| Sl. No. | Item Description |
| 1 | SCHEDULE A BOQ |
| 2 | Surface excavation n.exc 30 cm deep and getting out in hard / dense soil complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.5m wide and not exceeded 1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth andgetting out in hard/densecomplete all as specified and directed. |
| 4 | M & L Plain cement concrete (1:4:8) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
| 5 | Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 6 | Removing surplus excavated earth (soil) to a distance n. exc 50 m & Depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed. |
| 7 | M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, etc and mass concrete all as specified. |
| 8 | Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 9 | M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, etc and mass concrete all as specified. |
| 10 | Formwork to Square,rectangular or polygonal rough surface of concreteof sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 11 | M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span etc complete all as specified and directed. |
| 12 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 13 | M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Chajja complete all as specified and directed. |
| 14 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed |
| 15 | Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 16 | M&L for RCCM-25 (Design mix)(using 20mm graded stone aggregate) as in slabs supported on walls etc complete all as specified and directed. |
| 17 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 18 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | Ditto, but 5mmdia and over upto and including 10mm dia in stirrups,spacer and binders complete all as specified and directed |
| 20 | M & L Pre-cast cement concrete block masonry with solid blocks, type B-1, PCC 1:2:4 using 20 mm graded aggregate, exc. 10 cm in width and setting in mortar 1:4 complete all as specified and as directed. |
| 21 | M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for rendering 5mm thick in CM 1:3 onconcrete surfaceof ceiling finishing even and smooth without using extra cement complete all as specified and directed. |
| 23 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface,finishing even and smooth without using extra cement but using watter proofing compound complete all as specified and directed. |
| 24 | Supply only water proofing compound complete all as specified and directed. |
| 25 | Providing and laying / fixing TPO (Thermoplastic Polyolefin) water proofing membrane of non-flammable waterproofing of roof which shall be a 1.5mm thick loose laid membrane using Fosroc Proofex ORG membrane, layers are overlapped to achieve a minimum weld of 110mm. Hot air welding can be either hand applied or by means of automatic machines and the roll\"s either end are overlapped with 110mm are in stagered positions and the membrane shall be laid over the layer of non-woven geotextile fiber (Minimum 200GSM). The separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane and the concrete substrate. The termination of Fosroc Proofex ORG by aluminium strop anchoring and sealant filling shall be as per manufacturer\"s specification. Water proofing membrane should be all weather proof and UV resistance. The TPO membrane shall have the following properties:(i)Thickness: 1.5mm(ii) Tensile Strength : >9 N/mm²(iii) Elongation at break : > 950% (ASTM D 412)(iv) Puncture resistance > 1000mm : Pass (EN 12691)(v) Water impermeability : Pass (EN 1298 & EN 12691)(vi) Tear Resistance : 470 N (EN 12310 - 1)(vii) Root Resistance : Pass Test - No Penetration(viii) Lap joint strength : Pass Test (EN 12317 & UEATc)Preparation of Surfaces: Surfaces should be free from cavities and projecting nibs. All surfaces shall be dry and free from frost, surface laitence and contamination. |
| 26 | Note for Water proofing treatment:(i) The work shall be carried out through authorized and qualified applicators of the following manufacturer\"s only. MOU to be submitted before commencement of work. Make:M/s FOSROC(ii) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified.(iii) The unit rate quoted is deemed to include taking down cables, wires, earthing strips, ac pipeline etc found on roof and refix the same at the original position after complete treatment of roofs(iv) The unit rate quoted shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto any height from natural ground level(v) All cracks at corner joints, channels and parapets should be properly treated. Bigger cracks, damaged portions & hollow areas must be repaired with polymer modified cement mortar.(vi) Necessary safety arrangement like safety belts, ropes, helmets, netting etc which are required for safety of working labour at height exc 3m to be provided by the contractor and the rate for this provision is deemed to be inclusive in the quoted rate. |
| 27 | M & L 40mm thick PCC 1:2:4, Type B-0, damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 28 | M&L for Polythene sheet 150 micron over a coat of Polymerized bitumen @ 1.5 Kg/Sqm complete all as specified and as directed |
| 29 | M&L for Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete all as specified and as directed |
| 30 | M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface complete all as specified and directed. |
| 31 | M&L for providing Cement concrete 100mm thick, type D-2, 1:4:8 (40mm gradedaggregate) under floors complete all as specified and as directed |
| 32 | M&L for providing Cement concrete 25mm thick, type B-0, 1:2:4 (12.5mm graded aggregate) under floors complete all as specified and as directed |
| 33 | M&L for light shadeVitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl 15mm thick screed bedin cement mortar (1:4) for laying floor finished completeall as spd / directed. |
| 34 | M & L Treating the top surface of filled earthwith anti termite treatment emulsion @5 litresper square metre of surface completeall as specified and directed. |
| 35 | M&L for cement concrete 1:3:6 type C2,75mm thick with using extra cemnet as in plinth protection complete all as specified and directed. |
| 36 | M&L preparing surface plastered or unplastered on wall with two coats of Cement base paint over a coat of alkali resistant primer paint with complete all as specified and directed. |
| 37 | M&L three coats of white wash on new plastered ceiling surface including preparation of surfaces complete all as specified and directed. |
| 38 | Material and labour for preparation of newly plasteredwall surfaces,applying 3 mm thick wall care putty andapplyingtwo coats of oil emulsion distemper over acoat of chalk whiting primer completeall as specified and as directed. |
| 39 | Material and labour for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put togather with glue pinned at joints all as specified and as directed. |
| 40 | M&L Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides,complete all as specified and directed. |
| 41 | M&L for Preparation of new wood or wood based surfaces over 10 cm width or girth and applying twocoats of synthetic enamel paint over a coat of pink primer all as specified and directed |
| 42 | S&FPowder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Eng-in-charge. |
| 43 | S&FPowder coatedanodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beadingscrews etc. complete all as specified directed by Eng-in-charge. |
| 44 | S&FPowder coated anodised aluminium frame for door section/ window section/ ventilator section for side hung type shutter /sliding type shutter/fixed type shutter in two or more tracks, including automatic locking handle , rollers and roller plate & fitting arrangement complete all asall as specified and directed by Engineer-in-charge.(Glass pane , hydraulic door closer , plush plate, floor hinges shall be measured and paid separately. |
| 45 | S & F in repairsDoor closer hydraulically regulated of Aluminium (Extruded section) body designation No.2, universe type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed. |
| 46 | M&L Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed. |
| 47 | M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular)area of each tiles exceeding 0.06 sqm but n.exc 0.11sqm in floor etc,over 15 mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 48 | M&L for glazed ceramic coloured cut tiles 450x350x7mm thickon verticalsurfaces such as skirting dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including10mm thick rendering in CM (1:4).Complete all as specified & directed. |
| 49 | M&L for Granite 20 mm thick(of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed. |
| 50 | M&L forGranite 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note : (a)The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors Complete all as specified & directed. |
| 51 | Material and labour for provision of new 4mm plain sheet glass ordinary quality and glazed with oil puttyarea of glassexc 0.5 sqm each panecomplete all as specified and directed. |
| 52 | S&F solid PVC door frame of size 50mm x 47mmmade out of 5mm plain colour PVC sheet reinforced with MS square tub complete all as specified and directed. |
| 53 | S &F Factroy madesolid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with het moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuch inside with solvent cement for stiles and plan colour PVC sheets for top rail, lock rail & bottom rail on either side & as fap insert for top rial & bottom rail, Penelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet the stiles & rails with suitable PVC sheet beadingand jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing. |
| 54 | S&F aluminium anodised barrel tower bolt 200 mmcomplete all as specified and directed. |
| 55 | Aluminium alloy, anodised, sliding door bolt 300 mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 56 | S&F MS 100 mm size butt hinges medium wt. of cold rolled complete and all as specified and directed |
| 57 | Aluminium handles, cast type anodised150mm size complete all as specified and directed. |
| 58 | M&L in Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty including taking down existing wire cloth all as specified and directed. |
| 59 | S&F in repairs Pillar taps fancy type 15mm bore CP with capstan head screwed down high pressure screwed for iron pipe complete as directedby Engr-in-charge. |
| 60 | S&F in repairs Bib Cock CP fancy typewith wall flange screwed down screwed for iron pipe15mm bore in repiars complete as directedby Engr-in-charge. |
| 61 | S & F in repairsCP Hand shower (Health Faucet) with 1M Flexible tube with 8mm dia wall hook with NRV (Back flow preventor)including taking down existing oneComplete all as specified and as directed. CAT Part No ALD CHR-579 Jaquaror equivalent in Parryware, Cera |
| 62 | M&L PVC connection 15 mm size with PTMT nuts of length 450 mmincluding taking existing one complete as directedby Engr-in-charge. |
| 63 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement complete all as specified and directed. |
| 64 | S&F PVC (SWR) pipes 75mm dia single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 65 | S&F PVC (SWR) pipes 110mm dia single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 66 | S&F in repairs 75mm dia PVC (SWR)bends any radius complete all as specified and as directed |
| 67 | S&F in repairs 110mm dia PVC (SWR)bends any radius complete all as specified and as directed |
| 68 | S&F in repairs 110mm dia PVC (SWR) vent cowl complete all as specified and as directed |
| 69 | S&F in repairs 75mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed |
| 70 | S&F in repairs 110mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed |
| 71 | S&F in repairs Grating doom 125 mm dia with waste hole of PTMT Minimum weight 40 gms complete all as specified and directed. |
| 72 | S&F in repairs Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed. |
| 73 | S & F for Toilet paper holder of vitreous china box typefixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 74 | S&Fin repirs 20 MM bore dia of pipe Ball brass valves. high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule i complete all as manufactures and all as specified and directed by Engineer- In - charge |
| 75 | S&F in repair Vitreous china wash down water closet pan with S-TRAP (pedestal pattern) (Size 640 x 365 x 695 mm) of Parrywareincluding flushing cistern and all accessories (Cat part No. C899E(S-110), complete all as specified and as directed |
| 76 | S & F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs withand including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and Union for discharge pipe complete all as specified and as directed.. |
| 77 | S & F in repairs vitreous china squatting pan \" Orrisa\" pattern size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe and complete including provision of lime concrete bedding complete all as specified and as directed. |
| 78 | S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 Ltrs capacity , low level , white, with inlet , ball valve, float and handle including brackets and flush pipe etc complete all as specified and as direted by Engineer-in-Charge. |
| 79 | S&F in repair Vitreous Bowlwash basin, white, flat back, size 460 x 315 x 135 mm (Cat Part S No. G895V) of parrywareexcluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed |
| 80 | M&L 32 mm Waste fittings, inrepirs brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing one complete all as manufactures and all as specified and directed by Engineer- In - charge |
| 81 | S&F in repairs chromium plated angle valves, cast copper alloy, screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipes or for unions and fixed. 15 mm size complete all as specified and directed. |
| 82 | S&F in repairs soap dish vitreous china white approximate size 100 x 160x90 mmbrass screws complete all as specified and directed |
| 83 | S&F for 600mm x 450 mm bevelled edge mirror of selected quility glass, mounted on 6 mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass screwesand cup washers complete all as specified and as directed. |
| 84 | M&L brass chromium plated tubular towel rail 20mm dia D type 600 mm long between flanges fixed Complete all as specified and directed. |
| 85 | S&F in repair 15mm bore Brass CPwall mixer for mixighot & coldwater screwed down , for iron pipe or for brass ferrule complete all as specified and directed. |
| 86 | S&F PVC \"S\" trap 110mm all as specified and as directed |
| 87 | S&Fin repairs shower rose 125 mm brass chromium plated with swivel joints complete and all as specified and directed. |
| 88 | S&F of 3- layer PP-R Polypropylene random copolymer)concealed Outer diameter of pipes in16 mm dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold waterapply all PP-R plain & brass threaded polypropylene random fittings laid in floors,wall and ceilling etc complete all as specified and directed. |
| 89 | S&F of 3- layer PP-R Polypropylene random copolymer)concealed Outer diameter of pipes in20 mm dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold waterapply all PP-R plain & brass threaded polypropylene random fittings laid in floors,wall and ceilling etc etc complete all as specified and directed. |
| 90 | S&F of 3- layer PP-R Polypropylene random copolymer)concealed Outer diameter of pipes in25 mm dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold waterapply all PP-R plain & brass threaded polypropylene random fittings laid in floors,wall and ceilling etc complete all as specified and directed. |
| 91 | M & L Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 92 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., including removing debris material to out side MD land complete all as specified and directed. |
| 93 | S&F in repair 20 mm dia decorative type curtain rodwith rings and brackets complete and all as specified and directed |
| 94 | S&F in repairs Brass chromium plated bottle traps 32mm bore dia for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed |
| 95 | M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 96 | M & Lbrick work with sub class B bricks straight or curved on planexc 6 m mean radius built in cement mortar 1:4complete all as specified and directed. |
| 97 | M & Lbrick work with sub class B bricks straight or curved on planexc 6 m mean radius built in cement mortar 1:4complete all as specified and directed. |
| 98 | M & L PCC 1:2:4 types B-1 (using 20 mm graded crushed stone aggregate) as in coping etc complete all as specified. |
| 99 | M&L for cement concrete in 1:3:6 type C2,50mm thick (40 mm graded stone agg in )surface channel and drain, complete all as specified and directed. |
| 100 | Extra for fixing fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including foms, moulds,mitred/stopped ends etc. complete all as specified and directed. |
| 101 | Providingprecast cement concrete (PCC 1:3:6), type C-1) using 20 mm graded stone aggregate in landing, cover slabs(for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar CM 1:4 complete all as specified and directed. |
| 102 | Supply and laying double wall corrugated DWC pipe HDPE pipe ofdia 150 mm of approved make ISI marked polythene with smooth internal wall & profiles external surfaces for non pressure for sewage complete all as specified. |
| 103 | M&L for concrete bed to drain pipes in PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate including packing under haunching against the sides of pipe after they are laid and tested for 150mm diacomplete all as specified and directed. |
| 104 | Wiring complete with 1.5 sqmm single core PVC insulated, sheathed FRLS 1100 volts grade,FRLS cable and incl PVC conduitwith accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with modular frame with cover etc and 1.5 sqmm PVC insulated, sheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 105 | One light point/fan/bell point controlled by one switch |
| 106 | All as per item No. 104 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 107 | All as per Sl No 103 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently |
| 108 | S&F modular switch 1 way 6 Amps, 1 module complete all as specified and directed. |
| 109 | S&F modular switch 1 way 16 Amps, 1 module complete all as specified and directed. |
| 110 | S&F white cover plate with frame, 3 Module complete all as specified and directed. |
| 111 | S&F white cover plate with frame, 6 Module complete all as specified and directed. |
| 112 | S&F metal flush box 3 module complete all as specified and directed. |
| 113 | S&F metal flush box 6 module complete all as specified and directed. |
| 114 | S&F electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module. |
| 115 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 116 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed. |
| 117 | Flame proof Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduitwith accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to wallsand 1.5 sqmm PVC insulated, unsheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 118 | One light point/fan/bell point controlled by one switch |
| 119 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V |
| 120 | S&F junction box dia 120x70H all as directed. |
| 121 | Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistanttoughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 122 | S&F ceiling rose, surface type Bakelite 65x55mm3 terminal complete all as specified and directed. |
| 123 | Supply and fixing replacementfactory madepowder coated distribution board TPN 4 way, double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and directed |
| 124 | Supply and fixing replacementfactory madepowder coated distribution board SPN 8 way, double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and directed |
| 125 | S&F Triple pole Nuetral MCB 32 Amp , 415 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 all as specified |
| 126 | S&F MCB SPN32 Amp , 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 all as specified |
| 127 | Supply and fixing singlepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996all as specified |
| 128 | Sub main wiring for circuit complete with 4 X 6 sqmm single core PVC insulated, unsheathed FRLS1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and incl 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductoretc and all as specified.Note : 4x6 sqm + 2 x 4 sqm and PVC casing and capping shall be measured together as one RM. |
| 129 | S&F sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including metalic steel conduit and conduit accessories consealed in wall,ceiling etc. ISI marked32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cableas earth conductor complete as specified. |
| 130 | M&L earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth strip 32mmx6mm thick and GIbolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnelfor watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber withRCC cover slab, salt, charcoal and MS hook, ane provn of test point complete all as specified and directed.Note : 3 Run of 4 sqm cable and conduit measuring together as one RM. |
| 131 | Supply and install,testinverter type split unit of capacity 1.5TR ,5star rated,indoor and outdoor complete with non-CFC refrigerent gas R-32/R407C/R410 etc ,minmum inverter type, turbo cooling, twin rotary compressor BDLC type ,wide air flow blade, wide powerful air throw, with minmum filters like Anti dust filter.Anti microbal filter,antibacteial coating, adjustable temparature settings, Active dehumidifier, auto restart 24 hrs timer, auto cooling fan mode with adustable variable speed settings, operating on 230 Volt single phase AC supply,50Hz and also compitable for wide range of voltage variations(i.e 170v -260v)with coordless remote control unit,dispay,adjustable swing,nosie level lessthan 45db for indoor unit and filter configuration complete includingnecessary all electrical and mechanical connections as required for complete operation of AC unit and necessary fixing arrangement as per relevent IS (indoor unit at suitable place and height inside the room and out door unit at suitable place and as directed. including metalic bracket with fixing place suiatble size and length bolts for outdoor unit and inclduing necessary insulatedcopperpiping and drain pipeetc complete all as specified and as directed |
| 132 | Supply and fixing and testing of 4 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of± 2.5%complete all as per manufacturers instructions and directed by Engineer-in-Charge |
| 133 | S&F 1-ph,two pin with earth, metal clad earth plug socket with sheet metal enclosure controlled by Single pole MCB 5 to 32(selection of MCBrating & its load curve should be match with load) Amps-01 No capacity operating on 230 V AC 50Hz electric supply complete ,including making good all disturbed surface etc complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail