| 1 | Demolition of brickwork masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all specified and directed by E/I |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of Soft/loose soil complete all specified and directed. |
| 3 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick of Soft/loose soil complete all specified and directed. |
| 4 | M&L for earth filling backside wall along with flooring including spreading and levelling including watering well raming etc. in layer and exc 25 cm thick and rough excavated material exc. 1.50 km but n exc. 5km and depositing where directed. |
| 5 | M&L for anti-termite treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I |
| 6 | M&L for anti-termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all specified and directed by E/I |
| 7 | M&L for anti-termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfacecomplete all specified and directed by E/I |
| 8 | M&L for anti-termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface areacomplete all specified and directed by E/I |
| 9 | M & L Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) |
| 10 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in foundation / footing, plinth beam etc. excluding steel reinforcement and formwork complete all specified and directed. |
| 11 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves excluding steel reinforcement and formwork complete all specified and directed. |
| 12 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed inBeams, cantilevers, bressummers, lintels over 1.5m span excluding steel reinforcement and formwork complete all specified and directed. |
| 13 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed inColumns, pillars, piers, posts and struts excluding steel reinforcement and formwork complete all specified and directed. |
| 14 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed inChajjas excluding steel reinforcement and formwork complete all specified and directed. |
| 15 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete allspecified and directed |
| 16 | M&L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsas in reinforcement complete allspecified and directed. |
| 17 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished surface fair and even complete allspecified and directed. |
| 18 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished surface fair and even complete all specified and directed. |
| 19 | M&L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) finished surface fair and even complete all specified and directed. |
| 20 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished surface fair and even complete allspecified and directed. |
| 21 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. finished surface fair and even complete allspecified and directed. |
| 22 | M&L for Formwork to Formwork to chullah hoods, chajjas, troughs and similar items including edges complete allspecified and directed. |
| 23 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:6 complete all specified and directed. |
| 24 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan to any radius built inhalf brick thick walls built in cement motar 1:4 complete all specified and directed. |
| 25 | M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on surface complete allspecified and directed. |
| 26 | M&L for Screed bed or bedding layer of mortar 15 mm thickCement plasterwith 1:4 mortar for laying floor finishes complete all specified and directed. |
| 27 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed inwhite or coloured cement to match complete all specified and directed. |
| 28 | M & L of Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete complete all specified and directed. |
| 29 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of splain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing withboth side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges complete all specified and directed. |
| 30 | S&F of Extruded aluminium alloy handles, fabricated type, anodised with size ofhandle 150mm long complete all specified and directed. |
| 31 | S&F 200 mm long Aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed. |
| 32 | S&F 250mm long aluminum alloy, anodised sliding bolt with hasp stable bolt type stove enameled black, with bright bolt not less than 12mm dia and including a minimum 06 Nos bolts and nutls. Complete all as specified and directed. |
| 33 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised. |
| 34 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing with single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet completeall specified and directed by E/I. |
| 35 | M&L two coat oil bound distemper andpreparation of newly plastered surface of wall for internal side ceiling complete all specified and directed by E/I. MAKE- APEX |
| 36 | M&L for cement paint i.e.two coat of exterior emulson paint andpreparation of newly plastered surface outside complete all specified and directed by E/I. |
| 37 | M&L for 3mm thick wall care putty on wall |
| 38 | M&L for Preparation of New steel and iron surface of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over coat of red oxide primercomplete all specified and directed. |
| 39 | S&F of Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 40 | S&F ofGlazed ceramic coloured tiles tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 41 | M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 1.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make ofhavells,fenolex, pllaza |
| 42 | M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 2.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make ofhavells,fenolex, pllaza |
| 43 | Supply and fixing modular switch one way 6 Amps complete all as specified and directed. |
| 44 | Supply and fixing switchsocket outlet 3 pin 5 Amps flush type complete all as specified and directed. |
| 45 | Supply and fixing switch socket outlet combined multipurpose 6 pin, 16 Amps 3 module complete all as specified and directed. |
| 46 | S&F lamp holder insulated body with back plate 5 Amps suitable for batten fittings (angle plain) complete all as specified and directed. |
| 47 | S&F Single pole & neutral1, 4 way DB enclose double door complete all as specified and directed. MCB 5 to 30 Amp single phase 12 Nos DP single phase 40Amp 3 Nos- make- HAVELLS |
| 48 | Supply and fixing ceiling fan regulator electronic type 5 stage speed variation ISI marked complete all as specified and directed.. |
| 49 | Supply & Fixing single pole MCB 10 to 40 amp. complete all as specified and directed. |
| 50 | Supply & Fixing isolator Double pole 40 amp.complete all as specified and directed. |
| 51 | Supplying and fixing 1100 volts grade heavy duty, 10 Sqmm 2 core cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mater aprt including 4mm dia, GI suspensions wire, two single core cable falt or circular complete all as specified and directed. |
| 52 | S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by E/I |
| 53 | S&F of110mm dia PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed by E/I |
| 54 | S&F of75mm dia PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed by E/I |
| 55 | S&F of 110mm dia PVC (SWR)bendsany radius |
| 56 | S&F of 75mm dia PVC (SWR)bendsany radius |
| 57 | S&F of PVC (SWR) vent cowl bore in 110mm |
| 58 | S&F of 110mm bore in PVC (SWR) couplers |
| 59 | S&F of 75mm bore in PVC (SWR) couplers |
| 60 | S&F of 110mm PVC (SWR) WC connector with lip ring |
| 61 | S&F of 110mm PVC (SWR) \"P’ trap |
| 62 | S&F of Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) |
| 63 | S&F of PVC (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm dia |
| 64 | S&Fofsinks with drainage board made of stainless steel lmm thick kitchen or laboratorywith plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed by E/I |
| 65 | S&Fof Vitreous China, semi-pedestal pattern (Anglo-Indian Type) including 10 litres, cast iron, valveless. syphonic action type, flushing cistern, high level, with inlet, ball valve, float, chain and pull, and brackets complete all as specified and directed by E/I |
| 66 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 67 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 68 | Supplying and laying of 25mm dia CPVC pipes CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified. |
| 69 | S&Fof 500 liter Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by E/I |
| 70 | S&Fof 15mm dia Plug type bib taps, cast iron, screwed for iron pipe and fixedcomplete all as specified and directed by E/I . |
| 71 | S&Fof 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 72 | S&Fof 25mm dia Stop valves, cast copper alloy, screweddown, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixedcomplete all as specified and directed by E/I . |
| 73 | S&Fof 15mm diaAngle stop valve of PTMTanycolour high pressure screwed for iron pipe and fixed with Minimum weight 15mm-90gms) complete all as specified and directed by E/I . |
| 74 | S&Fof Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour with Minimum weight 40gms complete all as specified and directed by E/I . |
| 75 | S&Fof Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 300gms complete all as specified and directed by E/I . |
| 76 | S&Fof Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 105gms complete all as specified and directed by E/I . |
| 77 | M & L of100mm with Cement concrete 1:3:6 type C-2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed by E/I . |
| 78 | S&F ofprecast cement concrete Type B1 1:2:4(20mm gradedaggregate) cover slabs (for man holes etc.) jointed in cement mortar 1:6 etc . complete in all respect as specified. |
| 79 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Soft/loose soil. |
| 80 | Supply & Spreading Hardcore Broken stone orboulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface complete in all respect as specified |
| 81 | M&L for 75 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for c.c. flooring complete all specified and directed. |
| 82 | 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 83 | Providing and laying at or near ground levelfactory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening hereverrequired complete. |
| 84 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 85 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length. |
| 86 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion elded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). |
| 87 | Three track three panels sliding window including grill, two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 88 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board |
| 89 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 90 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 andapproved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mmto 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-chargeover 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |