| 1 | Roughning for old concrete surface/floor by picking, weeping clean and washing with down with water to remove dust/any existing roof treatment including brushing neat cement slurry with 3.00 Kg of cement per sqm etc. |
| 2 | M&L for PCC (1:2:4) type B-0 as roof padding concrete to bring the extg slab in slope of 1:40 complete all as specified and directed. |
| 3 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20kg per sqm incl cleaning surfaces complete all as specified and directed. |
| 4 | M&L for fixing APP based polymeric membrane minimum weighing 3.50kg/sqm and min 3mm thick reinfirced with polyster noin wove faric (wt not less than 150gms/sqm) land on primed surface by forced torch application complete all as specified and directed. |
| 5 | M&L PCC (1;2:4) type B-0 using 12.5mm graded stone agregete as in sides of rounded or chamfered on edges of sunken floor/parapet walls/paver tiles etc ccomplete all as specified and directed. |
| 6 | M & L for applying two coat of elastomeric paint, weather resistant, waterproofing protection having long lasting finish including preparation of surfaces etc complete all as specified and directed. |
| 7 | Disconnecting existing PVC water storage tanks of capacity exc 500 ltrs & n exc 1000 ltrs, setting aside (or lowering if required) for laying of APP memberane or repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed. |
| 8 | Demolition of cement Concrete(unreinforced)of any description and in any position not otherwise specifically provided for(below or above ground level) or as in sunken complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:3 finished even and smooth without using extra cement with WPC 3% by wt of cementNote:-WPC measured and paid separatly complete all as specified and directed. |
| 10 | M&L for cement concrete type D- 2, (1:4:8) (using 40 mm graded stoneaggregate) as in foundation filling & mass concrete as in sunken floor complete all as specified and directed. |
| 11 | M&L for 25mm thick cement concrete type B-1, (1:2:4) using 20mm graded aggregate as in sub floor complete all as specified and directed. |
| 12 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 13 | M&L Brick work using old size bricks with sub class \"B\" bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 14 | M&L Brick workexcept Bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 15 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 16 | M&L for rendering 10mmthick in ceiling on brick work or concrete surfaces in CM (1:3), finished even and smooth without using extra cement all as specified and directed. |
| 17 | M&L for rendering 10mm thick internal wall surfaces on fair faces of brick work or concrete in CM (1:6) complete all as specified and directed. |
| 18 | M&L10mm thick rendering in cement mortar (1:4) on RCC chajjas, facia , roof projections, parapet walls etc rendering is to be even and smooth with out using extra cement(upto 3 storey bldg)complete all as specified and directed |
| 19 | M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC 3% by wt of cement.Note:-WPC measured and paid separatly. Plaster will be executed upto 15 m height and no any extra cost will be considered complete all as specified and directed. |
| 20 | Supply Only integral water proofing compound |
| 21 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemperas per manufacturer instruction white or tinted complete all as specified and directed. |
| 22 | M & L for preparation of new plastered/decoarated wall surfaces and applying two coats of water proof cement base paint complete all as specified and directed. |
| 23 | M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. |
| 24 | M & L for applying a thin layer of 0.50mm thick white wall care putty over newly plastered surface toprepare the surface even and smooth complete all as specified and directed. |
| 25 | M&L for damproofing to wall/chajja with two component Acrylic polymer cementitious water proof elastomeric coating four grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joint of fibremesh not less than 100mm,then finally apply second layer mix by brush to entire surfaceof container covering 0.6-0.75Sqm/kgat 1mm thick in two coat depending upon the level of substrate and curing it for minimum 3 days.Note: Quated rate shall be deemed to be inclusive of materials and all labours,tools and plants,scaffolding and working upto height 10m etc. complete all as specified and directed. |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 27 | M & L forCement concretetiles 20cm x 20cmx 20mm thick,ma c h i n epressed; setjointed andpointed in neatcement slurry infloors/roof top surface, and cutand polished laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6set,complete all as specified and directed. |
| 28 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 29 | M & L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded stone aggregate) in chajjas etc and the like complete all as specified and directed. |
| 30 | M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface of concrete complete all as specified and directed. |
| 31 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 32 | Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding, any type, any location/height (i.e roof parapet walls near pipes etc) and applying acid after removing roots for preventing the regrowthing and making good the disturbed portion using PCC 1:2:4 type B-0 and plaster in CM 1:3 (size of disturbed portion 150 x 150 x 200 mm) complete all as specified and directed. |
| 33 | Demolition of cement concrete(reinforced) for roof top RCC water tanks in any description in any position not otherwise specially provided disposal off from the premises at distance of not exc . 1 Kmcomplete all as specified and directed. |
| 34 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 35 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 36 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed |
| 37 | S&F PVC (SWR) bends ISI marked any radius of 110 mm borewithaccess door complete all as specified and directed. |
| 38 | S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed. |
| 39 | S & F of PVC (SWR) junction single, (Single T) 110 mm bore equal or unequal with acess door complete all as specified and directed. |
| 40 | S & F of PVC (SWR) junction single, (Single T) 75 mm bore equal or unequal with acess door complete all as specified and directed. |
| 41 | S & F 110mm bore PVC (SWR) vent cowl with rubber ring joints,fixed to pipes all as specified and as directed. |
| 42 | Taking down chowkhats or frames exc 1.5 Sqm but exc 4.0 Sqm (without taking shutters from the frame). |
| 43 | Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame). |
| 44 | Taking down Shutter of any description area exc. 1 sqm and not exc . 2 sqmeach |
| 45 | M&L for second class hardwood plain, solid, straight chowkat and frame, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed. |
| 46 | M&L for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed. |
| 47 | M&L for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed. |
| 48 | M&L for providing PCC 1:3:6, type C-0 (using 12.50 mm graded stone aggregate) as in filling of pressed steel door frame and holdfasts including necessary formwork etc complete all as specified and directed. |
| 49 | M&Lfor 30mm thicksecond class hardwood glazed and skelton doorshutters (Three panels) open rebated and prepared to receive glass / gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sash bars size of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) complete all as specified and directed. |
| 50 | M&L for 30 mm thick Flush shutters, solid core construction, with block board core plywood face panels on both side, commercial type on both sidesincluding 5 mm thick edging/beading on exposed to view on sides & top complete all as specified and directed. |
| 51 | S & F solid PVC frame of size 50 mm x 47 mm made out of 5 mm single side prelam PVC sheet & edges will be printed to match with prelam sheet rein forced with MS square tube etc complete all as specified and directed.. |
| 52 | S&F factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame complete all as specified and directed. |
| 53 | S&F 100mm long butt hinges SS medium weight cold rolledand fixed |
| 54 | S&F 150 mm long brass barrel tower bolt with cast or sheet barreland rolled or cast bolts and fixed complete all as specified and directed. |
| 55 | S&F 150mm long Brass handles, cast type, polished bright complete. |
| 56 | S&F 100 mm long aluminium anodised barrel tower bolt and 12 mm dia fixed |
| 57 | S&F 150mm long aluminium anodised handle cast type and fixed D Type |
| 58 | S&Falluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 300 mm long complete all as specified. |
| 59 | S & F in repair 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 60 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane(to be fixed upto four storey of bldgs) complete all as specified and directed. |
| 61 | S & F galvanised stainless steel wire cloth0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples (to be fixed upto four storey of bldgs) complete all as specified and directed. |
| 62 | S&Faluminum frame powder coated for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed. |
| 63 | S&Fany colour, aluminum window and ventilator shutters, powder coated sliding/side hung type with sash bars, aluminium section weighing not less than 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 64 | Dismantling structural steel work including doors, gates, grills but excluding framed truss etc complete all as specified and directed. |
| 65 | S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 66 | M&L two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincl preparation of surfaces complete all as specified and directed. |
| 67 | S&F in repair aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width andweight between 61 to 80 Kg complete all as specified as directed. |
| 68 | M & L for 0.9mm thick decorative laminate(mica) type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions complete all as specified and directed. |
| 69 | M&L for 18 mm thick for block boards, grade 2 quality, interior grade, commercial type, fixedwith screws to timber frame-work/Walls complete all as specified and directed. |
| 70 | M&L for 4 mm thick for Plywood, grade BWR, type BB,fixed with screws /Walls/chowkhats complete all as specified and directed. |
| 71 | S & F of 30 mm wide flap when open, mild steel bright finish or electro galvanised continuous (Piano) hingecomplete all as specified and directed. |
| 72 | S&F magnetic catcher to be used in cabinets as complete all as specified and directed. |
| 73 | S&F 100mm long Brass handles, cast type, polished bright complete all as specified and directed. |
| 74 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed. |
| 75 | M & L for anodised aluminium snap grid frame work of size 600mm X 600mm for false ceiling incl hanging toplastered surfaces/iron framework using suspenders et complete all as specified and as directed. |
| 76 | S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 77 | S&F in repairs4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 78 | S & F in replacement LED lights fitting 1x 20W 220V, LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements,complete all as specified and as directed. |