| 1 | Dismantling asbestos cement (corrugated or semi corrugated ) sheets in roof covering including hooks complete all as specified & directed. |
| 2 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws complete all as specified & directed. |
| 3 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws as specified and directed. |
| 4 | S&F Mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to FE 410-0 of 310-0 complete all as specified & directed. |
| 5 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats et conforming to I. S 1161-1979 grade St.-240. complete all as specified & directed. |
| 6 | Dismantling wall and ceiling board (fibre,pulp,insulations etc)or insulation board any thickness including cover fillets complete all as specified and directed. |
| 7 | M&L for Anodised alumunium snap grid frame work for false ceiling grid of size 605mmx605mm complete hanges from GI wire complete all as specified and as directed. |
| 8 | S&F 4mm thick texture finish type ceiling board fixed to timber/metal framed work with screw as in ceiling snap grid complete all as specified and as directed. |
| 9 | Taking down cement plaster on brick or concrete or stone walls etc including racking out joints hacking for key scrubbing down with water any description.complete all as specified & directed. |
| 10 | Material & labour 15mm thick rendering in CM 1:6 on fair fair faces of brick wall orconcrete surfaces finished even and fair complete all as specified |
| 11 | Material & labour 15mm thick rendering in CM 1:4 on fair fair faces of brick wall orconcrete surfaces finished even and fair complete all as specified |
| 12 | Materials & labour for prepration of NEW plastered surface and finishing the surfaces of wallwith 1mm thick wall care puttyand applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 13 | Materials & labour for prepration of OLD plastered surface and finishing the surfaces of wallwith 1mm thick wall care putty and applyingtwo coat with complete removal of existing treatment by scraping old paint of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 14 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of wall.complete all as specified & directed. |
| 15 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of ceilling.complete all as specified & directed. |
| 16 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.all as directed. |
| 17 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over incl 20mm thick cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and incl screed bed of CM 1:6 complete all as specified and directed. |
| 18 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and inclCM 1:4 complete all as specified and directed. |
| 19 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each.all as directed. |
| 20 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each.complete all directed. |
| 21 | M&L for Pressed steel frames of section 125 x 60 mm for doors with one or more rebates including supply andfixing lugs, hinges, lock strick plate etc complete all as specified & directed. |
| 22 | S&F 2nd class hardwood factory made 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated. complete all as specified & directed. |
| 23 | M&L for Glazed and skeleton shutters 35 mm thickopen rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a); for doors supplied and fitted to chowkats complete all as specified and directed. |
| 24 | M&L for preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 25 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 26 | M&L for preparation of old wood and wood based surfaces of anydescription over 10 cm width or girth & applying one coat of synthetic enamel paint of any tint all as specified and directed by Engr-In-Charge. |
| 27 | Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thick ( above or belowGL) complete all as directed. |
| 28 | M&L for 75 mm thick PCC 1:3:6Type C-2 using 20mm graded aggregate as in plinth protection etc, laid to slope of 1:12 and shall be laid in alternate bays n.exc 1.5 m in length, joints 20mm wide will be provided every 1.5m and filled with ceiling compound grade ‘A’ the joints between external wall and plinth protection shall also be laid with ceiling compound grade ’A’, finishedcement concrete surface even and smooth all as specified. |
| 29 | S&F Aluminium, anodised, barrel tower bolts of 200 mm long and 10mm dia stove enamelled black with bright bolt fixed complete all as specified and directed. |
| 30 | S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed. |
| 31 | Supply & fixing125 mm Aluminium handles, cast type, anodised fixed complete all as specified & directed. |
| 32 | S&F powder coated Aluminium three track sliding glazed window manufactured with approved aluminium section with three sliding shutters each shutter width one half of the length of window with the following specifiecation and making good the adjascent surfaces :-(a) Window frame of cross section 101mmx40mmx1.5mm thick.(b) Three way track for smooth slding shutters of cross sections 91.80mmx31.75mmx1.1mm thick. (c) Sliding shutter frame of cross section 40x18x1mm.(d) Aluminium glazing stip of size 18.2x16.66mm. (e)4mm thick flat glass superior quality for two shutter. (f) IDPE rubber gasket for fixing glass. (g) Locking cleat/device as shutter 01 Nos. (h) 02 Nos sliding roller per shutters. (j)aluminium wire cloth 0.36mm stainless steel nominal dia of wire and average width of aperature 1.40mm for one shutter.(k) Fixing screws for frame with wall 06 per window with fancy design.(Note: Window will be measured outer to outer frame and no extra to be paid.) |
| 33 | Demolition of brick work built in cement morter including all quoins, arches, pillars etc, complete all as directed. |
| 34 | Material & labour brick work with fly ash bricks in CM 1;6 brickstraight or curved on plain exeeding 6m mean radius complete all as specified & directed. |
| 35 | S&F 80 mm thickMachine pressed precast concrete colouredinterlocking paver block any shape and size confirming to IS 15658-2006 , M-40 Grade with grey cement and no pigment complete all as specified and directed. |
| 36 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed. |
| 37 | M&L for supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 Mm thick in each layer complete all as directed |
| 38 | M&Lfor Cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate 25 mm thick for laying of floor etc complete all as specified and directed |
| 39 | M&L 50mm thick 1:2:4 type B-0 (12.5 graded grade aggregate) as in copings . |
| 40 | M&L for 50mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as per coping including necessary form work complete all as specified & directed. |
| 41 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed. |
| 42 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as directed. |
| 43 | Taking down Old/ Unserviceable MCBDBs SPN/TPN/ Main Switchesby disconnection of electric connection including old unsvMCCBs,MCBs, isolators etc and making good to distrubed surface complete all as directed. |
| 44 | M&L for point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia medim grade on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of modular switch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 45 | All as per Ser item No 44 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 46 | All as per Ser item No 44 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 47 | All as per Ser item No 44 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 48 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 49 | S&F Switch modular singlepole , one way 16 Amps complete all as specified and directed. |
| 50 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 51 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 52 | S&F Ceiling rose, 3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 53 | S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 modulecomplete all as specified and directed. |
| 54 | M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 55 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 56 | Supply and fix MCCBDB VTPN 4 way with metal door suitable forProvision ofincommer and out going MCCBs/MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 57 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed. |
| 58 | S&F in replacement ofMCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 59 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles. |
| 60 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 61 | S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed. |
| 62 | S&F exhaust fan steel body AC single phase, 230Volts of size 300 mm sweepcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 63 | S & F Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 64 | S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device.luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site. |
| 65 | Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable all as directed. |
| 66 | Excavation intrenches in loose/soft soil not exceeding 1.5 metrewide and not exceeding 1.5 metredeep for laying of cables,poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified. |
| 67 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed. |
| 68 | Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick |
| 69 | Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement |
| 70 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed |
| 71 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I filling with charcoal dust , and common salt,including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate. |
| 72 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |