Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE PART A (B/R) PORTIONTaking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed. |
| 2 | M&L for 10mm thick Polymer modified ready mixed cement based plaster on fair faces of brickworkor concrete surfaces finished the surfaces even & smooth including Make Easy plast from wall plast chemplast, Ready Plast from ultra tech complete all as specified. |
| 3 | M&L for Ready mix plaster 15mmthick (10+5) on bricks or concrete surface including dubbing coat to match with existing with necessary scaffolding upto 18m heightMake Easy plast from wall plast chemplast, Ready Plast from ultra tech complete all as specified. |
| 4 | Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etcby low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force. |
| 5 | M&L for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. \"Feovert\" of \"Krishna Conchem\" OR \"Roff Rust Cleaner\" of \"Pidilite\" OR \"Shali Rustoff\" of \"STP Ltd\", on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) |
| 6 | M&L for Anticorrosive Treatment to ReinforcementEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed.Note:- Mode of measurement: superficial area of concrete will be measured. |
| 7 | M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete& new concrete by brush application complete all as specified and directed. |
| 8 | M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed. |
| 9 | M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 40mm thickness including levelling, profiling etc in two layers,each layer not exceeding 20mm, complete all as specified and directed. |
| 10 | M&L Providing and laying Super fluid Microconcrete of minimum(M-40grade)-Roffecrete repairs or equivalent as specified in the List of Brandnames) in beam bottoms,columns, slabs etc. including mixing with 5mmto10mm size aggregates,waterproof plywood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification and ConsultantsInstructions.The item shall be paid on actual consumption of Microconcrete. Rateof this itemshall include chipping of concrete, surface preparation, rust removal and prevention treatment as per specs and in accordance with consultants suggestions and directions. The item shall bepaid on actual consumption of Micro concrete. |
| 11 | M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 12 | Opening the Separation Cracks at theJunction of RCC and Masonry where ever directed and instructed into‘’V’’Grooves2’’ to 3’’ from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed. |
| 13 | Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “PolyalkEP” and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks/Grooves by Providing and applying “PolyalkEP” Polymer modified cement mortar (or equivalent as specified in the List of Brandnames) in Proportion of 1:5:15 (Polyalk EP:Cement:Gradedsand/quartzsand) on the prepared surfaces and finishing it in level with the existing plaster Including Handpacking, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed. |
| 14 | Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same as directed. |
| 15 | Providing and fixing12mm dia meter aluminum/ PVC injection nipples and securing the same as directed & Providing and injecting cementitious groutusing CEBEX-112 additive of ‘Fosroc’ at the rate of 225grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete |
| 16 | Providing & fixing epoxy dipped shear keys of 10mm dia and 4\" to 6\" length in columns before jacketing, Micro concreting as per Consultants Instructions and directions. |
| 17 | EPOXYGROUTING:Providing, injecting and grouting High molecular weight Super Low Viscous (3 to 5 cps) 0.56Kg/cm2 Epoxy Thermoset Resin Monopol (Krishna Conchemor equivalent) for Slab/Beams/Columns in appropriate proportion as per manufacturer’s specifications into cracks/honeycomb area of concrete including drilling minimum 50mm deepholes of required dia. in concrete, fixing nipples8 /10mmdia., injecting grout by suitable gun/pump at1.0to2.0Kg/cm2 pressure and subsequent cutting/removal of the nipples and sealing of the hole and groove after completion of grouting with cement / epoxy mortaras directed by the Engineer in-charge. Ratestoinclude searching the cracks, opening the same,fixing the nozzles&making all other provisions as per the manufacturer specification/ instructions to make the water tight structure only the affected area. Make: Sunanda, Pidilite, Krishna Conchem, BASF, Fosroc |
| 18 | Providing and laying in position plain cement concrete of specified grade cement with /granite/quartzite/gneiss metal mixing in concrete mixer including bailing out water,compacting, finishing surface, curing and including the cost of centering and shuttering at all level Nominal Mix of 1:1:2 M25 GRADE (1 cement OPC:1 coarses and: 2 graded stone aggregate 20 mm nominal size) |
| 19 | Supplying, Drilling/ Cleaning hole and injecting Hilti make ETA Approved HY-200-R chemical. Application to be designed separately for Rebarsas Simply Supported, Moment or Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as aminimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of cleanair, filling resin and hardener usings errated nozzle to eliminate mixing error with standard HDE A22 battery dispenser alongwith piston plug. The installation and the setting instructions shouldbe strictly followed as per themanufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the projectmanager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existingre bars.HY200-10mmdia 200mm depth.(Rates includes scaffolding cost ) |
| 20 | M&L for leakage / seepage proof coating consisting of preparing the newsurfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltdas approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8 hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed.Notes:(i)The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. |
| 21 | M&Lfor prepration of newlyplaster/concrete surface of walland applyingtwo coat of distemper oil emulsion on walls with one coat of primer ( chalk white on plastered surfaces) and including 3mm thick puttyapplying complete all as specified and directed |
| 22 | M&L for preparing old decorated surfaces of wall (plasterered or unplastered or complete removal of existing treatment) & applying two coat of oil bound distemper over3mm thick wall care putty complete all as specified. |
| 23 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick, with expansion joints & top surface finished even and smooth without using extra cement etc complete all as specified and directed. |
| 24 | M&L 18-20mm thick machine cut, prepolished cuddappa stone slab as in steps, jambs, pillars, window- cills, cooking platforms and like pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab etc, also including moulding/rounding to edges of the slab, including dismantling of existing tile slabcomplete as specified and directed. |
| 25 | Taking down carefully existing aluminium sliding window shutters, taking down of existing broken 4 mm thick plain sheet glass from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing 4 mm thick plain sheet glass with and including provision of new rubber gasket and re-fixing the shutters in existing position, complete all as specifiedand directed. |
| 26 | Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fixNew locking arrangement in place of old oneand re-fixing the sameshutersin existing position etc, complete all as specified and directed |
| 27 | Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but notexc4 Sqmeach including complete all as specified and directed. |
| 28 | Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) Sqm but notexc 1.5 Sqmeach including complete all as specified and directed. |
| 29 | S&F second class hard wood plain, solid straight chowkats and frame, wrought framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints including making good disturbed surfaces of wall complete all as specified and directed |
| 30 | S&F Factory madePlain framed, panelled shutters, 35 mm thick of second class hard wood (Hollock) (any numbers of panels) with panels of 12 mm thick veneered particle board exterior grade medium density with commercial veneering on both faces with sheesham wood beading all round the panel made out of 20 by 15 mm , on one side and fitted to chowkhats complete all as specified and as directed. |
| 31 | S&F 100 mm long stainless steel butt hinges fixed with stainless steel screw |
| 32 | S&F aluminum anodised barrel tower bolts of extruded section of size 150 mm length |
| 33 | S&F 150 mm extruded aluminum alloy handles, fabricated type anodised |
| 34 | S&F aluminum anodised sliding door, bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy, length of bolts 250 mm. |
| 35 | M&L for preparation surfaces of new orprevisouly untreatedwood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 36 | Removing plant/growth including its roots upto 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed. |
| 37 | M&L Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 centimetre width or girth and applying One coat of synthetic enamel paint complete all as specified and directed. |
| 38 | S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame,shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearingetc complete all as specified and directed(Aluminium section shall be of make Jindal/Hindalco/ Indalco) |
| 39 | Supply only4mm thick sheet glass, ordinary qualityfixed in aluminium window along section all as specifiedanddirected |
| 40 | S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel including drilling as required in RCC sections in rectangular or architectual type balcony opening in existing building, complete all as specified and directed. Note: The Grills shall be of Model DG-100/DG-102 of Make Deco or equivalent make as approved by the GE. |
| 41 | Demolition of Cement Concrete (Reinforced) of any description and in any position not otherwise specifically provided for |
| 42 | S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed. |
| 43 | Dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof/wall coverings |
| 44 | S&F in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling of roof sheetany type |
| 45 | M&L Cement Concrete Type D2 1:4:8 (40 mm graded aggregate) in subbase 75 mm thick |
| 46 | M&L Glossy finished Machine pressed precast concrete interlocking paver block Coloured any shape and size confirming to IS 15658-2006 of 60mm thickness, with white cement and pigmentM-35 Grade complete all as specified |
| 47 | M & L for sandcushioning for paver bocks complete including spreading ramming levelling and watering all as specified |
| 48 | S&F Steel rolling shutters1.25 mm thick, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete. including dismantling of old MS gate of any type and any description complete all as spd. |
| 49 | S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified |
| 50 | S&F Ball bearing for rolling shutters complete all as specified and directed. |
| 51 | S&F for pvc tiles/sheets 2.0mm thick homogeneous laminated plain coloured laid with approved rubber based adhesive in floors complete all as specified and directedby eng in charge . |
| 52 | M&L for Antitermite treatment along the external wall below concrete for masonary apron using chemical emulsion @ 2.25 litre per linear meter incl drilling and plugging 12 mm dia holes holes in appron complete alll as specified. |
| 53 | M&L for Antitermitetreatment of soil under existing floors using emulsion @ one litre per hole 300 mm drilling apart including drilling and plugging 12 mm dia holes with cement mortar 1;2 (1 cement 2 coarse sand ) to match the existing floors. complete all as specified and directed |
| 54 | M & L for treatment at point of contact of wood work by chemical emulsion (in oil or cerosine based solution) @ 0.5 lit/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre complete all as specified and directed |
| 55 | Demolition cement concreteany description and in any positionnot other wise specifically provided for Complete all as specified |
| 56 | Dismantling of brick work /stone boulders built in cement mortar including all quins, arches, pillars etc complete all as specified and as directed. |
| 57 | M & L Brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 m mean radius built CM 1:6 complete all as specified. |
| 58 | M & L for Precast cement concrete block masonary with solid blocks type C1 1:3: 6 set in cement mortar 1:6 (20mm graded aggregate)exc 10cm in width and setting in mortar complete all as specified and as directed. |
| 59 | M&L for rendering 15 mm thick cement plaster in CM 1:4 onbrick Work or concrete surfaces including finished even and smooth without using extra cementcomplete all as specified and directed. |
| 60 | Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth and exceeding 10 sqm on plan for foundation etc or for shaft, wells cesspits, manholes etc and getting out in any type ofsoil. |
| 61 | Returning and filling in, including, spreading, levelling, watering and well raming in layers n.exc 25cm in hard/Dense soil. |
| 62 | Removing excavated material (Soil) n.exc. 50m and sepositing where directed at a level n.exc. 1.5m above the starting point |
| 63 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 64 | M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping/benching including weathering throting ans necessary formwork complete all as specified. |
| 65 | M&L cement concrete 1:2:4 Type - B1 ( using 20mm graded stone aggragate) as in surface channel & drain all as specified and directed |
| 66 | M&L Extra for forming fair finished drains or channels exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 67 | M&L for preparation of new plaster surfaces applying two coat of white washcomplete all as specified and directed. |
| 68 | Relieving Structural members such as column,beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timberrunners,bracing, jackingup arrangement all Completetothesatisfaction ofEngineer incharge (Removingand redoing of brickwork, if required, shall be paid separately. |
| 69 | M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-290 grade E-165 |
| 70 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 71 | S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 72 | S&Fsteel screws bolts (Machine made) made hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with one hexagonal or square nut , exc 5 cm but n exc 10 cm long dia of shank 5 to 10 mm complete all as specified and directed. |
| 73 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specified and directed. |
| 74 | Providing all materials and labour for painting steel surfaces, grills,etc. including scaffolding, scrapping existing paint applying a priming coat of epoxy primer filling the crevices and holes with painters putty as approved by Engineer in charge and painted with two or more coats of epoxy paint of approved quality. |
| 75 | SCHEDULE PART A (E/M )PORTIONTaking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etcand making good disturbed surfaces of walls/ roof etc, complete all as specified and directed. |
| 76 | Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed. |
| 77 | M & L forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc,for mounting modular switches, sockets, fan regulators etc with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, including Modular cover plate of suitable size etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressedsteel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screwsall as specified for one light / fan / bellpoint controlled by one switch. |
| 78 | -Ditto- all as per item No 77 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 79 | -Ditto- all as per item No 77 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 80 | All as per item No. 77 above but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board |
| 81 | S&F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 82 | S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 83 | S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. |
| 84 | S&F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. |
| 85 | Taking down and refixing in repairs Wall mounted Fan 600 mm sweep, operating on single phase,230V, AC, 50 Hz having speed of 1440 RPM, air delivery 270 CMM, power output of 180W star rated along with blade, canopy, mounting brackets, rubber insulator. |
| 86 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 87 | S & F Modularcover plate 8 modules |
| 88 | S & F Modularcover plate 3 modules |
| 89 | S & F Modularcover plate 2 modules |
| 90 | S & F Modularcover plate 1 modules |
| 91 | S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. |
| 92 | S&F modular type 3/5 pin socket with one single pole MCB 20 Amp 230 Volts complete all as specified including concealing in wall suitable for Geyser, AC and Domestic appliances complete all as specified and directed. |
| 93 | Supply And Fix in repairs MCCB DB TPN 12 Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories & connecting of existing cables & providing of acbel glands, a) MCB TPN 63 A 25 KA 415 Volt - 2 Nosb) MCB TPN 40 A 25 KA 415 V- 2 Noc) MCB SP 25 A 25 KA 230V - 14 Nos.d) Bus bar, Din rail , Neutral link |
| 94 | M&L for sub mainwiring with twosingle core 6.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin through PVC concealed conduitwith and includingPVC insulated 6.0 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 95 | M&L for sub mainwiring with twosingle core2.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughPVC concealed conduitwith and includingPVC insulated 1.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 96 | M&L for sub mainwiring with twosingle core4.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughPVC concealed conduitwith and includingPVC insulated 1.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 97 | S&F in repair/replacement of building Security lightfitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 98 | Supply & fix in repairs very high efficiency round LED Highbay light fittings 120 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton / Havells /Bajaj. |
| 99 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 coreMake: KEI/ Polycab/ RR Kables |
| 100 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 101 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 102 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 103 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 104 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.Make: Mehtab tiles/ National |
| 105 | Renewal of broken/wornout earth pit including M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long(100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications completeall as directed by Engineer-in-Charge.(a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns .Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm,External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms,Recommended for normal soil conditions. Confirms to IS : 3043 – 1987.(c)Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge. |
| 106 | Supply & Fixing air termination Copper rod 12 mm dia, 300 mm long for lightening conductor including base plate with all necessary nut bolts and drilling job etc. |
| 107 | Supply & fixing for Aluminium strip 25 x 3.15mmon wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge. |
| 108 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia, 25mm long hex. head screw. |
| 109 | Supply and fixing of GI strip 32 x 6mm with saddles and fixing screws etc for roof conductor and down conductor as required and directed by Engineer-in-Charge. |
| 110 | Supply & fixing aluminium strip 25 x 3.15 mm fix on porcelain insulator for roof conductors and down conductors above ground level as lighting conductor (including insulater) for building /store shed all as directed including removing the old U/S strips. |
| 111 | M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. |
| 112 | M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail