Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed. |
| 3 | S&F factory madesolid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 4 | S&F factory madesolid PVC moulded door shutter 28 to 30 mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specifications and drawing of page no 146 of SSR Part -II complete all as specified and directed. |
| 5 | Material & labour Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary s&f lugs, Butthinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either sidecomplete all as specified and directed. |
| 6 | Description all as per ser item No-05 above butsize of frame 105x60mm complete all as specified and directed. |
| 7 | M & L PCC 1:2:4type B0 12 .5 mm graded aggregatecement concrete as filling to pressed steel frames complete all as specified and directed. |
| 8 | S&F factory made Box Type mild steel windows side hung glazed shutters with chowkets with glazing bars to receive glass and other side of the window wire mesh shutters to receive wiremesh orwire guage dovetailed or welded and steel peg stay with and including necessary welding, reveting, tower bolt, hanlde, holdfast,wire mesh ,plain and pin headed glazing fixed with puttu & hinges as per Drg No.CESZ/TD-1018/2011 Sheet No 1/3 complete all as specified and directed by Engr-in-Charge. (Note : mensurement of Guard barsshall be paid separately). |
| 9 | M&L PCC 1:2:4 type B0 12.5mm graded aggregatte as in hold fasts and bed blocks etc including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F Bands, straps, supports or staysfor rainwater, ventilating pipes,including bolts,if required hooks (stay),heavy,for largegates; hook and pintle hingeslarge hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks forhanging fans; plain angle cleatsfor securingpurlinstowoodtrusses or rafters; knee piece inserts; two way and three waystraps, plate washers and similarsmall articles conforming toFe-290 Gde-E-165 |
| 11 | Dismantling wrought iron or mild steel work (used in framework for stageing of water tank) of any description not otherwise provided for all as specified. |
| 12 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 13 | S&F mild steel Fe 410-W Qty as in joist, channel, angle or tee sections fixed independently without connecting plates etc all as specified and directed by Engineer-in-Charge. |
| 14 | S&F 1.00 mm thick plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) for top of Water tank staging or any were reqd all as specified and directed by Engineer-in-Charge. |
| 15 | M&L PCC (1:2:4) B-2 (40 mm graded) in foundation, filling and mass concrete for fixing of angle iron work inccluding necessary form work and allied work complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F 35 mm thick, factory made 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20(a), fitted to chowkats complete all as directed. |
| 17 | S&F 35mm factory made shutters plain framed, panelled shutterwith lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-Charge. |
| 18 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed. |
| 19 | S&F sheet glass 4.00 mm thick ordinary quality and glazing with oil putty in square, rectangle n.exc 0.5 Sqm in each pan all as specified and as directed by Engr-in-Charge. |
| 20 | S&F figured glass 4.00 mm thick, pin head type and glazing with oil putty in squares, rectangle exc 0.5 Sqm in each pane complete all as specified and as directed and directed by Engr-in-Charge. |
| 21 | S&F Floor door stopper of aluminum alloy body and tongue anodized with hard drawn steel spring fixed in floor of length 150mm complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed. |
| 23 | S&F Stainless Steel butt hinges medium weight of size 100 mm fixed with stainless screws complete all as specified and directed Engr-in-Charge. |
| 24 | S&F 125 mm butt hinges medium weight cold rolled mild steel and fixed with screws or weld to steel framecomplete all as specified and directed. |
| 25 | S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed. |
| 27 | S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed . |
| 28 | S&F in repairs 18/19 mm thickblock boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in shelves, partition and lineing with and including stainless steel cleats 02 number each sidecomplete all as specified and directed by Engr-in-Charge. |
| 29 | S&F 18/19 mm thickblock boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in cupbords shutters complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F 0.9mm thick decorative laminate type-1, of surface finish, colour and pattern as approved fixed with approved adhesive as per marker\"s instructions complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for second class hardwood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brade exc 3 Sq.cm & n.exc 6 Sq.cm with and including two coat of french polish complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F hasp and staple safety type 100 mm size, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed including taking down old one. |
| 33 | S&F in repair Curtain rod 25mm dia or Harrison rails, mild steel chromium plated with fixing brackets, stops, rollers etc. including bracket , nobs, for each window / door rodscomplete all as specified and as directed. |
| 34 | Dismantiling timber scantling 40 sqcm and over insection in any position for framed work all as specified and directed. |
| 35 | S&F for 2nd class hardwood (wrought) in scantling for timber frame and fixed complete all as specified and directed by Engr-in-Charge. |
| 36 | Refixing of timber scantling obtained from dismantling complete all as specified and directed by Engr -in-Charge. |
| 37 | M&L preparation of new / old or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 38 | M&L two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm in width and girth complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosoting complete all as specified and directed by Engr-in-Charge. |
| 40 | Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 41 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engr-in-Chage. |
| 42 | M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or paving, finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 43 | M&L for 75mm thick PCC (1:4:8) type-D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre. |
| 44 | M&L for 25mm thick (1:2:4) Type-B-1 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre. |
| 45 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry complete |
| 46 | M&L for Machine cut kota stone slab flooring 20-25mm thick of size not less than .034 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing with and including 20mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L for Kota stone slab 20-25mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in10mm thick CM (1:4) to receive Kota Stone complete all as specified and directed by Engr-in-Charge.. |
| 48 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 49 | M&L non skid coloured designer ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed by Engr-in-Charge |
| 50 | Description allas per ser item No.49 above but on skirting over with and including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L anti skid coloured ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed by Engr-in-Charge |
| 52 | M&Lglazed ceramic coloured, designer & pattern (dark & light shade combination) tilesin 350x250x7 or450x350x7 or 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4and dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge |
| 53 | M&L Granite (of any type) tiles, 20 mm thick machine cutlaid over cement screedand jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishingwith and including 20mm thick screed bed or bedding in cement mortar 1:4and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-Charge. |
| 55 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 56 | M&L RCC 1:2:4type B-1 using 20mm graded stone aggregate as in slab supported on wall, landings balconies, canopies, deck slabs and shelves etc complete all as specified and directed |
| 57 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 58 | M&L for mild steel TMT bar10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 59 | M&L for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement 1:4 complete all as specified and directed by Engr-in-Charge. |
| 60 | M&L PCC (1:1.5:3) using 12.50 mm graded aggregate laying under bottom of the sunken floor finished even and smooth dcomplete all as specified and directed by the Engr-in-Charge. |
| 61 | M&L cement concrete 1:7:12 with brick course aggregate as in filling in sunk floors complete all as directed by Engr-in-Charge. |
| 62 | M&L treatment for sunken portion with and including 10mm thick cement plaster in CM 1:3 mixed with liquid WPC @ 200ml per bag of cement when concrete surface is green.Over after dry of plaster surface two coats of industrial bitumen 85/25 laid @ 1.20Kg/Sqm incl cleaning of surface over 200 micron PVC films laid when bitumen is hot complete all as specified and directed by Engr-in-Chagre. (Note : WPC , bitumen, PVC films are inclded in the items. |
| 63 | M&L GI tubing as in spout pipe light grade 32mm bore including of required shape all as specified and directed. |
| 64 | M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete withand including taking down cement or lime plaster of any description from stone /brick/concrete wall etc incl raking out joints hacking for key scrurbbing down with water and disposing of the rubbish complete all as specified and directed by Engr-in-Charge. |
| 65 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete withand including taking down cement or lime plaster or racking of pointing and scrubbing out existing finishes on wall of any for three storey bldg incl all necessary arrangement like scaffolding and masonry complete all as specified and directed by Engr-in-Charge. |
| 66 | M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement withand including taking down cement or lime plaster of any description complete all as specified and directed by Engr-in-Charge. |
| 67 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed by Engr-in-Charge. |
| 71 | M&L for preparing new/old plastered or unplastered surfaces on walls & other surface and applying two coats of oil emulsion distemper over a coat of 3 mm wall care putty with rubbing or smoothing of surface upto ture finish over a coat of water base primer complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L preparing new/old plastered surface of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed complete all as specified and directed by Engr -in-Charge.. |
| 73 | M&L three coats of white wash on new/old plastered surfaces of ceiling including preparation of surfacces complete all as specified and directed by Engr-in-Charge.. |
| 74 | S&F 12mm thick Gypsum board for ceiling fixed with GI Powder coated snap grid 605 x 605mm frame work as in false ceiling including hangers 4mm dia GI wire (upto 1200mm centre to centre upto length as required at site) and adjusting level fixed to roof wooden member by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners complete with and including dismantling ceiling baords of any description of any thickness incl cover fillets complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws complete with and including dismantling corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and directed.completed all as specified and directed by Engr-in-Charge. |
| 76 | S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws as in ridge,eaves boards, hips, velly gutter drip and straight flushing of reuired machine moulded shape and size complete with and including dismantling plain steel sheeting, any gauge, thickness, including nainital or similar roof coverings and eaves boards of any description complete all as specified and directed.completed all as specified and directed by Engr-in-Charge. |
| 77 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F 3 Layer PPR Concealed 16mm bore pipes SDR 7.4 (PN 16) UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply at PP-R& brass threaded polypropylene random fittings laid in trenches with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F 3 Layer PPR Concealed 20mm bore pipes SDR 7.4 (PN 16) UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply at PP-R& brass threaded polypropylene random fittings laid in trenches with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 20 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 80 | M&L Lagging to pipes used in internal water supply (internal dia of pipe 20mm) or plumbing all round with,25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 all as specified and directed by the Engr-in-Charge. |
| 81 | Re-fixing old 15mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 82 | Re-fixing old 20mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 20 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F in repair Vitrous china wash hand basin, oval shape counter top of size 550 x 400 mm white fixed to RCC counter with and, 32mm dia PTMT waste coupling and 32mm dia PVC waste pipe 90cm long etc inlet and outlet connection ,inclcutting of stone wall/brick wallcomplete all as specified and directed by Engr-in-Charge. |
| 84 | S&F in repair vitreous China, squatting pan, Orissa Pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with CI trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc completeincluding provision of lime concrete bedding & making good to floor complete complete all as specified and directed including taking out old one. |
| 85 | S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed. |
| 86 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including PTMT waste copupling & waste pipe complete all as specified and directed by Engr-in-Charge. |
| 87 | S&F in repair 15 mm dia CP Wall Mixer Telephonic with Crutch (Provision for hand shower) and complete set of hand shower (Make : Prayag ) complete all as specified and directed. |
| 88 | S&F in repair 15 mm dia CP Central Hole Basin Mixer without Pop-up waste system (Make : Prayag) complete all as specified and directed. |
| 89 | S&F in repair 15 mm dia CP Sink Mixer with regular spout (W/M) (Make : Prayag) complete all as specified and directed. |
| 90 | S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed including taking down old one. |
| 91 | S&F in repair brass Chromium plated shower roses of size 125mm with or without swivel joints, any size, including fixing to steel pipe or unionincluding taking down old one. |
| 92 | S&F in repair CP angle valves (half turn type) conclead type (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed including taking down old one. |
| 93 | S&F in repair Stop valves of size 20mm dia (half turn type) , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed including taking down old one. |
| 94 | S&F in repair single/multi PVC (SWR) floor trap 75mm to 110mm dia, palin with grating including joining to waster pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F in repair 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one. |
| 96 | S&F in repairs 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 97 | S&Fin repair towel rail 600 mm long of PTMT fixed with and incl Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms). |
| 98 | S&F Corner shelves fancy type complete all as specified and directed including taking out old one. |
| 99 | S&F Stainless steel kitchen rack of size of 900 x900 x 250mm (Make : Shakti) complete all as specified and as directed. |
| 100 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed |
| 101 | S&F 75 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed |
| 102 | S&F 110 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 103 | S&F 75 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 104 | S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 105 | S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 106 | S&F 110mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge. |
| 107 | S&Frotational mouldedpolythenewaterstorage tank 1000 ltrs(cylindricalvertical with closed top) hoistedand fixed in position all as specified inSSR Part-I with and including dismantling water tank of capacity exceeding 500 liters but not excedding 1000 Ltrs and including 20mmball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete, all as specified and directed by Engr -in-Charge. |
| 108 | S&Frotational mouldedpolythenewaterstorage tank 500 ltrs(cylindricalvertical with closed top) hoistedand fixed in position all as specified inSSR Part-I with and including dismantling water tank of capacity exceeding 250 liters but not excedding 500 Ltrs and including 20mmball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete, all as specified and directed by Engr -in-Charge. |
| 109 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out from hard dense of soil complete all as specified and directed by Engr-in-Charge. |
| 110 | M&L for returning,filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge. |
| 111 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 112 | M&L Reinforced NP2 pipe of 100 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge. |
| 113 | M&L Reinforced NP2 pipe of 150 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge. |
| 114 | Cuttingintoexistingmanhole removing existing drainmakinggood to wall and rendering cutting out branch channeland makinggood benchingfor 100mm dia pipe incement concrete 1:2:4 complete all as specified and directed by Engr-in-Charge. |
| 115 | Description all as per ser item No 114 above but 150mm dia |
| 116 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork built in cement mortarcomplete all as specified and directed by the Engr-in-Charge. |
| 117 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed by Engr-in-Charge. |
| 118 | M&L for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole cover slab and similar article with plain faces, set in cement 1:4 complete all as specified and directed by Engr-in-Charge. |
| 119 | S&F TMT Mild Steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.. |
| 120 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 121 | M&L for PCC 1:2:4type B1 (12.5mm graded aggregate ) asin copingincluding necessary form work complete all as specified and directed by Engr-in-Charge. |
| 122 | Dismantling fencing wire mesh n.exe 4kg, any type and in any position & separating them the serviceable & unserviceable materials and removing the unserviceable wire mesh from work site as directed |
| 123 | Supply only Chain linkMS galvanised fencing, any size or type complete all as specified and as directed. |
| 124 | Fixing only chain link fencing including line wire any mesh, size and type to any type of standards rails staining bolts etc including provision of binding wire complete all as specified and as directed |
| 125 | M&L100mm thick plain cment concrete type D-2,1:4:8 (using 40mm graded crushed stone aggregate as in hard standing |
| 126 | M&L Sand filling under floors or in foundations including watering and consolidation |
| 127 | M&L Machine pressed precast, cement concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Gradecomplete all as specified and as directed. |
| 128 | Taking down carefully copper/aluminium point wiring from woodenbattan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc. |
| 129 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 130 | Taking down old MCCB,TPN DBs , SPN DBs alongwith SP/SPN MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 131 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following : |
| 132 | (a)One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely) |
| 133 | (b)One bell point controlled by one by one way switch (switch to be measured and paid separtely) |
| 134 | (c)One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. |
| 135 | (d)Description all as per ser item No 134 (c) but Same board. |
| 136 | (e) One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately) |
| 137 | M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in concealedNew PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.Note: Three runs of 6 sqmmcable and one run of PVC conduitshall be measured as one RM. |
| 138 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid in concealedNew PVC conduit and conduit accessories complete all as specified and directed. |
| 139 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 140 | M&L in replacement Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 141 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 142 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 143 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 144 | Suppy & fixing DBOXx MCB Protected Socket 15 Amps , PVC Plastic Base (white) with Plug top 25 Amps & MCB SP 32 amps complete all as specified and directed.Make : Anchor Roma /Legrand/indoasian.Note : 15 A switch to be provided near wash basing and separate socket to be provided near geyser rate to be included in quoated rate same for AC also. |
| 145 | M&L ceiling rose 3 phase PVCpolycorbonate,isolated body. |
| 146 | M&L bell ding dong AC,230 volts,single pole all as specified and directed by Engr in Charge. |
| 147 | Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings completeallas specified and directed. Note : All servicable fittings will be deposited to MES yard. |
| 148 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 4000 to 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed with 2 years of replacement warranty on fittings complete all as specified and directed. Note : All servicable fittings will be deposited to MES yard. |
| 149 | Supply and fix not less than 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 150 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coatedcomplete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating. Against def |
| 151 | S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 152 | Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connectionand checking it for its serviceability and deposite to MES store as specified and directed. The same will be refix as directed by Engr-in-charge. |
| 153 | Supply and fixing Exhaust fan300 mm sweep(steel Body) , 900 RPM, steel body including metalic blade ,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 154 | Supply and fixing Ventilating Fan250 mm sweep, 900 RPM, non metallic resin body,single phase 230 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 155 | M&L for breaking old existing wall and making a provn for fixing of300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed. |
| 156 | Supply and fixing ceiling fans complete with blade, down rods, electronic regulator and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMMBEEfive star rated voltage range 140 - 280 volts power factor > .9 and THD < 20 %with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. Note : Down rods length should be as per site requirement. Against def. |
| 157 | M&L earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. |
| 158 | S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection single door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete |
| 159 | M&L MCB ISOLATOR SPN 40 Amp complete all as specified and directed. |
| 160 | S&F MCB SP 6-32 Amps 240 volts \"B\" curve series 10 KA 50 HZ complete all as specified and directed. |
| 161 | Taking down old unservicable cable of any size or typefrom any description (trenches, walls, ceilings., etc) from various locations, including any short length,all as specified & directed. |
| 162 | Supply and Layingjointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 50 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 163 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected |
| 164 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed. |
| 165 | Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed |
| 166 | Taking out/taking down old unserviceable damaged GI/PPR pipe of 50 mm diafrom trenches/Wall/roof including removing of fittings all as directed fby Engineer in Charge. |
| 167 | Description all as per ser item No 166 above but20 mm dia. |
| 168 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 50 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 169 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 20 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 170 | M&L Lagging on pipes of internal dia upto 20 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs , complete, all as specified and directed. |
| 171 | Making connection of PPR distribution branch with PPR main ofsizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 172 | Making connection of PPR distribution branch with PPR main ofsizes 50 mm to 75 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 173 | Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 50 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 174 | Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 20 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 175 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail