| 1 | Supply and installation, commissioning of air cooled split unit, air conditioner electric driven,indoor/Outdoor complete with cordless remote control unit, with in built air ioniser and anti dust filter for better indoor air quality, single phase of capacity of 1.5 TR, BEE 5 star rated including all accessories complete all as specified and as directed.Note: Rate quoted by the contractor also inclusive of the following:-(i) Breaking suitable hole in wall for the fixing indoor and outdoor unit including make good to disturbed surface.(ii) M&L un-plasticized PVC medium duty 20mm dia for draining out condensed water.(iii) Supply and fixing factory made, universal bracket wall mountain made with galvanized structural steel, high strength weather proof powder coated modular construction and not less than in 5 kg in weight & suitable to install outdoor unit for split AC upto 2 TR capacity. |
| 2 | Supply and installation, commissioning of air cooled split unit, air conditioner electric driven,indoor/Outdoor complete with cordless remote control unit, with in built air ioniser and Plasma filter for better indoor air quality, single phase of capacity of 2 TR, BEE 5 star rated including all accessories complete all as specified and as directed.(i) Breaking suitable hole in wall for the fixing indoor and outdoor unit including make good to disturbed surface.(ii) M&L un-plasticized PVC medium duty 20mm dia for draining out condensed water.(iii) Supply and fixing factory made, universal bracket wall mountain made with galvanized structural steel, high strength weather proof powder coated modular construction and not less than in 5 kg in weight & suitable to install outdoor unit for split AC upto 2 TR capacity. |
| 3 | Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. |
| 4 | Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. |
| 5 | M&L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 4.0 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories. heavy duty ISI marked after chasing in wall / ceiling etc, including PVC insulated multistranded copper conductor 4.0 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. |
| 6 | M&L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 16 Sq mm nominal area and draing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size with single run of PVC insulated with 16 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of conductor cable, one runs of earth cable and one run of PVC conduit will be measured as one unit. |
| 7 | M&L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and draing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size with single run of PVC insulated with 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of conductor cable, one runs of earth cable and one run of PVC conduit will be measured as one unit. |
| 8 | Supply and fixing of MCB\"C\" series240/415 volts, 50 HZ, 10 KA breaking capacity, ISI marked (IS 8828), complete of following capacities ;- |
| 9 | (a) MCB SP 32 Amps. |
| 10 | (c) MCB TPN 63 Amps. |
| 11 | Supply and fixing of MCCB of 100 Amps of4 Pole 240/415 volts, 50 HZ, 16 KA breaking capacity, complete |
| 12 | S&F Sheet metal enclosure MCB DB Vertical type TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete all as specified and directed. |
| 13 | S&F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed |
| 14 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with onesingle pole MCB 20/32 Amps complete all as specified and directed |
| 15 | S & F blank plate PVC in liew of MCB, piano switch,Socket etc complete all as specified and as directed. |
| 16 | M&L for Earthing with Galvanised iron earth plate electrode 600 mm x 600 mm & 6 mm thick burried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GLconnected to main earthing lead 4mm dia GI wire by means of GI nuts, bolts & washersall as shown inelectrial plate No 3 MES Schedule Part I protected by 15 mm bore GI pipe light grade, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:1.5:3 A1 40mm thick reinforced with 3Nos6mm dia bars both way, watering arangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necesary excavation and earth works in any type of soil, including test point, testing & commissioning, complete.(Note;-earth lead & protection pipe up to and including 7.5 m length is deemed to included in unit rate quoted by the contractor). |
| 17 | M&L for Supply, test, erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-55,11 mtrs HT poles complete all as directed by Engr-in-Charge. Note:-(i)Crane charges for erection shall be deemed to be including in quoted rate.(ii) Earth work,PCC,coping shall be measured and paid separately.(iii) The rates include staying the poles in a truely vertical position till the foundations are properly set.(iv)The rates include cast iron base plate,nuts,bolts,screws,painting of steel tubular poles,drilling of holes in steel tubular poles for fixing of clamps,hooks for continuousearth wire/strip. |
| 18 | Supply, installation, testing and commissioning of Step downcopper wound transformer of Capacity 160 KVA, outdoor type, PCC Plinth mounted complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014, (Level-2) Oil Cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:-a) Three numbers porcelain bushing HT,11KV with Brass bushing Rod, Nuts, Bolts and washers etc inside cable end boxb) One cable box LT Side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 Core LT UG Cablesc) Oil Conservator with filter type drain valve and oil level Guaged) Dehydrating breather with fast feel of Dehydrating agente) Explosion Ventsf) thermometer pocket on tank coverg) Rating Plate on terminal marking plateh) Earthing arrangementi) Oil drain filter valvej) Oil Drain Valvek) Lifting Hookl) Oil Conservator with filling hole and capm) Air release valve plugn) Four Plate solid Cast steel detachable rollerso) Earth Bushing for Neutral Outside the cable box for providing independable earthing for neutralp) Suitable size of Channel on foundation for fixing the transformer with joint and stoppperq) PCC Platform complete for transformer |
| 19 | Supply, test, install & commissioningof HT 11 KV outdoor type gang operated air break switch triple pole mechanically operated suitable for horizontal or vertical mounting(suitable for existing one) on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps and connecting up with jumpers, testing and commissioning complete all as directed by Engr-in-Charge. |
| 20 | Supplying, fixing, connecting and testing single pole zinc oxide (gap less surge type), heavy duty, station class, self supporting outdoor type lighting arresters having rated voltage 09 KV (RMS), discharge current 10 KA insulation level 28/75 KV/KVp (peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of zinc oxide in dermetically sealed container, complete, with metal base, base insulator and suitable terminals for ground connections and pressure relieving arrangement, fixing with suitable nuts, bolts and washers etccomplete all as specified and directed. |
| 21 | Supply & Fixing pin type insulator 11 KV grade porcelain vitreous brown or green insulator including one galvanised iron washer and one nut150mm high and 150 mm dia complete allas directed by Engr-in-Charge. |
| 22 | M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 23 | Supply, stringing and fixing ofAluminium conductor steel reinforced (ACSR) OH conductor of any type including binding wire complete all as specified and as directed. |
| 24 | M&L stay assembly comprising of MS stay plate 6 mm thick and of size 300 x 300 mm and 20 mm dia MS stay rod, 2150 mm long including thimbles GI stay strand 7/3.15 mm dia of required length complete all as shown on electrical plate No.1 on page No.495 of MES SSR Part-I 2009 including necessary excavation PCC 1:3:6 Type C2 (using 40mm graded stone aggregate), loop insulator as specified in SSR complete all as directed by Engr-in-Charge. |
| 25 | M&L for loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimensions 90 x 140mm size, clearance of hole 25.5 mm complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for Cable jointing kit for 11 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as directed. |
| 27 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of following sizes complete all as specified and directed. |
| 28 | (a) 3.5 core x 150 Sqmm |
| 29 | (b) 4.0 core x 25 Sqmm |
| 30 | (c) 3.5 core x 400 Sqmm |
| 31 | (d) 3.5 core x 50 Sqmm |
| 32 | Supply ,fabrication, installation and testing of LT Panel In door type factory made CPRI Approved, water and vermin proof protection ofsuitable size as per IS specificationmade out of 3.15 mm thick outdoor type CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 33 | INCOMMING |
| 34 | (b)4 pole MCCB 250 Amps , adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 36 KA including all fixing accessories with both ends spreader links - 01 No. |
| 35 | (c)LED Neon indicator lamp (RYB), 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 36 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 37 | OUTGOING : (a)Copper bus bar of 400 Amps rating with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos |
| 38 | (a)4 Pole MCCB 100 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-04 Nos ( 4 Nos for 4 TPN DBs ) |
| 39 | (b) MCB TPN 32 Amps C series , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 10 KA breaking capacity including all fixing accessories with both ends spreader links-01 Nos (Spare) |
| 40 | (c)Digital Ammeter of range (0- 200) Amps, flush mounting type with CT’s of ratio 200/5 and selector switch – 05 set. |
| 41 | (h)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 42 | Supply and fixing cable tray steel with cover of size 200 X 150 X 2 mm thick including all necessary fitting accessories complete all as specified and as directed. |
| 43 | Excavation in trenches, in any type of soilnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil etccomplete all as specified and directed. |
| 44 | Excavation in trenches not exc. 1.5M wide and exc.1.5M & upto 3.0M tin depth for foundation ofstay/ pole and etc and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge. |
| 45 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 46 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 47 | M & L in repair for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. |
| 48 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm all as specified and directed by Engr-in-Charge. |
| 49 | M & L for size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed. |
| 50 | M/Lfor cement concrete in foundation (1:4;8) type D2 using 40 mm graded broken stone aggregate for base of foundation complete as specified |
| 51 | M/L for cement concrete in foundation (1:3;6) type C2 using 40 mm graded broken stone aggregate including form work complete as specified |
| 52 | M/LforPCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary formworkcomplete all as specified and as directed. |
| 53 | M&L for Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPEof not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compoundto provide maximum contact between the electrode and Back Fill Compound.GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of450 x 450 mm complete all as specified and directed.Note : After completion earth resistance shall be recorded with earth megger and the record should be submitted to to department duly signed by contractor. |
| 54 | Supply, installation, testing and commissioning of Step downcopper wound transformer of Capacity 315 KVA (LEVEL 3), outdoor type, plinth platform of size 2.4 x 2.4 x 1.2 Mtr complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as perIS:1180 (Level 3) Oil Cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:-a) Three numbers porcelain bushing HT,11KV with Brass bushing Rod, Nuts, Bolts and washers etc inside cable end boxb) One cable box LT Side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 Core LT UG Cablesc) Oil Conservator with filter type drain valve and oil level Guaged) Dehydrating breather with fast feel of Dehydrating agente) Explosion Ventsf) thermometer pocket on tank coverg) Rating Plate on terminal marking plateh) Earthing arrangementi) Oil drain filter valvej) Oil Drain Valvek) Lifting Hookl) Oil Conservator with filling hole and capm) Air release valve plugn) Four Plate solid Cast steel detachable rollerso) Earth Bushing for Neutral Outside the cable box for providing independable earthing for neutralp) Suitable size of Channel on foundation for fixing the transformer with joint and stoppperq) PCC Platform complete for transformer |
| 55 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95sq mm complete all as specified & directed. |
| 56 | Supply ,fabrication, installation and testing of LT Panel out door type factory made , water and vermin proof protection of suitable size made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 57 | INCOMMING |
| 58 | (a) ACB 4 pole, 415 V manual Draw outdoor type with micro processor release of capaicty 630 Amps, Make : Legrand /L&T /Siemens or equivelent:- 01 Set (I/C from AMF panel) |
| 59 | (b)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 60 | (c)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 61 | OUTGOING |
| 62 | (a)Copper strip busbar of 800 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 63 | (b)4 Pole MCCB 250 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos (One for Stadium, One for short range simulator room-01 nos ) |
| 64 | (c)4 Pole MCCB 160 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-01 Nos (One for long range simulator room ) |
| 65 | (d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -05 set (set of three)Make :- Legrand/L&T/Schneider.(For each O/G) |
| 66 | (e)Digital Ammeter of range (0-250) Amps, flush mounting type with CT’s of ratio 100-500/5 and selector switch – 05 set.(For each O/G) |
| 67 | (f)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 68 | Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of suitable size made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 69 | INCOMMING |
| 70 | (a)4 Pole MCCB 250 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity including all fixing accessories with both ends spreader links-01 Nos |
| 71 | (b) 4 pole ON LOADChangeover switch 415 volts in sheet metal encolsure of capacity 250 Amps including all fixing accessories with both ends spreader links - 01 No. |
| 72 | (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 73 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 74 | OUTGOING |
| 75 | (a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 76 | (b)4 Pole MCCB 160 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-03 Nos |
| 77 | (c) 4 Pole MCCB 63 Amps, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-01 No |
| 78 | (d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -04 set (set of three)Make :- Legrand/L&T/Schneider.(For each O/G) |
| 79 | (e)Digital Ammeter of range (0-200) Amps, flush mounting type with CT’s of ratio 100-500/5 and selector switch – 04 set.(For each O/G) |
| 80 | (f)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 81 | Supply and fixingof GI tubing, light grade, 80 mm bore with all fitting lais in trenches / pole / wall for protection of cables complete all as specified and directed. |
| 82 | Supply and fixingof GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables complete all as specified and directed. |
| 83 | M & L for horizontal boring mechanically across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of sch\"A\"). |
| 84 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |