwsshall not be considered formeasurments and payments. Onlythe weightof the aluminium sections ,aluminiumcleat angles, aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminiumpeg stays &aluminium snap beading shall be considered andmeasurment and payment shall be made accourdingly.(iv) During the weight of aluminium sections , aluminiumcleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts ,aluminiumpeg stays &aluminium snap beading ,the weight of polyester powder coating 50 micron shall not be considered for weight but the rate of material and labour for providing polyester powder coating 50 micron is included in this item and nothing shall be paid extra on this account.(v) Glazing /Panelingand wire mesh shall be measured and paid seperately. (v)The board shall be duly countersigned by GE shall enclosed with Final Bill . |
| 17 | Supply & fixingMild steelFramed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engineer-in-charge. |
| 18 | Supply & fixing 4.0 mm thick,sheet glass ordinary quality fixing with oil putty to steel surfaces not exceeding0.50 sqm in each pane complete all as specified and as directed by Engineer-in- charge. |
| 19 | Supply & fixing4.00 mm thick,figured glass, pin head type notexceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in- charge. |
| 20 | Material and Labour for preparation of new steelsurfacesof any description over 10cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed by Engineer-in-charge. |
| 21 | Material and Labourfor preparation of old painted steel surfaces of any description not otherwise described over 10 cmwidth & girth by applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge. |
| 22 | Material and Labour preparing New wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-charge. |
| 23 | Material and Labourfor preparation of old painted wooden surfaces of any description not otherwise described over 10 cmwidth & girth by applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge. |
| 24 | Demolition of cement concrete un- reinforced of any description and in any position not otherwise specifically provided for and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge |
| 25 | Supply only Liquid water proofing compoundcomplete all as specified and directed by Engineer-in- Charge. |
| 26 | Material and labour for Waterproofing treatment to sunken floor using acrylic based multipurpose polymer.The treatment shall be carried out as per manufactures specification. The treatment shall be include of the following elements also: 1. Surface preparation of substrate by removing all traces of contaminates, loose and friable particles, cement laitance oils and grease, water repellent coatings etc2. Injection grouting using cementitious grout if required. The payment for injection grouting shall be made separately etc.3. Repair to the substrate, filling of blow holes/voids and surface leveling using appropriate products specified by the manufacture.4. All intersections of horizontal and vertical surface should be profiled with a mortar fillet of minimum 25mm x 25mm.5. The moisture content of the substrate shall be checked before application of first coat at water proof coating at the rate of 200 g/m2 followed brush topping at 450g/m2 per mm. The second coat shall be reinforced with glass fabric between the first and second coat.6.The treatment shall be protected by application of polymer modified cement mortar of thickness 10mm applied at the rate of 50g per mm.7. Tech specification : Tensile adhesion strength 0.5N/Sqmm (as bonding slurry). |
| 27 | Material and LabourFor 30mm thick cement concrete (1:2:4) type B0 using12.5mmgraded stone aggregates as in floor, Sunken floor etc Finished rough to receive tiles including mixWPC as per manufacturer\"s instructioncomplete complete all as specified and as directed by Engineer-in-charge. Note : WPC shall be measured and paid separately. |
| 28 | Material and labour for Aerated Autoclaved Concrete (AAC) blocksworkaccording to Indian Standard specification IS:2185(Part-3)-1984 and latest revisionbuilt in Cement and sand mortar 1:6 with Aerated Autoclaved Concrete (AAC) blocksstraight or curver on plan exceeding 6mtr Mean radius as in sunken floor complete all as specified and and as directed by Engineer-in-charge. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing )including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Material and Labour anti slip coloured ceramic tiles 7 to 8mm thick (square/rectangular) of Size 400mmx400mm Sqmin floorsincluding 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile includingnecessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge. |
| 31 | Supply and Fixing glazed ceramic coloured tiles7.5 mm to 8.5mm thick 450mm x 300mm size in verticle surface including 10mm thick backing coat using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile includingnecessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge. |
| 32 | Roughning surfaces of Old concrete floor by picking sweepoing clean and washing down with water to remove dust etc complete all as specified and as directed by engineer-in- charge. |
| 33 | Material and Labour for abrasion resistant ceramic tiles, area of each tile exceeding 0.18 Sqm but not.exc 0.38 sqm, 9-10mm thick (Square, Polished, Shade colour as approved by GE, in floor etc set and including 10mm thick bedding layer using type -I adhesive (thick bad fixing )conforming to IS 15477:2004 and pointed in white cement or colour cement to match the shade of tile including nrecessary citting as per site requirement having scratch hardness of the surfaces min 6 on Mohs Scall and abrasion resistance of class V Complete all as Specifiedand directed by engineer-in-charge. |
| 34 | Material and Labour for abrasion resistant ceramic tiles, area of each tile exceeding 0.18 Sqm but not.exc 0.38 sqm, 9-10mm thick (Square, Polished, Shade colour as approved by GE, on vertical Surfaces as in Skirting/Dado etc set and including 10mm thick renderingand using type -I adhesive (thick bad fixing )conforming to IS 15477:2004 and pointed in white cement or colour cement to match the shade of tile including nrecessary citting as per site requirement having scratch hardness of the surfaces min 6 on Mohs Scall and abrasion resistance of class V Complete all as Specifiedand directed by engineer-in-charge. |
| 35 | Material & Labourfor Mirror polished kota stone slab as approved by GE 18-20mm thick laid over grey cement slurry @ 3.00kg per Sqmas in flooring, cills and stair caselaid over with and including 15 mm thickcement screed base in CM 1:4 laid and jointedmixed with pigment to match the shade of the slab complete all as specified and as directed by Engineer-in-charge. |
| 36 | Material & Labourfor Mirror-polished kota stone 18-20mm thick in riser of steps, skirting, dado and pillar and laidwith and including grey cement slurry@ 3.00kg per Sqm laid over with and including10 mm thickcement plaster in CM 1:4, laid and jointedmixed with pigment to match the shade of the slab complete all as specified and as directed by |
| 37 | Supply & fixing600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge. |
| 38 | Supply and fixing in repairs Stop valve / angle valve , cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule for 15 mm bore dia of pipe complete all as specified and as directed by Engineer-in- charge. |
| 39 | Supply & fixing in repairs chromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge. |
| 40 | Supply & fixing in repairs 15mm bore concealed stop cock cast copper alloy,chromium plated, fancy type, long shank and cup, screwed both ends suitable for iron pipe complete, all as specified & directed by Engineer-in-charge. |
| 41 | Supply & fixing in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flangescomplete all as specified and as directed by Engineer-in-charge. |
| 42 | Supply & fixing in replacementchromium plated stainless steel , soap tray size not less than 160mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engr-in-Charge |
| 43 | Supply and fixing in replacement 15mm bore Bib tap long bodycast copper alloy, chromium plated , with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 44 | Supply and fixing 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame alround made of PVC channel, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fixing 1200mm x 600mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame alround made of PVC channel, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and Fixing 19mm internal dia Stainless steel drapery rod with bracket incl wall and other side fancy knobs at both ends as approved by GE including taking down old existing rod/pelmet with accessories complete all as specified and directed by Engineer-in-charge. |
| 47 | Supply and Fixing 20 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 20mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge. |
| 48 | Supply and Fixing 25 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 25mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge. |
| 49 | Supply and Fixing 32 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 32mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge. |
| 50 | Supply & fixingin repair wash hand basin of size 550mm x 400 mm vitrous China white flat back including brackets, waste coupling & PVC Waste Pipe of 32mm dia etc complete all as specified and as directed by Engineer-in-charge . |
| 51 | Material and Labour in replacementvitreous chinaurinal of size 410mm x 380mmx 950mm, half stall type white, with grating and union for discharge pipeincluding CP urinal spreader and CP connection and waste pipe complete all as specified and Engineer-in-Charge. |
| 52 | Supply & fixing 110 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any length withlaid in trenchescomplete all as specified and as directed by Engineer-in- charge. including Taking down old PVC eaves gutter and rainwater pipes ( of any size and pattern) including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 53 | Supply & fixing 110 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any lengthas shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD-917 sheet sheet 1/1 of staysfixedto wall at a distance of 100-120mm away from wallscomplete all as specified and as directed by Engineer-in- charge. including Taking down old PVC eaves gutter and rainwater pipes ( of any size and pattern) including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 54 | Supply & fixing110 mm bore, PVC (SWR) fittings Type -Bsuch as bends, tee, \"Y\" etc ; fixed to PVC pipes,complete all as specified and as directed by Engineer - in-charge. |
| 55 | Supply & fixing 75mm bore of pipe PVC (SWR) type B ring fitpipes single socket in any lengthas shown in BTD Drg No. 916 sheet 1/4 to 4/4of stays to wall at a distance of 100-120mm away from walls( of any size and pattern) including Taking down old PVC eaves gutter and rainwater pipes ( of any size and pattern) including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 56 | Supply & fixing75 mm bore, PVC (SWR) fittings Type -Bsuch as bends, tee, \"Y\" etc ; fixed to PVC pipes,complete all as specified and as directed by Engineer - in-charge. |
| 57 | Supply & fixing110 mm bore, PVC (SWR) fittings Type -B\"P\" Trap , with grating including jointing to waste pipe with solvent cement complete all as specified and as directed by Engineer - in-charge. |
| 58 | Supply & fixing75 mm bore, PVC (SWR) fittings Type -B floor Trap , with grating including jointing to waste pipe with solvent cement complete all as specified and as directed by Engineer - in-charge. |
| 59 | Supply & fixing 110 mm dia PVC(SWR) Type -B branch fittings Type -B piece, single (single Y) equal or unequalbranch piece single ( equal or unequal), ordinary or invertedor with parallel branches complete all as specified and as directed by Engineer-in-charge. |
| 60 | Supply & fixingin repair Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. |
| 61 | Supply & Fixingin replacementvitreous China squatting pan of Orrissa pattern of approved make of size 580 mm x 440 mm x 260 mm white with integral foot restsincluding connection to trap and to flushing pipe including lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and as directed by Engineer-in- charge. |
| 62 | Supply & fixingin replacement vitreous china wash down water closet pan (pedestal pattern, EWC) P Trap white clour , including connection to drain etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge. |
| 63 | Supply and fixing in replacement 10 litres capacityPVCvalveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handleincluding brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge. |
| 64 | Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified and directed by Engineer-in- charge. |
| 65 | Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof disposal off rubbish upto a distance not exceedomg 500.00mtrwhere directed ) complete all as specified and directed by Engineer-in- charge. |
| 66 | Material and Labour for Water proofing tratment to existing roof / terrace (material of water proof treatment as approved by GE) Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include the followings:(a)Preparation ofsubstrate and cleaning it off all loose and triable by mechanical means(b)Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant.(c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm.(d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat.(e)The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm.(f)The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIALTensile Strength 1.5 MPa ASTM D412Elongation at Break > 200% ASTM D412Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305Permeability to Water Vapour Passes IS 2645Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96Water Absorption < 10% ( by Mass) ASTM D570Microbiological Resistance No Algae & Fungal Growth ASTM D5590Solar Reflectance Index 102 ASTM E1980.Note : Complete material shall be approved by GE andprocured in bulk and kept in lock and key.Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer in consultation with GE. |
| 67 | Material and Labour for PCC padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair and maintain roof slope during the execution of work including Liquid water proofing compound complete all as specified and directed. Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule \"A\" BoQ. |
| 68 | Taking down cement plaster of any description, any thickness from internal and external surfaces of walls/soffits / chajjas/parapet walls /ceiling etc .incl raking out joints, hacking for keys, scrubbibg down with water etc and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge |
| 69 | Material and Labour forCement plastering 10mm thick in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished fair & even without using extra cementcomplete all as specified and directed by Engineer-in- Charge. |
| 70 | Material and labour for 15mm thick rendering in 1:6 Cement Mortaron brick /concrete of wall surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.. |
| 71 | Material and labour for 15mm thick rendering in 1:4 Cement Mortaron brick /concrete of wall surfaces including finishing the surfaces even and smooth(without using extra cement complete all as specified and directed by Engineer-in-charge. |
| 72 | Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specifiedand as directed by Engineer-in- charge. |
| 73 | Material and Labour Brick work with sub class ‘B’ burnt clayold size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in- charge. |
| 74 | Material and Labour 75mm thick PCC 1: 3: 6 type C-1 ( using 20mm graded stone aggregate ) in plinth protection, including finishing the surface even and smooth without using extra cement.by Engineer-in-charge. |
| 75 | Demolition of RCC of any description and any position not otherwise specially provided and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance not exceeding 500 metresaway from the site complete all as specified and as directed by Engineer-in-Charge..Note:The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. |
| 76 | Material and Labour for RCC 1:2:4 ( Nominal Mix ) type B1 using 20mmgraded stone aggregate as in chajjas complete all as specified and directed by Engineer-in-charge.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 77 | Material and labour for Formwork to chullah hoods , troughs and similar items including edges onrough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 78 | Material and Labour for MS TMT bars 10mm diaand over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etccomplete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 79 | Supply & fixing in repairs Rotational MouldedPolyethylene water storage tankISI Marked of capacity 1000 litres (cylindrical vertical, with closed top), hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed by Engineer-in-charge. (Note :- Ball valve and gate valve shall be measured & paid separately under appropriate items of Schedule \"A\" BoQ.) |
| 80 | Supply and FixingBall valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge. |
| 81 | Material and Labour forpreparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before usecomplete all as specified and directed by Engineer-in- Charge. |
| 82 | Material and Labour forpreparingof old decorated(Plastered / unplastered ) surfaces of ceilingsandwith and including applying acrylic wall care putty(thickness vary from 1.5 to 2.5 mm )as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving white wash with and including applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge. |
| 83 | Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grindercomplete all as specified and directed by Engineer-in- Charge. |
| 84 | Material and Labour for applying acrylic wall care putty oninternal surfacesand external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etccomplete all as specified and directed by Engineer-in- Charge.Make of acrylic wall carePutty : AS described inLIST OF MAKES/MANUFACTURERS under Appendix \"B\" here-in-after.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. (ii)The make of acrylic wall care putty shall be as per the recommendation of manufacturer of paint. |
| 85 | Material and Labour for prepration of surfaceswith and including applying 02 coats of Interior AcrylicEmulsion Paint (shade as approved by GE ) , @ 10.00 Sq.m/ litre /2.00 coats by using roller to internal wall surfaces over with andincluding onecoat of Interior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Interior Acrylic Emulsion by using thebrands of Interior Acrylic Emulsion Paint and Interior Acrylic Emulsion Primer as described inLIST OF MAKES/MANUFACTURERS under Appendix \"B\" here-in-aftercomplete all as specified and directed by Engineer-in- Charge. |
| 86 | Material and Labour for prepration of surfaceswith and includingapplying 02 coats of Exterior Acrylic Emulsion Paint (shade as approved by GE) with highlighter of any approved shade,@ 5.00 Sq.m/ litre / 2.00 coats by using roller to External walls / RCC surfaces / Soffits of Chajjas / Roof projections / Cantilevers / Balcony etc. surfaces over with andincluding onecoat of Exterior Acrylic Primer @ 11.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Exterior Acrylic Emulsion by using the brands ofExterior Acrylic Emulsion Paint and Exterior Acrylic Emulsion Primer as described inLIST OF MAKES/MANUFACTURERS under Appendix \"B\" here-in-aftercomplete all as specified and directed by Engineer-in- Charge. |
| 87 | Supply & Fixing 4mm Wire for laying mosquito nets in OR line, fixing with angle and provide necessary arrangement for lightning of GI wire complete all as specified and directed by Engineer-in- Charge. |
| 88 | Supply and fixing in repairs 15mm bore Swan Neck type Pillar taps, cast copper alloy, with capstan heads,chromium plqated, fancy type, screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr In Charge |
| 89 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clipsand providing and fixing new onescomplete all as specified and directed by Engineer-in- Charge. |
| 90 | Material & Labour4.0mm thick Sheet glass,ordinary quality and glazing with oil putty in square exceeding0.50 sq. m in each pane complete all as specified and directed by Engineer-in- Charge.. |
| 91 | Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform /cooking plateform , steps, jambs,pillars, window cills, , shelves, urinal partitionand like , including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement(1:2)using marble dust with admiture of pigmentto matchwith shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge. |
| 92 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits,manholes , septic tank, for laying of cables , laying of pipesnot exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specifiedand as directed by Engineer-in- charge. |
| 93 | Demolition and Breaking of Drain Pipes SGSW, AC reinforced concrete pipe of 150 mm bore pipes complete all as sp[ecified and directed by Engineer-in- charge.complete all as specified and as directed byEngineer-in-Charge . |
| 94 | Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed ofdrain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :-(i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm. |
| 95 | Supply and laying DWCPE (SN 8) drain pipes 150 mm nominal dia as per IS-16098 (Part-II), laid in trenches on bed including all accessories/ fittings/ jointed ring, jointing and testing complete all as specifiedand as directed by Engineer-in- charge.Note:- Excavation , earth work, bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch \"A\" |
| 96 | Material and labour forcement concrete (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 97 | Material and labour forcement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in benching of Manholes, Coping etc. etc complete all as specified and as directed by Engineer-in-charge. |
| 98 | Supply and fixing SFRC (steel fibre Reinforcement concrete cover & Frame ) Heavy Duty HD-20, Grade designation 650mm internal diameter conforming to IS -12592, graded rectangular clear Opening 700mm x 700mm, total weight of cover and frame not lless than 182 Kg fixed in cement concrete (1:2:4) etc complete all as specified and as directed by Engineer-in-charge. |
| 99 | Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge. |
| 100 | Removing excavated material (Soils ) exceeding 50m and not exceeding 500m depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 101 | Material and Labour forCutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required forInternal dia of pipe in 150 mm complete all as specified and as directed by Engineer-in-charge. |
| 102 | Dismantling R.C.C posts or struts and Mild steelangle iron post and angle iron struts ofany section, including taking outembedded portion Concrete, brick work, masonry, etc.and making good disturbed ground complete all as specified and directed by Engineer-in- charge. Note:1.The weight of scrap iron in kilogram for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.2. The rate of taking out from concrete embedded portion is included in this item and nothing shall be paid extra on this account. |
| 103 | Dismantling offencing wire mesh, including round bar , Mild steel flat iron, nuts, bolts ,washers etc. any type complete all as specified and directed by Engineer-in- charge. Note:The weight of scrap iron in kilogram for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. |
| 104 | Material and Labour for Excavating in post holes (or similar holes) each not exceeding0.5 cu. m, in soft / loose soil and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and consolidation , removing surplus soil to a distance not exceeding 50 mtr and making good distrubed ground completeall as specified and directed by Engineer-in-Charge. |
| 105 | Supply andfixing Mild steel work ofFe-290 Gde E -165 as in angle ironfencing posts &flat irondrilled and countersunk for boulders running bars,including embedding in concrete and scruing etc,post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc,flat iron fillets (for securing wire mesh etc.) Including all necessary drilling,bolting or riveting etc.complete all as specified and directed by Engineer-in-charge. Note:- (i)The element of Fixing of round bars for chain link fencing is included in this item .Nothing shall extra be paid on this account ..complete all as specified anddirected by Engineer-in-charge. (ii) concrete work for embeding shall be measured and paid seperately under respective item of Schedule\"A\" BoQ. |
| 106 | All as per serial item no. 105.00 here--in before except angle iron including embedding in concrete and scruing etc,post and struts in fencing. Note:- (i)The element of Fixing of round bars for chain link fencing is included in this item .Nothing shall extra be paid on this account ..complete all as specified anddirected by Engineer-in-charge. (ii) concrete work for embeding shall be measured and paid seperately under respective item of Schedule\"A\" BoQ.(iii) old servicable angle iron shall be retrived from serial item no.102.00 here-in-before. |
| 107 | Supply only 10mm dia MS round bar for fixing of chain link fencing with post complete all as specified and directed by Engineer-in-charge. Note :-Fixing element of this item is included in serial item no. 105.00 & 106.00 here-in-before. |
| 108 | Supply & fixing Mild steel screw bolts (machine made) 5 to 10mm diawith hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longcomplete all as specified and as directed by Engineer-in-charge.Note:The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. |
| 109 | Supply only chain link fencing, galvanised mild steel of mesh of any size any type complete all as specified and directedby Engineer-in-charge. .Note : The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be paid accordingly. BOO duly counter signed by GE shall be enclosed with final bill. |
| 110 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in- charge. ( Note :-(i) supply only Chain linkfor fencing will be measured and paid separately).(ii) The rate of binding wire for fixing of chain link fencingis included in this item and nothing shall be paid extra on this account. |
| 111 | Dismantling interlocking paver blockcomplete all as specified and directed by Engineer-in-charge. |
| 112 | Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade colour and pattern as approved by GE with grey cement and pigmentcomplete all as specified and as directed by the Engineer-in-Charge. |
| 113 | All as per Item No-112.00 here-in- before but except Interlocking Paver blocks .Interlocking Paver blocks shall be reterived from serial Item No -111.00 here -in -before for using under this item complete all as specified and as directed by the Engineer-in-Charge. |
| 114 | Material and labour for 25mm thick Sand filling under interlocking tiles including watering andconsolidationcomplete all as specified and as directed by the Engineer-in-Charge.Note: Sand shall be approved by GE before incorporation in the work. |
| 115 | Material and labour for 75 mm thickcement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate as in sub base of floor. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 116 | Supply and Fixing Mild steelFramed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) andhanging; also fastening and fixing complete complete all as specified and directed by Engineer-in -charge. |
| 117 | Material and Labour for Earth filling in Traverse including watering and consolidation complete all as specified and as directed by Engineer-in- charge. Note: Earth for filling in Traverse shall be obtained from the out side of MOD land and necessary record shall be maintained properly.No earth for filling shall be used of MOD Land. Necessary certificate that earth for filling in traverse is brought from MOD Land duly signed by GE shall be enclosed with final bill. |
| 118 | Forming embankment in soft/loose soil including raising (or lowering)earth,spreading in layers not exc 30 cm thick, watering/rolling with 8 to 10 Tonn power roller and finishing to reqdsize, shape etc .not exc 1.50 mtr high form the starting point on 95% standard proctor density complete all as specifiedand as directed by Engineer-in- charge. NOTE: (i) The compaction of earth filling is to be carried out under optimum moisture condition with 95% of Standard Proctor density. (ii) Rate of Earth filling as material and labouris not included in this item. Earth filling shall be provide under serial item no.117.00of BoQ here-in-before. |
| 119 | Material and labour for Prepacked polymer modified mortar combining cement with selected grades of sand and several admixtures plaster 15mm thick (Average thickness)complete all as per manufacturer\"s instructions with and including skim coat as directed by Engineer-in-charge andincluding necessary scaffolding as directed by Engr-in-Charge. Notes :(i) Prepacked polymer modified mortar combining cement with selected grades of sand and several admixturesshall be measured and paid seperatelyas supply only under serial item No. 120.00 of Schedule \"A\" BoQ here-in-after.(ii) The labour element for laying of Prepacked polymer modified mortar combining cement with selected grades of sand and several admixtures is included in this item and nothing shall be paid extra on this account.(iii) The rate of providing and layingskim coat as directed by Engineer -in-charge is included in this item and nothing shall be paid extra on this account. (iv) The rate of scaffolding is also included in this item if required at site and nothing shall be paid extra on this account. |
| 120 | Supply onlyPrepacked polymer modified mortar combining cement with selected grades of sand and several admixtures for use as brick plaster and brick adhesive having minimum comprssive strength of ̴ 6N/ mm²complete all as per manufacturer\"s instruction and directed by Engineer-in-Charge.Note: Make shall be approved by GE. |
| 121 | Material and Labour for Drilling Holes of 12mm dia up to 100 mm deep holes in slab at the interval of300 mm or as directed by Enginner-in-charge in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injectorandhavingmachinedexternalendtoreceiveoutletofGroutingGun.Fixinsidetheholeby applyingthixotropicepoxyadhesivetoensurecompletesealingandallowcuringthesystemfor minimumof8HrsbeforeGroutingincludingnozzleprojections,excessputty,ifany,overconcrete elementbygrinding,levelingandfinishingtheexternalsurface,aftercompletionofthework,etc. complete all as specified and as directed by Engineer-in-charge. |
| 122 | SupplyandGrouting,injectingtwopart,low viscosity,moistureinsensitiveinjectionliquid,basedon highstrengthepoxy resinby pressureandusing pressureepoxy injectorwith accessoriestill nozzle refused to accept the grout including mixing of grout for column, beam and roof slab having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250mPas at +30°C and should comply accordingtoASTMC881,TypeIIandIV,Grade-1,ClassE+F(ii)Compressivestrength>=70 N/sqmm (7days)accordingtoASTM D 695;Tensile Strength>=30N/sqmm (after7 daysat +30°C cure)(AccordingtoASTMD638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv ) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle orcracksarerequiredtobemonitoredwhilegroutingandsuchpointstobesealedasandwhen required without any extra cost complete all as specified and as directed by Engineer-in-charge.Note :- Mode of measurement: per kg of material consumed |
| 123 | Material and Labour for preparation of new steelsurfacesof any description over 10cm width or girth and applying two coats of synthetic enamel paint over with and including one coat of red oxide zinc chrome primercomplete all as specified and as directed by Engineer-in-charge. |
| 124 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem , sheet switches, ceiling rose, pendent holder , sockets, fan regulator , bell push, Electronic bell , sunken box except concealed conduitetc.complete all as specified and directed by Engineer-in-charge. (i) The weight of aluminium scrap , copper scrap and Iron scrap shall be ascertained by BOO as ordered by GE and sameduly countersinged by GE shall be enclosed with final Bill. Bathinda.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.(ii)The rate of cutting chases (as required) and making good surfaces to match with adjoining surfaceshall be measured and paid seperately under serialitem nos. 129.00,130.00,131.00,132.00 & 133.00 of BoQ. |
| 125 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits)with two single core 2.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked )using approved colour coding as per IS (Red, Black and Green for single phase circuits) in existing concealed surface conduit and New GI sunken box (thickness not less than 1.2mm) covered with new 3 mm thick bakelite laminated hylem sheet (ISI marked) andfixed with brass screws & cup washersfor one light point / fan point / exhaust fan controlled by one switch , with andincluding one single core 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt ISI Markedcontinues as earth wire connected to earth dolly etc.with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge Notes for serial item nos. 124.00,125.00,126.00,127.00 & 128.00 : (i) switches one way 5 /6 Amp, socket out let 5Amp/6 Amp , two way switches5 /6 Amp and bell push switch shall be measured and paid seperately under respective items of Schedule\"A\" BoQ.(ii) All wires going into SP, SPN, TPN, MCCB shall have copper lugs of adequate size. |
| 126 | All as per item No 124.00 here- in -before but for one Socket outlet5 Pin, 5/6 Amp, flush type on same boardcomplete all as specified and as directed by Engineer-in- charge. |
| 127 | All as per item No124.00 here- in -before but for one Socket outlet 5 Pin, 5/6 Amp, flush typeon independent board complete all as specified and as directed by Engineer-in- charge. |
| 128 | All as item No 124.00 here -in- before but for one light point controlled by Two Two way switch complete all as specified and directed by Engineer-in-chrage. |
| 129 | All as per item No124.00 here -in- before but for one Socket outlet multipurpose 2 in 1, 6 Pin, 6/16 Amp, flush typecomplete all as specified and as directed by Engineer-in- charge. |
| 130 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), inPVC conduit complete withtwo single core 2.5 Sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through withand including PVC rigid conduit 20mm dia ( heavy duty )ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick )and flushfixed with cement mortar 1:4, 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for 15 Amp switches and socketpoint controlled by one switch 15 Amp, top cover fixed with brass screws & cup washerswith and including single core2.5 sqmm FRLSH PVC insulated multi strand copper conductor wire ISI Marked continues as earth wire connected to earth dolly etcwith and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Note for serial item no.129.00 ,130.00,131.00 & 132.00: (i) switches 5Amps & 15Amps ,socket outlets 5Amps & 16 Amps &fan regulator shall be measured and paid seperately under respective items of Schedule\"A\" BoQ.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clipsas directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account.(iv) All wires going into SP, SPN, TPN, MCCB shall have copper lugs of adequate size. |
| 131 | All as per item No 129.00 here- in -before but for one Socket outlet 3/5 Pin, 5/6 Amp,250 voltsflush type on same boardcomplete all as specified and as directed by Engineer-in- charge. |
| 132 | All as per item No129.00 here- in -before but for one Socket outlet 5 Pin, 5/6 Amp, 250 voltsflush typeon independent board complete all as specified and as directed by Engineer-in- charge. |
| 133 | All as per item No129.00 here -in- before but for one Socket outlet multipurpose 2 in 1, 6 Pin, 6/16 Amp, flush typecomplete all as specified and as directed by Engineer-in- charge. |
| 134 | Material and labour forFlame Proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with twosingle core2.5 Sqmm(nominal cross section area)FR-LSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for Phase, netural . drawn through , with and including Fame Proof Rigid Stove Enamelled Black ERW Conduit minimum 20mm dia with and includingall flame proof fittings and accessories i.e. flame proof joint,flame proof pipe bend, flame proof union,flame proofreducer,flame proof nipple, pipe hook, Screws, GI saddles, clamps, connectors etc,with andincluding one single core 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc.with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Note for serial item no. 133.00 : (i) flame proof rotary type switch shall be measured and paid seperately under appropriate item of schedule \"A\" BoQ.(i) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (ii) All wires going into SP, SPN, TPN, MCCB shall have copper lugs of adequate size |
| 135 | Supply and Fixingflame proof rotary type switch with termination box in LM6, 16A, Single pole 250 volts complete all as specified and as directed by Engineer-in- charge |
| 136 | Supply& Fixing Flame proof LED light fittings 2 x 8 wattCMRI certified recommended for gas vapor group of IIA & IIIB Zone 1 & 2 and IP-65 protection with die cast aluminium hosing with heat resistant toughened glasswith LED tube light fixtures , driver, holder, connector etc.complete with all accessories , as per manufacturer\"s instructions prewired and including connecting up with three core flexible copper cableof suitable size complete all as specified and as directed by Engineer-in-charge. |
| 137 | Supply& Fixing Flame proof LED light firtings 16 watt for security light CMRI certified recommended for gas vapor group of IIA & IIIB Zone 1 & 2 and IP-65 protection with die cast aluminium hosing with heat resistant toughened glasswith LED tube light fixtures , driver, holder, connector etc.complete with all accessories as per manufacturer\"s instructions prewired and including connecting up with three core flexible copper cableof suitable size complete all as specified and as directed by Engineer-in-charge. |
| 138 | Supply and Fixingswitch piano flush typesingle pole one way 5 /6 Amp complete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 139 | Supply and Fixing switch piano, flush type single pole two way 5 /6 Amp, 240 volts all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 140 | Supply and Fixing switch piano flush type single pole one way 15 /16 Amp complete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 141 | Supply & fixing Socket outlet multipurpose2 in 1, 3/5 Pin, 5/6 A, flush complete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 142 | Supply & fixing Socket outlet multipurpose2 in 1, 3/5 Pin, 15/16 A, flush complete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 143 | Supply and Fixing Ceiling rose, PVC/ polycarbonate, isolated body complete all as specified and as directed by Engineer-in- charge. Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 144 | Supply and Fixing lamp holder PVC/ polycarbonate type with back plate suitable for batten fitting with LED bulb 9 watt complete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.123.00 of BoQ here-in -before and nothing shall be extra paid on this account. |
| 145 | Material and Labourin replacementAir termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in- charge. |
| 146 | Material and Labourin replacement Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screwcomplete all as specified and directed by Engineer-in -charge |
| 147 | Material and Labourin replacementAluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above groundcomplete all as specified and as directed by Engineer-in- charge. |
| 148 | Supply and fixingin replacement sheet metal enclousers made out of CRCA mild steel sheet , not less than 1.2mm, IP-54 protection, flush mounted with metaldoor, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door,08 modules, dust and vermin proof suitable for incorporation of MCBs/ MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs/ MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of200 Ampscopper bus bar is included in this item and nothing shall be paid extra on this account. |
| 149 | Supply and Fixing RCCB for earth leakage, Over Load and short circuit protection suitable for 230 volt, AC supply , 63 Amps double pole rupturing capacity not less than 30mA complete all as specified and directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.147.00 here-in-befoe of BoQ here-in -before whereas applicablenothing shall be extra paid on this account. |
| 150 | Supply and FixingMCB SPN 63 Amps, 10 KA, ‘C’ Curve, 240 V AC,50 Hzcomplete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.147.00 here-in-befoe of BoQ here-in -before whereas applicablenothing shall be extra paid on this account. |
| 151 | Supply and FixingMCB SP 6 to 32 Amps 240, 10 KA ‘C’curvecomplete all as specified and as directed by Engineer-in- charge.Note: (i)Labour element for taking down old unservicable material is included in serial item no.147.00 here-in-befoe of BoQ here-in -before whereas applicablenothing shall be extra paid on this account. |
| 152 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor having cross sectional area 16 Sqmm2 coreconforming to IS-7098 (Part-I -1988) including taking out old unservicable cable with and including taking out old unservicable bricks/ PCC Coverscomplete allas specified and as directed by Engineer-in-Charge.Note:- 1.Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately. 2. The rate of taking out old unservicable cable andtaking out old unservicable bricks/ PCC Covers is included in this item and nothing shall be paid extra on this account. |
| 153 | Taking out old unservicable cable and brick protection and Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor having cross sectional area 50 Sqmm4 coreconforming to IS-7098 (Part-I -1988) complete allas specified and as directed by Engineer-in-Charge. Note:- 1.Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately. 2. The rate of taking out old unservicable cable andtaking out old unservicable bricks/ PCC Covers is included in this item and nothing shall be paid extra on this account. |
| 154 | Material andLabour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified.(Note:- Punned thickness shall be considered for payment purpose) |
| 155 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete allas specified and as directed by Engineer-in-Charge. |
| 156 | Supply and fixing GI tubing, light grade 20 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , under road and hardstandingetc. and making good after laying of cable complete all as specified and as directed by Engr - in- Charge. |
| 157 | Supply and fixing GI tubing, light grade 40 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , under road and hardstandingetc. and making good after laying of cable complete all as specified and as directed by Engr - in- Charge. |
| 158 | Supply and fixigin replacement of wall Mounted battern fittings Square profile 20 watt White flux appx 4.00 feetlong , pre wired complete fitting and all other accessories fitting arrangements as per manufacturer\"s instructions including and connection withflexible twin core copper cable of size 23/.00076from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge. |
| 159 | Supply and Fixing in replacementLED mirror light fitting 10 watt , 6000K linear and compact with decorative grey end caps , polycarbonate body and ribbed opal diffuser complete fitting with Lamp & all other accessories fitting arrangments complete all as per manufacturer\"s instructionons and connection withflexible twin core copper cable of size 23/.00076from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge. |
| 160 | Supply and laying in replacement Sleek pressure die cast aluminium houshing, heat resistant glass, Energy saving, IP-65 protection, better optics for uniformdistribution street / Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other Accessories etc. suitable for 42mm / 32mm OD Entry for direct mounting on pipe bracket fixing on poles / along wall with and including bracket made out of GI Tube light Grade 40mm dia, 2.00 mrtre long bend to shape of 120 degree angle at half metre from botom (as per sample) fixing with MS Clamp (02 Nos) and nut bolts with andincludingapplying two coat of aluminium paint over a coat of red oxide primeron bracket and clamps, with andincluding making electric connectionwith using twin core copper cable of suitable sizefrom connection point to fitting complete all as specified and as directed by Engineer-in- charge. |
| 161 | Material and labourin replacementSub main wiring complete with two single core 6 sqmm,1100 volts grade, ISI Marked , PVC insulated, multi strandedcopper conductor cable FRLSHwithand includingsingle core 6 sqmm,1100 volts grade,ISI Marked,PVC insulated, multi strandedcopper conductor cable FRLSHfor earth wire in existing PVC concealed conduit(Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and directed by Engineer-in-charge. Notes:-(a)Threesingle core6SqmmFRLSH PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradeshall be measured as one length.(b) All wires going into SP, SPN, TPN, MCCB shall have copper lugs of adequate size. |
| 162 | Material and Labour in replacementSub main wiring with two single core of size 6 SqmmFRLSH PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts grade,ISI Markedincluding cuttting, chasing and grouting including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-IISI marked including all fitting such as Tee, Elbow, bend etc drawn in andincludingone single core of size 6 SqmmFRLSH PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts grade ,ISI Marked asin contineous earth conductor cable connected to earth dollycomplete all as specified and as directed by Engineer-in- charge.(Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge..Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b)Threesingle core6SqmmFRLSH PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts grade including non metallic rigid PVC conduit of size 25 mm dia shall be measured as one length.(c) All wires going into SP, SPN, TPN, MCCB shall have copper lugs of adequate size |
| 163 | Supply and Fixingin repair Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB VTPN 4 way, 415 V AC with 200 Amps rated copper bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCBs/ MCCBs/ Isolators and earth & neutral bus bar etc conforming to IS/IEC-61439-2:2011, BS-5484complete all as specified and as directed by Engineer-in- charge.Notes: (i)MCBs/ MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of200 Ampscopper bus bar is included in this item and nothing shall be paid extra on this account. |
| 164 | Supply and Fixing MCCB 4 pole of rating 100 Amp, Icu -100% 16 KA, thermal magnetic basedcomplete all as specified and as directed by Engineer-in- charge. Note: (i)Labour element for taking down old unservicable material is included in serial item no.162.00 here-in-befoe of BoQ here-in -before whereas applicablenothing shall be extra paid on this account. |
| 165 | Material and Labour in replacement sheet metal enclosure with socket and plug top and MCB single pole enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 230 Volt complete all as specified and as directed by Engineer-in- charge. |
| 166 | Supply , Fixing and testingin replacement ofwater heater (Geyser)Auto restart and safety measures type electrical operated 230/240 Volts25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & with andincluding electric/ earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installation complete all as per manufacturer\"s instructions complete all as specified & directed by Engineer-in- Charge.Note: Old unservicable Geyser shall be deposited in the store yard of AGE (E/M) GE (North) Bathinda . The rates of this aspect are included in this item and nothing shall be paid extra on this account. |
| 167 | Supply& Fixing and testingin replacementExhaust fan (Heavy duty) steel body, AC, Single phase 230 volts,50HZ,900 RPM,300 mm sweep BEE, 5 star rated a with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc. mounted in suitable opening arrangmement in wall and electric connection with and including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC Conduit and hanging on wall with 04 Nos. steel fastners 10mm dia 100mm longwith and including serial number of fan as issued by Engineer-in-charge and GE office namewith red colour permaent marker complete all as specified and directed by Engineer-in- charge.Note: Old unservicable Exhaust fan shall be deposited in the store yard of AGE (E/M) GE (North) Bathinda . The rates of this aspect are included in this item and nothing shall be paid extra on this account. |
| 168 | Supply& Fixingin replacementCeiling fan of 1200mm sweep complete with blades, down rods, including remote for control with cell and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable sizefrom ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement, with and including serial number of fan as issued by Engineer-in-charge and GE office namewith red colour permaent marker complete complete all as specified and as directed by Engineer-in-charge.Note: Old unservicable ceiling fan shall be deposited in the store yard of AGE (E/M) GE (North) Bathinda . The rates of this aspect are included in this item and nothing shall be paid extra on this account. |
| 169 | Material and Labour in replacement for Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6.00mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to and including galvanized iron strip 25mm x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part -I and earth lead protected by galvanized pipe light grade40 mm bore (ISI marked) up to7.5 mtrs from earth electrode , including, earthing plate shall be surrounded by alternative layers 15cm thick of charcoaland common all around bottom and top , necessary earth work and excavation in soft/loose soil , form work, GI medium grade 20mm bore watering pipe (ISI Marked) with funnel and wire mesh,40mm thick chamber made withPCC 1:2:4 type B1,cover slab made with RCC 1:2:4 type B1 Design mix,edgescovered with and including 40mm x 40mm x 6 mm angle iron frameduly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer with and including 8mm dia TMT bars at 75mm c/c both ways with MS Hook of 12mm dia MS bars,etc , all as specified and directed by Engineer-In-charge. Note : (i)Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed.(ii) The rate of earth work in soft/loose soili.e. excavation, returing filling and removal, form workis included in this item and nothing shall be paidextra on this account.Note:- (i) Earth continuity ofgalvanized iron strip 25mm x 4 mmincluding protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed.(ii) The rate of earth work in soft/loose soili.e. excavation, returing filling and removal, form workis included in this item and nothing shall be paidextra on this account.(iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 170 | Material and Labourin replacementfor earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion.Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed.(ii) The rate of earth work in soft/loose soili.e. excavation, returing filling and removal, form workis included in this item and nothing shall be paidextra on this account.(iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 171 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule \"A\"/BOQ |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail