| 1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.19.3.1 Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 15mm nominal outer dia pipes. |
| 2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.19.3.1 Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20 mm nominal outer dia pipes. |
| 3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.19.3.1 Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25 mm nominal outer dia pipes. |
| 4 | Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc.16 (16mm Outer Dia) pipe |
| 5 | 20mm nominal outer dia pipes. |
| 6 | External work including trenching, refilling etcExternal work including trenching, refilling etc 20mm nominal outer dia pipes. |
| 7 | External work including trenching, refilling etcExternal work including trenching, refilling etc 25 mm nominal outer dia pipes. |
| 8 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre 110 mmProviding and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre 110 mm |
| 9 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Coupler 110 mm |
| 10 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Single tee with door 110x110x110 mm |
| 11 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Bend 87.5° 110 mm |
| 12 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalent.110mm dia Door Tee 110 mm dia Plain Bend |
| 13 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalent 110 mm dia Plain Bend |
| 14 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalen 110 mm dia Collar. |
| 15 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalen 110mm dia P-Trap |
| 16 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalen 110mm Door Bend |
| 17 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalen 110mm dia Plain Tee |
| 18 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalen 110mm PVC Prince Cliff. |
| 19 | 110mm x 80mm dia Reducer |
| 20 | 110mm 45 deg Bend |
| 21 | 80mm 45 deg Bend |
| 22 | 80mm dia Door Bend |
| 23 | 80mm dia Door Tee |
| 24 | 80mm dia Plain Bend |
| 25 | 80mm dia Collar. |
| 26 | 80mm dia Floor Trap. |
| 27 | 80mm dia Plain Tee |
| 28 | 80mm PVC Prince Cliff |
| 29 | 80mm dia PVC Cowel Caps |
| 30 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 31 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-CP Brass single hole basin mixer |
| 32 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 33 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms |
| 34 | Providing and fixing toilet paper holder C.P. brass |
| 35 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 36 | providing and fixing wall mounted shower 200mm dia eith shower arm 450mm long round shape with 90 degree bend with all fittings |
| 37 | providing handling storing and shifting testing commissioning of hot water heater fixed to walls with anchor bolts of 25lts capacity for pantry and toilets |
| 38 | p/f brass towel ring round with round flenge of approved quality |
| 39 | Providing and fixing CP Neeple |
| 40 | Providing and fixing C.P Cup |
| 41 | Providing and fixing CP Grating |
| 42 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backinRectangular shape 453x357 mm |
| 43 | Providing and fixing of CP Health Faucet 900 mm long complete of standard make.(jaguar,Hindware ,perryware or equivalent ) |
| 44 | Providing and fixing soil, waste and vent pipes : 100 mm dia, Sand cast iron S and S pipe as per IS:1729 |
| 45 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 46 | Providing and fixing PTMT Waste Pipe for wash basin and sink, of approved quality and colour: Flexible pipe 32 mm dia |
| 47 | Providing and fixing Ball Valve 25 mm |
| 48 | Providing and fixing Ball Valve 20 mm |
| 49 | Providing and fixing TANK NIPPLE |
| 50 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work-Exposed on wall (B Class)25mm dia pipe( external works) |
| 51 | Union 25 mm |
| 52 | Providing and installation of electric water motor of Crumtum make having 01 H.P including all fitting complete. |
| 53 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 100 x 100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 54 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 55 | providing and fixing stainless steel AISI 304 kitchen sink with CI brackets and stainless steel plug 40mm all complete job |
| 56 | providing and fixing of CP brass sink mixer eith regular swinging spout all complete job |
| 57 | Providing and laying FULL TYPE vitrified floor tiles 600x600 mm (in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 58 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 59 | Providing and laying 16mm thick Granite of any colour and shape (area of slab over 0.5 Sqm) gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 60 | Extra for providing edge moulding to 16 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. |
| 61 | Extra for providing opening of required size and shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble / stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 62 | Providing and laying Ceramic glazed floor tiles (NON-SKIDD)300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 13753 of minimum thickness 5mm of approved make like NITCO, SOMANY, KAJARIA or equivalent make in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer in charge over 12mm thick bed of cement mortar 1:3 (1cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 64 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 65 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 66 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 67 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 68 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 69 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Bell push |
| 70 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 71 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 72 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 73 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modularswitch,connection,painting etc. as required. |
| 74 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 75 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 76 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 77 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 78 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 79 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts \"C\" series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 80 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts \"C\" series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 81 | Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required. |
| 82 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 83 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 84 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 85 | Supply installation testing and commissioning of IP:20 Aluminium Batten 20W-22 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 86 | Supply installation testing and commissioning of IP20 led downlighter 15 W-18 W +/- 1 W LED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 87 | Supply installation testing and commissioning of IP:20 Aluminium Batten 8-10 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 88 | Supply installation testing and commissioning of Chrome Finished Bracket Light with Standard Height of 300 mm and Opal Glass. |
| 89 | Supply installation testing and commissioning of BLDC Ceiling Fan 1200 mm 230V 28 W with Speed RPM 350 with miimum Air delivery 220 CMM including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 90 | Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of ABS Plastic Material with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required .300 MM |
| 91 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Meter Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD |
| 92 | INCOMER MCCB 125 A F.P 25 Ka with Adj.T.M.R With Icu=Ics=100% |
| 93 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(150 Amps ) and MCB Strip of suitable size as Required. |
| 94 | OUTGOINGS MCB 32 A D.P 10 Ka with \"C\" Curve |
| 95 | 1P LCD Meter 5-30A |
| 96 | D.P M.C.B 10 A 10 Ka with \"C\" Curve |
| 97 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 70 Sq.mm A2XFY |
| 98 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)3½ X 70 sq. mm (38mm) |
| 99 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 100 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 101 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 102 | Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.20 mm PVC Conduit |
| 103 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE in+B113:B116sulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. Please Enable Macros to View BoQ information |