| 1 | Hacking of CC flooring including cleaning fo surface etc. complete as per direction of Engineer-in-charge. |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead.Of area 3 sq. metres and below |
| 3 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 6 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Old work (one or more coats) |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade.New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 8 | Applying priming coats with primer of approved brand and manufacture having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50grams/litre. |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 10 | Providing and laying polished granite stone flooring in required design and pattern, in linear as well as curvilinear portion of building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thickness base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by Engineer-in-charge. Polished Granite stone slab of colour Black, cherry/ruby red or equivalent. |
| 11 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size.Size of Tile 600 x 600 mm |
| 12 | Providing and layingvitrified floor tiles polished and finished in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colour and shades, in skirting, riser of steps over 12 mm thick bed of cement mortar 1:3 Kg/sqm including grouting the joint with white cement & materials pigment etc complete. Size of Tile 600 x 600 mm |
| 13 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately).Kiln seasoned and chemically treated hollock wood. 30 mm thick shutters |
| 14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 15 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 16 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : (copper oxidized as per IS: 1378).250x16 mm |
| 17 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (copper oxidized as per IS: 1378).250x10 mm |
| 18 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (copper oxidized as per IS: 1378).125 mm |
| 19 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm |
| 20 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-charge. |
| 21 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 23 | Providing and fixing white vitreous china padestal for wash Basin completely recessed at the back for the reception of pipes and fitting |
| 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 25 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the4 manuvacturer ), of approved make, in all colours, shades exceptburgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cemednt : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per4 sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 27 | Dismantling15 to 40 mm dia G.I. Pipe including stacking of dismantled pipes (within 50 metres lead) as per directions of Engineer-in-charge. (a) Internal work-Exposed on wall |
| 28 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge : 20 mm nominal dia pipes. |
| 29 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge : 15 mm nominal dia pipes. |
| 30 | Providing and fixing C.P. Brass Bib Cock of approved quality conforming to IS : 8931 : 15 mm nominal bore. |
| 31 | Providing and fixing C.P. Brass angle valve for basin mixer and geyser point of approved quality conforming to IS : 8931 : 15 mm nominal bore. |
| 32 | Providing and fixing unplasticised PVC connection pipe with brass union 45 cm length : 15 mm nominal bore |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level 1:4:8 ( 1 Cement : 4 Sand (Zone-III) direved from natural sources : 8 graded stone aggrgate 40 mm nominal size derived from natural sources) |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement: 2 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | Grading roof for water proofing treatment with cement concrete 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded stone aggregate 20 mm nominal size). |
| 36 | 12mm Cement plaster finished with a floating coat of neat cement of mix 1:4 (1Cement : 4 fine sand). |
| 37 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 38 | Taking out existing wooden door shutter, repair by cutting, painting etc, and refixing of repaired doorshutters toexisting door frames, including replacement of hinges with screws, etc. as requied, all complete as per the rorection of the Engineer -In-Charge. |
| 39 | Providing and fixingaluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 40 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 41 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 42 | Providing & fixing fly proof wire gauze to window, clarestory window & doors with M.S. Flat 15x3 mm and nut & bolt complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperature on both sides |
| 43 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium |
| 44 | Providing and fixing PTMT towel rail complete with brackets fixing to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm 78 mm wide and effective height of 88 mm, weighing not les than 170 gms. |
| 45 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 46 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 47 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 48 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) |
| 49 | Dismantling C.I. or asbestos rain water pipe with fittings and camps including stacking the material with 50 meters lead 100 mm dia pipe |
| 50 | Providing and fixing on wall face unplasticised - PVCrain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single sockated pipes 110 mm dia |
| 51 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Tee with door 110x110x110 mm dia |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler110 mm dia |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain), 110 mm Shoe |
| 54 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete. 110 mm |
| 55 | Providing and fixing Stainless Steel A ISI 304 (18/8) Kitchen sink as per IS : 13983 with C. I. brackets andstainless steel plug 40 mm , including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drainage board 470x420 mm bowl deppth 178mm. |
| 56 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead |
| 57 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenchesor drains(not exceeding 1.5 m in width or 10 sqm on plan), including dressing ofsidesandrammingofbottoms,liftupto1.5m,including getting out theexcavatedsoiland disposalofsurplusexcavated soilasdirected,withalllead&liftasperthedirectionofEngineer-In-Charge.All kinds of soil |
| 58 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 59 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 60 | Centeringandshutteringincludingstrutting,proppingetc.And removal of form for : Foundations, footings,bases ofcolumns, etc. for mass concrete |
| 61 | Centeringandshutteringincludingstrutting,proppingetc.and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 62 | SteelreinforcementforR.C.C.workincludingstraightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D |
| 63 | SteelreinforcementforR.C.C.workincludingstraightening, cutting,bending,placinginpositionandbindingallcomplete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D |
| 64 | Steel work welded inbuilt up section/framed work, including cutting, hoisting, fixing in position and applying a primer caot of approved steel primer using structural steel etc as required in gratings, frames, guard bar, ladder, railing, brackets gate and similar work all complete. |
| 65 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 66 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 67 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 68 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20 mm nominal size stone aggregate |
| 69 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos sheet. |
| 70 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total coated thickness 0.50 mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 71 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 72 | Supply ,installation ,testing and commissioning of turbo ventilator size 22\"\" stainless steel 430 grade approximate weight 4.85 kg. The ventilator should have air absorption of 7km/hr, 2240CFM with blade length 369m, wings of 80 mm ,outer wings 22\"\"-24 nos.inner wings 22\"\"-6nos,with self lubricating ball bearing etc.complete as per manufactures specification and stainless steel base plate etc as per direction of Engineer-in charge including cutting pre coated sheet. |
| 73 | White washing with lime to give an even shade : Old work (two or more coats) |
| 74 | Credit schedule: Old GI Pipe 15/20mm dia |
| 75 | Credit schedule: Old C.I. Pipe 100mm dia |
| 76 | Credit schedule: Old C.I Flushing cistern |
| 77 | Credit schedule: Asbestos sheet |
| 78 | Credit schedule:Old Truss pipes, MS materials etc. |