Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART I (B/R WORKS)Chipping loose concrete and Exposing existing RCC columns, beams, slabs, lintels, pardis, etc. including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding, erecting horizontal platforms at working levels to collect the debris, proping with top and bottom runners as directed stacking the debris in the compound as directed and carting away the same outside the premises etc. complete. |
| 2 | RELIEVING STRUCTURAL MEMBERS Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately |
| 3 | Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main r/f. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing r/f. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directedProviding and applying “Polyalk EP” or equivalent as specified in the Brand Names.Polymer modified cement mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering. |
| 4 | Jacketting the existing column of size as shown inthedrawingof structural audit report by removing theconcretecovertoreinforcement,bychippingor othersuitablemeanstoexposethe reinforcementofexisting column in order to make available the sameforbindingtheextra reinforcement as shown in the drawingandalsoremovalofrust,scales of the reinforcement in order toprovideand apply approved make of epoxy resin to get proper bondwithnewly laid M25 grade concrete.The aforesaidconcreteshallbelaidby the sidesoftheexistingcolumnwithuniformthicknessof 115 mmoras specified, for jacketingpurposestherebyincreasing the sectional dimensions by 150 mm or as specified (excluding finishing)at any height withrequisiteshuttering,centring,scaffolding,proping, repairingtheexistingsurfaceasspecifiedandalso removal ofdebris,curing etc. completeasperdesignanddrawingetc. directed.(NOTE :- Reinforcementwillbepaidseparatelyunderrespective item ofschedule ). |
| 5 | Excavation for foundations, substructures, basements, tanks, sumps, walls, chambers, manholes, trenches, poles, pits & general building works in all types of soils, vegetable earth, soft murum, running sand, shingle, turf clay, loam, peat, ash, shale, slag, chalk, garbage, muddy/ marshy/ slushy soil, marine clay, reclaimed land etc for depths/ lifts upto 1.5M measured from the ground level, including dressing/ trimming the sides, leveling and ramming of bottoms,manual dewatering, removing rank vegetation, backfilling in layers notmore than 200mm thickness, watering, consolidating, compacting to achieve not less then 97% Modified Proctor density conforming torelevant IS, stacking the Selected material in measurable heaps forfuture use within owners space or disposing within an initial lead of 150m as directed, loading, unloading, leveling excluding shoring, strutting etc. complete as directed by Engineer in Charge.Note:1 The rate includes the handling/supporting the existing utilities such as cables, drains, pipes,water mains etc.2. It also includes the royalty and other taxes applicable if any. For more details refer General Notes |
| 6 | Providing & Laying dry stone Rubble Soling with average 230 mm size hard stone set in regular lines, handpacked and interstices thoroughly filled with small chips including filling in with good quality murum brought from outside, compacting with iron rammers, watering, sand spreading 12mm thick. layer of grit on top etc complete as directed by Engineer In Charge.(Note: The rate includes the royalty and other taxes if any) |
| 7 | Providing and laying in position plain cement concrete of specified grade with trap/ granite/ quartzite/ gneiss metal mixing in concrete mixer including bailing out water, compacting, finishing surface, curing and including the cost of centering and shuttering at all level Nominal Mix of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | FILLING AND REINSTATING OF SEPARATION CRACKSOpening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully / carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed. |
| 9 | Moistening the Cracks, Providing and applying priming/ bonding coat of slurry made out of“Polyalk EP” and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks / Grooves by Providing and applying “Polyalk EP” Polymer modified cement mortar (or equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed. |
| 10 | Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same as directed. |
| 11 | Providing and fixing 12 mm diameter aluminum /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ at the rate of 225 grams per bag of cement and using suitable mechanical gun/ pump including mixing etc complete. |
| 12 | Providing & fixing epoxy dipped shear keys of 10mm dia and 4\" to 6\" length in columns before jacketing, Micro concreting as per Consultants Instructions and directions. |
| 13 | Providing, cutting, bending and fixing Additional Reinforcement in position steel reinforcement of specified/ required sizes and shapes in the formor main rebars, stirrups & rings,distribution rebars etc., and tying them toshear connectors using GI binding wire. The additional rebars should be coated withTWOcoats of AntiCorrosive protective coating& dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants. |
| 14 | Providing and laying Super fluid Microconcrete -Roffe crete repairs (or equivalent as pecified in the List of Brand names)in beam bottoms, columns, slabs etc. including mixing with 5mm to 10mm size aggregates, waterproofply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification and Consultants Instructions.The item shall be paid on actual consumption of Micro concrete. |
| 15 | Carefully Chiseling/ Chipping out all existing loose decayed Plaster ofExternal Facades and Terrace area (In Entire areas) using Plaster Breaking machine and or Well sharpened Chisel & Hammers at proper angles carting away the Debris outside of bldg Premises etc complete as directed by the Consultants,Providing and applying 20/25 mm thks and faced plaster to concrete members- brick work etc.of External wall facades using approved screened and Pre washed River sand including base coat of 13-15mm thick in C.M. 1:4 and curing the same for not less than three days and keeping the surface of base coat rough to receive the sand face treatment 6 to 8 mm thick of C. M 1:3 finishing the surface by taking out grains and curing for 7- 10 days, providing and mixing approved waterproofing compound in required quantities in both the coats complete. |
| 16 | Chipping out all existing loose and decayed internal plaster and redoing the same with 15mmthk. Cement plaster in CM (1:4) finishing with ‘Instant Neeru’ of Elephant Brand or equivalent in the inside areas of staircase areas and over Internal Structural Members of premises, etc . |
| 17 | Removing and demolishing the existing waterproofing upto slab level of any thickness, stacking the excavated debris on the ground floor, in the compound of the building carting away the same outside the MES premises. |
| 18 | MES Item no:13036 +13040 M & L for Cement concretetype B-1, 1:2:4 (20mm graded aggregate) 40mm thick in floors finishing the surfaces even & smooth without using extra cement |
| 19 | MES Item no:11068 APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/ sqm) land on primed surface by forced application complete all as specified |
| 20 | MES Item no:13093+14009+14010 Cement concrete tiles 25cm x 25cmx 22mm thick, machinepressed; set jointed and pointed in neat cement slurry in floors, and cut and polished over 20mm cenent screed (1:4) |
| 21 | Carefully Chiseling/ Chipping out existing cracked /damaged IPS and Providing I.P.S. Finish over Chajja Tops,staircase room top & OH/WT etclaying Brick bats/ Metal pieces to the desired thickness and slope finished with cement mortar plaster of specified and required thk. in CM (1:4), with neat cement slurry including waterproofing compound, curing etc including making junction wattas etc complete as specified and directed. |
| 22 | Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land |
| 23 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) for MHcomplete all as specified |
| 24 | Taking down cement plaster of any description in any positionincluding racking out joints making key scrubbing down with water etc. and removal of debris out side MD land. |
| 25 | M&L 10 mm thick CM 1:4 ready mix plaster , on fair faces of brick work or concrete surfaces andsurfaces finished even and smoothincluding necessary scaffolding complete all as specified and directed. |
| 26 | M&L 5 mm thickCM 1:4 ready mixplaster overconcrete surfaces of ceiling surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified and directed. |
| 27 | M & L for 10+5 mmthick cm 1:4 ready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified Note : Water proofing compound shall be measured & paid seperately. |
| 28 | M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over a coat of alkali resistant primer.etc complete all as specified and directed . |
| 29 | M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed . |
| 30 | M & L for preparation of new plastered surfaces on ceiling and applying two coats of white wash with complete all as specified and directed. |
| 31 | M & L for preparation of new plastered surfaces on ceiling and applying two coats ofoil bound distempecomplete all as specified and directed. |
| 32 | M & L for preparation of old plastered surfaces on ceiling and applying two coats ofoil bound distempecomplete all as specified and directed. |
| 33 | M&L for complete removal of existing surfaceson ceiling and applying two coats of white wash with complete all as specified and directed. |
| 34 | M&L for preparation of NEW plastered walls surfaces for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 35 | M&L for complete removal of existing surfaces including washing / rubbing down with water of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 36 | Demolition of cement concrete unreinforcedin ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 37 | M &L PCC 1:3:6 type C2 75mm thick as in plinth protection finished even and smooth using extra cementcompete all as specified. |
| 38 | 75mm thick cement Concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in floor/sub base and finished even and fair complete,all as specified and directed. |
| 39 | M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 40 | M&Lfor Machine pressed precast concrete inter locking paver blocks of any shape andsize conforming to IS 15658- 2006of 60 mm thick M-35 grade with grey cement andpigment with glosey finish andincluding removing the existing paver blockscomplete all as specified and directed.. |
| 41 | Dismantling floor, hearth or wall tiling including cementmortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc complete all as specified and directed. |
| 42 | Dismantling stone slabs or pcc tiles of any description or thickness in steps, landing, flooring and similar work laid, bedded and pointed in cement mortar complete. |
| 43 | M/L for 15 to 20mm machine cut kota stone slab as inriser of steps, skirting, dado and pillar, cills and jambslaid overcement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andpolishing with beewax polishand including over 15mm thick screed bed or bedding layer inCM1:4 complete all as specified and as directed by EIC |
| 44 | M&L machine cut kota stone slab flooring 20 - 25mm thick over 20mm cement screed in CM 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shad of the slab includingmirror polishing complete all as specified and as directed by EIC |
| 45 | M&L coloured (light shade) vitrified ceramic tiles of size 600mm x 600mm x 8mm thick in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.incl 15 mm thick screed bed in cement mortar 1:6including finishing even and fair complete all as specified. |
| 46 | M&L coloured (light shade) vitrified ceramic tiles of size 600mm x 600mm x 8mm thick on vertical wall skirting etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as rendering cement plaster, 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive tilescomplete all as specified and directed. |
| 47 | M&L Non skid ceramic colored tiles, edge cut 7 to 8mm thick square or rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18mm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile incl 15 mm thick screed bed in cement mortar 1:4including finishing even and fair complete all as specified. |
| 48 | M&L Coloured glazed ceramic tiles of size 350x 450 x 7mm thick,on vertical wall surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces increndering cement plaster, 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive tilescomplete all as specified and directed. |
| 49 | Taking down chowkats of frames with shutters (without taking off shutters from frames) area exceeding1.50 Sqm but n exc 4 sq. m each, including cutting holes for taking out hold fasts or dismantling brick work(holes cut and anyother damages to jambs , walls for taking out hold fast shall be finished idetical to existingfinish without anyall as specified and directed by Engr- in - charge |
| 50 | Taking down chowkats of frames with shutters (without taking off shutters from frames) area not exceeding1.50 Sqmeach, including cutting holes for taking out hold fasts or dismantling brick work(holes cut and anyother damages to jambs , walls for taking out hold fast shall be finished idetical to existingfinish without any extra cost of Govt) all as specified and directed by Engr- in - charge |
| 51 | Dismantling of boarding ,any description and in any position complete all as specified and directed |
| 52 | M&L for 18/19 mm Prelaminated particleboard, interior grade, prelaminated oneside with decorativechoice lamination &otherside balancingwhite lamination,fixed with screws totimber framework all as specified and directed. |
| 53 | S&F 2nd Class Hard Wood: Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed , put together with glue pinned at joints complete all as specified. |
| 54 | S&F factory made 35mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 55 | S&F 35 mm thick, 2nd class hard wood factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed. |
| 56 | S&F extruded Powder coated aluminiumsection as in Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specifiedand alldirected |
| 57 | S&F 4.8mm thickglass selected quality ineach pane for aluminimum door shutters, aluminium partition wall and slidingwindows/ventilatorshutters etc including rubber beading or gasket for aluminium sectionn exc .5 Sqm complete all as specified. |
| 58 | S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 59 | S & F aluminium grill conforming to DG- 102 of Deco Grill or equivalent , (10mm X 5.2mm) thickof approved design or equivalent as approved by Accepting Officer and fixing with and including \"F/U\" channel not less than1.5mm thick complete all as specified and directed. |
| 60 | S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as specified and directed. |
| 61 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed |
| 62 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of exturded sections or cast aluminium alloy all as specified and directed |
| 63 | S&F 150 mm long aluminium bow handles cast type anodised. |
| 64 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section. |
| 65 | S&Fbutt hinges med weight cold rolled MS, size 100 mm. |
| 66 | S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate completecomplete all as specified and directed |
| 67 | M&L for preparation of new wooden surfaces of any description not otherwise describedover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 68 | M&L forpreparation of old wooden surfaces of any description not otherwise describedover 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 69 | Taking up or down steel tubing 15 mm bore of pipe and connectionsincluding cleaning for refixing etc as required complete all as specified and directed. |
| 70 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nominal Outer diameter of pipes16 mm complete all as specified. |
| 71 | Taking up or down steel tubing with connectionsfor cleaning for refixing or removing to store yard complete of bore 20 mm complete all as specified. |
| 72 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nominal Outer diameter of pipes20 mm complete all as specified. |
| 73 | Taking up or down steel tubing with connectionsfor cleaning for refixing or removing to store yard complete of bore 25 mm complete all as specified. |
| 74 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nomina Outer diameter of pipes25 mm complete all as specified. |
| 75 | Taking up or down steel tubing with connectionsfor cleaning for refixing or removing to store yard complete of bore 32 mm complete all as specified. |
| 76 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nominal Outer diameter of pipes32 mm complete all as specified. |
| 77 | Taking up or down steel tubing with connectionsfor cleaning for refixing or removing to store yard complete of bore 40 mm complete all as specified. |
| 78 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nominal Outer diameter of pipes40 mm complete all as specified. |
| 79 | Demolition carefully RCC work as in, Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended worketc by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of debris out side the MOD land. complete all as specified and directed. |
| 80 | M & L for RCC 1:1.5:3type B0(12.5mm graded aggregate) nominalmix as in repair old rcc tankon walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs andin the shelves and the like complete all as specified and directed. |
| 81 | M & L for Use and waste ofFormwork to soffits of suspended slabs such as roof slabs, water tank stagingfloor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)for flat and rough surfaces complete all as specified and directed. |
| 82 | M & L TMT bars 10mm dia and over cut to length, bent to shape reqd, inculding cranking,bending spirally for hooping for Columns, hooking ends and binding with and incl MS wire(annealed) not less than .90mm dia complete all as specified and directed. |
| 83 | M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 2000 ltrs capacity complete all as specified and directed.. |
| 84 | M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete25mm dia complete all as specified and directed. |
| 85 | M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed |
| 86 | M&L Waste fittings, brass, chromium plated for glazed ware sinks,asins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed waste fitting of 40 mm bore, brass, chromium plated for glazed ware wash basin etc |
| 87 | S&F in repairs vitreous China squatting pan, \"orrisa\" pattern WC of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe but including \"P\" or \"S\" trapand provision of lime concrete beddingcomplete all as specified and directed. |
| 88 | M&L PVC valveless, syphonic action type, 10 ltrs cap flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs complete all as specified and directed. |
| 89 | S & F Mirror 900mm x 600 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plughs with chromium plated brass screws and cup washers in repairs complete all as specified and directed. |
| 90 | M&L Mirror 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plughs with chromium plated brass screws and cup washers in repairs complete all as specified and directed. |
| 91 | M&L Wash basin, Vitreous China white (Flat back) 630 x 450mmincluding fixinggranit top with ceramic under counter basinpinning in ends of brackets or erecting stand including fixing of waste pipe andetc ( Suppy of pillar tap and waste pipe shall be measured separately) complete all as specified and directed. |
| 92 | M&L32 mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins,glazed ware wash basinetc. with long screwed shanksand fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 93 | S &F15 mm Pillar taps, castcopper alloy, withcapstan heads,chromium plated, screwed down highpressure, with orwithout lettered\"Hot\" or \"Cold\" withlong screwedshanks and fly-nuts, screwed for ironpipe and fixed |
| 94 | S & F15.00 mm Angle stop valve ofPTMTanycolourhigh pressure screwedfor iron pipe andfixed, (Minimum weight15mm-90gms) |
| 95 | S & Fstop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions in repairs complete all as specified and directed. |
| 96 | S &F 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 PVC bends including all necessaryfixed complete to walls, ceilings or in floors etc. |
| 97 | S&F Bib taps, castcopper alloy withcrutch orbutterflyhandle, screweddown, screwed foriron pipe or forbrass ferrule andfixed |
| 98 | S&F in repair 25 mm fancy type decorative stainless steel double curtain road with doublebracket suitable hanging multiple sets curtains togetherfor window and doorincluding 02 nosedoublebracket and04 nosefancytype rod for each window make- Vist,Marvel,mac decor ,declor equivalent complete all as specified and directed. |
| 99 | S&F Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) |
| 100 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. ® |
| 101 | S&F in repairs brass chromium plated towel rail 20mm dia, \"D\" type, 600mm long between flanges. |
| 102 | S&F stainless steel soap dishes approximate size 160mm x 160mm x90mm as complete as specified as directed by Engineer-in-Charge. |
| 103 | S&F Glass Assembly sheet glass consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracked guard and railing 60cm long in repairs complete all as specified and directed.. |
| 104 | S&F Brass chromium plated shower rose 125mm size including fixing to steel pipe or union in repairs complete all as specified and directed. |
| 105 | S&F20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed |
| 106 | S&F 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed |
| 107 | Taking down AC rain water pipe any size or pattern incl all fittings heads, shoes, bends. Swan necks, etc including cleaning for refixing or removing to store. |
| 108 | M&L for 110 mm dia PVC (SWR)pipe singlesocketed (ISI marked) fixed fixed to wallwith mild steel clampscomplete all as specified and directed. |
| 109 | M&L PVC (SWR) 110mmbends any radiusequal complete all as specified and directed. |
| 110 | S & F 110 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door. |
| 111 | S&F75mm bore PVC soil waste pipepipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc including taking down of any type complete all as specifed and directed. |
| 112 | S & F75 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door. |
| 113 | M&L 75 mm,PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 114 | M&L 75 mm) PVC (SWR) multi floor trap with grating including jointing with solvent cementcomplete all as specified and directed. |
| 115 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 116 | M&L for Providing precast cement concrete 1:2:4, type B1(20 mm graded aggregate) set in CM 1:6, as in cover slabs (for manholes etc) with plain fair faces, all as spd.pd. |
| 117 | M&LProviding, cement concrete 1:2:4, type B0(12.50 mm graded aggregate)in lintels upto 1.5m clear span hand wash counter wuthout base , cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 118 | S& F readymade pulley operated clothes drying system incl of four aluminium pipes of 9 feet long each (4pipes)channel assembly locking system ropes and all fixing material complete all as specified and directed . Make Easy Dry or equivalent make aas approved by CE Southern command Pune |
| 119 | Exavating intrenches in Hard / dense soil n. exe 1.5 m wide and n. exe 1.5 m in depth, for foundation etc or for shafts, wells, cess pits, man holes, pier holes etc n exe 10 sq m on plan n exe 1.5 m depth and getting out complete all as specified and directed |
| 120 | M & L for cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation complete all as specified and directed. |
| 121 | S/F 200mm bore Reinforced concretepipes,class NP3, laidand jointed completewith collarscomplete all as specfied and directed. |
| 122 | M&L for concretebed in cement concrete 1:3:6 type C2to drain pipes of 200 mm boreincludingpacking under and haunching against the sides of pipes after they are laid and tested complete all as specfied and directed. |
| 123 | Returning, filling in Hard / dense soil , including spreading, levelling, watering and well raming in layer not exe 25cm complete as specified and directed. |
| 124 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed of material ourside MD landcomplete as specified and directed. |
| 125 | Cutting into existing man holes for connecting new drains of 200mm dia pipe and making good two pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 and finished and reforming benching as required complete all as specified and directed. |
| 126 | M&L for providing stages wise waterproofing treatment to sunken portion of toilets as under. Stage 1:Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debries outside MD land etc complete all as specified and directed.Stage 2:Providing15 mm thickplaster in CM 1:3 mixed with integral water proofing chemicalof STP Ltdin the proportion /quantity all as per manufactures instructions.Stage 3 : Primer - Mix TarfeltLM with water in ratio 1:1 @ 250 gms/sqm and apply the primer on the plaster surfaces Stage 4 :Application of 1 st coat of Tarfelt LM of STP Ltd without dilution with water@1kg/sqm by brushall as per manufactures instructions.Stage 5: Laying 50 GSM fyber glass cloth over the 1st coat while the coated surface is still tacky.Stage 6:After 6 to 7 hours interval apply second coat i.e final coat of Tarfelt LM without dilution with waterof STP Ltd by brush as per manufactures instructions.@1kg /SqmStage 7: Providing10mm thick protective plaster in CM 1:3 mixed with STP NO -1 @ 250ml/50kg cement all as manufactures instructions. |
| 127 | M&L for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed |
| 128 | S&F premoulded FRP Chajjas with 2 to 2.5 mm FRP thickness on both sides with manglore clay type finished with 150 mm drop on front, sides and 60 mm collar on back side includingincluding necessary scaffolding necessary fixtures complete all as directed. |
| 129 | M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed |
| 130 | M&L Cutting grooves in brick wall, 100 mm wide and 150 mm deep and shaping , fillingcement concrete 1:2:4 type B-lin cementmortar 1:3making good to facings where requiredcomplete all as specified and directed(Note :- Supply onlyShali Crete (Acrylic polymer Coating) water proofing shall be measured & paid separately). |
| 131 | S&F Mortice Door lock handle set 200 mm /6 leverlocking suitable for left and right handle door ,brass body6 lever for wooden door 2 in 1 pin or keycomplete all as specified and directed |
| 132 | Supply only Shali Crete (Acrylic polymer Coating) water proofing compound. |
| 133 | M&LDemolition of cement concrete any faceinternal /externalunreinforced of any type any level and at any position Ensure that structure is at least 3 days old, Bonding AgentBond coat with a mixing ratio of 1:2 (one part of ShaliCrete® and two parts of cement).The applied bonding agent should be in tacky condition before topping.Repair Mortar Bond coat with a mixing ratio of 1:2 (one part of ShaliCrete® and two parts of cement) including 10mm Repair Mortar with a mixing ratio of 1:2:4 (one part of ShaliCrete®, two parts of cement and five part of sand) applied in specified area.• After the application of Repair Mortar to keep the surface moist for 12 - 24 cement complete all as specified Note : Shali Crete (Acrylic polymer Coating) .a shall be measured & paid seperately.and including necessary scaffoldingcomplete all as specified and as directed. |
| 134 | M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc complete all as specified and directed. |
| 135 | M & L for post construction anti - termit treatment at points of contract of wood work using chemical emulision (in oilor kerosin based solution ) @ 0.5 liters per hole by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed. |
| 136 | M & L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors |
| 137 | M & LProviding and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 138 | SCHEDULE \"A\" PART I (E/M WORKS)Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for and directed. reuse refixing and making good distrubed surface of wall, floors etc all as specified |
| 139 | Taking down main switches from DBs with sheet metal enclosure 08/04 way SPN/TPN DBs etc all as specified and directed. |
| 140 | M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed |
| 141 | -ditto- all as per item No 140 above but for one 5 pin socket 5 Amps on same board complete all as specified and directed |
| 142 | -ditto- all as per item No 140 above but for one 5 pin socket outlet 05 Amp independent board complete all as specified and directed |
| 143 | M & L for point wiring complete with proper colour coding using 1100 volts grade, 2.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the Including PVC same in CM 1:3 to match with the existing surfaces and partly drawn in and casing caping fixed cn the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc. also inclduifng 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one 5Pin,6/16Amps, Socket outlet to common earth dolly all as specified and diretced for one 5Pin,6/16Amps, Socket outlet independent,complete all as specified and directed |
| 144 | Supply & fixing ceiling rose, surface bakelite 3 terminal complete all as specified. |
| 145 | Supply & fixing modular fan regulator,120W-2 module complete all as specified |
| 146 | Supply & fixing switch modular type 6 Amp single pole one way 230V complete all as specified. |
| 147 | Supply & fixing switch modular type 16 Amp single pole one way 230V complete all complete all as specified. |
| 148 | Supply & fixing socket modular type 6 Amp 2/3 pin single pole one way 230 V complete all as specified. |
| 149 | Supply & fixing socket modular type 16 Amp 2/3 pin single pole one way 230 V specified. |
| 150 | Supply & fixing Modular white cover plate with frame 8 Module complete all as specified. |
| 151 | Supply & fixing Modular white cover plate with frame 4 Module complete all as specified. |
| 152 | Supply & fixing Modular white cover plate with frame 3 Module complete all as |
| 153 | Supply & fixing modular Metal Flush box 8 Module complete all as specified. |
| 154 | Supply & fixing modular Metal Flush box 4 Module complete all as spécified. |
| 155 | Supply & fixing modular Metal Flush box 3 Module complete all as specified. |
| 156 | S&F in repairs LED Batten T-5,integrated sleek extruded LED channel with acrylic cover, with and including 20 Watt light and driver, prewired, provision of 0.5 Sqmın 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed. LED batten must have technical specification specified below: - 20 W Wattage, Rated input voltage-140 V AC-270 V AC, Driver efficiency- 88%, Lumens Efficiency-100lm/w, starting voltage 90V and THD <=20 Colour Rendering index (CRI) >80, Colour Temperature-6500K, Cool daylight Light Effect, No harmful radiations, In built surge protection-2.5 kV, Isolation-3.75 kV and Zero mercury content. Make- Havells/Philips/Bajaj/Wipro/Jaquar as approved by the GE. |
| 157 | Fixing only in repairs LED Batten T-5,integrated sleek extruded LED channel with acrylic cover, with and including 20 Watt light and driver, prewired, provision of 0.5 Sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed. |
| 158 | S&F LED Batten T-5,integrated sleek extruded LED channel with acrylic cover, with and including 10 Watt light and driver, prewired, provision of 0.5 Sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed. LED batten must have technical specification specified below: - 10 W Wattage, Rated input voltage-140 V AC-270 V AC, Driver efficiency- 88%, Lumens Efficiency-100lm/w, starting voltage 90V and THD <=20 Colour Rendering index (CRI) >80, Colour Temperature-6500K, Cool daylight Light Effect, No harmful radiations, In built surge protection-2.5 kV, Isolation-3.75 kV and Zero mercury content. Make- Havells/Philips/Bajaj/Wipro/Jaquar as approved by the GE. |
| 159 | Fixing only in repairs LED Batten T-5,integrated sleek extruded LED channel with acrylic cover, with and including 10 Watt light and driver, prewired, provision of 0.5 Sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed. |
| 160 | Taking down exhaust fan 300 mm sweep, 1200 rpm, 230V and Refixing same exhaust fan after building repairs complete with louvers, Steel body, bolts, nuts, washers, suitably embedded in window with provisioning of flexible three core wire for electrical connections from ceiling rose to fan all as specified and directed (fcr bathroom)Note: Contractor shall deposit Ex fan in MES store till refixing. |
| 161 | Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing, oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces, complete all as specified and directed. |
| 162 | Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces. |
| 163 | M&L for sub main wiring complete two run of size 1.5 sqmm PVC insulated, unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as specified and directed. continous earth wire connected to common earth dolly and mains, complete all as specified and directed.Note: Three run 1.5 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as \"one unit\"length. |
| 164 | M&L for sub main wiring complete two run of size 2.5 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc also including one run of 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed.Note: Three run 2.5 Sqmm PVC cable and one run of Casing Caping & conduit wil! be measured as \"one unit\"length. |
| 165 | 29 M&L for sub main wiring complete Two run of size 06 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn partly in and including PVC conduit concealed in walls etc including including PVC casing cutting chases and making good the existing surfaces and partly drawn in and caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 06 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected tocommon earth dolly and mains, complete all as specified and directed.(TPN DB to Room DB)Note: Three run 6 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as \"one unit\"length. |
| 166 | M&L for sub main wiring complete Four run of size 16 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn partly in and including PVC conduit concealed in walls etc including including PVC casing caping cutting chases and making good the existing surfaces and partly drawn in and fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 16 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected tocommon earth dolly and mains, complete all as specified and directed. (Main Panel to TPN DB)Note: Five run 16 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as \"one unit\" length. |
| 167 | Supply & fix in repairs sheet metal enclosure powder coated for MCB DB SPN 12 way double door with din rail and bus bar including making good to the disurbed surface matching with the existing complete alla s specified and directed. |
| 168 | S & F in repairs Vertical TPN DB, 415 volts, 4 way double door, With provision for TP 63A MCCB as incomer and SP / TP MCBs as outgoing With neutral bars & earth bars complete all as specified and directed including making good to the disurbed surface matching with the existing also fixing MCB and MCCB to the panel complete all as specified and directed. |
| 169 | Supply and fix in repairs MCCB 63 Amps 4 Pole, with breaking capacity 16 KA complete all as specified and directed. |
| 170 | Supply and fix in repairs MCB SPN 240 volts 32 Amps breaking capacity 10 KA \"B\" Series rating complete all as specified and directed. |
| 171 | Supply and fix in repairs MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA \"B\" Series rating complete all as specified and directed. |
| 172 | Taking down unserviceable building security light fitting and Supply and fixing ir, repairs pressure die cast housing with epoxy power coated dark graphite grey colour finish. Prismatic polycarbonate cover with individual LED lenses 35 watt, AC 240 Volts 50 HZ,\"IP66 protection, PF>0.95, LED light luminous efficiency shall not be less than 90 LumensWatt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking\"complete all as specified. Make: Philips/Havells/Osram |
| 173 | Supply and fix in repairs pipe bracket made out of 32 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to required shape and fixed on pole including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed. |
| 174 | Material and labour for earthing complete with GI earth plate electrode 600x600x6 .mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below! ground lavel) with top edge of the plate not less than 1.5mtr below normal. ground lavel connected to Gl earth strip 25X4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and Cl cover fullel with watering pipe, wire mess and copper lugs etc Gl protection pipe 40 mm dia medium grade including testing on completion all as specified and directed. |
| 175 | Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type,platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS: 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS: 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.Location: P/106 Wing -01 & 02Note: The contractor duly shall submit the Manufacturer\"S Design and drawings of LT panels for approval of GE before placing the order. The scope of work also comprising of the following:- BUS BAR CHAMBER :-(a) 250 Amp 4 Strips, Aluminium conductor, with color coded (R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER(i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three), (iii) Protection MCB 6 A SP C Series- 1 Set. (Set oftype three). (iv) CT 200/5A Set of -03 Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.INCOMING SUPPLY:-(i) MCCB 160 Amps breaking capacity 16 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release with adjustable overload.OUTGOING SUPPLY:-(i) MCCB 100 Amps 16 KA, 4 Pole with Fixed thermal & magnetic release 415 volts, 50Hz 04 Nos.(ii) MCB SPN 40 Amps 10 KA,50Hz = 02 Nos.Note: All MCCB\"S shall conform to IS: 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes |
| 176 | Taking down carefully 12 KW Heat pump water Heater system from the Existing Building(P-106) complete including Connected Items such as Power Cables, PVC Conduits of any size,Water PVC pipes and fittings of any size etc, removing materials from site And Reinstallation, Testing and Comissioning of Above Removed 12 KW Heat pump water Heater system on the roof top of the same Building after done the Roof treatement by B & R at INS Hamla all as specified and directed. Note :-(a) Heater in safe manner Note: (a) The Contractor shall make own Arrangements for shifting and kept Heat pump water(b) The Contractor Shall Responsible for Replacement of any Damages to Heat Pump and Connected Items During From Removal To Reinstallation Process Complete all as specified and Directed by the Engineer-in-Charge.(c) The Contractor Shall Execute and Comissioning of above Heat pump water Heater system work with Authorised Skilled Workers only, |
| 177 | M&L in repairs sub main wiring complete Four run of size 06 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn partly in and including PVC conduit/concealed in walls etc including including PVC cutting chases and making good the existing surfaces and partly drawn in and casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 06 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed.Note: Five run 06 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as \"one unit\"length. |
| 178 | 3 Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers including refilling with good earth as specified and electrode connections by using galvanised iron strip of size 25x4 mm by means of bolts, nuts, check nuts and washers made of GI and provision of GI pipe medium grade 40 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, Cl pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-1 2009. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail