Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling timber scantlings 40 Sqcm and over in section , in any position ,framed work complete all as specified and directed. |
| 2 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roofcoverings complete all as specified and directed. |
| 3 | S&F mild steel work in tubular hollow rectangular trusses, purlins, rail including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade inluding one coat of zinc chromate primer before fabricationdistance pieces, cleats etc GDE Fe 410-S. complete all as specified and directed. |
| 4 | S&F pre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 5 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 6 | Providing & fixing false ceiling at all heights with GRG (Glass FibreReinforced Gypsum) false ceiling tiles ofSize 595 x 595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS8225:1987, Noncombustible as per BS4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. including dismantling of old false ceiling complete all as specified. |
| 7 | Demolition of brick or stone / boulder work built in cement mortar as in quoins, arches,pillars etc. complete all as specified and directed. |
| 8 | M&L for brick work with fly ash brick in CM 1: 6 straight or curved on plan exc 6 m mean radius complete all as specified and directed. |
| 9 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick in CM 1:6 on brick masonary wall surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed. |
| 11 | M&L 15mm thick rendering in cement mortar 1:4 to on brick masonary wall surfaces or on other than fair faces of brick masonary fairfinishedwithout using extra cementcomplete all as specified and directed |
| 12 | M&L 5 mm thickrenderingon Ceilingconcrete surfaces in cement mortar 1:3 with water proofing compound, incl finish even and fair w/o using extra cement complete all as specified |
| 13 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisesas specified and directed. |
| 14 | M&L for Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile laying over 15 mm thick cement mortar 1:6 for floor finishes complete all as specified and directed. |
| 15 | M&L for glazed ceramic tiles in vertical surface 600X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match colouredtile including 10 mm thick renderingcomplete all as specified and directed. |
| 16 | M&L for ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm( 600 x 600 ) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl screeding 15mm thick in CM 1:6, complete all as specified and directed |
| 17 | All as per serial item No 16 but as in vertical surfacesincl plastering 10mm thick in CM 1:4 complete all as specified and directed. |
| 18 | M&L for 16 to 18mm thick coloured composite tiles (Granite) area of each tile exceeding 1.20 Sqm but not exceeding 1.50 Sqm in floors etc set and jointed in neat cementslurry and pointed in whiteor colouredcement to match over 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes even and rough with and including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. Note : Colour of composite tiles shall be approved by GE. |
| 19 | M&L for 16-18 mm thick Granite of Z-black in colour(table rubbed and polished) as in windows cill, door cill,gate pillar/post & cooking platforms and like in cement mortar (1:4)in matching thikness including form work , pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as specified and directed. |
| 20 | Demolition of Concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 21 | M&L for 40 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in floors,finished rough to receive floor tiles complete all as specified and directed |
| 22 | S&F steel windows/ventilator with pressed steel frame (size 95 x 45 x 1.25 mm ) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar ( open out side ) and wire gauged openable shutter without glazing bar ( open inside ) dovetailed or welded complete all as specified and all as per DRG No TD/088 dt 07 Jan 2002Note :- (i) Two shutters ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit(ii) rate for filling PCC in frame deemed to be included in quoted rates (iii) MS grill shall be measured and paid seperatly under relevant item of schedule |
| 23 | S&F sheet glass 3 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 24 | S&F in repair stainless steel wire mesh 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned takes or galvanised Wire staples complete all as specified and directed |
| 25 | S&F mild steel framed work such as grills grating etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks, hole fast and similar work confirming to Fe -290 Gde-E-165 complete all as specified and directed. |
| 26 | Taking down chowkhat or frame with shutter (without taking off single shutter/ double shutter from the frame)exc 1.5 sqm and n exc 4.00 swm incl removingfrom the premises complete all as specified and directed. |
| 27 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n. exc 1.5 sqmincl removingfrom the premises complete all as specified and directed. |
| 28 | M&L providing FACTORY MADE PVC INTERNAL DOOR FRAME (PRELAM) of size 100 mm x 45 mm with a wall thickness of 5 mm (+- 0.25 mm ) made out of extruded 5 mm (+- 0.25 mm ) thick PVC sheet manufactured by an ISO 9001-2008 certified company and by joining 3 nos Heat bent PVC sheet sections. the inside section of size 90x30 mm shall be made from plain colour PVC sheet of 5 mm (+-0.25 mm ) thickness the inside section will be covered by sticking two sections of size 30 x 35 mm and 70 x 45 mm made from (+-0.25) thick plain PVC sheet The frame shall be mitre cut at two corners and joined with 4 nos of 150 mm long brackets of 15 mm x 15 mm MS square tube The two vertical door frames are to be reinforced with 40 mm x 20 mm MS tubes of 19 guage through out the farme The door frame shall be fixed to the wall using 8/100 mm long screw through the frame by using anchor fastners. A minimum of 4 nos screw to be provided for each vertical members and minimum 2 nos for horizontal member etc complete as per manufacturers specifications and directions of Engineers-in-charge |
| 29 | M&L providing 30 mm thick factory made internal PVC flush door shutter wood free consisting of frame made out of M S tubes of 19 guage thickness and size 20 mm x 40 mm for siles as well as top bottom and lock rail MS frame shall have a coat of metal primer of approved make and manufacturer. The inside panel shall consist of 20 mm thick multichamber hollow PVC section 1 mm wall thickness bonded using solvent cement/ cynoacrylate adhesive with 5 mm (+-0.25 mm) thick plain/prelam PVC sheet manufactured by an ISO-9001-2008 certified company on both side of the inside panel All the four edge of the panel to be sealed with lipping of 10 mm thick and 20 mm wide PVC sheet baton( made by sticking 2 nOs PVC sheet of 5 mm ( +0.25 mm ) thickness using PVC solvent cement adhesive Door edge lipping to be painted with PVC ink of matching colour of plain/prelam moulded PVC sheet of door 0.20 mm thick ( 5mm x 4 mm) thick PVC sheet to be given for lock provision at lock height. Door to be fixed with frame with 3 nos stainless steel butt hinges of size 100 mm * 25 mm * 25 mm and 50 mm long steel screws drilled suitable to pass through both the wall of the MS tube other hardwares should be fixed with 25 mm * 8mm size steel screws etc complete as per direction of Engineer-in-charge, manufacturers specification and drawing |
| 30 | M&L for 125x 60 x 2 mm thick pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., including filling with PCC 1:3;6 B1 using (12.5 graded stone agg) complete, as specified, supplied and fixed complete all as specified and directed. |
| 31 | S&F flush shutters, 30 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 32 | S&F 2nd class hardwoodglazed and Skelton shutters 30 mm thick open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, stiles and rails as specified in SSR Part I section 8 clause 8.20 (a) supplied and fitted to chowkhats complete all as specified and directed. |
| 33 | S&F Butt hinges, medium weight, Stainless steel and fixed of size 100mm complete all as specified and directed. |
| 34 | S&F aluminum anosided barrel tower bolts 150mm long, of extruded section and fixed complete all as specified and directed. |
| 35 | S&F aluminum anosided handle 150mm long of extruded section and fixed complete all as specified and directed. |
| 36 | S&F300mm sizealuminium alloy anodised sliding door bolt with hasp & staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast alluminium alloy complete all as specified and directed. |
| 37 | S&F 150mm mild steel helical door spring complete all as specified and directed. |
| 38 | Taking up or down15 mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed. |
| 39 | Taking up or down20 mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed. |
| 40 | S&F 15 mm dia steel water tubing galvanized medium grade concealed in all type wallwith all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. |
| 41 | S&F 20 mm dia steel water tubing, galvanized, medium gradeconcealed in all type wallwith all fittings,fixed to walls and ceiling or in floor complete all as specified and directed. |
| 42 | S&F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 43 | S&F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) completed all as specified and directed. |
| 44 | Demolition ofReinforcement cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 45 | M&L forreinforced cement concrete 1:1.5:3 type A-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall,landing, balconies, shelves and like including bonding agent complete all as specified and directed. |
| 46 | S&F TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0 complete all as specified and directed. |
| 47 | S&F 140 mm long floor door stopper of aluminium alloy body and tongue, brass body and tongue with hard drawn steel spring complete all as specified and directed. |
| 48 | S&F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 49 | S&F in repair 20 mm bore Gun metal, globe or gate valve,with iron wheel head, screwed both ends for iron pipes fixed complete all as specified and directed. |
| 50 | S&F in repair Vitreous china wash down water closet (pedestal pattern) white complete, including connection to drain pipe and to flushing pipe antisyphonage pipe including P Trap etc complete all as specified and directed. |
| 51 | S&F in repairs plastic water closet white seat cover closed pattern with flat bottom cover and mild steelchromium plated or aluminized hinging device complete all as specified and directed. |
| 52 | S&F in repairs Vitreous china wash basin white flat back 550mm x 400mm excluding tap but, waste pipe, chain & plug but including brackets of iron angle complete all as specified and directed. |
| 53 | S&F in repairs 32 MM CP waste coupling, complete fitting for wash basin complete all as specified and directed. |
| 54 | S&F in repairs centre hole basin mixture 15 mm dia chromium plated complete all as specified and directed. |
| 55 | S&F in repairs 2 in 1 chromium plated 15 mm dia wall mixture withconnectionfor shower arragement complete all as specified and directed. |
| 56 | S&F in repairsPVC waste pipe 25 mm dia 750 to 800mm long fixed to waste fitting of wash basinincluding socket suitable for waste fitting complete all as specified and directed. |
| 57 | S&F in repairs chromium plated fancy type stop vlave /angle valves/ two way angle valve with cup cast copper alloy screwed down high pressure, screwed both ends for iron pipes or for unions for 15 mm bore pipe complete all as specified and directed. |
| 58 | S&F in repairs chromium plated fancy type long body bib taps with cast copper alloy screwed down, screwed for iron pipe or for brass ferrule for 15 mm bore pipe complete all as specified and directed. |
| 59 | S&F in repair of PVC corner set of three of size (12\"X12\" ,9\"X9\" and6\" X6\" ) with railling and complete all as specified and directed. |
| 60 | S&F in repairs tubular, towel rack brass chromium plated 20mm dia D type 60 cm long between flanges complete all as specified and directed. |
| 61 | S&F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP bracket gaurd and railling 60 cm long complete all as specified and directed. |
| 62 | S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed |
| 63 | S&F Brass CP hand shower (health faucet)with 8mm Dia 1.0 Meter Long Flexible Tube and Wall Hookscrewecd for iron pipe fancy type long body complete all as specified and directed. |
| 64 | S&F in repair water jet of EWC chromium plated with PVC connection complete all as specified and directed. |
| 65 | S&F in repairPVC (SWR) floor trap with CP grating including jointing with solvent cement floor trap 75 mm dia outlet plain with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed. |
| 66 | Dismantling of cast iron /PVC/ AC/ SGSW pipes 100mm dia jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 67 | S&FPVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting complete all as specified and directed. |
| 68 | S&FPVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting complete all as specified and directed. |
| 69 | S&F PVC (SWR) 110mm bore bends anyradiuscomplete all as specified and directed. |
| 70 | S&F PVC (SWR) 75mm bore bends any radiuscomplete all as specified and directed. |
| 71 | S&F designed looking mirror size exc 0.54 sqm to 0.75 sqm of selected quality 6mm thick glass, mounted on fixed to wall with CPplugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 72 | S&F in repair20 mm dia stainless steel 1.0 mm thick fancy typecurtain droppery rod with decorative design matching brackets as approved and knobs (lattu) or end bracket as required incl fitting with 80 mm long SS screw with 75 mm long wooden gitty of appropriate c/s in each end & intermediate support complete all as specified and directed. |
| 73 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified and directed. |
| 74 | M&L for preparation of newuntreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coatof pink primer complete all as specified and directed. |
| 75 | M&L for preparation of newly plastered surfaces of walls and applying two coat of weather proof exterior emulsion paint over coat of 1mm thickof birla wall care putty complete all as specified and directed.(Note : Colour and patterns to be applied as per new colour scheme approved by Stn Cdr) |
| 76 | M&L for preparation of old decorated surfaces of walls by brushing, scrapping down smoke soot mouldsby steel wire brushand applying two coat of weather proof exterior emulsion paint with airless electric sprayersover coat of 1mm thickof birla wall care puttycomplete all as specified and directed.(Note : Colour and patterns to be applied as per new colour scheme approved by Stn Cdr) |
| 77 | M&L for preparationofnewly plastered surface of walls and applying Two coats of distemper oil emulsion with airless electric sprayers over 1 mm thickness birla wall care putty including necessary scoffolding upto Four storey building height ofcomplete all specified and directed Note :- (i) Application to be done through authoried apllicator manufacturer. (ii) Putty surface to be rubbing downwith sander machine after getting dried all as directed to obtain a smooth & even surface. |
| 78 | M&L for complete removal of old distempered surface of walls including brooming down or steel wire brushing, scrapping down smoke soot moulds, Moss and efflorescent salts and trading oil and greasy spots and applying two coats of distemper oil emulsion with airless electric sprayers over 1 mm thickness birla wall care putty including necessary scoffolding upto Four storey building height complete all specified and directed Note :- (i) Application to be done through authoried apllicator manufacturer. (ii) Putty surface to be rubbing downwith sander machine after getting dried all as directed to obtain a smooth & even surface. |
| 79 | M&L for preparation of newely plastersurfaces and applying three coat of white wash on ceilings complete all as specified and directed. |
| 80 | M&L for Providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar 1:2 to match the existing apron complete all as specified and directed. |
| 81 | M & L for Post Construction Anti TermiteTreatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor complete all as specified and directed. |
| 82 | Dismantling of roof terracing cement / brickconcrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified and directed. |
| 83 | M&L for 25mm thick cement concrete type B1 1:2:4 using 20mm graded stone aggregate in roof finishes even and fair to receive floor tiles complete all as specified and directed. |
| 84 | Supply and providing water proofing treatment with polymeric standard water proofing membrane 3 mm thick having 10 years guarantee for water tightness all as specified and directed and described as under : (a) Prepartionof RCCroof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/Sqm including cleaningsurface, all as per manufacture\"s specification complete all as specifiedand directed.(b) Supply & Providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced/ torch application of membrane with 10 cm overlaps as required thereof, complete all as specifiedor as directed. |
| 85 | M & L for applying one coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified and directed. |
| 86 | Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in sof/loose soil complete all as specified and directed. |
| 87 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete all as specified and directed. |
| 88 | Removing surplus excaveted soil to a distance exc 250 Mtr and nexc 500 Mtr depositing where directed at a level n. exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 89 | Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced) 150mm dia set in cement mortar complete all as specified and directed. |
| 90 | M&L for 150 mm bore reinforced concrete pipes class N P-2, laid and jointed complete with collars layring over concrete bed for 150mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 91 | M&L proving pre cast reinforced cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in landing cover slab for main holes chullah hoods chajjas water toughs manger shelves and similar articles with plain faces setting in CM (1:6) complete all as specified and directed. |
| 92 | S&F TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0 complete all as specified and directed. |
| 93 | M&L 15mm thickrenderingon wallsbrick or concrete surfaces in cement mortar 1:4 with, incl finish even and smooth without using extra cement complete all as specified and directed. |
| 94 | M&L forrubber molded cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of80mm thickness with grey cement and pigmentation, M-35 Grade,pattern and colour as approved by GE and over and inclduing 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavingsall completed as specified and directed. |
| 95 | M&L Sand filling under floors or in foundation/ LT UG cable 25 mm thickincluding watering and consolidation complete all as specified and directed. |
| 96 | M&L for providing cement concrete type B1 1:2:4 using 20mm aggregates in kerbs or mud stops rounded edges completed all as specified and directed |
| 97 | M&L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length.Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed. |
| 98 | S&F in repairs factory made PVC Cupboard frame of the size 75mm x 40mm with a wall thickness of 5mm, made out of extruded 5mm thick plain/prelam PVC sheet of density 600 kg/cbm, having bottom width of 50mm and thickness of 10mm. All four frame lengths reinforced with 15 mm x 15mm M. S. square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners adjointed with 2 nos. of 15mm long brackets 0f 10mm x10mm M S square tubes. The door frame shall be fixed to the wall using 8/100 long M S screws through the frame by using PVC fasteners. A minimum of 4 nos. of screws to be provided for each vertical member and minimum of 2nos. of screws to be provided horizontal member etc. complete as per direction of Engr-in-Charge, manufacturer\"s specification and drawing. |
| 99 | S&F factory made PVC cupboard flush type shutter of 30mm thick consisting of frame made out M S tubes of 19 gauge thickness and size 19mm x 19mm for stiles and rails. The inside panel shall consist of 20 mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement/ cynoacrylate adhesive with 5mm thick plain/prelam PVC sheet, on both side of inside panel incliding necessary items to fix the shuter to frame such as 100mm stailess steel hinges, 100 mm long handles made of designed stainless steel and magnetic ball catch for each pair of shutter.All four edges of the panel to be sealed with lipping of 10mm thick and 20mm wide PVC sheet baton (made by sticking 2nos. PVC foam sheet of 5mm thickness using PVC solvent cement adhesive).complete as per direction of Engr-in-Charge. |
| 100 | S&FPVC boards 19/20 mm thick any colour/ prelaminatedas in cabinets incl shelves and shutters, fixed with screws and adhessive as per direction of Engr-in-Charge and, manufacturer\"s instructions including piano hinges, magnet catcher, handles etc. complete all as specified and directed |
| 101 | Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed |
| 102 | Taking down carefully UNSV main switch DBs of any description of an size in any position complete all as specified and directed |
| 103 | Taking down submain wiring including all accessories complete all as specified and directed. |
| 104 | Material and labour for point wiring for One light / fan/ exhaust fan point controlled by one switchwith single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered withmodular plateand cover of suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- |
| 105 | (b) One 5 pin 5 Amp switch socket out let point on an independent board.complete all as specified and directed |
| 106 | (c) One 5 pin 5 Amp socket out let point controlled by one switch on same board. complete all as specified and directed |
| 107 | (d) One buzzer/ bell point controlled by one push button on the same board with other switches or independent complete all as specified and directed |
| 108 | All as per item 104 here in before but for one 15 Amp 6 Pin switch socket out let independent with2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistrandedincl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified. |
| 109 | S&F Modular switch one way 6 A, 1 Module complete all as specified and directed. |
| 110 | S&F Modular switch one way 16 A, 1 Module complete all as specified and directed. |
| 111 | S&FModular bell push 6 Amp, 1 Module complete all as specified and directed. |
| 112 | S&FModular Socket 6 Amp, 2/3 Pin combined 2 Module complete all as specified and directed. |
| 113 | S&FModular Socket 6/16 Amp, 2/3 Pin combined 2 Module complete all as specified and directed. |
| 114 | S&FModular fan regulator Step up type, 120 Watt, 2 Module complete all as specified and directed. |
| 115 | Supply and Fixing ceiling rose PVC/ Poly carbonate,Isolated body, threeterminal AC 230 volts complete all as specified and directed. |
| 116 | S&F in replacement LED mirror light fitting of 1 x 10 wattLED batten with aluminium housing with all accessories prewired suitable for wall /surface mounting complete with connection all as specified and directed. |
| 117 | S&F in replacement LED mirror light fitting of 1 x 20 wattLED batten with aluminium housing with all accessories prewired suitable for wall /surface mounting complete with connection all as specified and directed. |
| 118 | S&F indoor decorative LED City-3 light fitting suitable for & including single 12 Watt LED lamp with polycarbonate body with upper globe complete all as specified and directed. |
| 119 | M&L for replacement oflamp holder, PVC / Poly carbonate, insulated bodymodular type with back plate batten/angle type for batten fittings complete all as specified and & directed |
| 120 | S&F LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed. |
| 121 | Supply and fixing Buzzer, Ding Dong AC. 230 volts,single pole complete all as specified and directed |
| 122 | Supply & Fixing security light fitting, LED type, 25 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source withintegrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with andincluding nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. |
| 123 | M&L for sub main wiring with two single core 6.0 Sqmm (FRLS)copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :-Two runs of 6.0 sqmm (FRLS) and one run of 6.0 sqmm (FRLS) copper conductor shall be measured as one unit length.) |
| 124 | Taking down carefully ceiling fan from existing siteand dopositedin MES yard for BER in coming BOOall as directed by Engineer-in-Charge. |
| 125 | Taking down carefully exhaust fan from existing siteand dopositedin MES yard for BER in coming BOOall as directed by Engineer-in-Charge. |
| 126 | Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 127 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 128 | M & L for Hole cutting in wall for fixing of exhaust fan of size 300 mm and good the disturbed surfacres of wallby using putty and match with existing colour of wall complete all as specified and directed.Note:Cost of repairing work and material ( cement and sand) included in quoted rate. |
| 129 | S&F MCB SPN 40 Amp 240 volt complete all as specified and directed. |
| 130 | S&F MCB single pole 6 to 32 Amp 240 Volt \"B\" curve 10 KA complete all as specified and directed. |
| 131 | S&F MCCB triple and neutral 40 to 100 Amps 415 volt 10 KV \"B\" complete all as specified and directed. |
| 132 | S&F flush sheet metal enclosure SPN DB 12 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral linkscomplete including taking down old unsv all as specified and directed. |
| 133 | Supply and fix TPN DB -TPN DB 4 way with provn and including of MCCB 63 Amps , 415 Volt, 3 Phase, 4 wire AC 50 Hz having aluminium Bas Barphase and the neutral insulated with PVC sleeves, connected with appropriate size copper thimbles complete all as specified and directed. |
| 134 | Material & Labour for earthing complete including taking out old unsv and replacewith galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased inand including 15 mm dia GI \"light grade\" pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe \"light grade\" as water pipe from earth chamber andincluding excavation and earth work, PCC 1:3:6 typeC1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced complete all as specified and directed |
| 135 | Taking down carefully service connections of any description from pole, wall or service brackets etc. including making good distrubed surface to match with the existing surface complete all as specified and directed. |
| 136 | Supply, laying & testing UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electri power cable (heavy duty) 100 volts grade with stranded aluminum conductor of size 25 Sqmm 3.5 core complete all as specified and direted. |
| 137 | M&L for modular bricks common burnt clay building bricks, sub class \"B\" designation -75 for LT UG Cable protection complete all as specified and directed. |
| 138 | S&F for GI tubes, light grade, of 80 mm dia, with all fittings and fixed complete for protection of LT UG Cables, laid in flooor or fixed on walls or along with poles etc complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail