| 1 | [SH:-Dismantling of old structure] |
| 2 | Dismantling wood work of sectional area 40 Sq.cm. and above wrought, framed and fixed in frames, other frames and trusses including stacking the material within 50 m lead. |
| 3 | Dismantling cement, asbestos, celotax or other ceiling or partition hard board partition wall including stacking of serviceable materials and disposal of serviceable materials within 50 m lead. |
| 4 | Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead. |
| 5 | [SH:Roofing of Gonpa & Monk Residence] |
| 6 | Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.b) In Tees, Angles and Channels |
| 7 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall Sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages = 202.061 Sqm After H & L laping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 8 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05) - (3 x 0.15) = 11.75m |
| 9 | [SH:- Extension of Choemey Khang ] |
| 10 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m |
| 11 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: (a)Foundations and plinth |
| 12 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 13 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a)M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) M-20(1 cement :1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a)M-20 (1 cement :1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick |
| 17 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Reinforcement of RCC work including bending, binding and placing in position complete.a)Mild steel and medium tensile steel bars. |
| 19 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 20 | c) Suspended floors, roofs, landings shelves and their supports, balconies andchajjas (3.5 m height). |
| 21 | e) Column, pillars, posts and struts etc. |
| 22 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 23 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 24 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 25 | Provoding approved best available local wood (Class - B-II) work in frames of doors, windows clestory windows and other frames, wrought framed and fixed in position. |
| 26 | Providing and fixing MS grills of required pattern in wooden frames ofwindows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 27 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38mm thick best available local wood class - B I |
| 28 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 29 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall Sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages = 202.061 Sqm After H & L laping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 30 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05) - (3 x 0.15) = 11.75m |
| 31 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeb) Size of Tile 600x600 mm |
| 32 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 33 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc completeb) 250 x 10 mm. |
| 34 | c) 100x 10 mm |
| 35 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 36 | b) 100 mm |
| 37 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 38 | Neat cement punning. |
| 39 | Distempering(Two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 40 | Applying priming coat with ready mix pink primer of approved brand and manufacture on wood work complete. |
| 41 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 42 | [SH:-Providing & fixing Chequered Tiles] |
| 43 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:a) Light shades using white cement |
| 44 | [SH:-Buddhist Architectural Works] |
| 45 | Cleaning, Scarifying old paint works to even surface and re-Painting of main Buddha Statue and other statues as per Buddhist architectural norms and as per direction of the Engineer-in-charge Complete. |
| 46 | Re-doing of Buddhist architectural features cleaning etc. viz. Gyelling etc. and re-painting the same in two or more coats as per Buddhist architectural norms & as per direction of the engineering- in- charge on column and beams etc complete. |
| 47 | Re-doing of Buddhist architectural workscleaning etc. viz.Pema-Tsortso, Bebur in stages on doors & windows including re painting in levelsas per Buddhist architectural norms and as per direction of the engineer- in- charge complete. |
| 48 | [SH: Buddhist Traditional main Gate] |
| 49 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 50 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: (a)Foundations and plinth |
| 51 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT Steel |
| 52 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
| 53 | e) Column, pillars, posts and struts etc. |
| 54 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 55 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 56 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 57 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b)M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 58 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a)M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 59 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 60 | 12 mm cement plaster 1 : 4 (1 cement : 3 fine sand). |
| 61 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 62 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 63 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. (b) Ornamental Grill |
| 64 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 65 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 66 | Buddhist architectural Painting works |
| 67 | Providing & Fixing Buddhist Eight Lucy Design. |
| 68 | [SH: Electrification works ] |
| 69 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.a)(Long Point) \"Group \"A\" |
| 70 | b ) (Medium Point ) Group \"B\" |
| 71 | c ) (Short Point ) \"Group \"C\" |
| 72 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 73 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 74 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 75 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requireda) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 76 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 77 | c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 78 | d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 79 | e) 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 80 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 1 x 1.5 sq. mm |
| 81 | b) 2 x 1.5 sq. mm |
| 82 | c) 4 x 1.5 sq. mm |
| 83 | d) 6 x 1.5 sq. mm |
| 84 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 20mm. |
| 85 | b) 25mm. |
| 86 | c) 32mm. |
| 87 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.a) 75 mm X 75 mm X 60 mm deep. |
| 88 | b) 100 mm X 100 mm X 60 mm deep. |
| 89 | c) 200 mm X 150 mm X 60 mm deep |
| 90 | d ) 200 mm X 250 mm X 60 mm deep |
| 91 | e) 250 mm X 300 mm X 60 mm deep |
| 92 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.a) 5/6 amps switch. |
| 93 | b) 2 way 5/6 amps switch. |
| 94 | c) 15/16 amp switch. |
| 95 | d) 3 pin 5/6 amp socket outlet. |
| 96 | e) 6 pin 15/16 amp socket outlet. |
| 97 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 98 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 99 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 100 | Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 101 | Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible, FR PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. |
| 102 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 103 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 104 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 105 | Installation of exhaust fan in the existing opening, i/c making good the damage, connection, testing, commissioning etc. as required.A) Upto 450 mm sweep. |
| 106 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.a) 32 Amp TP&N. |
| 107 | b) 63 Amp TPN. |
| 108 | c) 160 Amps TPN |
| 109 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.A) 100 Amp, 16 KA. |
| 110 | B) 125 Amp, 16 KA. |
| 111 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 2 + 6 way, Double door |
| 112 | b) 2 + 8 way, Double door |
| 113 | c) 2 + 10 way, Double door |
| 114 | d) 2 + 14 way, Double door |
| 115 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a) 4 way (4 + 12), Single door |
| 116 | b) 8 way (4 + 24), Single door |
| 117 | c) 12 way (4 + 36), Double door |
| 118 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 119 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.A) 63 amps |
| 120 | B) 100 amps |
| 121 | Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 122 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 123 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as requireda) 32 Amp TPN. |
| 124 | b) 63 Amp TPN. |
| 125 | c) 200 Amps TPN |
| 126 | Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required.a) 32 amps TPN, 4 way |
| 127 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.a) Above 95 sq. mm and upto 185 sq. mm |
| 128 | Providing and fixing of Ceilling fan 1400sweep of approved quality with required accessory as per specification and direction of Engineer-in-charges . |