| 1 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 2 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 3 | Material & labour Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary s&f lugs, Butthinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either sidecomplete all as specified and directed. |
| 4 | Description all as per item No-03 butsize of frame 105x60mm complete all as specified and directed. . |
| 5 | M & L PCC 1:2:4type B0 12 .5 mm graded aggregatecement concrete as filling to pressed steel frames complete all as specified and directed. |
| 6 | S&F factory made Box Type mild steel windows side hung glazed shutters with chowkets with glazing bars to receive glass and other side of the window wire mesh shutters to receive wiremesh orwire guage dovetailed or welded and steel peg stay with and including necessary welding, reveting, tower bolt, hanlde, holdfast & hinges as per Drg No.CESZ/TD-1018/2011 Sheet No 1/3 complete all as specified and directed by Engr-in-Charge. (Note : Guard barsshall be mensurementand paid separately). |
| 7 | M&L PCC 1:2:4 type B0 12.5mm graded aggregatte as in hold fasts and bed blocks etc including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 8 | Dismantling wrought iron or mild steel work (used in framework for stageing of water tank) of any description not otherwise provided for all as specified. |
| 9 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 10 | S&F 35 mm thick, factory made 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20(a), fitted to chowkats complete all as directed. |
| 11 | S&F 35mm factory made shutters plain framed, panelled shutterwith lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-Charge. |
| 12 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed. |
| 13 | S&F sheet glass 4.00 mm thick ordinary quality and glazing with oil putty in square, rectangle n.exc 0.5 Sqm in each pan all as specified and as directed by Engr-in-Charge. |
| 14 | S&F Floor door stopper of aluminum alloy body and tongue anodized with hard drawn steel spring fixed in floor of length 150mm complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed. |
| 16 | S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed. |
| 18 | S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed . |
| 19 | S&F in repair Curtain rod or Harrison rails, mild steel chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 20 | Dismantiling timber scantling 40 sqcm and over insection in any position for framed work all as specified and directed. |
| 21 | S&F for 2nd class hardwood (wrought) in scantling for timber frame and fixed complete all as specified and directed by Engr-in-Charge. |
| 22 | Refixing of timber scantling obtained from dismantling complete all as specified and directed by Engr -in-Charge. |
| 23 | M&L preparation of new / old or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 24 | M&L two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm in width and girth complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosoting complete all as specified and directed by Engr-in-Charge. |
| 26 | Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 27 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engr-in-Chage. |
| 28 | M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or paving, finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for 25mm thick (1:2:4) Type-B-1 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre. |
| 30 | M&L for machine cut kota stone slab flooring 20-25mm thick of size not less than .034 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 20mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for kota stone slab 20-25mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in10mm thick CM (1:4) to receive Kota Stone complete all as specified and directed by Engr-in-Charge. |
| 32 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry complete all as specified and directed. |
| 33 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 34 | M&Lglazed ceramic coloured, designer & pattern (dark & light shade combination) tilesin 350x250x7 or450x350x7 or 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4andcomplete all as specified and directed by Engr-in-Charge |
| 35 | M&L anti skid coloured ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed by Engr-in-Charge |
| 36 | M&L Granite (of any type) tiles, 20 mm thick machine cutlaid over cement screedand jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishingwith and including 20mm thick screed bed or bedding in cement mortar 1:4and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed by Engr-in-Charge. |
| 37 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L non skid coloured designer ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed by Engr-in-Charge |
| 39 | Description all as per item No.38 above but on skirting over with and including 10mm thick backing coat in CM 1:4complete all as specified and directed by Engr-in-Charge. |
| 40 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 41 | M&L RCC 1:2:4type B-1 using 20mm graded stone aggregate as in slab supported on wall, landings balconies, canopies, deck slabs and shelves etc complete all as specified and directed |
| 42 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 43 | S & F mild steel TMT bar10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 44 | M&L for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement 1:4 complete all as specified and directed by Engr-in-Charge. |
| 45 | M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F 15 mm dia steel water GI tube medium grade with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F 20 mm dia steel water GI tube medium grade with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 20 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 48 | M&L for lagging to pipes used in internal water supply (internal dia of pipe 20mm) or plumbing all round with,25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 all as specified and directed by the Engr-in-Charge. |
| 49 | Re-fixing old 15mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 50 | Re-fixing old 20mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 20 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F in repair vitrous china wash hand basin, oval shape counter top of size 550 x 400 mm white fixed to RCC counter with and, 32mm dia PTMT waste coupling and 32mm dia PVC waste pipe 90cm long etc inlet and outlet connection ,inclcutting of stone wall/brick wallcomplete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in repair vitreous China, squatting pan, Orissa Pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with CI trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc completeincluding provision of lime concrete bedding & making good to floor complete complete all as specified and directed including taking out old one complete all as specified and directed. |
| 53 | S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed. |
| 54 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including PTMT waste copupling & waste pipe complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F in repair Stop valves of size 20mm dia (half turn type) , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed including taking down old one. |
| 56 | S&F in repair single/multi PVC (SWR) floor trap 75mm to 110mm dia, palin with grating including joining to waster pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F in repair 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one complete all as specified and directed. . |
| 58 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed |
| 59 | S&F 75 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed |
| 60 | S&F 110 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 61 | S&F 75 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed |
| 62 | S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 64 | S&F 110mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge. |
| 65 | S&Frotational mouldedpolythenewaterstorage tank 1000 ltrs(cylindricalvertical with closed top) hoistedand fixed in position all as specified inSSR Part-I with and including dismantling water tank of capacity exceeding 500 liters but not excedding 1000 Ltrs and including 20mmball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete, all as specified and directed by Engr -in-Charge. |
| 66 | M&L in repairs second class soft wood weather boarding clean sawn,plain 20mm thk or feather edge 15 to 20mm thk and fixed with 30mm laps complete all as specified and directed by Engr-in-Charge. |
| 67 | M&L in repairs second class planed one side, with butt joints and fixed with nails supplied and fixed30mm thk or feather edge 15 to 20mm thk and fixed with 30mm laps complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete withand including taking down cement or lime plaster of any description from stone /brick/concrete wall etc incl raking out joints hacking for key scrurbbing down with water and disposing of the rubbish complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete withand including taking down cement or lime plaster or racking of pointing and scrubbing out existing finishes on wall of any for three storey bldg incl all necessary arrangement like scaffolding and masonry complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 71 | M&L brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 73 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed by Engr-in-Charge. |
| 74 | M&L for preparing new/old plastered or unplastered surfaces on walls & other surface and applying two coats of oil emulsion distemper over a coat of 3 mm wall care putty with rubbing or smoothing of surface upto ture finish over a coat of water base primer complete all as specified and directed by Engr-in-Charge. |
| 75 | M&L preparing new/old plastered surface of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed complete all as specified and directed by Engr -in-Charge.. |
| 76 | S&F 12mm thick gypsum board for ceiling fixed with GI Powder coated snap grid 605 x 605mm frame work as in false ceiling including hangers 4mm dia GI wire (upto 1200mm centre to centre upto length as required at site) and adjusting level fixed to roof wooden member by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners complete with and including dismantling ceiling baords of any description of any thickness incl cover fillets complete all as specified and directed by Engr-in-Charge. |
| 77 | M&L for factory made 60mm thick non skid pre-polished coloured interlocking paver block made with grey Cement and pigment not less than compresive strength 35 Kg/Cm (M-35) sqm laid over and including 25mm thick dry sand coushoining complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws complete with and including dismantling corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and directed.completed all as specified and directed by Engr-in-Charge. |
| 79 | S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws as in ridge,eaves boards, hips, velly gutter drip and straight flushing of reuired machine moulded shape and size complete with and including dismantling plain steel sheeting, any gauge, thickness, including nainital or similar roof coverings and eaves boards of any description complete all as specified and directed.completed all as specified and directed by Engr-in-Charge. |
| 80 | S&F in repairs 18/19 mm thickblock boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in shelves, partition and lineing with and including stainless steel cleats 02 number each sidecomplete all as specified and directed by Engr-in-Charge. |
| 81 | S&F 18/19 mm thickblock boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in cupbords shutters complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F 0.9mm thick decorative laminate type-1, of surface finish, colour and pattern as approved fixed with approved adhesive as per marker\"s instructions complete all as specified and directed by Engr-in-Charge. |
| 83 | M&L three coats of white wash on new/old plastered surfaces of ceiling including preparation of surfacces complete all as specified and directed by Engr-in-Charge.. |
| 84 | S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed including taking down old one. |
| 85 | S&F in repair CP angle valves (half turn type) conclead type (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed including taking down old one. |
| 86 | M&L preparing old plastered or unplastered surfaces of walls and applying two coats of white wash on old decorated surface complete all as specified and directed by Engr-in-Charge. |
| 87 | Excavation in trenches n.exc 1.5 M wide and n.exc 1.5m deep as in soft/loose soil for foundation etc or for shaft walls, cesspit, manhole etc n.exc 10Sqm on plan complete all as specified and directed. |
| 88 | Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 89 | Returning, filling including spreading, levelling and well ramming in layers not exceeding 25 cm in each layer as in hard / dense soil complete all as specified and directed. . |
| 90 | M & L for PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 91 | M & Lfor hard core of broken stone bolder of gauge 63mm complete all as specified and directed. |
| 92 | M & L for cement concrete (1:5:10) Type E2 using 40mm graded aggregatein foundations, filling and mass concrete |
| 93 | M & L for 75mm thick cement concret 1:2:4 Type B-2 using 40mm graded stone as in flooring andfinishing cementconcrete surface even and smooth using extra cement all as spd and directed |
| 94 | M & L for 75mm thick PCC (1:3:6) type C2 Using 40mm graded stone aggregate as in plinth protection hard standing and finished the surfaces even and smooth with out using extra cement complete all as sdpdand as directed |
| 95 | M & L for brick work with locally available sub class ‘B’, old size, best quality bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) all as specified and directed. |
| 96 | M & L earth filling under floor spreading and levelling in layers n exc 25 cm thick for well ramming watering required. |
| 97 | M&L for 15 mm thick rendering in CM 1:4 in finishing the surface even and smooth without using extra cement. (Liquid WPC shall be measured and paid seperately) |
| 98 | M&L for 15 mm thick plaster on fair faces of brick or concrete surfaces in CM 1:6 finshed even and smooth without using extra cement complete all as specified and directed. |
| 99 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint and over one coat of alkali resistent priming paint complete all as specified and directed. |
| 100 | M & Lfor three coat of white wash in cluding prep of wall surface complete all as specified and directed. |
| 101 | M & L for 40mm thick PCC (1:2:4) type B1 Using 20mm graded crushed stone aggregate with liquid type water proofing compound as per manufacturers instruction (Note:- 200ml liquid wpc /bag of cementshall calculated and paid seperately complete all as specified and directed. |
| 102 | Supply only liqiuid water proofing compoundcomplete all as specified and directed. |
| 103 | S&F steel windows with side hung shutters including box type hinges with one No MS handle per leaf made of FI 25 x 3 mm made to shape Appx 200 mm in length and two Nos 150mm long MS tower bolt welded to each shutter including 150 mm long peg stay, complete with glazing bars, dovetailed or welded all as specified. |
| 104 | Description all per ser item No 103 above but without glazing bars complete all as specified. |
| 105 | S&F steel ventilator with top hung shutters including box type hinges with steel hndle and steel peg stay,MS 10mm square guard bar, Glazing bar devotailed or welded for receving glass and including cutting holes in walls for fixing the window with hold fast in PCC (1:3:6) type C1 (using 20mm graded aggregtetes ) and making good the disturbed surfaces in CM (1:4) and with the existing finishes to match complete all as specified and directed. |
| 106 | S&Fframed wrk such as grills, grating etc with ends of bars shouldered and/or rivited or forged into spikes: framed guard bars;barried iron doors ladders,framed balasters walk ways railing framed work of water and simler work confirming to Fe-410-0 or 310-0-using 12mm square bar cmplete all as specified and directed. |
| 107 | S&F roof trusses (framed), trussed purlins crane gantries rails and fastening and heavy bracketframing beam ,tee angle channel or flat section ) including distance pieces cleat etc FE 410 W(Gde E-250) A quality complete all as spd and directed |
| 108 | M & Lfor pre painted galvalume alumimum zinc coating GI based corrugated steel sheet .50 mm thick of an colour having tensiles strength of 550 mpa as in roof covering/clading to wall fixed with self tapping screws complete all as spd and directed |
| 109 | M & Lfor Pre-painted galvalumealuminum zinc coating GIbased Plain steel sheet0.50mm thick of anycolour having tensilestrength of 550 Mpa as inroof covering/cladding towall, fixed with selftapping screws asspecified |
| 110 | S&F for galvanised mild steel cloth of 0.56mm nominal dia wire average width of aperture 1.18mm fixed with tinned tacks or galvanised wire stapples or wooden beads for wooden shutters complete all as specified and directed. |
| 111 | S&F sheet glass 3mm thick ordinary quality and fixed to steel or wooden frame withold putting or wooden beads n.exc 0.5 sqm each pane complete all as specified and directed. |
| 112 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described. |
| 113 | Taking down carefully copper/aluminium point wiring from woodenbattan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc complete all as specified and directed. |
| 114 | Taking down old MCCB,TPN DBs , SPN DBs,SP MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 115 | Taking down old sub main wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 116 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing through PVC conduit/ Casing/Capping on Surface mounted FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following : |
| 117 | (a)One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely) |
| 118 | (b)One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. |
| 119 | (c)Description all as per item No 116 above but Same board. |
| 120 | M&L for One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately) |
| 121 | M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in and including PVC conduit ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. |
| 122 | S&F in Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit/Casing Cappingand conduit accessories on surface of walls complete all as specified and directed. |
| 123 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 124 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 125 | M&L in replacement socket outlet6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 126 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 127 | M&L ceiling rose 3 phase PVCpolycorbonate,isolated body complete all as specified and directed by Engineer in charge . |
| 128 | Supply and fix LED batten luminaire surface mounted T-8, 4 feet system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 129 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥80 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 130 | Supply and fixing70 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 131 | Supply and fixing Exhaust fan heavy duty380 mm sweep(steel Body) , 1250 RPM, metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 132 | Supply and fixingfactory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified. |
| 133 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25x4 mm size as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed. |
| 134 | S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with 200 Amp rated bus bar,neutral link earth link complete all as specified and directed by Engr-In- Charge. |
| 135 | S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed. |
| 136 | Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connectionand checking its for its serviceability and deposite to MES store and as directed by Engineer-in- charge. |
| 137 | Hanging only ceiling fan any size (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan. |
| 138 | Taking down carefully the existing Geyser of 25/50 ltr from its position after disconnecting electric connectionand checking its for its serviceability and re-fixing with connection pipe hot/cold as specified and directed by Engineer-in- charge. |
| 139 | Supply and fixMCB SPN 32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge |
| 140 | Supply and fix in MCCB 160 Amps, FP 415 volts 36 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 141 | Supply and fixMCB SP 5-32 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge |
| 142 | Taking down old unservicable cable of any size or typefrom any description (trenches, walls, ceilings., etc) from various locations, including any short length,all as specified & directed. |
| 143 | Supply and Layingjointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 144 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 10 cm deep over the cable including well punning complete all as specified and dierected |
| 145 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed. |
| 146 | S&F in Sub main wiring with two runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 147 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 148 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 149 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 150 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 151 | S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete |
| 152 | S&F LED 2 X 2 ft backlite surface mounted fitting 36 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours ,Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 153 | Supply and fixing ceiling fans complete with blade, down rods, electronic regulator and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMMBEEfive star rated voltage range 140 - 280 volts power factor > .9 and THD < 20 %with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. Note : Hook & Down rods length should be as per site requirement. |
| 154 | Supply and fix MCCB 3 pole ,125 Amps, FP 415 volts 36K 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer- In -Charge |
| 155 | Supply and fixMCB DP 32-40 Amps240 volts 10 KA 50 HZ\"B\" curve complete all as specified and directed by Engineer in charge |
| 156 | Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed |
| 157 | Taking out/taking down old unserviceable damaged GI/PPR pipe of 25 or 32 mm dia sizes from trenches/Wall/roof including removing of fittings all as directed fby Engineer in Charge. |
| 158 | Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 25 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc. |
| 159 | M&L for lagging on pipes of internal dia upto 25 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs , complete, all as specified and directed. |
| 160 | M&L for making connection of PPR distribution branch with PPR main ofsizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 161 | Supply & fixingPP-R Gate valves (brass insert) ISI markedof external dia 25 mm as per requirement of the site and as directed by Engineer-in Charge. |
| 162 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail