| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and directed. |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc., not exceeding 10Sqm on plan andnot exceeding 1.5m in depth complete all as specified and directed. |
| 3 | Excavation in trenches in soft/loose soil exceeding 1.5 metre wide andnot exceeding 3 mtr depth and getting out soil including forming bottom surface to required slope/ gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc.,not exceeding10Sqm on plan and not exceeding 1.5m in depth complete all as specified and directed. |
| 4 | Returning, filling in trenchesincluding spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by Engineer-in-Charge. |
| 5 | Spreading & levelling in layers not exceeding 25 cm thick & well ramming incl watering as required complete all as specified and directed. |
| 6 | Removal of surplus excavated soilnot exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 7 | M&L for plain cement concrete 1:4:8 type D-2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. |
| 8 | M&L reinforced cement concrete M-25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in foundation including rafts, footings,plinth beams, and mass concreteetc.complete all as specified and directed.Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 9 | M&L reinforced cement concrete M-25 (design mix)(using20 mm gradedcrushedstoneaggregate) as in columns,pillars, piers,post and struts etc.complete all as specified and directed.Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 10 | M&L reinforced cement concrete M-25 (design mix) (using20 mm gradedcrushedstoneaggregate)as in lintels beam, floor/roof Beams, cantilevers, bressummers, etc complete all as specified and directed.Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 11 | M&L reinforced cement concrete M-25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canpoies deck slabs and in shelves and the like all as specified and directed.Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 12 | M&L for Brick work with using fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed. |
| 13 | M& L for Brick work with fly ash bricks straight or curved on plan to any radiusin half brick thick wall built in cement mortar 1:4, complete all as specified and directed |
| 14 | Use & wasteof form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, andplinth beamand similar work for rough finished flat surfaces of concrete complete all as specified and directed. |
| 15 | Use and waste of form work to sidesof columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed. |
| 16 | Use and waste of form work to sides of soffit of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. |
| 17 | Use and waste of form work to sidesandsoffit oflintel Beam,floor/roof Beams, etcfor rough finished surface of concrete complete all as specified and directed. |
| 18 | S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge. |
| 19 | S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube for top and bottom rails. mild steel framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all asfixing in the frame at site as per specification and drawing complete all as specified and as directed. |
| 20 | S & F Aluminium anodised handles of extruded section and fixed 150 mm long complete all as specified & directed. |
| 21 | S & F Aluminium anodised barrel tower bolts of extruded section and fixed 150 mm long complete all as specified & directed.. |
| 22 | S & F 100 mm size Butt hinges medium weight cold rolled mild steel and fixed complete all as specified & directed. |
| 23 | M&L for mild steelTMT bars 10 mm dia and over grade Fe -500 , asin reinforcement ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 24 | M&L for mild steelTMT bars 08 mm dia and over grade Fe -500 , asin stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 25 | S & F for steel windows or ventilators, fixed type, with glazing bars complete including prepartion ofnew or previously untreated steelsurface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 26 | M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushedstone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 gradeand sand in the ratio 1:3 including necessary form work , complete all as specified and directed. |
| 27 | M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub baseto flooring/hard standingetc ,complete all as specified and directed. |
| 28 | M&L for hard core of broken stone or bouldergauge not exceeding 63mm deposited, spread & leveled in layers not exceeding15cm thick, watered and rammed to a true surface etccomplete all as specified& directed. |
| 29 | M & L glazed ceramic coloured tiles of size 300 mm x 450 mm x7mm thick/350 mm x 250 mm x7mm thick,as in vertical surfacesuch as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles,over & including 10 mm thickrendering incement mortar 1:4 complete all as specified and directed. |
| 30 | M&L fornon skid colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 31 | M&L for rendering 10 mm thick on brick masonry/concrete surface etc in CM (1:6) surface finished even & smoothusing extra cement complete all as specified and directed. |
| 32 | M&L for rendering 15 mm thick on brick masonry/concrete surface etc in CM (1:6) surface finished even & smoothusing extra cement complete all as specified and directed. |
| 33 | M&L for 15mm thick rendering (external) on stone masonry surfaces or on other than fair face of brick work or concrete surface in cement mortar 1:4,with liquid water proofing compound@ 200 ml/50 kg per bag of cement , finished even and smoothwithout using extra cement complete all as specified and directed(Note:Water proofing compound shall be measured and paid seprerately under respective item of \"BoQ\") |
| 34 | M&L for 5mm thickcement plastering in cement mortar 1:3 on concrete ceiling surfaces finished even & smooth without using extra cement omplete all as specifed and as directed. |
| 35 | M&L for preparation of newly plastered surfaceofceiling and applying three coats of white wash on ceiling surface complete all as specified and directed. |
| 36 | M&L for prepatation of new plaster surface andapplyingone coat of distemper oil emulsion (OBD) any shadeover a coat of chalk whitening primer on ceiling surfaces to make entire surface free from undulations complete all as specifiedand directed |
| 37 | M&L for preparation of newly plaster surface of walls/chajjas/lintel and applying two coats of cement base paint white or tinted over a coat of alkali resistant primer including necessary scaffolding complete all as specified & as directed. |
| 38 | S&F 3.0 mm thick figured glass pin headed type in squares/ rectangularnot exceeding 0.5 Sqm ineach pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete all as specified & directed. |
| 39 | M&L for prepartion ofnew or previously untreated steelsurface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 40 | Supplying & laying 15 mm bore of pipes Unplasticised PVCpipes of pressurerating 10 kgf/cm2fixed complete towalls, ceilings or infloors etc., any typeof pipe complete all as specified and directed. |
| 41 | Supplying & laying 20 mm bore of pipes Unplasticised PVCpipes of pressurerating 10 kgf/cm2fixed complete towalls, ceilings or infloors etc., any typeof pipe complete all as specified and directed. |
| 42 | Supplying & laying 25 mm bore of pipes Unplasticised PVCpipes of pressurerating 10 kgf/cm2fixed complete towalls, ceilings or infloors etc., any typeof pipe complete all as specified and directed. |
| 43 | S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and directed. |
| 44 | S&F for 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed |
| 45 | S & F for angle cock of 15mm bore, chromium platedwith long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 46 | S & Fstop cock of 15mm bore , chromium platedwith long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 47 | S & F for 32 mm unplasticised PVC pipes of pressure rating 06 kgf/cm2 fixed complete to walls, ceilings or in floors etc.,complete all as specified and as directed. |
| 48 | S& F for PVC connection 15 mm dia size with PTMT nuts of length 450 mmcomplete all as specified and directed. |
| 49 | S & F 110 mm dia PVC rain water pipes single socketed in any length with rubber ring joits fixed to walls with and including stack clamps made out of 40mm by 3mm flat iron and 12mm dia round iron stays and making good the disturbed portion in CM 1:3 to match with surrounding area, complete all as specified and directed. |
| 50 | S & F for 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-in-charge. |
| 51 | S & F 75 mm dia PVC rain water pipes single socketed in any length with rubber ring joits fixed to walls with and including stack clamps made out of 40mm by 3mm flat iron and 12mm dia round iron stays and making good the disturbed portion in CM 1:3 to match with surrounding area, complete all as specified and directed. |
| 52 | S & F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-in-charge. |
| 53 | S & F for PVC (SWR) bends for 110 mm pipe, with rubber ring joints, complete all as specified and as directed. |
| 54 | S & F for PVC(SWR) bendsfor 75mm bore with rubber ring joints, complete all as specified and as directed. |
| 55 | S & F for PVC (SWR) 110 mm bore junction singel, (Single T) equal or unequal, with rubber ring joints, complete all as specified and as directed. |
| 56 | S & F for PVC (SWR) 75 mm bore junction singel, (Single T) equal or unequal, with rubber ring joints, complete all as specified and as directed. |
| 57 | S & F for 110mm bore PVC(SWR) vent Cowl complete all as specified and directd. |
| 58 | S & F for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cementwithchromium platedgratingwith or without hole complete all as specified and directed. |
| 59 | S & F Vitreous China squatting pan Orissa pattern of size 580 mm x 440mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage connection pipe etc completeall as specified & directed by Engineer-in-Charge. |
| 60 | S & Ffor PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including all standard accessories such as inlet ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed. |
| 61 | S & F for 600mm X 450 mm bevelled edge looking mirror of selected quality glass mounted on 6 mm thick PVC sheet with PVC frame and fixed to wooden plugs with CP brass screw and cup washers complete all as specified and directed. |
| 62 | M & L for application of water proofing treatment using APP modified roof membrane over non accessible/ non approachableRCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicatorof the manufacturer with following specification etc complete all as specified and directed :-(a) Cleaning existing surface properly with wire brush &applying10 mm thick plaster /rendering in cement mortar (1:3)mixed with integral water proofing chemical compound, mixed in proportion 200 milli litre per 50 Kg of cement(b) Applying approved bituminousbased primer( conforming to IS: 3384-1995) @ 0.50 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :-(i) Membrane weight not less than 3.00 Kg/Sqm. (ii)Non woven polyester weight not less than 160 gms/Sqm.(iii)Softening point of membrane not less than 150degree Celsius. (iv)Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N& transverse not less than 250N.(vi)Elongation of reinforcement not less than 30%.(vii) Impermeability under water pressure not less than 3 Kg/Sqcm.(d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e) Applying two coat of bituminiousbased Aluminium Paint @ 0.3 Kg /sqm over APP Membrane. |
| 63 | Supply onlywater proofing compound (ISI Marked) complete all as specified and directed. |
| 64 | S & F for vitreous China half stalltype (back to corner ) urinals with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)(back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe etc.complete all as specified and as directed |
| 65 | Taking down existing roof treatment any thickness including plastering, leaping plaster of any thickness cuting & up rooting tree roots/vegitable growth & removing the debris from the premises upto 500m from the MOD land including cleaning/washing down and keeping surfaces cleancomplete all as specified and as directed. |
| 66 | M & L for brushing neat cement slurry (@ 3 Kg of cement per Sqm) mixed with water proofing compound in the proportion ,water proofing compound, water and cement (1:4:7) or as per manufacturer\"s instructions for bonding of old concrete surface to new concrete, complete all as specified and as directed. Note:Water proofing compound shall be measured and paid seprerately under respective item of \"BoQ\" |
| 67 | M & L for plain cement concrete 1:2:4 ,type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral water proofing chemical compound, mixed in proportion 200 milli litre per 50 Kg of cement as in padding, benching, sunken portion & on roof surface for correcting/making proper slope on roof, etc.,complete all as specified and directed .(Note:Water proofing compound shall be measured and paid seprerately under respective item of \"BoQ\") |
| 68 | M & L for cutting 75 mm wide and 65 deep in brick wall/PCC block/RCC surface any location shaping horizontal face groove filled with PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) with and including chemical compound mixed in proportion 200 mili litre per 50 Kg of cement or as per manufacturer\"s instructions laid when concrete is still green, complete all as specified and as directed.(Note:Water proofing compound will be measured and paid seprerately under respective item of \"BoQ\") |
| 69 | M & L for application of water proofing treatment using APP modified roof membrane overaccessible/approachableRCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer /authorized applicatorof the manufacturer with following specification etc complete all as specified and directed :-(a) Cleaning existing surface properly &apply 10 mm thick plaster /rendering in cement mortar (1:3) with WPC as per manufactures instructions(b) Applying approved bituminousbased primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface er .(c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :-(i) Membrane weight not less than 3.00 Kg/Sqm. (ii)Non woven polyester weight not less than 160 gms/Sqm.(iii)Softening point of membrane not less than 150degree Celsius. (iv)Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N& transverse not less than 250N.(vi)Elongation of reinforcement not less than 30%.(vii) Impermeability under water pressure not less than 3 Kg/Sqcm.(d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e) Applying two coat of hot air blown grade bitumen of grade 85/25@ 1.20 Kg /sqm over APP Membranecomplete all as specified and directed |
| 70 | M& L for applying evenly a tack coat of industrial bitumen 85/25grade at the rate of 1.20 kg per sqm in sunken portion including cleaning of surfaces complete.after treatment the same shall be tested for leakage/seepage/dampness by ponding with water for 72 complete all as specified and as directed. hours |
| 71 | S &F in repair 50mm bore tubes light grade galvanised with all fittings laid in flooras in spout pipe, etc complete all as specified and as directed. |
| 72 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 sqmeach and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed. |
| 73 | Taking down chowkats or frames with shuttersexceeding 1.5 Sqm sqm but not exceeding4.00 sqm each (without taking off shutters from the frames) etc including builders hardware etc and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed. |
| 74 | Taking down shutters of any description exceeding1.0 Sq m but notexceeding 2.0 Sq m each and removing from site, complete all as specified and directed by Engr-in-Charge . |
| 75 | S&F for 1.25 mm thick pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in filling in pressed steel door complete all as specified and directed.Note:The quoted unit rate under this item shall deemed to be included (i) one shop coat of primer (ii) a coat of bitumen paint of inner side of pressed steel door framebefore filling of PCC. |
| 76 | S&F for 1.25 mm thick pressed steel frames of size 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in filling in pressed steel door complete all as specified and directed.Note:The quoted unit rate under this item shall deemed to be included (i) one shop coat of primer (ii) a coat of bitumen paint of inner side of pressed steel door framebefore filling of PCC. |
| 77 | S& F 30 mm thick,factory made flush shutters factory made, kiln seasoned and ASCU treated solid core construction, with block board core and ply wood face panels, commercial type on both sides decorative face with lipping/ framecomplete all as specified and directed. |
| 78 | S & F 35 mm thick, factory made, IInd class hard wood glazed and skeleton shuttersopen rebated and prepared to receive glass, gauze, etc. (divided into squares with plain, chamfered or rounded, mitred and rebated sash bars any number size of members),beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); kiln seasoned & chemically pressure treated etccomplete all as specified and directed .(Note:- (i)Glass / wire cloth shall be measured & paid separately.(ii) Sample of shutter in sample room of GE office.) |
| 79 | M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165& for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.complete all as specified and as directed |
| 80 | S&F powder coated (with coating layer of minimum 50 micron thick) aluminium frame for doors, windows, ventilators shutters(fixed/ sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle,C.P. brass/ stainless steel screws, all complete all as specified and directed. |
| 81 | S & F forpowder coated aluminium window , ventilator shutters/sliding shutter with coating layer of minimum 50 micron, Track channel or fixed type without sash bar, aluminum section weighing min 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 82 | S&F in repair18/19mm thick block board, grade -2 quality , interior grade, commercialtype,fixed withscrews to timberframe-workfor cupboard shutter, shelf, etc fixed with screws & favicolincluding making holes with decorative covers for wires where ever required fixed complete all as specified and directed. |
| 83 | S & F for 30 mm width of flaps (when open) continuous (piano) hinges,mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 84 | S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified & directed. |
| 85 | M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge . |
| 86 | S&F 3.0 mm thick figured glass pin headed type in squares/ rectangularnot exceeding 0.5 Sqm ineach pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete all as specified & directed. |
| 87 | S&F 125 mm size ofhasp and staple safety type aluminium anodized hinges pin including bolt to hinges plate complete etc all as specified & directed. |
| 88 | S & F Aluminium anodised barrel tower bolts of extruded section and fixed 125 mm long complete all as specified & directed. |
| 89 | S&F250 mm long aluminiumalloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and directed. |
| 90 | S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed. |
| 91 | S & F for150 mm (overall length of cover plate) floor door stopperwith rubber shoesaluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor complete all as specified and directed. |
| 92 | M&L plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) in for inserting hold fast of doors & window , bed blocks,fillings & similar work etc. including necessary form work complete all as specified and directed. |
| 93 | S&F in repair 20 mm dia Harrison rails, anodised aluminium alloy with bracket etc., complete all as specified and as directed by Engr-in-Charge. |
| 94 | S&F in repair fancy type sofia bracket for the curtain rod (suitable of 20mm dia curtain rod) of any apporved colour and design all as specified and directed. |
| 95 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the allrubbish off from the premises upto 500mtr complete all as specified and directed. |
| 96 | Demolition of plain cement concrete(un-reinforced) of any description and in any position of thickness not exceeding 15 cm (below or above ground level) and removal of rubbish off from sitecomplete all as directed by Engr-in-Charge. |
| 97 | M&L for 10mm thick Light shadevitrified ceramic tiles polished area of each tiles not exceeding0.36 sqm as in floors,set & jointed in neat cement slurry and pointed in coloured cement to match, over & including 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 98 | M&L for 10mm thick Light shadevitrified ceramic tiles polished area of each tilesnot exceeding0.36 sqm, laidin vertical surface as in dado/skirtingetc, over & including10 mm thick rendering in CM 1:4,set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 99 | M&L for machine cut kota stone slab flooring 18mm -20 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing with Bee wax polish, over & including 20 mm thick screed bed in CM (1:4) complete all as specifed & directed. |
| 100 | M&L for 18 mm to 20 mm thick machine cut kota stone slab as in one piece of tread of steps etc., ,laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with Beewax polish over and including 20 mm thick backing coat/screed bedin CM (1:4) etc complete all as specifed & directed. |
| 101 | M&L for 18 mm to 20 mm thickmachine cut kota stone slab in skirtings,riser of steps ,dado & pillar laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with Bee wax polish, over 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed. |
| 102 | Demolition of cement concrete reinforced as in chullah hoods , shelves and plate formetc complete all as specified and directed |
| 103 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form worketc complete all as specified and directed |
| 104 | M&L for joint free non skid colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., over & including 15mm thick screed bed in cement mortar 1:6, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 105 | M & L for PCC (1:5:10), type E-2 (using 40 mm graded brick aggregate) as in sunken portion, sub-base, etc., complete all as specified and as directed. |
| 106 | M&L for precast /cast-in-situ reinforced cement concrete 1:2:4 ,type B-1 (using20 mm gradedcrushedstoneaggregate)as in kitchen platform, shelves ,man hole cover slab/ draincover slab etc. including necessary formwork complete all as specified and directed.Note : Reinforcementwill be measured & paid seperately under respective item of BOQ. |
| 107 | Taking up or down steel tubing and connections of 15 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed. |
| 108 | Taking up or down steel tubing and connections of 20 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed. |
| 109 | Taking up or down steel tubing and connections of25 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed. |
| 110 | S&F for GI water tubing mediumgrade, ISI marked,galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. |
| 111 | S&F for GI water tubing mediumgrade, ISI marked,galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. |
| 112 | S&F for GI water tubing mediumgrade, ISI marked,galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. |
| 113 | Refixing for 15 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)including all fitting as socket, elbow, nipple,union etc complete all as specified and directed .Note :G I Pipe obtained from item No.107 here-in -before. |
| 114 | Refixing for 20 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)including all fitting as socket, elbow, nipple,union etc complete all as specified and directed .Note :G I Pipe obtained from item No.108 here-in -before. |
| 115 | Refixing for 25 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)including all fitting as socket, elbow, nipple,union etc complete all as specified and directed .Note :G I Pipe obtained from item No.109 here-in -before. |
| 116 | S&F rotational moulded polythene water storage tank of capacity1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and25 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms)including taking down of existing tank complete all as specified and directed. |
| 117 | M&L for 20 mm to 25 mm thick machine cut cudappa stone slab as in cooking platform etc.,laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with Beewax polish over and including 15 mm thick backing coat/screed bedin CM (1:4) etc complete all as specifed & directed. |
| 118 | M & L for rounding of edges of Kota/Cuddapah stone slab one edge, such as in steps, cooking platform and other similar work/situation, complete all as specified and as directed. |
| 119 | S & F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed. |
| 120 | S&F in repair for PVC connection 15 mm dia size with PTMT nuts of length 450 mmcomplete all as specified and directed. |
| 121 | S & F in repair for angle cock of 15mm bore, chromium platedwith long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 122 | S & F in repairfor 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 123 | S & F in repair for 15 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 124 | S & F in repair for 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed |
| 125 | S & F in repair for angle cock of 15mm bore, chromium platedwith long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 126 | S & F in repair forstop cock of 15mm bore , chromium platedwith long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 127 | S & F in repair brass chromium plated shower rose with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union complete all as specifed & as directed. |
| 128 | S & F in repairvitreous China wash basin, any colour, flat back size 580 mm X 450 mm including 32mm brass chromium platedwaste coupling , 32 mm borePVC waste pipe, chromium plated Gratingincluding cutting for & pinning in ends of bracket or errecting bracket& PCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) for embedding brackets & making good disturbed surface with CM 1:3 complete all as specified and directed. |
| 129 | S&F WC squatting pan \" Orissa Pattern\" of size 580 mm X 440 mm white with integral foot rest including cast iron \"P\" or \"S\" trap, front or back inlet and making connection to trap & to flushing cistern completeincluding taking down existing pan & making good disturbed surfacecomplete all as specified &directed. |
| 130 | S & F in repair for pillar taps long body chromium plated, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered \"Hot\" or \"Cold\" with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed (Make- Shakti Cat Part No API-6108 or equivalent Cat Part No. of any make as per appendix \"A\" to P.S as approved by GE). |
| 131 | S & F in repair for shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats 450mm long and 150mm wide (minimum weight 300gms) complete all as specified and directed. |
| 132 | S & F in repair stainless steel kitchen sinks with drainage boardfor kitchen made of stainless steel 1.00 mm thick sheet with plugs, washers & waste coupling and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm X 460 mm with double bowl of size 410 mm X 330 mm X 160 mm including 32mm/40 mm bore PVC flexible waste/flush pipe 800mm long with socket fixed with sinkbrass waste coupling complete all as specified and directed. |
| 133 | S & F in repairs stainless steel utensil/Kitchen plate rack of size 24\"X36\"X10\" with steel shelves and hanging arrangments for utensil,complete all as specified and directed. (MAKE : Bluestar/Javana/Prayag) |
| 134 | S&F in repair towel railbrass chromium plated towel rail , 20 mm dia ,D-type 600 mm long between flangesfixed with and including chromium platedbrass screw & wooden /plastic cleats complete set all as specified and directed. |
| 135 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc& removing the debris from the premises upto 500 m from the MOD landcomplete all as specified and directed |
| 136 | Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars, including segregation of serviceable bricks for reuse & removal of rubbish out offfrom site etc complete all as specified and directed. |
| 137 | M&L for repair and rendering 10mm thick in cement mortar 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete surface including cleaning of visible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 type B-O( using 12.5mm graded crushed stone aggregate )including necesssary scaffolding work for double/single storey building complete all as specified and directed. |
| 138 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specifed & directied. |
| 139 | S & F in repair110 mm dia PVC(SWR) WC connector with lip ring, complete all as directed and as specified. |
| 140 | M&L for prepartion ofnew or previously untreated wooden surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat ofpinkprimer complete all as specified & directed. |
| 141 | M&L for prepartion ofold paintedof wooden surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint on oldwooden painted surface complete all as specified & directed. |
| 142 | M&L for preparation of old decorated surfaces of ceiling including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash (lime) on ceiling surface at any height complete all as specifiedand directed. |
| 143 | M&L for prepatation of new plaster surface andapplyingtwo coats of distemper oil emulsion (OBD) any shadeover a coat of chalk whitening primer and a layer of wall care putty (minimum 2.0 mm thick) to make entire surface free from undulations complete all as specifiedand directed |
| 144 | M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces withpreparation ofplastered surfacesincluding preparation of surfaces of wallsand apply two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer(from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick etc complete all as specified and directed. |
| 145 | M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces withpreparation ofplastered surfaces and applying two coats of cement base paint on wall surface etc.,applying by pump roller applicator of any shade or tint complete all as specified & directed. |
| 146 | Taking down carefully unserveciable/damaged copper/aluminium surface (batten/conduit or casing-N-caping) point wiring any length for light/fan/socket or power includingunscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed. |
| 147 | M&L for point wiring for one light/fan point /exhaust fan controlled by one , one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal box covered for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing/ fixingswitches etc.,includingcutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etccomplete all as specified and directed. Note: Proper colour coding to be adopted. |
| 148 | All as per item No 147 here-in-before but 3 pin socket outlet 5 Amp socket outlet on same board.with other switches |
| 149 | All as per item No .147here-in-before but 3 pin socket outlet 5 Amp socket outlet on independent board. |
| 150 | All as per item No .147here-in-before but 3 pin socket outlet 5 Amp socket outlet on independent board. |
| 151 | All as per item No 81 here-in-before with 2.5 Sqmm (nominal area) FRLSH cable PVC for 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor for earth continuity all as specified. |
| 152 | M & LSub main wiring with two runs ofsingle core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 SqmmPVC insulated unsheathedFRLSH multi stranded copper conductor cablefor earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia/appropriate dia with accessories & fittings complete and making good disturbed surface wall including taking down existing sub main wiring complete all as specified and as directed. Note : - Tworuns of 6.0 Sqmm cable andone run of earth wire 6.0 sqmm& conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder. |
| 153 | S&F switch piano flush type polycarbonate single pole one way 6 Amps complete all as specified and directed . |
| 154 | S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed . |
| 155 | S&F socket outlet polycarbonate 2 in 1, 3 pin 6 Amps flush type complete all as specified and directed |
| 156 | S & F Switch socket combination 2 in 1, 3 pin, 5Amp & 15/16 Amp, flush type, universal, complete all as specified. |
| 157 | S & F Switch socket combination 2 in 1, 3 pin, 5Amp flush type, universal, complete all as specified & as directed |
| 158 | S&FSocket outlet 2 in 1, 3 pin, 15/16 Amps, flush type complete all as specified and as directed. |
| 159 | S&Fbell push flush type 5 amp AC, 230 volts, single polecomplete all as specified complete all as specified and as directed.. |
| 160 | S&F in repairelectric Bell, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 161 | S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, ISI marked complete all as specified and as directed.. |
| 162 | S&F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 163 | S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed. |
| 164 | S&F in repairLED bulb of capacity 10 watts lumen out put (1200 lm) length 102 mm dia, 56 mm, base cap B22,(ISI marked) complete with all accessories (ISI marked) all as specified & directed by Engr-in-Charge. . |
| 165 | S &F Inverter LED bulb of capacity 12 watts lumen out put (1200 lm) length 140 mm width 70mm base cap B22, 3 star, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engineer-in-Charge. |
| 166 | S & F for LED batten fitting 1 x 20watt , 220 V, surface mounting including connecting up with two core flexible copper conductor cable of suitable size with flexible pipe from ceiling rose to fitting of any size complete all as specified and as directed by Engineer-in-Charge. |
| 167 | S & F for LED batten fitting 2 feet x 10 W, mirror type , 220 V, ACsurface mounting including connecting up with two core flexible copper conductor cable of suitable size with flexible pipe from ceiling rose to fitting of any size complete all as specified and as directed by Engineer-in-Charge. |
| 168 | S&F 1X9 W/1X10 Wwatt LED Bulkhead fitting with IP 65 environmental frendly, ultra modern, energy saving mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 230 Volts AC circuit includinglight connecting up with two core flexible copper conductor cable and flexible pipe of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-Charge. |
| 169 | S & F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover along with electronic drivertype street light fitting 35/36 watt capacity LED and including allnecessary accessories duly pre-wired, fixing on bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking down old / unserveciable security lights fitting any type and description complete all as specified and directed. |
| 170 | Labour only for the refixingceiling fan/exhaust fan after servicing /repairing/overhauling by cleaning/greasing /oilingetc. including provision of connecting ceiling fan/exhaust fan to ceiling rose includingthree core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connectionand preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (whiteshade) paint and marking MES number with non erasable marker pen with black colourcomplete all as specified & directed by Engineer-in-charge. |
| 171 | Taking down ceiling fan/exhaust fanof any sweep after disconnecting all necessaryelectrical connctions from ceiling roseto fancomplete all as specified and directed. |
| 172 | S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitableamps rated busbar 8 way complete all as specified and directed by Engr-in-charge. |
| 173 | M&L for MCB single pole, 6 to 32 Amp 240 Volt \"C\" curve 10 KA,IP 20 transparent lebel holder fully insulated safety hutters suitable for cable upto 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. |
| 174 | S&F in repair 240V, 10KA\"C\" curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Ampwith breaking capacity 10 KA, in the MCB DB with connection testing and commissioning complete all as specified and as directed. |
| 175 | S&F for 240V, 10KA\"C\" curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Ampwith breaking capacity 10 KA, in the MCB DB with connection testing and commissioning complete all as specified and as directed. |
| 176 | M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in theground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm diaas earth leadby means of bolts, nuts and washers of GIup to test point,GI tubing20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steelhandle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including making good disturbed surface of wall ,floors etc complete all as directed.Notes: -(i)Earth lead & protection pipes length upto & including 7.50 metre.(ii)Earth filling shall be done by vegetable soil.(iii)Soil should be free from stone, boulders, aggregate, gravels etc. |
| 177 | Supply, laying ,jointing ,testing and commissining LT cable, XLPE Insulated ,armoured, electric power cables (heavy dut4.0 corecomplete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item.(2) All Necessary T & P required shall be arranged by the Contractor. |
| 178 | M&L sand filling in cable trenches for cable protection for clean dry sand unwashed including gently punning in a layer of 15 cm and 8 cm (total 23 cm) inthickness all across the laid portion of LT cable in trenches complete all as specified and directed. (Note:-Punned thickness shall only be considered for payment) |
| 179 | Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm,complete all as specified and directed by the Engineer-in-Charge. |
| 180 | S&F in repair Rigid non-metallic PVC conduit ISI mark 20mm dia heavy duty exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and such as couplers, lock nuts, saddles, pipe hooks etc. for LAN,telephoneand TV connections including cutting,chases andmaking good disturbed surface to match with existing finish with plastercomplete all as specified and as directed. |
| 181 | S&F of exhaust fan electric single phase, AC 240 Volts, 50 Hz copper winding, 300mm sweep, 1200RPM made of study Engineering plastic body complete with louvers and connecting with flexible PVC insulated multi stranded flexible copper conductor wire with flexible pipe of required size from ceiling rose including cutting of wall and finisheing of plaster complete all as specified and directed. |
| 182 | Cutting G I pipes in position for insertion of new tees,branches, etc.other type of G I fittingsfor addition/alternation of existing system for 25 mm borecomplete all as specified and as directed. |
| 183 | S & F for 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 184 | S & F double door SPN distribution boards steel sheet powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitable Amps rated busbar 4 way complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail