| 1 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles |
| 2 | M&L for Brickwork with sub-class \"B\" bricks,straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified. |
| 3 | M&L for Brickwork with sub-class \"B\" bricks, but except bricks,straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified. |
| 4 | Taking down cement or cement limeplaster on brick or stone walls, etc. including raking out joints,hacking for key,scrubbing down with water, etc. |
| 5 | M&L for 15mm thick rendering inCM 1:4 on fair faces surface with water proofing compound to brick/concrete wall surface trowelled to even and smooth without using extra cement complete, all as specified and directed.Note : - Supply only water proofing compound shall be measured and paid for separately. |
| 6 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 7 | M&L rendering 10 mm thick onfair faces of brick surfaces or concrete surfaces and finished surfaces even & fair in CM 1:6 complete all as specified and directed |
| 8 | M&L for preparation of new surfaces of wall and applying two coats of cement base paint white or tinted on new wall surface over a coat of primer on walls complete all as specified and as directed. |
| 9 | M&L for preparation of old surfaces of wall and applying one coat of cement base paint over old suface of wall, chajjas, fascias , roof projection complete all as specified and as directed. |
| 10 | Preparation of old surfaces by brooming down or steel wire brushing, scrapping sdown moulds, moss and efflorescent salts and trading oil & greasy spots to wall including cornices etc plaster or un plastered surfaces (Old decorated surface) and applying one coat of white wash on wall all as specified and as directed by Engr-in-charge |
| 11 | Preparation of new plastered surfaces and applying three coat of white wash on wall all as speicified and as directed |
| 12 | Dismantlingtimber scantling framed works 40 sqcm and over in section of any description not otherwise provided for |
| 13 | Dismantling wrought iron or mild steel work of any description |
| 14 | S&F roof trusses (framed), tubular truss, purlines, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections, ) including distance places, cleats etc grade Fe-401-W (Gde-E-250) quality \"A\" complete all as specified and as directed |
| 15 | DismantlingAsbestos cement (corrugated,semicorrugated ,etc )/MS sheet in roof covering complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for Pre- painted galvalume aluminum zinc coating GI basedcorrugated /semi corrugated steel sheet 0.50mm thick of red colour (AZ-150) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 17 | M&L for Pre- painted plain aluminum zinc coating GI basedsteel sheet 0.50mm thick of red colour (AZ-150) having tensile strength of 550 Mpa as inridge, gutter, valley, fixed with self tapping screws complete all as specified and as directed. |
| 18 | S & F 1.25 mm thick Plain, black, mild steel sheeting, in ridges, hips, tail piece / sockets, valley gutters, drip and straight flashings (length and girth as fixed) fixed with welding /self tapping screws complete all as specified and as directed. |
| 19 | Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 20 | M&L for providing and fixing powder coated MS galvanised steel inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, fixed to angle iron truss with 2-3 mm GI wirewith galvanised butterfly level clips for all hights complete all as specified and as directed. |
| 21 | M&L for 4 mm thick prepainted designer non-asbestos fibre cement building board and fixed on false ceiling grid with screws andincluding10 mm wide disginer POP strip all round at the junction of wall and false ceilingcomplete all as specified and as directed by Engg.-in-charge. |
| 22 | M&L for cement concrete 1:2:4 type C1 using 20 mm graded stone aggregate as in coping or roof kerbs benching, coping,bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, as direteed incl necessary form work all as specified and directed |
| 23 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. |
| 24 | M&L for preparation of old painted steel surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed |
| 25 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 26 | Supply and fixing in replacement of LED street light fitting 120 watt 230v AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. |
| 27 | Supply and fixing in replacement of LED flood light 100 watt 230v AC Outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as directed at site. |
| 28 | Supply and fixing in replacement of LED flood light 200 watt 230v AC Outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as directed at site. |
| 29 | Supply and fixing in replacement of Post top lantern LED type 30W 230VAC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 30 | Supply and Fixing in replacement MCB single pole 6 Amp-32 Ampfor street light junction box / panelincluding connection complete all as directed . Make: Havells/L&T/ Legrand /ABB |
| 31 | Supplying and fixing in renewal MCB single pole 230 volts 50 Hz AC of rating40 to 63 Amp including connectioncomplete all as directed. Make: Legrand/Havells/ABB/ L&T |
| 32 | Supply & Fixing Power Contactor 63 - 80 Amp rating 4 pole including all connected accessories with suitable rating like coil / auxiliary Contact etc) as per site requirement and suitable for street light controll panel complete with all connection as directedMake: L&T /Schneider / Legrand /C&S / BCH |
| 33 | Supply & Fixing Power Contactor 25 to 40 Amp rating single pole including all connected accessories with suitable rating like coil / auxiliary Contact etc) as per site requirement and suitable for street light controll panel complete with all connection as directedMake: L&Tor equivalent of Schneider / Legrand /C&S / BCH |
| 34 | S&F of Aviation obstruction light luminaries fittings having integral LED aviation light comprising of aluminium housing with polycarbonate enclosure at the top of the pole and making necessary electric connection and fixing arrangement of aviation light Cat Part No BGAV 302 LED or eqvt |
| 35 | S&F in replacement LED Bollard Cylindrical shaped cast aluminium with opaque threaded polycarbonate diffuser for optimum ingress protection IP 65, 12 watt with integrated driver and all necessary work complete all as specified and directed |
| 36 | Supply and fixing in replacement LED bollard with Mushroom shaped 09 Watt, with bulb holder, suitable for LED bulb with cast aluminum housing and polymer diffuser for pleasant light output, IP 65 protection complete all as directed at site. |
| 37 | M&L for rewinding of electric motor upto 2.5 HP capacity with super enamel copperwire of existing gauge including insulation and varnishing, including repair to gear boax after dismantling all electrical and mechanical connection from High Mast light, testing and commissioning at site complete all as specified and as directed. |
| 38 | M&L for replacemet of high mast wire rope of existing size complete all as specified and as directed. |
| 39 | Supply & fix of MCB TPN40 to 100 Amps,\" C\" series , bracking cap 10KA, 415V complete including taking down old MCBsall as specified and directed. |