Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M & L fornon-skid ceremic colouredtiles7 to 8 mm thick(Square/rectangular) areaof each tile exceeding0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match of tiles including dismantling of tiles and screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishesall as specified. |
| 2 | All as per serial item No 1 as above but as in vertical surfaces of tiles and rendering 10 mm thick in cement mortar 1:4, as in backing layer complete all as specified. |
| 3 | M & L for 20-25 mm thick machine cut pre polished kota stone slab flooring and jointed with grey cement slurry fixed with pigmentto match to shade of the slab including rubbing and mirror polishing over and or 20 mm thick bedding layer of cement mortar 1:6 for laying floor finishes even and rough with and including dismantling floor, hearth or wall kota stone slab including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 4 | All as per serial item No 03 as above but as in vertical surfaces including dismantling of tiles and rendering 10 mm thickin cement mortar 1:4, as in backing layer complete all as specified. |
| 5 | M & L for non- skid ceremic colouredtiles7 to 8 mm thick(Square / rectangular) areaof each tile exceeding0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match incl dismantling of tilesand screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishesall as specified. |
| 6 | M&L for Glazed (plain /coloured) ceramic tiles wall 600x450x7mm thick on vertical faces of walls including 10mm thick rendeingin CM 1:4 set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting complete all as specified. |
| 7 | Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all asspecifiedand directed. |
| 8 | Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all asspecifiedand directed. |
| 9 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 10 | Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge. |
| 11 | S&F for 125x60mmx2mm thick pressed steel, frames for door with one or more rebates including filingand inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface all as specifiedand directed. |
| 12 | S&F for 105x60mmx2mm thick pressed steel, frames for door with one or more rebates including filing andinner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS flat at bottom of the frame etc, including wooden texture finished paint on the frame surfacecomplete all as spd and directed. |
| 13 | S&F for 30 mm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed. |
| 14 | M & L for 35mm thick plain framed glazed and skeleton shutter open rebated& prepared to receive glass, gauge etc, with sash bar edges of framingplain chamfered or rounded fitted with cut and mitered beads for securing glass including campsule mesh tightly fixed with the glazed and skelton door shutter etc, of 2nd class hard wood, members of shutters as specified in SSR Part - ISection 8 clause 8.24 (a) fitted to chowkats all as specified and directed. Note:- Campsule Mess will be measured and paid separately. |
| 15 | S&F for 100mm long stainless steel butt hinges complete all as specified and directed. |
| 16 | S&F for 200mm long aluminum anodised, barrel tower bolts of extruded section and fixed. |
| 17 | S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised |
| 18 | S&F 150 mm long floor door stopper of aluminium alloy body and tongue, brass body and tongue with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 19 | S&F for 300 mm longaluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 20 | S&F 300 mm size, MS ordinary rat tail rod pattern springs including roller and roller plate complete including fixed to wooden and steel chowkats. |
| 21 | M&L Preparation of oldwooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint. |
| 22 | M&L painting to wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface all as spd and directed |
| 23 | M & L preparation of old steel surfaces of any description over 10 cm inwidth or girth and applying one coat of synthetic enamel paint |
| 24 | M&L forpainting to steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface all as spd and directed |
| 25 | M & L for Plain Cement Concrete 1:3:6type C-1(using 20 mm graded aggregate) as in bed blocks for hold fast/concrete filling in chowkhats and similar work etc complete all as specified and directed. |
| 26 | M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using liquid WPC@ 200ml per 50 kg of cement including taking down plaster finishing the surface even and fair without using extra cement and necessary scaffolding all as spd and directed,Note :- WPC shall be paid seperately. |
| 27 | M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4)using liquid WPC@ 200ml per 50 kg of cement newly surface even and fair without using extra cement and necessary scaffolding all as spd and directedNote :- WPC shall be measured and paid seperately. |
| 28 | Supply only liquid water proofing compound |
| 29 | M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) including taking down plaster finishing the surface even and fair without using extra cement and necessary scaffolding all as spd and directed |
| 30 | M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6)newly surface even and fair without using extra cement and necessary scaffolding all as spd and directed |
| 31 | M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment and applying two coats of oil bound distemper using Airless spray technology operating single spray gun paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. |
| 32 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology of operating single spray gun and paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. |
| 33 | M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment and applying two coats of exterior weather proof paint using Airless spray technology operating single spray gun paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturerand accessories for applying weather prrof paint should be able to spray in hard to reach areas and penetration of paint on the surface to achieve excellent application using limited manpower complete all as specified and directed. |
| 34 | M&L for preparation of new plastered surfaces of walls and applying two coats of exterior weather proof paintusing airless spray technology of operating single spray gun and paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and accessories for applying weather proof paint should be able to spray in hard to reach areas and penetration of paint on the surface to achieve excellent application using limited manpower complete all as specified and directed. |
| 35 | M&L brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) incl demolition of brick masnory built in cement mortar complete all as specified and directed |
| 36 | M&L brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) incl demolition of brick masonry built in cement mortar complte all as specified and directed |
| 37 | M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofsunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 20 cm girth in RCC chajjas in brick walls complete all as specified and as directed. |
| 38 | Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs, cupboards and stair case similar work carefully and matching to adjoining disturbed surfaces all as directed. |
| 39 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for. |
| 40 | M & L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide. |
| 41 | Form work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. |
| 42 | M & L formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified. |
| 43 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. |
| 44 | S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia. |
| 45 | M&L RCC 1:1.5:3 type B1 using 20 mm graded aggregate as in slab, shelves and stair case etc.all as specified and directed. |
| 46 | M&L RCC type B 1, 1:1.5:3 (20mm graded agg) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed.. |
| 47 | Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for thesurfaces completeall as spd as directed. |
| 48 | Demolition of cement concrete (un-reinforced), in any position and paving n.exc. 15 cm thickness (below or above ground level) including tile/ terrazzo floor complete all as specified and directed. |
| 49 | M & L for plain cement concrete 1:3:6typeC-1(using 20mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thicknessall as specified or as directed. |
| 50 | M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floors, sub base, apron etc incl roughening the existing surface complete all as specified. |
| 51 | M&L for18-20 mm thick Granite (black colour only) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. stone including grinding and polishing and 15mm screed bed in cement mortar 1:6 including dismantling of tiles, hearting etc complete all as specified. |
| 52 | Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed |
| 53 | S&F in repairs stainles steel Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod all as directed and specified. |
| 54 | S&F powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality) for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and including 5.50 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below-(i) Window frame of minimum size : 92 x38 mm X 1.15 mm thick for three tracks.63 x38 mm X 1.15 mm thick for two tracks.Note :- rate for glass & wiremesh shall not be paid paid separately for this item. |
| 55 | S&F for mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed. |
| 56 | M&L for E-board false ceiling consisting of powder coated GI wall angle, main T and cross Tof 25mmX 25 mm X 1.40 mm thick grid frame work, joist, angle/ Tee as directed and mild steel wire hook not less than 6 mm dia with arrangement for adjusting height of ceiling and including provn of 4 mm thick E-Classic board in pannelof size 600X600mm with necessary off cut including dismantling of existing false ceiling and taking down and refixing of Electric fitting carefully complete all as specified and directed. |
| 57 | Dismatling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 58 | M&L for pre- painted galvalume aluminum zinc coating GI based profile sheet steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 59 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 60 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any complete all as specified and directed. |
| 61 | Dismantling unframed timber scantlingsin fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position complete all as specified and directed, |
| 62 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade Fe-410 gde st- 240 complete all as specified and directed. |
| 63 | S&F for computerised reflective letter / bldg number on ACP sheet (size 45mm x 45mm) and fixing with 04 nos of screw, rawal plug etc on wall in front of building complete all as specified and directed. |
| 64 | M&L for Machine pressed precast conctete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Gradeover 25mm thick sand cushioning including watering and consolidation incl laying of PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) and dismatling of existing tile/ demolition of PCC if reuqied complete all specified and directed. |
| 65 | M&Lfor PCC kerb stone outer coloured surface machine pressed factory made of size 300 mm long , 300mm wide, 150mm thickusing M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete incl form work weathering, slightly rounded or chamfered angles and throating complete all as specifed and directed |
| 66 | S&F in repair vitreous china squatting pan of orrissa pattern long pan size580 x 440 mm white with \"P\"or \"S\" trap size100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of lime concrete bedding (1:2:5), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed. |
| 67 | S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed. |
| 68 | S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed. |
| 69 | S&F in repair 15 mm dia bib tap fancy type chromium plated with flange quarter turn incl all necessary fittings complete all as specified and directed. |
| 70 | S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts complete all as specified and directed. |
| 71 | S&F for 20 mm bore CPVC water tubing with all fittings \"medium grade\" and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any descriptionand cutting chases for concealed water tubing and making good, cutting exceeding 20 cm girthwhere requiired completecomplete all as specified or as directed. |
| 72 | S&F for 32 mm bore CPVC water tubing with all fittings \"medium grade\" and fixed complete to wall and ceiling or laid in floorsincl taking down of existing pipe line of any description and cutting chases for concealed water tubing and making good, cutting exceeding 35 cm girthwhere requiired completecomplete all as specified or as directed. |
| 73 | S&F in repairs 75 mm x 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of approvedquality complete all as specified and directed. |
| 74 | S&F in repairs 100mmx100mm stainless steel grating fixed complete all as specified and directed. |
| 75 | S&F in repair fancy type stainless steel towel rail size 600mm long including a pair of brass bracket complete all as specified and directed. |
| 76 | S&F in repairs vitreous chinaware coloured oval shape counter wash hand basin of size 55X40X82cm complete including CP Waste coupling ,waste pipe ,complete fixing arrangementand cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge. |
| 77 | S & F in repair fancy type 125 mm size square brass CP shower rose with or without swivel joints complete all as specified and as directed. |
| 78 | S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed. |
| 79 | S&F in repairs designed looking mirror area exc 0.54 sqm to 0.75 sqm of selected quality 6mm thick glass, mounted on fixed to wall with CPplugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 80 | S&F in repairs of PVC corner set of three of size (12\"X12\" ,9\"X9\" and6\" X6\" ) with railling and complete all as specified and directed. |
| 81 | S&F in repair fancy type 15 mm bore brass chromium plated pillar tap screwed down for iron pipe and fixed to WHB including taking out existing mixer/tap from old WHB complete all as specified and directed. |
| 82 | S/F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls. |
| 83 | S&F powder coated aluminium frame for windows, ventilators and kitchen cupboards frame size and section as directed by engineer in charge with one or more rebates including jointing cleat for fixing glass / wiremesh etc and add on for powder coating (minimum thickness of powder coating 50 micron) complete all as directed and specified. |
| 84 | S & F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position incl dismalting of existing tank of capacity and any description all as specified in SSR Part I |
| 85 | S&F 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all asspecified or as directed. |
| 86 | S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 87 | Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. |
| 88 | S & F PVC (SWR) 110 mm diasoil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall all as specified or as directed. |
| 89 | S & FPVC (SWR) 110 mmbore bends all as specified or as directed. |
| 90 | S&F in repairPVC (SWR) multi floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain including jointing to waste pipe fixed in cement concrete (1:2:4), type B-1 complete all as specified and as directed. |
| 91 | S & F spun iron soil, waste and vent pipe, 75mm bore, in any length with or without ear with cement joint fixed to walls complete all as specified |
| 92 | S&F 100mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door |
| 93 | S&F 75 mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and directed. |
| 94 | S&F100 mm bore PVC cowl complete all as specified and directed. |
| 95 | S&Fsheet glass 3mm thick ordinary quality and glazing with oil putty not excceding 0.5 sqm in each pane complete all as specified and directed. |
| 96 | Internal & External E/M |
| 97 | Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified. |
| 98 | Taking down carefully UNSV main switch DBs of any description of an size in any position complete all as specified. |
| 99 | Taking down submain wiring including all accessories complete all as specified and directed. |
| 100 | Material and labour for point wiring with single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered withmodular plateand cover of suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:-(a) One light / fan/ exhaust fan point controlled by one switch. |
| 101 | All as Per Srl Item No 100 above but for (b) One 5 pin 5 Amp switch socket out let point on an independent board. |
| 102 | All as Per Srl Item No 100 above but for(c) One 5 pin 5 Amp socket out let point controlled by one switch on same board. |
| 103 | All as Per Srl Item No 100 above but forone 15 Amp 6 Pin switch socket out let independent with2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistrandedincl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified. |
| 104 | S & F Modular switch one way 10 A, 1 Module complete all as specified and directed by the Engr-in-Charge. |
| 105 | S & F Modular switch one way 16 A, 1 Module complete all as specified and directed by the Engr-in-Charge. |
| 106 | S & FModular Socket 6 Amp, 2/3 Pin combined 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 107 | S & FModular Socket 6/16 Amp, 2/3 Pin combined 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 108 | S & FModular fan regulator Step up type, 120 Watt, 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 109 | Supply and Fixing ceiling rose PVC/ Poly carbonate,Isolated body, threeterminal AC 230 volts complete all as specified and directed. |
| 110 | M & L for replacement oflamp holder, PVC / Poly carbonate, insulated bodymodular type with back plate batten/angle type for batten fittings complete all as specified and & directed |
| 111 | S&F in replacement LED mirror light fitting of 1 x 20 wattLED batten with aluminium housing with all accessories prewired suitable for wall /surface mounting complete with connection all as specified and directed. |
| 112 | Supply and Fix LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed. |
| 113 | Supply & Fixing in repairs security light fitting, LED type, 25 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source withintegrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with andincluding nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. |
| 114 | M&L for sub main wiring with two single core 6.0 Sqmm (FRLS)copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :-Two runs of 6.0 sqmm (FRLS) and one run of 6.0 sqmm (FRLS) copper conductor shall be measured as one unit length.) |
| 115 | Taking down carefully ceiling fan from existing site and deposit in MES Yard |
| 116 | Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 117 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 118 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etccomplete all as specified and directed by the Engr-in-Charge. |
| 119 | S&F in repairs MCB SPN 40 Amp 240 volt complete all as specified and directed by the Engr-in-Charge. |
| 120 | S&F in repairs MCB single pole 6 to 32 Amp 240 Volt \"B\" curve 10 KA complete all as specified and directed by the Engr-in-Charge. |
| 121 | S&F in repairs MCCB Triple pole and neutral 100 Amps 415 Volt curve 10 KA complete all as specified and directed by the Engr-in-Charge. |
| 122 | Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral linkscompleteall as specified and directed. |
| 123 | Supply and fix TPN DB -VTPN DB 4 way with provn ofMCCB 160 Amps , 415 Volt, 3 Phase, 4 wire AC 50 Hz having aluminium Bas Barphase and the neutral insulated with PVC sleeves, connected with appropriate size copper thimbles completeall as specified and directed. |
| 124 | Material & Labour for earthing complete including taking out old unsv and replacewith galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased inand including 15 mm dia GI \"light grade\" pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe \"light grade\" as water pipe from earth chamber andincluding excavation and earth work, PCC 1:3:6 typeC1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced complete all as specified and directed. |
| 125 | Taking down carefully serviceconnections of any description from pole, wallor service brackets etc including making good disturbed surface to match with the existing surface complete all as specified. |
| 126 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 3.5 core. |
| 127 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in Soft/loose soil for laying of LT UG cables/base for Poleetc complete all as specified and directed. |
| 128 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin soft/loose soil complete all as specified and directed. |
| 129 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 130 | M&L for sand cushioning laid in trenches for laying of LT UG cables complete all as specified and directed. |
| 131 | M&L Modular bricks common burnt clay building bricks, sub-class ‘B’ designation-75 for LT UG cable protectioncomplete all as spd and directed. |
| 132 | S&F GI tubes light grade of dia 80 mm with all fitting and fixed complete for protection of LT UG Cables laidto walls or in floors or along with poles etc complete all as specified and directed. |
| 133 | Notes:-Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail