| 1 | Demolition of brick/stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, ashlars masonry etc, and removal complete all as specified & directed by Engr-in-Charge. |
| 2 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. |
| 4 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thickness(below or above ground level) & removal of rubbish material complete all as specified & directed. |
| 5 | M&L for PCC (1:2:4) type B-0 (using12.5mm graded stone aggregate), 25mm thick, as in floor complete all as specified & directed by Engr-in-Charge. |
| 6 | M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. |
| 7 | All as per Srl item No. 6 here-in-before but on vertical surface such as skirting, dado over 10mm thick cement sand plaster (1:4) etc complete all as specified and directed by Engineer - in - Charge. |
| 8 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified & directed. |
| 9 | M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types andover screed bed 20 mm thick CM1:6 cement concrete complete all as specified & directed. |
| 10 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection /path finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified & directed. |
| 12 | M&L for rendering 10mm thick in CM 1:6 onbrick work / stone or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement complete all as specified & directed. |
| 13 | M&L for rendering 15mm thick in CM 1:4 on brick work /stone or concrete wall surfacesfair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound (water proof compound paid seperatly) complete all as specified & directed. |
| 14 | M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified & directed. |
| 15 | M&L for Rough cast plaster on exterior wallsapplying the under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed. |
| 16 | M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper over 2mm thick wall care putty to prepare the surface even and smooth complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for preparation of newly plastered surfaces of wall and applyingthree coats of white wash complete all as specified & directed. |
| 18 | Material and labour for prepration over new surface and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thickwall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces & applyingthreecoat of white wash on ceiling complete all as specified & directed. |
| 20 | Material and labour for complete removal of existing treatmentfrom stone wall /plastered wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkali and fungal resistance, dirt resistance, exterior emulsion paintof required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed. |
| 21 | M&L for complete removal of existing treatmentof old surfaces of wall includingcornices, pilasters and other wall features etc by washing, rubbing down and applying two coat of oil distemper over 1mm thick wall care putty complete all as specified and as directed. |
| 22 | Demolition Mud in roofs, any thicknes, including plastering, existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified& directed |
| 23 | M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & directed. |
| 24 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in slope over roof complete all as specified & directed. |
| 25 | M&L for screed bed laid 15mm thick in CM 1:4with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified& directed by Engr-in-Charge. |
| 26 | Supply only Integral liquid waterproofing compound complete all as specified & directed. |
| 27 | M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. mincluding cleaning surfacesover bituminious primer complete all as specified & directed. |
| 28 | M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 29 | M&L 50mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4,complete all as specified & directed. |
| 30 | Cutting holes in stone walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc half brick wall complete all as specified & directed. |
| 31 | Taking down chowkatts or framesn exc 1.5 sqm each complete all as specified & directed. |
| 32 | Taking down chowkatts or framesexc 1.5 sqm but n exc 4 sq m each complete all as specified & directed. |
| 33 | Taking down Shutters of any description n exc 1sqm each complete all as specified & directed. |
| 34 | Dismantling wrought iron or mild steel work of any description not otherwise provided for any work complete all as specified and directed. |
| 35 | M&L for Mild steel angle iron door frame 40mmx40mmx5mm conforming to Fe 410-0 (Gde-E-250) incl 12mm dia deformed bars for strengthing at bottom of chowkhats incl cutting floor at bottom to accommodated strengthing bars & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specified& directed. |
| 36 | S&F 35mm thick 2nd class hard wood factory made panelled door shutter(two panel) with lock rail and panelof 9mmBWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified & directed. |
| 37 | S&F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified& directed. |
| 38 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified& directed. |
| 39 | S&F Butt hinges 100mm long medium weight, colled rolled mild steel complete all as specified & directed. |
| 40 | S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixedcomplete all as specified & directed. |
| 41 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified & directed. |
| 42 | S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified & directed. |
| 43 | S & Fixed 300mm Helical/rat tail door Spring 300mm size with MS sheet wing pattern including roller plate complete as directed. |
| 44 | S&F in repair stainless steel drapery rod 25mm dia (in lengths directed) of approved colour with and including decorative bowel at both ends and pair of power coated stainlesssteel brackets fixed at both ends with pvc Rawl plug and steel screwed on walls/beamcomplete all as specified & directed. |
| 45 | S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed. |
| 46 | S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. |
| 47 | S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. |
| 48 | S&F for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium grill of approved pattern for windows/ ventilators/doors complete all as specified and directed. |
| 49 | Supply only sheet glass ordinary quality,in squares n. exc. 0.5 SQM each 4.80 mm thick complete all as specified & directed. |
| 50 | Cutting holes into or through brick but in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of limeEx 150 sq. cm but n exc 400 sq. Cm (not excluding 25CM depth) for cooler stand complete all as specified & directed. |
| 51 | S & F in repair Plain 4mm mild steel wire in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc complete all as specified & directed. |
| 52 | S&Fin repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 53 | M&L writing letters or figures(Block,roman,Italic or Indian letter n.exc 30cm high) complete complete all as specified & directed. |
| 54 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified & directed. |
| 55 | S&F MS steel work in tubulartrusses and tubular posts, purline, rafter including special shaped washers etc., complete using but welded.RHS/SHSconfirming to IS 4923 : 1997 complete all as specified & directed |
| 56 | Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified & directed. |
| 57 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etccomplete all as specified & directed |
| 58 | S&F M.S. frame work such as grills, gratings, angle frame etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stands and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed. |
| 59 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 60 | M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girthand applying one coat of synthetic enamel paint complete all as specified & directed. |
| 61 | Demolition of cement/lime concrete (un-reinforced) in ground floor and paving exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as specified& directed. |
| 62 | Dismanlting of kerb stoneincluding cement bedding & removed off rubble complete all as specified & directed. |
| 63 | M&Lfor 75 mm thick PCC 1:4:8 type D -2 using 40 mm graded aggregate as in sub base of path/hardstandingcomplete all as specified & directed. |
| 64 | M&L 60mm thick machine pressed precast conctete coloured interlocking paver block with grey cement andpigment any shape and size confirming to IS 15658-2006 , M-35 Grade and over 25mm thick sandcomplete all as specified and as directed. |
| 65 | M&L 25mm thick Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directedby Engr-in-Charge. |
| 66 | M&L Plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) set in cement mortar 1:4 as in kerb blocks with plain fair faces including chamfered weathering throating etc complete all as specified& directed by Engr-in-Charge. |
| 67 | M & L for preparation of kerb stone, new un-treated concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint in black and white colour over a coat of primer complete all as specified and directed. |
| 68 | M&L PCC 1:3:6, type C-2 (using 40mm graded aggregate) as in surface channel, and drain etc complete all as specified & directed. |
| 69 | M&L for cement concrete type B-1,1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 70 | Extra for forming fair finished to drain or channel 30 cm innergirth in cement concrete, using extra cement including form, moulds etc.complete all as specified and as directed. |
| 71 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 72 | M&L for point wiring for One light/fan point controlled by one switch 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistrandedcopper conductor conforming to IS:694:1990 with ISI marking in and including concealed PVC conduit of suitable size with all accessoriesin wall/ceiling /floor/roofetc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earthwire connected to common earth dolly complete all as specified and directed. |
| 73 | All as per srl item No 72.00 but for One 3 pin 5 amp socket outlet on independent board |
| 74 | All as per srl item No 72.00 but for one three pin socket outlet 5 amps on the same board |
| 75 | M&L for point wiring complete for one socket outlet 15 amps on an independent board with FRLS, PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 including concealed PVC conduit of suitable size, pressed steelterminal boxes not less than 2 mm thick of required size (factory made) includingpainting terminal boxes inside and outside with two coats of synthetic enamel paint over a coat of red oxide primer and with top cover 3mm thick of plastic laminated sheets of required colour, complete with all accessories and all as specified including FRLS PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete and controlled by one 15 Amp switch complete all as specified and directed. |
| 76 | M&L for point wiring complete for one socket outlet 15 amps on an independent board with FRLS, PVC insulated and unsheathed cable 4 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 including concealed PVC conduit of suitable size pressed steelterminal boxes not less than 2 mm thick of required size (factory made) includingpainting terminal boxes inside and outside with two coats of synthetic enamel paint over a coat of red oxide primer and with top cover 3mm thick of plastic laminated sheets of required colour, complete with all accessories and all as specified including FRLS PVC insulated and unsheathed cable 4 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete and controlled by one 15 Amp switch complete all as specified and directed. |
| 77 | Supply and fixceiling fan regulator electronic step type 230 Volts single phase complete all as specified and directed. |
| 78 | Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surface conduit and offering credit as per schedule of credit all as directed complete all as specified and directed.Note : Any runs of cable and earthwire will be measured as one unit length. |
| 79 | M&L for submain wiring with 4 run of 6 sqmm single core copper conductor PVC insulated cable and 1 run of 6 sqmm single core copper conductor insulated cable as earthing lead drawn through PVC conduit complete all as specified and directed. Note:4 run of 6 sqmm cable and 1 run of 6 sqmm cable together will be measured as one unit length. |
| 80 | Supply and fixin repair switch Piano 6 Amps one way flush type,make, ISI marked,complete all as specified and directed. |
| 81 | Supply and fix in repair switchsocket combination outlet 3 pin 6/16 Amps flush type multipurpose with fuse & neon indicator make ISI marked, complete all as specified and directed. |
| 82 | Supply & Fix in repair ceiling rose surface bakelite 65 x 50 mm three terminal, complete all as specified and directed. |
| 83 | Supply & fix in repair LED batten tube light along with fixture, 1x20 W AC ,Energy saving, LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Halonix, Havells, philips, wipro or equivalent |
| 84 | M&L for rewinding ceiling fan 1200/1400mm sweep with super enamalled copper wire of exisiting gauge including insulation material varnishing and drying complete all as specified and directed. |
| 85 | S&F in repairs MCB DB TPN 8 Way double door 415 Volts complete all as specified and directed. |
| 86 | S&F in repairs MCB DB SPN 8 Way double door 240 Volts with 200 amps rated bus bar complete all as specified and directed. |
| 87 | Supply & fix in repairs MCB TPN 63 amp, 230 Volts, Single phase, 10 KA Capacity complete all as specified and directed. |
| 88 | Supply & fix in repairs MCB SPN 40 Amp, 230 Volts, Single phase, 10 KA Capacity complete all as specified and directed. |
| 89 | Supply & fix in repairs MCB SP, 6 to 40 Amps, 230 Volts, Single phase, 10 KA Capacity complete all as specified and directed. |
| 90 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB-1 chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing and taking down of existing earthing complete all as specified & directed. |
| 91 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm3.5 core laid in trenches/ ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down of existing cable complete all as specified and directed. |
| 92 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 93 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 94 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed. |
| 95 | M&L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection including taking down old unserviceable bricks complete all as specified & directed. |
| 96 | M&L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed.Note :- Thickness after punning shall be considered for payment. |